• Title/Summary/Keyword: 온도감시

Search Result 264, Processing Time 0.035 seconds

A Fault Detection Method for Solenoid Valves in Urban Railway Braking Systems Using Temperature-Effect-Compensated Electric Signals (도시철도차량 제동장치의 솔레노이드 밸브에 대한 전류기반 고장진단기법 개발)

  • Seo, Boseong;Lee, Guesuk;Jo, Soo-Ho;Oh, Hyunseok;Youn, Byeng D.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.835-842
    • /
    • 2016
  • In Korea, urban railway cars are typically maintained using the strategy of predictive maintenance. In an effort to overcome the limitations of the existing strategy, there is increased interest in adopting the condition-based maintenance strategy. In this study, a novel method is proposed to detect faults in the solenoid valves of the braking system in urban railway vehicles. We determined the key component (i.e., solenoid valve) that leads to braking system faults through the analysis of failure modes, effects, and criticality. Then, an equivalent circuit model was developed with the compensation of the temperature effect on solenoid coils. Finally, we presented how to detect faults with the equivalent circuit model and current signal measurements. To demonstrate the performance of the proposed method, we conducted a case study using real solenoid valves taken from urban railway vehicles. In summary, it was shown that the proposed method can be effective to detect faults in solenoid valves. We anticipate the outcome from this study can help secure the safety and reliability of urban railway vehicles.

Sensing Characteristics of $SnO_{2}$ type CO sensors for combustion exhaust gases monitoring (연소배가스 모니터링을 위한 $SnO_{2}$계 CO센서의 검지특성)

  • Kim, I.J.;Han, S.D.;Lim, H.J.;Son, Y.M.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.369-375
    • /
    • 1997
  • $V_{2}O_{5}/ThO_{2}/Pd$-doped $SnO_{2}$ sensor has a good selectivity and stability to CO at high sensor temperature of about $500^{\circ}C$, and shows rapid response. In particular, many kinds of interference gases, such as $NO_{x}$, $C_{3}H_{8}$, $CH_{4}$ and $SO_{2}$ have been found to give only a slight influence on the sensor selectivity to CO gas sensitivity by doped $V_{2}O_{5}$ (3.0 wt.%). For the sensor we used well-known thick film technological route with $V_{2}O_{5}$(3.0 wt.%), Pd(1.0 wt.%) and $ThO_{2}$(l.5 wt.%) as catalytic materials. In the case of mixed $NO_{x}$-CO gases, as combustion exhaust gas, only CO detection by $SnO_{2}$ type semiconductor sensor is generally very difficult because of $NO_{x}$ interference. The developed sensors can use to measure the exhausting gas of the automobile or the boiler for the Air-to-Fuel ratio control.

  • PDF

Fiber Optic Bragg Grating Sensor for Crack Growth Detection of Structures (구조물의 균열 진전 탐지를 위한 광섬유 브래그 격자 센서)

  • Kwon, Il-Bum;Seo, Dae-Cheol;Kim, Chi-Yeop;Yoon, Dong-Jin;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.299-304
    • /
    • 2007
  • There are to be some cracks on the material degradation part or the stress concentration parts of the main members, which carry on over-loads, of structures. Because these cracks can be used to evaluate the structural health status, it is important to monitor the crack growth for maintaining the structural safety. In this study, the fiber Bragg grating sensor with a drop ball was developed as a sensor for crack growth detection of an existing crack. The crack growth detection sensor was constructed with three parts: a probe part, a wavelength controling light source and receiver part, and an impact part. The probe part was just formed with a fiber Bragg grating optical fiber The wavelength controling light source part was composed of a current supplying circuit, a DFB laser diode, and a TEC controling circuit for wavelength control. Also, the impact part was just implemented by dropping a steel ball. The performance of this sensor was confirmed by the experiments of the crack detection with an aluminum plate having one existing crack. According to these experiments, the difference of the sensor signal outputs was correlated with the crack length. So, it was confirmed that this sensor could be applied to monitor the crack growth.

Remote control system for management of a stall using PDA (PDA를 이용한 축사관리 원격제어 시스템)

  • Kim, Tae-Soo;Chun, Joong-Chang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.1010-1013
    • /
    • 2009
  • The youths of the farming village have moved to the metropolis, thus the most of the manpower which engages to a production remained in the village reaches layer old age and all thing sprouts long the whole and it is one. So to remove the waste of barn rather than to give feed to the livestock is hard that what step all automation of this part is necessary. Consequently we have developed the automation system in order to reduce the massive death of the livestock at the time of intense cold and hot. The system will be able to clean the waste of the barn and confront quickly in the change of temperature which is sudden it came. And we proposed also the system that will be able to watch at real-time and monitor the operational environment from a remote using CCD camera. In this paper, we proposed the remote control system which uses PDA in order to control the automation system of a stall while moving. The proposed system was embodied in order for the control and the monitor while the user is mobile using PDA screens. We also added a protection system in that system. The system sends the case warning and SMS while will have the fire and the intrusion from the outside and prevents a robbery.

  • PDF

The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology (가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발)

  • Park, Chan Il;Yoo, Kee-Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.27-38
    • /
    • 2021
  • We devised the system to automatically shutdown the boiler and to fundamentally block the harmful gases, including carbon monoxide, into the indoor when the exhaust system swerves: (1) The discharge pressure of the exhaust gas decreases when the exhaust pipe is disconnected. The monitoring system of the exhaust pipe is implemented by measuring the output voltage of APS(Air Pressure Sensor) installed to control the amount of combustion air. (2) The operating software was modified so that when the system recognizes the fault condition of a flue pipe, the boiler control unit displays the fault status on the indoor regulator while shutting down the boiler. In accordance with the ventilation facility standards in the "Rules for Building Equipment Standards" by the Ministry of Land, Infrastructure and Transport, experiments were conducted to ventilate indoor air. When carbon monoxide leaked in worst-case scenario, it was possible to prevent poisoning accidents. However, since 2013, the number of indoor air exchange times has been mitigated from 0.7 to 0.5 times per hour. We observed the concentration exceeding TWA 30 ppm occasionally and thus recommend to reinforce this criterion. In conclusion, if the flue pipe fault detection and the indoor air ventilation system are introduced, carbon monoxide poisoning accidents are expected to decrease significantly. Also when the manufacturing and inspection steps, the correct installation and repair are supplemented with the user's attention in missing flue, it will be served to prevent human casualties from carbon monoxide poisoning.

Proper Monitoring Methods for Safety Management of Tailings Dam (광물찌꺼기적치장의 안전관리를 위한 적정 모니터링 방안 연구)

  • Jung, Myung Chae;Kim, Jeong Wook;Hwang, In-ho;Yang, In Jae;Park, Jay Hyun;Park, Ju Hyun;Kim, Tae Youp
    • Journal of the Korean Society of Mineral and Energy Resources Engineers
    • /
    • v.55 no.6
    • /
    • pp.576-587
    • /
    • 2018
  • This study has focused on analysis factors affecting safety monitoring system at tailings sites, and the evaluation equipment to monitor the factors. Twenty sites at eighteen mines with unsafe conditions were selected to examine the equipment. There were three main factors influenced safety in the sites including surface erosion, piping, and slope instability. In detail, the surface erosion was divided into three sub-factors (planting, soil-topping layer, and tailings), piping into three sub-factors (liner, rain protection facility and leachate), and slop instability was also divided into three sub-factors (slop, concrete wall, and reinforcing wall). As results of in-field measurement, a CCTV was the most effective facility, and electrical resistivity survey, acoustic sensing, thermal liner sensor, structure inclinometer, rainfall meter, and flowmeter were also highly effective. According to applications of the facilities in the unstable tailings, structural defects were mainly found in the piping, which was the most important monitoring factor for safety management of tailings sites.

Triple Junction GAGET2-ID2 Solar Cell Degradation by Solar Proton Events (태양 양성자 이벤트에 의한 삼중 접합 GAGET2-ID2 태양전지 열화)

  • Koo, Ja-Chun;Park, Jung-Eon;Moon, Gun-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.12
    • /
    • pp.1019-1025
    • /
    • 2021
  • In nearly all space environments, the solar cell degradation is dominated by protons[1]. Even through a GEO orbit lines in the electron radiation belts, the protons emitted from any solar event will still dominate the degradation[1]. Since COMS launch on June 26 2010, the proton events with the fluence of more than approximately 30 times the average level of perennial observations were observed between January 23 - 29 2012 and March 07 - 14 2012[16]. This paper studies the solar cell degradation by solar proton events in January and March 2012 for the open circuit voltage(Voc) of a witness cell and the short circuit current(Isc) of a section connected to a shunt switch. To evaluate the performance of solar cell, the flight data of voltage and current are corrected to the temperature, the Earth-Sun distance and the Sun angle and then compare with the solar cell characteristics at BOL. The Voc voltage dropped about 23.6mV compare after the March 2012 proton events to before the January 2012 proton events. The Voc voltage dropped less than 1% at BOL, which is 2575mV. The Isc current decreased negligible, as expected, in the March 2012 proton events.

Policies for Improving Thermal Environment Using Vulnerability Assessment - A Case Study of Daegu, Korea - (열취약성 평가를 통한 열환경 개선 정책 제시 - 대구광역시를 사례로 -)

  • KIM, Kwon;EUM, Jeong-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.2
    • /
    • pp.1-23
    • /
    • 2018
  • This study aims to propose a way for evaluating thermal environment vulnerability associated with policy to improve thermal environment. For this purpose, a variety of indices concerning thermal vulnerability assessment and adaptation policies for climate change applied to 17 Korean cities were reviewed and examined. Finally, 15 indices associated with policies for improving thermal environment were selected. The selected indices for thermal vulnerability assessment were applied to Daegu Metropolitan City of South Korea as a case study. As results, 15 vulnerability maps based on the standardized indices were established, and a comprehensive map with four grades of thermal vulnerability were established for Daegu Metropolitan City. As results, the area with the highest rated area in the first-grade(most vulnerable to heat) was Dong-gu, followed by Dalseo-gu and Buk-gu, and the highest area ratio of the first-grade regions was Ansim-1-dong in Dong-gu. Based on the standardized indices, the causes of the thermal environment vulnerability of Ansim-1-dong were accounted for the number of basic livelihood security recipients, the number of cardiovascular disease deaths, heat index, and Earth's surface temperature. To improve the thermal environment vulnerability of Ansim-1-dong, active policy implementation is required in expansion and maintenance of heat wave shelters, establishment of database for the population with diseases susceptible to high temperature environments, expansion of shade areas and so on. This study shows the applicability of the vulnerability assessment method linked with the policies and is expected to contribute to the strategic and effective establishment of thermal environment policies in urban master district plans.

Detection with a SWNT Gas Sensor and Diffusion of SF6 Decomposition Products by Corona Discharges (탄소나노튜브 가스센서의 SF6 분해생성물 검출 및 확산현상에 관한 연구)

  • Lee, J.C.;Jung, S.H.;Baik, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.66-72
    • /
    • 2009
  • The detection methods are required to monitor and diagnose the abnormality on the insulation condition inside a gas-insulated switchgear (GIS). Due to a good sensitivity to the products decomposed by partial discharges (PDs) in $SF_6$ gas, the development of a SWNT gas sensor is actively in progress. However, a few numerical studies on the diffusion mechanism of the $SF_6$ decomposition products by PD have been reported. In this study, we modeled $SF_6$ decomposition process in a chamber by calculating temperature, pressure and concentration of the decomposition products by using a commercial CFD program in conjunction with experimental data. It was assumed that the mass production rate and the generation temperature of the decomposition products were $5.04{\times}10^{-10}$ [g/s] and over 773 K respectively. To calculate the concentration equation, the Schmidt number was specified to get the diffusion coefficient functioned by viscosity and density of $SF_6$ gas instead rather than setting it directly. The results showed that the drive potential is governed mainly by the gradient of the decomposition concentration. A lower concentration of the decomposition products was observed as the sensors were placed more away from the discharge region. Also, the concentration increased by increasing the discharge time. By installing multiple sensors the location of PD is expected to be identified by monitoring the response time of the sensors, and the information should be very useful for the diagnosis and maintenance of GIS.

Long-term Climate Change Research Facility for Trees: CO2-Enriched Open Top Chamber System (수목의 장기 기후변화 연구시설: CO2 폭로용 상부 개방형 온실)

  • Lee, Jae-Cheon;Kim, Du-Hyun;Kim, Gil-Nam;Kim, Pan-Gi;Han, Sim-Hee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2012
  • The open-top chamber (OTC) system is designed for long term studies on the climate change impact on the major tree species and their community in Korea. In Korea Forest Research Institute (KFRI), the modified OTC system has been operating since September 2009. The OTC facility consists of six decagon chambers (10 meters in diameter by 7 meters high) with controlled gas concentration. In each chamber, a series of vertical vent pipes are installed to disperse carbon dioxide or normal air into the center of the chamber. The OTC is equipped with remote controlled computer system in order to maintain a stable and elevated concentration of carbon dioxide in the chamber throughout the experimental period. The experiment consisted of 4 treatments: two elevated $CO_2$ levels ($1.4{\times}$ and $1.8{\times}$ ambient $CO_2$) and two controls (inside and outdoors of the OTC). Average operational rate was the lowest (94.2%) in June 2010 but increased to 98% in July 2010 and was 100% during January to December 2011. In 2010~2011, $CO_2$ concentrations inside the OTCs reached the target programmed values, and have been maintained stable in 2011. In 2011, $CO_2$ concentrations of 106%, 100% and 94% of target values has been recorded in control OTC, $1.4{\times}$ $CO_2$-enriched OTC and $1.8{\times}$ $CO_2$-enriched OTC, respectively. With all OTC chambers, the difference between outside and inside temperatures was the highest ($1.2{\sim}2.0^{\circ}C$) at 10 am to 2 pm. Temperature difference between six OTC chambers was not detected. The relative humidity inside and outside the chambers was the same, with minor variations (0~1%). The system required the highest amount of $CO_2$ for operation in June, and consumed 11.33 and 17.04 ton in June 2010 and 2011, respectively.