Effects of Ozone Treatment to Pig Liquid Manure on Reduction of Odorous Gases (돈분뇨 액비의 악취저감을 위한 오존처리 효과)

  • Jeong, J.W.;Yoo, Y.H.;Park, K.H.;Kam, D.H.;Choi, H.J.;Kim, T.I.;Cho, Y.S.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.161-170
    • /
    • 2007
  • Ozone from a pilot-scale ozone generator was treated on fermented pig liquid manure stored in a storage tank in order to reduce odor substances during the process of fermented liquid manure production. The group of ozone treatment showed one less than the organic matter compared that of the control. The preferable condition for characteristic changes was when the ratio of BOD to COD was less than 1.5. Ozone treatment showed better oxidizing power than control as it removed more suspended solids and had less methyl isobutyl ketone(P<0.05). Odor reduction measured by olfactory method was higher in ozone treatment than in control.

  • PDF

Decomposition Characteristics of Bisphenol A by a Catalytic Ozonation Process (오존촉매산화공정에 의한 비스페놀 A의 분해특성)

  • Choi, Jae Won;Lee, Hak Sung
    • Applied Chemistry for Engineering
    • /
    • v.26 no.4
    • /
    • pp.463-469
    • /
    • 2015
  • Bisphenol A (BPA) in aqueous solution was measured using HPLC technique, which was established by acetonitrile analysis and KDP solution analysis methods. In these experiments the decomposition characteristics of BPA were compared using the ozone alone, ozone/pH 10, and ozone/hydrogen peroxide processes. About 70% of 10 mg/L of BPA was removed during 60 min by the ozone alone process, while 10 mg/L of BPA was completely removed by the ozone/pH 10 and ozone/hydrogen peroxide processes in 40 min and 60 min, respectively. The final decomposition efficiency drawn from results of TOC and HPLC analyses showed that the ozone/hydrogen peroxide process was the best among them, whereas the concentrations of TOC and reaction intermediates when using the ozone/pH 10 process were higher than those of the ozone alone process after 60 min of reaction. The ozone/hydrogen peroxide process was the most efficient among them when oxidizing organic carbons in water to $CO_2$ and $H_2O$.

A study on the Ozone oxidation of Diesel-contaminated Groundwater (디젤로 오염된 지하수의 오존산화처리에 대한 연구)

  • 권충일;공성호;김무훈
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.3-15
    • /
    • 2001
  • The ozone kinetics including ozone auto-decomposition. effect of pH, and solubility were investigated. Diesel decomposition process including TCE & PCE decomposition. effect of hydroxyl radical scavenger, effect of pH, and ozone/$H_2O$$_2$by ozonation process were also examined using deionized water, simulated groundwater. and actual groundwater. Reactions with deionized water and groundwater both stowed the second-order reaction rates, and the reaction rate was much higher in groundwater (half-life of 14.7 min) than in deionized water (hal(half-life of 37.5 min). The reaction rate was accelerated at high pH values in both waters. The use of ozone showed high oxidation rates of TCE. PCE and diesel. Though hydroxyl radical scavengers existing in groundwater were inhibitors for treating diesel, high pH condition and addition of hydrogen peroxide could accelerate to degrade diesel in groundwater, indicating ozone oxidation process could be applied to treating diesel contaminated-groundwater.

  • PDF

Effect of Ozone Treatment on Dyeability of Polyethylene Film (오존 처리가 폴리에틸렌 필름의 염색성에 미치는 영향)

  • 박수진;신준식;김학용;이덕래
    • Polymer(Korea)
    • /
    • v.27 no.2
    • /
    • pp.98-105
    • /
    • 2003
  • The surface energy and the effect of functional groups on the surface of the ozone-treated low-density polyethylene (LDPE) film were studied. Treatment conditions were treatment time, total amount of transferred ozone, and ozone concentration. The introduction of polar groups on the surface of LDPE film after ozone treatment was confirmed by FTIR-ATR and XPS analyses. Surface fee energy of the LDPE film was examined by a contact angle method. The ozone treated-LDPE film showed a decreased water contact angles about 15$^{\circ}$ mainly due to the increased concentration of oxygen-containing functional groups, which was attributed to the increased surface free energy or $O_{IS}/C_{IS}$Also, the concentrations of the oxygen-containing functional groups on the surface of LDPE film increased with ozone treatment time and concentration, whereas no significant effects were found for the total amount of transferred ozone. From the dyeability test using Kubelka-Munk equation, it was found that the ozone treatment plays an important role in the growth of oxygen-containing functional groups of LDPE film, resulting in the improvement of dyeability for basic dyeing agent.

Temporal and Spatial Variability of the TOMS Total Ozone; Global Trends and Profiles (TOMS 오존전량의 시공간 변동; 전구적인 추세 및 연직 분포)

  • Yoo Jung-Moon;Jeong Eun-Joo
    • Journal of the Korean earth science society
    • /
    • v.26 no.3
    • /
    • pp.199-217
    • /
    • 2005
  • Using monthly total ozone data obtained from a Total Ozone Mapping Spectrometer (TOMS) onboard the Nimbus-7 and Earth Probe satellite, this study examined the trend in the total amount of global ozone during two periods: from 1979-1992 [Early period] and 1997-2002 [Latter period]. The Annual average of total ozone during the Early period was globally reduced by about 10 DU compared to the amount during the Latter, except in some areas between the equator and 20 N. Global trends of total ozone showed a decrease of -6.30 DU/decade during 1979-1992, and an increase of 0.12 DU/decade during 1997-2002. Its enhancement during the Latter period was especially noticeable in tropical areas. The EOF analyses of total ozone from this period indicated signs of temporal/spatial variability, associated with the phenomena of Quasi-Biennial Oscillation (QBO), Quasi-Triennial Oscillation (QTO), El Nino Southern Oscillation (ENSO), and volcanic eruption. Seasonal profiles of tropospheric ozone in the tropics obtained from ozonesondes, showed the spatial pattern of zonal wavenumber one. Overall, this study may be useful in analyzing possible causes in the variations of statospheric and tropospheric ozone.

Al2O3 산화막 방전관을 통한 개선된 오존발생장치에 관한 연구

  • Lee, Seong-Ho;Min, Jeong-Hwan;Gong, Seong-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.457-457
    • /
    • 2014
  • 오존발생방법은 다양한 방식으로 구현이 가능하나 대용량 장치를 만들기 위해서는 DBD (Dielectric barrier discharge) 구조의 형태의 가지고 있다. 이러한, DBD는 반도체의 MOS (Metal On Semiconductor)의 반대 구조를 가진 SOM (Semiconductor On Metal)의 형태를 가지고 있으며 대부분이 Oxidation 산화물을 가지고 구현한다. 오존발생기는 반도체 공정, 환경 및 정화 등 다양한 분야에 사용이 되고 있는 상황으로 성능개선을 위한 연구가 필요한 상황이다. 대표적으로 사용되는 물질인 $SiO_2$를 가지고 있는 상황이며 Silicon은 에너지 Bandgap이 1.1 eV로 금속위에 증착되어 통상적으로 사용되는 문턱전압은 0.7 V에 해당이 된다. 현재 점차적으로 연구가 진행되고 있는 $Al_2O_3$는 8.8 eV의 bandgap을 가지고 있으며 유전 상수가 9로 $SiO_2$인 3.9보다 높은 유전률 특징을 가지고 있다. 따라서, 본 연구는 오존 발생장치에 사용되는 방전관을 기존의 $SiO_2$에서 $Al_2O_3$ 방식으로 대체하므로써 실제적인 유전율의 값의 차이와 오존 발생시 오존변화율 증대에 관하여 연구하였다. $SiO_2$ 방전관은 Fe 메탈위에 약 3 mm정도의 두께를 binding시켜 N4L사의 PSM1700 모델 LCR meter를 사용하여 1.3 kHz시 7.2 pF의 유전율 확인 할 수 있으며 동일한 조건의 금속 메탈위에 $Al_2O_3$를 binding 시켜 측정한 결과 1.07 kHz시 10.7 pF의 유전율을 가지게 되어 40% 이상 높은 유전율을 가지게 되는 것을 확인 할 수 있다. 오존발생을 위하여 가변 주파수형 트랜스 드라이버를 통한 공진 주파수를 생성하여 방전 증폭을 위한 Amplifier를 통하여 변환률을 높이는 방식을 적용하여 MIDAC사의 I1801모델 적외선 분광기(FT-IR)를 통한 오존발생량을 측정하여 기존의 $SiO_2$의 방전관은 시간당 54 g의 오존 발생률 가지게 된다. $Al_2O_3$는 시간당 70 g 정도의 오존 발생률 가지므로 기존의 $SiO_2$ 보다 발생률 높은 것을 확인 할 수 있다.

  • PDF

A Study on the Development of Bleaching efficiency for flex fabrics by Using Ozone Treatment (오존을 이용한 마직물의 표백성 향상에 관한 연구)

  • Lee, Mun-Soo;Song, Kyong-Hun;Kim, Gyoung-A;Song, Bong-Keun;Lee, Rae-Yohn
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • In order to study on the bleaching efficiency of flex fabrics, ozone which has been produced by an ozone generator, has been contacted with flex fabrics in water at various conditions. The equipments used for the ozone reatment of flex fabrics were the ozone generator and a liquor/ozone contactor. For the study of the bleaching efficiency on flex fabrics, the Hunter's whiteness, tensile strength, microscopic properties of the ozone treated flex fabrics were measured. The concentration of generated ozone was increased, as the voltage increase, flow ratio decrease and oxygen amount increase. The bleaching efficiency of ozone treated fabrics was increased with increasing the net concentration of ozone. The whiteness ozone of treated fabrics was found to be best when treated temperature was $0-15^{\circ}C$ and treated time was 20 min. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised.

  • PDF

Meteorological effects on high-ozone phenomena in June and modeling of ozone episode (서울지역 6월 고농도 오존 현상의 기상효과와 사레일 모델링)

  • 오인보;김유근;황미경;김동영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.141-142
    • /
    • 2003
  • 서울지역의 고농도 오존 현상은 초여름인 6월에 집중적으로 나타난다. 이러한 이유는 오존 생성에 적절한 기상조건이 형성되기 때문으로, 강한 일사량과 상대적으로 적은 강수빈도가 주된 원인임을 기존 여러 연구에서 밝히고 있다. 하지만 6월 고농도 현상의 보다 정확한 원인 해석을 위해서는 오존의 수송 및 도시 내 축적과정과 관련된 기상효과의 이해가 필요하며, 이는 종관장 패턴과 국지기상의 상호 유기적인 영향을 분석함으로서 가능하다. 또한 6월 고농도 현상은 봄철 성층권/상부대류권 오존의 연직수송과 관련한 특정 고농도 사례와는 달리 빈도 높은 서울의 전형적인 오존오염 형태로 볼 수 있으며, 6월 고농도 사례일의 오존 모델링을 통해 이를 정확히 이해할 필요가 있다. (중략)

  • PDF

Ozone kinetics and Diesel decomposition by Ozonation in Groundwater

  • Kwon, Choong-Il;Kong, Sung-Ho;Kim, Moo-Hoon
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.153-156
    • /
    • 2000
  • 본 연구에서는 지하수내에서의 오존의 거동과 오존산화공정에 의한 디젤의 분해를 조사하였다. 오존의 초순수와 지하수내에서의 반응은 모두 2차 분해반응속도식을 나타냈고, 초순수와 지하수내에서의 반감기는 각각 평균 37.5분, 14.7분으로 계산되었다. 지하수내에서 오존의 자가분해반응속도가 더 빠른 것으로 나타났는데 이는 오존이 지하수내에 존재하는 각종 유기·무기물질들과의 빠른 반응때문이라고 생각된다. 오존의 TCE, PCE 그리고 디젤의 빠른 제거효율을 통하여 디젤로 오염된 지하수를 처리하는데 있어서 오존산화공정은 효과적으로 적용될 수 있을 것이라 판단된다.

  • PDF

Implementation of Real Time Performance Measurement System of an Ozone Generator (오존 발생기의 실시간 성능 측정 시스템의 구현)

  • 최경업;김용철;김규식
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.239-242
    • /
    • 1999
  • 오존은 다른 산화제에 비해 산화력이 훨씬 높아 수처리에 많이 쓰인다. 본 논문에서는 오존 발생량, 오존 농도와 관계가 있는 주요 파라미터들의 손쉬운 제어를 위해 그래픽 사용자 인터페이스 모니터링 시스템을 구현하였다. 이 시스템은 Windows 98 환경의 PC에서 Turbo C와 LabVIEW를 사용하여 프로그램밍하며, 이 모니터링 시스템은 인버터를 제어하는 80196 Microprocessor와 양방향으로 통신한다. 본 연구에서는 모니터링 시스템이 가져야 할 오존 발생기 개발 단계에서 각 파라미터들의 최적값 결정과 오존 발생기 제조 단계에서 파라미터들의 조정이라는 두가지 목적에 적합하도록 그래픽 환경 사용자 인터페이스 구축에 그 초점을 맞추어 관리자가 효율적으로 오존 발생을 모니터링할 수 있게 한다.