• Title/Summary/Keyword: 오차율

Search Result 1,696, Processing Time 0.034 seconds

Determination of Transferring Period of Several Plants using Image Processing (영상처리를 이용한 작물의 모종시기 결정)

  • 민병로;김웅;김동우;이대원
    • Journal of Bio-Environment Control
    • /
    • v.13 no.3
    • /
    • pp.178-184
    • /
    • 2004
  • This study carried out to develope the vision system which automatically finds out a optimum transferring period of plants (Perilla, Platycodon grandifloums and Lactuca sativa) by using image process-ing. This system mearsured a height, long diameter and short diameter of the three plants with 20 replications. Following results were obtained on each plant. Compared with real data to be measured by hand with the vernier calipers, height, long diameter and short diameter of Perilla showed 0.5 mm average error rate with 1.7%, 4.7 mm average error rate with 3.9% and 5.5 mm average error rate with 6.9% respectively. Those of Platycodon grandifloums showed 2.4 mm with 8.1%, 3.4 mm with 7.2% and 4.0 mm with 10.4% respectively. Those of Lactuca sativa showed 4.0 mm with 9.1 %,3.4 mm with 7.2% and 3.6 mm with 9.4% respectively. The system could be used to transfer accurately the plant seedling, if the system were improved enough to reduce error rate for the optimum transferring period of a plant in the greenhouse.

A Study on the Accuracy of Traffic Demand Forecasting in National Highway (일반국도의 교통수요 예측 정확도 연구)

  • Jeon, Woo-Hoon;Lim, Kang-Won;Cho, Hye-Jin
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.61-70
    • /
    • 2010
  • The purpose of this study is to analyze the accuracy of traffic volume forecast by comparing an estimated to real traffic volume. For this study, total 10 sections of national highways, which are planned in 1980s and 1990s, were selected and traffic analysis data for highway construction were collected. In addition, targeted 10 sections were categorized into network-related and -unrelated sections. In the analysis of inaccuracy between the estimated and real traffic, for network-related sections, appeared to have lower inaccuracy. As time goes on after traffic open, inaccuracy between the estimated and real traffic appeared to be lower. In various section lengths, the longer the section length, the higher the inaccuracy is. Using 3 years passed data after traffic open, national highway have lower inaccuracy than expressway. However, the traffic analysis according to traffic open time resulted in little change of the inaccuracy.

The Load Forecasting in Summer Considering Day Factor (요일 요인을 고려한 하절기 전력수요 예측)

  • Han, Jung-Hee;Baek, Jong-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2793-2800
    • /
    • 2010
  • In this paper, we propose a quadratic (nonlinear) regression model that forecasts daily demands of electric power in summer. For cost-effective production (and/or procurement) of electric power, forecasting demands of electric power with accuracy is important, especially in summer when temperature is high. In the literature, temperature and daily demands of preceding days are typically employed to construct forecasting models. While, we consider another factor, day of the week, together with temperature and daily demands of preceding days. For validating the proposed model, we demonstrate the forecasting accuracy in terms of MAPE(Mean Absolute Percentage Error) and MPE(Maximum Percentage Error) using field data from KEPCO(Korea Electric Power Corporation) in comparison with two forecasting models in the literature. When compared with the two benchmarks, the proposed forecasting model performs far better providing MAPE and MPE not exceeding 3.08% and 8.99%, respectively, in summer from 2005 to 2009.

Error rate analysis of Surface Image Velocimeter(SIV) according to the reference point (참조점 설정에 따른 표면영상유속계(SIV)의 오차율 분석)

  • Kim, Yong seok;Yang, Sung kee;Jung, Woo yul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.534-538
    • /
    • 2016
  • 2012년 9월 17일 제 16호 태풍 산바의 내습에 의한 유출발생 시 제주도 천미천 유역의 성읍교 부근에서 최대 수위 3.94 m를 기록한 9시 00분 유출영상에 표면영상유속계(SIV)를 적용하여 참조점 설정에 따른 오차율을 분석하였다. 참조점 설정 과정에서 원거리의 참조점 입력 오류가 발생하면 2~11 pixel의 미세한 오류값 입력에 의해 X축 방향으로 0.42 m, Y축 방향으로 0.94 m의 실거리 변화율이 발생하며, 근거리의 참조점 입력 오류가 발생하면 1~11 pixel의 미세한 오류값 입력에 의해 X축 방향으로 0.02 m, Y축 방향으로 0.28 m의 실거리 변화율을 발생시킨다. 이 같은 실거리 변화율은 원거리의 참조점 설정변수에 따라 유속 오차율은 최소 16.77%에서 최대 317.69%의 변동 폭을 나타냈으며, 유량 산정 시 최소 16.86%에서 최대 338.63%의 변동 폭을 나타냈다. 또한 근거리의 참조점 설정변수에 따라 유속 오차율은 최소 1.10%에서 최대 74.47%의 변동 폭을 나타냈으며, 유량 산정 시 최소 0.82%에서 최대 59.28%의 변동 폭을 나타냈다.

  • PDF

Exact BER Expressions for Decode-and-Forward Relaying in Rayleigh Fading Channels (레일레이 페이딩 채널에서 디코팅 후 전달 중계방식에 대한 비트 오차율 분석)

  • Lee, In-Ho;Kim, Dong-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1244-1250
    • /
    • 2007
  • User cooperation provides high reliability in wireless communication systems by employing relay nodes to transmit the same information. In this paper, a bit error rate (BER) study is presented for decode-and-forward (DF) relaying for user cooperation in independent and identically distributed Rayleigh fading channels. For an arbitrary number of relays, exact and closed-form expressions of the BER are proposed for M-ary PAM (Pulse Amplitude Modulation), QAM (Quadrature Amplitude Modulation) and PSK (Phase Shift Keying), respectively. It is also shown that the analytic results are perfectly matched with the simulated ones.

A Research for Improvement of WIM System by Abnormal Driving Patterns Analysis (비정상 주행패턴 분석을 통한 WIM 시스템 개선 연구)

  • Park, Je-U;Kim, Young-Back;Chung, Kyung-Ho;Ahn, Kwang-Seon
    • Journal of Internet Computing and Services
    • /
    • v.11 no.4
    • /
    • pp.59-72
    • /
    • 2010
  • WIM(Weigh-In-Motion) is the system measuring the weight of the vehicle with a high-speed. In the existing WIM system, vehicle weight is measured based on the constant speed and the error ratio has 10%. However, because of measuring the driving pattern, that is abnormal driving pattern which is like the acceleration and down-shift of the drivers, it has the error ratio which is bigger than the real. In order to it reduces the error ratio of WIM system, the improved WIM system needs to find the abnormal driving pattern. In order to reducing the error ratio of these WIM systems, the improved WIM system can find abnormal driving patterns. In this paper, the improved WIM system which analyzes the abnormality driving pattern influencing on the error ratio of WIM system of an existing and minimizes the error span is designed. The improved WIM system has the multi step loop structure of adding the loop sensor to an existing system. In addition, the measure function defined as an intrinsic is improved and the weight measured by the abnormal driving pattern is amended. The analysis of experiment result improved WIM system can know the fact that the error span reduces by 8% less than in the existing the maximum average sampling error 22.98%.

Improvement of Bit Rate Using Concentration of the Distribution of Prediction Errors (예측오차 분포의 집중화를 이용한 비트율 개선)

  • 김형철
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06e
    • /
    • pp.207-210
    • /
    • 1998
  • 기존의 DPCM에 의한 압축방법은 예측오차를 양자화하여 전송한 후 복원하는 것으로 8레벨로 양자화하는 경우 3bpp의 비트율을 갖는다. 본 논문에서는 화소값의 압축에 의해 기존의 DPCM보다 예측오차값의 분포를 0을 중심으로 더 집중시킴으로써 더 낮은 비트율을 갖는 압축방법을 제안한다. 압축된 각 화소의 예측오차값은 DPAM방법에 의해 8-레벨로 양자화되고, 양자화된 예측오차의 열을 4와 2 단위로 분할하여 예측오차의 학습된 열로 구성된 각각의 코드북과 비교한다. 비교 결과 코드북의 주소를 생성하여 전송하고, 복원시 화소값을 확장한다. 제안된 방법은 DPCM방법보다 2.4~4.06dB 낮은 복원 영상의 화질을 보이지만, 비트율은 2.17~2.34bpp를 얻음으로써 0.66~0.83bpp정도 개선할 수 있다.

  • PDF

A Stability Study of Three Open-Ended Coaxial Probe Conversion Models under the Error Situations (오차에 대한 3가지 개방단말 동축선 프로브의 환산모델들간 안정성 연구)

  • 조유선;현승엽;김상욱;김세윤
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.300-303
    • /
    • 2001
  • 개방단말 동축선 프로브는 임의의 매질에 접촉하여 복소 유전율을 구하므로 사용이 용이한 측정법이다. 복소 유전율의 측정 과정은 두 단계로 구성된다. 먼저 프로브의 개구면을 미지의 매질에 접촉시켜서 반사계수를 측정한다. 다음에는 반사계수를 환산모델에 대입하여 복소 유전율을 구한다. 그러나 실제 측정시 발생하는 오차들에 대해 취약하다는 단점을 가지고 있다. 정확성을 떨어뜨리는 주요 오차 요인으로는 프로브의 개구면과 측정매질 사이의 공극으로 인한 불완전 접촉오타와 프로브의 제작 한계로 인한 오차를 들 수 있다. 본 논문에서는 이런 오차상황에서 유한 차분 시간영역법으로 반사계수를 계산하고나서 환산모델에 의해 복소 유전율로 환산함으로써 오차에 대한 환산모델들간의 안정성을 살펴보고자 한다.

  • PDF

Comparison on the Error Rates of Calibration Modes in Intervention (인터벤션에서 Calibration Mode에 대한 오차율 비교)

  • Kong, Chang gi;Ryu, Young hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.619-626
    • /
    • 2020
  • This study aimed to identify the error rates in Catheter Calibration Mode, Auto Calibration Mode, and Segment Calibration Mode among many calibration modes as a quantitative evaluation tool used for predicting the diameter and length of balloon or stent in percutaneous intravascular balloon dilatation or stent insertion. Our experiment was conducted with Copper Wire of 2 mm × 80 mm (diameter × length) manufactured elaborately for quantitative evaluation in calibration and Metal Ball of 5, 10, 15, 30, and 40 mm and Acryl Phantom of 25 mm, 50 mm, 75mm, 100 mm, 125 mm, 150mm, 175 mm, and 200 mm. At each height, subtraction images were acquired with a cineangiograph and Stenosis Analysis Tool as a software provided by the equipment company was used for measurement. To evaluate the error rates in Catheter Calibration Mode, Copper Wire was put on each acryl phantom before shooting. Copper Wire of 2 mm in diameter was set as a diameter for catheter, and Copper Wire of 8 mm in length was measured with Multi-segments. As a result, the error rates appeared at 1.13 ~ 5.63%. To evaluate the error rates in Auto Calibration Mode, the height of acryl was entered at each height of acryl phantom and the length of 8 mm Copper Wire was measured with Multi-segments and as a result, the error rates appeared at 0 ~ 0.26%. To evaluate the error rates in Segment Calibration Mode, each metal ball on the floor of table was calibrated and the length of 8 mm Copper Wire on each acryl phantom was measured and the length of 8 mm Copper Wire depending on the changes of acryl phantom height was measured with Mutli-segments and as a result, the error rates appeared at 1.05 ~ 19.04%. And in the experiment on OID changes in Auto Calibration Mode, the height of acryl phantom was fixed at 100mm and OID only changed within the range of 450 mm ~ 600 mm and as a result, the error rates appeared at 0.13 ~ 0.38%. In conclusion, it was found that entering the height values in Auto Calibration Mode, among these Calibration Modes for evaluating quantitative vascular dimensions provided by the software was the calibration method with the least error rates and it is thus considered that for calibration using a metal ball or other objects, putting them in the same height as that of treatment sites before calibrating is the method that can reduce the error rates the most.

Improvement of Bit Rate by Removing the Repeated Sequences of Prediction Errors (예측오차 열의 중복성 제거에 의한 비트율 개선)

  • 김형철;조제황
    • The Journal of the Acoustical Society of Korea
    • /
    • v.17 no.8
    • /
    • pp.68-72
    • /
    • 1998
  • 본 논문에서는 기존의 DPCM에 의한 압축방법보다 더 낮은 비트율을 갖는 압축방 법을 제안한다. 각 화소의 예측오차 값은 DPCM방법에 의해 양자화되고, 양자화된 예측오차 의 열은 예측오차의 학습된 열로 구성된 코드북과 비교된다. 비교과정은 벡터양자화 방법과 동일하고, 그 결과 코드북의 주소를 생성한다. 제안된 방법은 DPCM과 동일한 복원 영상의 화질을 보이지만, 더 낮은 비트율을 얻을 수 있다.

  • PDF