• Title/Summary/Keyword: 온도경사

Search Result 264, Processing Time 0.025 seconds

Natural Convection in Concentric Annuli with the Nonuniform Temperature Distribution of the Inner Cylinder (내관의 온도가 불균일한 동심환상공간에서의 자연대류)

  • 김찬원;권순석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1012-1022
    • /
    • 1989
  • Numerical analysis has been performed on three-dimensional natural convection in inclined concentric annuli with the nonuniform temperature distribution of the inner cylinder. The governing equations are numerically solved by successive over-relaxation methods for various inclination angles at $R_{a}$=3*10$^{4}$, $P_{r}$=7.0 and $r_{1}$ / $r_{2}$=0.6. Temperature and Nusselt number distributions are obtained and calculated results are compared with those of published uniform temperature distributions. It is found that the mean Nusselt numbers for the nonuniform temperature distributions increase more than those for the uniform temperature distributions by about 9. 6% at .delta.= 0.deg., 7.5% at .delta. = 30.deg. and 4.6% at .delta. = 60.deg.. In the case of .delta. = 0.deg., the maximum local Nusselt numbers on the inner and outer cylinder walls show at .xi. = 0.5, 1.5 of .psio=100 .deg. and .xi. = 0.4, 1.6 of .psi. = 180 .deg.. But in the case of .delta. = 30.deg. and .delta. = 60.deg., the maximum local Nusselt numbers on the inner and other cylinder walls show at .xt. = 0.0 of .psi. = 180 .deg. and .xi. = 2.0 of .psi. = 180 .deg...

An Overview of Marine Renewable Energy (해양 신재생에너지의 고찰)

  • Kim, Young C.
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.6
    • /
    • pp.433-438
    • /
    • 2013
  • With the prospect of an increasing shortage of energy resources, there has been a growing interest in renewable alternative sources of energy. An increasing effort is being directed towards resolving the problems of extracting energy from the world's oceans, as they represent a vast potential source of renewable energy. This paper summarizes the extraction and conversion techniques of the ocean's energy resources, namely, energy derived from the ocean waves, tides, thermal gradients, and currents. For each energy extraction and conversion technique, case studies are discussed.

A Study for the Mechanical Properties in Scouring and Heat Treatment of PLA Woven Fabric (PLA직물의 정련 및 열처리 시 물성변화에 대한 연구)

  • Kim, Ji-Yeon;Park, Sung-Min;Kang, Suk-Hee;Park, Jeong-Young;Yeom, Jeong-Hyeon
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2011.03a
    • /
    • pp.108-108
    • /
    • 2011
  • PLA 즉 폴리유산섬유는 옥수수를 발효하여 글루코오스(포도당)상태를 만든 후 젖산(유산, Lactic acid)으로 만들고 이것을 탈수, 축합반응시켜 polylactic acid로 만든 것이다. 생분해성이 있으므로 저탄소, 녹색성장의 모토를 대변하는 소재라는 이점이 있다. 구조는 에스테르기의 반복단위를 가지는 소수성 섬유로 벤젠환은 없으나 그 외 구조는 폴리에스테르와 비슷하며, 에스테르기가 존재하므로 분산염료와 수소결합하여 염착된다. 그러나 PLA는 융점이 $170^{\circ}C$, Tg $57^{\circ}C$로 내열성이 낮아서 염색온도, 열처리온도, 다림질에 제약이 있으며, 알칼리에 약한 단점이 있다. 따라서 PLA섬유는 낮은 염착량, 내알칼리성, 염착온도 때문에 염색 및 후가공 단계에 많은 사전 실험을 통한 조건 설정이 필요한 까다로운 섬유이다. 본 연구에서는 (주)휴비스의 PLA원사로 제직한 직물(경사:DTY 75/72SD, 위사:DTY 100/72SD, 조직:DOBBY) 생지에 대하여 열처리 시 장력의 유무, 온도, 시간에 따른 폭의 변화를 측정하여 수축률을 알아보았다. 또한, PLA직물을 온도별로 정련한 후 열처리하여 인열강도 측정을 통해 최적 전처리 조건을 조사하였다. 실험결과, PLA생지를 무장력 상태에서 열처리 시 수축이 심하게 일어나고, 장력이 주어져도 열처리 온도에 따라 수축의 정도에 차이가 나타났다. 열처리 시간은 30, 60, 90, 120초로 주었으나 큰 편차는 없었고, 경사가 위사보다 수축 정도가 더 컸으며, $130^{\circ}C$에서는 전체적으로 수축이 심하였다. 생지의 정련에는 인산에스테르계 정련제와 약알칼리인 탄산나트륨으로 조액하여 60, 70, 80, $90^{\circ}C$에서 10분간 처리한 후, Lab. tenter(Mathis, LTE)를 이용하여 110, 120, $130^{\circ}C$에서 30, 60, 90, 120초간 열처리한 다음, KS K 0535 펜듈럼법에 의거하여 인열강도를 측정하였다. 그 결과, 상기 정련온도에서는 인열강도에 영향을 주지 않았으나, 열처리 온도가 $130^{\circ}C$일 때 현저한 강도의 저하를 나타내었다. 실험조건 하에서 가장 적절한 열처리 조건은 $110^{\circ}C$, 60초로 사료된다. 따라서 PLA의 약한 내열성과 내알칼리성 실험결과, 강도나 수축 등 물성변화가 일어나지 않도록 열처리 온도의 제어에 주의가 필요함을 확인할 수 있었다. 실제 섬유가공 작업현장에서는 일반적으로 열처리기가 $180^{\circ}C$이상의 고온으로 고정된 경우가 많은데, 작업자들에게 PLA소재에 대한 사전주의 및 공정변경에 대한 주지가 요구된다.

  • PDF

Effects of Heat Temperature in Sizing and Pretreatment Processes on the Appearance Colour of the Polyester Fabrics (사이징 및 전처리 공정에서의 열처리 온도 변화에 따른 폴리에스테르 직물의 염색성 변화)

  • Cho, D.H.;Kim, S.J.;Chang, D.H.
    • Textile Coloration and Finishing
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • 이 연구에서는 사이징 공정을 포함해서 수세, 전처리 그리고 최종 열처리 둥의 염색.가공 공정에서의 습열 및 건열 처리 온도가 폴리에스테르 직물의 열응력과 염색성에 미치는 영향을 조사하였다. 사용된 폴리에스테르 필라멘트사는 경사가 50d/24f 스파크사이며 위사는 75d/72f semi-dull사이다. 평직물은 션틀직기, 주자직물은 water jet 직기로 제직하였으며, sizing dryer 온도는 $90^\circ{C}$, $125^\circ{C}$, $150^\circ{C}$, 수세공정의 습열처리 온도는 $90^\circ{C}$, $110^\circ{C}$, $120^\circ{C}$, 전처리 공정의 건열처리 온도는 $180^\circ{C}$, $200^\circ{C}$, $220^\circ{C}$, 마지막 세팅 공정의 건열처리 온도는 $170^\circ{C}$, $180^\circ{C}$, $200^\circ{C}$로 변화시켰다. 이들 습열과 건열처리 온도 변화에 따른 직물내의 필라멘트사의 열 수축률과 직물의 겉보기 염색성의 변화를 조사 분석하였다.

  • PDF

Numerical Study of Lightweight FRP Bridge Deck System Induced by Thermal Stress by Fire (화재 발생 시 열응력에 의한 복합재료 교량 시스템의 거동에 관한 연구)

  • Jung, Woo-Young;Park , Hee-Kwang;Park , Moon-Ho;Lee , Hyung-Kil
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.5
    • /
    • pp.211-217
    • /
    • 2006
  • This analysis evaluated small and large temperature gradient effects on the FRP deck considering lightweight of FRP deck and ply orientations at the interface between steel girders and FRP deck. Finally, the analytical results shows the possible failure mechanism of FRP deck under various temperature changes and its corresponding index is suddenly varied depending on the rapid change of temperature on the deck plate.

Long-term Tilt Prediction Model for the L-type Retaining Wall Adjacent to Urban Apartments (도심지 아파트 L형 옹벽의 장기 경사거동 예측모델)

  • Koo, Ki Young;Seong, Joo Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.6
    • /
    • pp.134-142
    • /
    • 2012
  • This paper presents a study of system identification on the tilt response of the L-type retaining wall located at Tanhyun 11th ACE Apartment, Ilsan in order to understand mechanism how the structure behaves in operational conditions and to provide a reference tilt values for assessing structural abnormality. The retaining wall was extraordinarily tall (14m) in urban area so the long-term monitoring system had been installed with 3 tilts-meters and 9 temperature sensors operational from Oct 2004 upto Nov 2007. By using 5-months continuous data in which all the 12 channels were up and running, the two prediction models, 1) the linear model, and 2) the state-space equation (SSE) model, have been identified by finding the best fitness model among all possible 511 combinations of input temperatures out of the 9 temperatures. The linear model which was simple in the model structure achieved the validation fittness of 68% due to the fact that the static model wasn't able to represent thermal dynamics. The SSE model achieved the validation fitness of 90% which was quite accurate considering various unexpected noises happening in field measurements.

An Experimental Study on the Critical Velocity Considering the Slope in Tunnel Fire (경사터널내 화재 발생시 경사도가 임계속도에 미치는 영향에 관한 연구)

  • Kim, Seung-Ryoul;Jang, Yong-Jun;Ryou, Hong-Sun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • An experimental study has been conducted to investigate the effect of tunnel slope on critical velocity by using the model funnel of the 1/20 reduced-scale applying the Floods scaling law. the square liquid pool burners were used for methanol, acetone and n-heptane fires. tunnel. Tunnel slopes varied as five different degrees $0^{\circ}$, $2^{\circ}$, $4^{\circ}$, $6^{\circ}$ and $8^{\circ}$. The mass loss rate and the temperatures are measured by a load celt and K-type thermocouples for tunnel slope. Present study results in bigger the critical velocity than the research of Atikinson and Wu using the propane burner. Therefore, when estimating the critical velocity in slope tunnel, the variations of the heat release rate is an important factor. The reason is the ventilation velocity directly affects variation of heat release rate when slope tunnel fire occurred.

Thermomechanical Analysis of Functionally Gradient $Al-SiC_p$ Composite for Electronic Packaging (전자패키지용 경사조성 $Al-SiC_p$복합재료의 열.기계적 변형특성 해석)

  • 송대현;최낙봉;김애정;조경목;박익민
    • Composites Research
    • /
    • v.13 no.6
    • /
    • pp.23-29
    • /
    • 2000
  • The internal residual stresses within the multilayered structure with sharp interface induced by the difference in thermal expansion coefficient between the materials of adjacent layers often provide the source of failure such as delamination of interfaces etc. Recent development of the multilayered structure with functionally graded interface would be the solution to prevent this kind of failure. However a systematic thermo-mechanical analysis is needed for the customized structural design of multilayered structure. In this study, theoretical model for the thermo-mechanical analysis is developed for multilayered structures of the $Al-SiC_p$ functionally graded composite for electronic packaging. The evolution of curvature and internal stresses in response to temperature variations is presented for the different combinations of geometry. The resultant analytical solutions are used for the optimal design of the multilayered structures with functionally graded interface as well as with sharp interface.

  • PDF

Effect of Positive Pressure Ventilator Tilting Angle on the Flame Suppression and Smoke Density (Positive Pressure Ventilator 경사각 변화에 의한 화염억제 효율과 연기농도 변화)

  • Kim, Sung-Won;Lee, Kyoung-Duck;Shin, Chang-Sub
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.135-142
    • /
    • 2006
  • The experiment applied Positive Pressure Ventilation to rapidly exhaust heat and smoke inside the construction in the fire was done. Changes of heat discharge and smoke density were measured, with the various blowing condition like a fan tilting angle to find the effect of the parameter. Experimental apparatus were with PPV and water mist system for better efficiency, and investigate the effect of heat discharge and smoke removal. In the experiment, flame temperature has decreased when PPV was applied. Smoke density, generated from fire also decreased dramatically and the efficiency showed the highest rate at $0^{\circ}$ tilting angle. In addition, combination of PPV and water mist system highly improved the efficiency of evacuation on heat and smoke density, clearly was influenced by the tilting angle.