• Title/Summary/Keyword: 오존

Search Result 1,978, Processing Time 0.036 seconds

Investigation of the Effects of Wavelength Range and Absorption Cross-Section on Sulfur Dioxide Slant Column Density Retrieval Using Ground-Based UV Scattered Sunlight Measurement (지상 기반 태양 UV 산란광 관측을 이용한 이산화황 경사칼럼농도 산출 시 파장 구간 및 흡수단면적에 따른 영향 조사)

  • Gyeong Park;Buju Gong;Minji Kim;Hanlim Lee
    • Korean Journal of Remote Sensing
    • /
    • v.40 no.4
    • /
    • pp.377-385
    • /
    • 2024
  • We investigated the effect of spectral fitting wavelength interval variations and selection of absorption cross-section on the sulfur dioxide slant column density (SCD) retrievals from the scattered sunlight observation using a UV-Vis hyperspectral instrument. The sulfur dioxide slant column densities were retrieved from the combinations of multiple spectral fitting intervals and absorption cross-sections. The observation was carried out at the site 0.53 km away from a combustion site located in Gimhae from December 1, 2023, to January 23, 2024. The radiances were obtained on the line of measurement sight toward the stack of the combustion facility. The best spectral fitting intervals were found to be from 305.7 to 321.1 nm. In terms of the absorption cross-section dependency, the SO2 (293 K), O3 (223 K, 243 K) show the best spectral fitting for the observed radiances with both the smallest fitting residual and SCD error. The effects of the fitting interval and cross sections found in this study can be useful information for improving SO2 retrievals based on UV hyperspectral measurements.

A brief review of recent Antarctic climate change (최근 남극의 기후변화 고찰)

  • Seong-Joong Kim;Chang-Kyu Lim
    • The Korean Journal of Quaternary Research
    • /
    • v.32 no.1_2
    • /
    • pp.30-40
    • /
    • 2018
  • In response to the increase in anthropogenic greenhouse gases, the Arctic temperature is increasing rapidly by 2-3 times other regions. This larger Arctic warming than lower latitudes is called 'Arctic Amplification'(Overland et al., 2017; Goose et al., 2018). Associated with the Arctic Amplification, the Arctic sea ice is declining rapidly and Greenland ice sheet is melting rapidly, especially around the coastal margins (State of Climate, 2018). However, Antarctic climate change appears to be different from the Arctic. In the western part of Antarctica, surface temperature is rising rapidly with large sea and land ice melting, but in the eastern part, there is little temperature change with slight increase in sea ice extent. The contrasting east-west temperature response is illustrated by the deepening of the Amundsen Sea Low whose upstream brings warm maritime air to the Antarctic peninsula and Amundsen-Bellingshausen Seas, but downstream air provides cold air to the Ross Sea, increasing sea ice. Besides, the increase in Southern Annular Mode (SAM) phase due to stratospheric ozone reduction enhances westerly winds, pushing sea ice northward by Ekman divergence and cooling east Antarctica. In this study, we review the recent Antarctic climate change and its possible causes.

Internalizing Environmental Cost using TDM Alternatives (교통수요관리 기법을 활용한 환경오염비용의 내부화 방안연구)

  • 김운수;엄진기;황기연;장지희
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.4
    • /
    • pp.99-110
    • /
    • 1999
  • With a growing awareness, transportation is the maior source of urban air pollution. Planners and policy-makers are strongly urged to care the impacts of transportation management strategies on environment. Since transport-related air Pollution can be regarded as negative externalities of transport, it is indispensable to evaluate chanties in air quality which seems to occur when proposed transport measures are implemented. In addition, transport measures should be integrated in a set of combined Paradigm regarding transport and environment. Based on the integrated Paradigm between transportation demand management(TDM) and environmental planning, the main focus is given to apply environment cost internalizing measures to the short-term congestion management Program(SCMP) in Seoul, that has been developed in 1998 by Seoul Development Institute. Three modules are analyzed: without and/or with ₩500, ₩1000 emission plus gas tax, respectively. From the empirical applications on Seoul city, one of the most exemplary findings in SCMP program is that, emission plus gas tax can be a very useful measure to reduce vehicular emissions by targeting major Pollutants differently, rather than by dealing with pollutants collectively. Further research that provides (1)showing the spatial variation of pollution levels along the intersections, (2)more developing combined Paradigm between transport, land use, and environment, (3)using environmental road capacity rather than Physical-aspects of road capacity, and (4)continuing R&D on air quality constrained TDM, can contribute significantly to applications of the real and efficient environment-constrained transportation planning.

  • PDF

Intercomparison of Shortwave Radiative Transfer Models for a Rayleigh Atmosphere (레일리 대기에서 단파 영역에서의 복사전달모델 결과들의 상호 비교)

  • Yoo, Jung-Moon;Jeong, Myeong-Jae;Lee, Kyu-Tae;Kim, Jhoon;Ho, Chang-Hoi;Ahn, Myoung-Hwan;Hur, Young-Min;Rhee, Ju-Eun;Yoo, Hye-Lim;Chung, Chu-Yong;Shin, In-Chul;Choi, Yong-Sang;Kim, Young Mi
    • Journal of the Korean earth science society
    • /
    • v.28 no.3
    • /
    • pp.298-310
    • /
    • 2007
  • Intercomparison between eight radiative transfer codes used for the studies of COMS (Communications, Ocean, and Meteorological Satellite) in Korea was performed under pure molecular, i.e., Rayleigh atmospheres in four shortwave fluxes: 1) direct solar irradiance at the surface, 2) diffuse irradiance at the surface, 3) diffuse upward flux at the surface, and 4) diffuse upward flux at the top of the atmosphere. The result (hereafter called the H15) from Halthore et al.'s study (2005) which intercompared and averaged 15 codes was used as a benchmark to examine the COMS models. Uncertainty of the seven COMS models except STREAMER was ${\pm}4%$ with respect to the H15, comparable with ${\pm}3%$ of Halthore et al.'s (2005). The uncertainty increased under a large $SZA=75^{\circ}$. The SBDART model generally agreed with the H15 better than the 6S model, but both models in the shortwave infrared region were equally good. The direct solar irradiance fluxes at the surface, computed by the SBDARTs of four different users, were different showing a relative error of 1.4% $(12.1Wm^{-2})$. This reason was partially due to differently installing the wavelength resolution in the flux integration. This study may be useful for selecting the optimum model in the shortwave region.

Environmental Impact Assessment of Rapeseed Cultivation by Life Cycle Assessment (전과정평가를 이용한 유채재배의 환경영향 평가)

  • Hong, Seung-Gil;Nam, Jae-Jak;Shin, Joung-Du;Ok, Yong-Sik;Choi, Bong-Su;Yang, Jae-E.;Kim, Jeong-Gyu;Lee, Sung-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • BACKGROUND: High input to the arable land is contributed to increasing productivity with causing the global environmental problems at the same time. Rapeseed cultivation has been forced to reassess its positive point for utilization of winter fallow field. The Objective of this study was performed to assess the environmental impact of rapeseed cultivation with double-cropping system in paddy rice on Yeonggwang district using life cycle assessment technique. METHODS AND RESULTS: For assessing each stage of rapeseed cultivation, it was collected raw data for input materials as fertilizer and pesticide and energy consumption rate by analyzing the type of agricultural machinery and working hours by 1 ton rapeseed as functional unit. Environmental impacts were evaluated by using Eco-indicator 95 method for 8 impact categories. It was estimated that 216 kg $CO_2$-eq. for greenhouse gas, 3.98E-05 kg CFC-11-eq. for ozone lazer depletion, 1.78 kg SO2-eq. for acidification, 0.28 kg $PO_4$-eq. for eutrophication, 5.23E-03 kg Pb-eq. for heavy metals, 2.51E-05 kg B(a)p-eq. for carcinogens, 1.24 kg SPM-eq. for smog and 6,460 MJ LHV for energy resource are potentially emitted to produce 1 ton rapeseed during its whole cultivation period, respectively. It was considered that 90% of these potential came from chemical fertilizer. For the sensitivity analysis, by increasing the productivity of rapeseed by 1 ton per ha, potential environmental loading was reduced at 22%. CONCLUSION(s): Fertilization affected most dominantly to the environmental burden, originated from the preuse stage, i.e. fertilizer manufacturing and transporting. It should be included and assessed an indirect emission, which is not directly emitted from agricultural activities. Recycling resource in agriculture with reducing chemical fertilizer and breeding the high productive variety might be contribute to reduce the environmental loading for the rapeseed cultivation.

The Variations of Stratospheric Ozone over the Korean Peninsula 1985~2009 (한반도 상공의 오존층 변화 1985~2009)

  • Park, Sang Seo;Kim, Jhoon;Cho, Nayeong;Lee, Yun Gon;Cho, Hi Ku
    • Atmosphere
    • /
    • v.21 no.4
    • /
    • pp.349-359
    • /
    • 2011
  • The climatology in stratospheric ozone over the Korean Peninsula, presented in previous studies (e.g., Cho et al., 2003; Kim et al., 2005), is updated by using daily and monthly data from satellite and ground-based data through December 2009. In addition, long-term satellite data [Total Ozone Mapping Spectrometer (TOMS), Ozone Monitoring Instrument (OMI), 1979~2009] have been also analyzed in order to deduce the spatial distributions and temporal variations of the global total ozone. The global average of total ozone (1979~2009) is 298 DU which shows a minimum of about 244 DU in equatorial latitudes and increases poleward in both hemispheres to a maximum of about 391 DU in Okhotsk region. The recent period, from 2006 to 2009, shows reduction in total ozone by 6% relative to the values for the pre-1980s (1979~1982). The long-term trends were estimated by using a multiple linear regression model (e.g., WMO, 1999; Cho et al., 2003) including explanatory variables for the seasonal variation, Quasi-Biennial Oscillation (QBO) and solar cycle over three different time intervals: a whole interval from 1979 to 2009, the former interval from 1979 to 1992, and the later interval from 1993 to 2009 with a turnaround point of deep minimum in 1993 is related to the effect of Mt. Pinatubo eruption. The global trend shows -0.93% $decade^{-1}$ for the whole interval, whereas the former and the later interval trends amount to -2.59% $decade^{-1}$ and +0.95% $decade^{-1}$, respectively. Therefore, the long-term total ozone variations indicate that there are positive trends showing a recovery sign of the ozone layer in both North/South hemispheres since around 1993. Annual mean total ozone (1985~2009) is distributed from 298 DU for Jeju ($33.52^{\circ}N$) to 352 DU for Unggi ($42.32^{\circ}N$) in almost zonally symmetric pattern over the Korean Peninsula, with the latitudinal gradient of 6 DU $degree^{-1}$. It is apparent that seasonal variability of total ozone increases from Jeju toward Unggi. The annual mean total ozone for Seoul shows 323 DU, with the maximum of 359 DU in March and the minimum of 291 DU in October. It is found that the day to day variability in total ozone exhibits annual mean of 5.7% in increase and -5.2% in decrease. The variability as large as 38.4% in increase and 30.3% in decrease has been observed, respectively. The long-term trend analysis (e.g., WMO, 1999) of monthly total ozone data (1985~2009) merged by satellite and ground-based measurements over the Korean Peninsula shows increase of 1.27% $decade^{-1}$ to 0.80% $decade^{-1}$ from Jeju to Unggi, respectively, showing systematic decrease of the trend magnitude with latitude. This study also presents a new analysis of ozone density and trends in the vertical distribution of ozone for Seoul with data up to the end of 2009. The mean vertical distributions of ozone show that the maximum value of the ozone density is 16.5 DU $km^{-1}$ in the middle stratospheric layer between 24 km and 28 km. About 90.0% and 71.5% of total ozone are found in the troposphere and in the stratosphere between 15 and 33 km, respectively. The trend analysis reconfirms the previous results of significant positive ozone trend, of up to 5% $decade^{-1}$, in the troposphere and the lower stratosphere (0~24 km), with negative trend, of up to -5% $decade^{-1}$, in the stratosphere (24~38 km). In addition, the Umkehr data show a positive trend of about 3% $decade^{-1}$ in the upper stratosphere (38~48 km).

Prediction of the risk of skin cancer caused by UVB radiation exposure using a method of meta-analysis (Meta-analysis를 이용한 UVB 조사량에 따른 피부암 발생 위해도의 예측 연구)

  • Shin, D.C.;Lee, J.T.;Yang, J.Y.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.1 s.60
    • /
    • pp.91-103
    • /
    • 1998
  • Under experimental conditions, UVB radiation, a type of ultra violet radiation, has shown to .elate with the occurrence of skin erythema (sun-burn) in human and skin cancer in experimental animal. Cumulative exposure to UVB is also believed to be at least partly responsible for the 'aging' process of the skin in human. It has also been observed to have an effect of altering DNA (deoxyribonucleic acid). UVB radiation is both an initiator and a promoter of non-melanoma skin cancer. Meta-analysis is a new discipline that critically reviews and statistically combines the results of previous researches. A recent review of meta-analysis in the field of public health emphasized its growing importance. Using a meta-analysis in this study, we explored more reliable dose-response relationships between UVB radiation and skin cancer incidence. We estimated skin cancer incidence using measured UVB radiation dose at a local area of Seoul (Shin chou-dong). The studies showing the dose-response relationships between UVB radiation and non-melanoma skin cancer incidence were searched and selected for a meta-analysis. The data for 7 reported epidemiological studies of three counties (USA, England, Australia) were pooled to estimated the risk. We estimated rate of incidence change of skin cancer using pooled data by meta-analysis method, and exponential and power models. Using either model, the regression coefficients for UVB did not differ significantly by gender and age. In each analysis of variance, non-melanoma skin cancer incidence after removing the gender and age and UVB effects was significant (p>0.01). The coefficients for UVB dose were estimated $2.07\times10^{-6}$ by the exponential model and 2.49 by the power model. At a local area of Seoul (Shinchon-Dong), BAF value were estimated 1.90 and 2.51 by the exponential and power model, respectively. The estimated BAP value were increased statistical power than that of primary studies that using a meta-analysis method.

  • PDF

A Meta-analysis of Ambient Air Pollution in Relation to Daily Mortality in Seoul, $1991\sim1995$ (메타분석 방법을 적용한 서울시 대기오염과 조기사망의 상관성 연구 (1991년$\sim$1995년))

  • Dockery, Douglas W.;Kim, Chun-Bae;Jee, Sun-Ha;Chung, Yong;Lee, Jong-Tae
    • Journal of Preventive Medicine and Public Health
    • /
    • v.32 no.2
    • /
    • pp.177-182
    • /
    • 1999
  • Objectives: To reexamine the association between air pollution and daily mortality in Seoul, Korea using a method of meta-analysis with the data filed for 1991 through 1995. Methods: A separate Poisson regression analysis on each district within the metropolitan area of Seoul was conducted to regress daily death counts on levels of each ambient air pollutant, such as total suspended particulates (TSP), sulfur dioxide $(SO_2)$, and ozone $(O_3)$, controlling for variability in the weather condition. We calculated a weighted mean as a meta-analysis summary of the estimates and its standard error. Results: We found that the p value from each pollutant model to test the homogeneity assumption was small (p<0.01) because of the large disparity among district-specific estimates. Therefore, all results reported here were estimated from the random effect model. Using the weighted mean that we calculated, the mortality at a $100{\mu}g/m^3$ increment in a 3-day moving average of TSP levels was 1.034 (95% Cl 1.009-1.059). The mortality was estimated to increase 6% (95% Cl 3-10%) and 3% (95% Cl 0-6%) with each 50 ppb increase for 9-day moving average of SO2 and 1-hr maximum O3, respectively. Conclusions: Like most of air pollution epidemiologic studies, this meta-analysis cannot avoid fleeing from measurement misclassification since no personal measurement was taken. However, we can expect that a measurement bias be reduced in a district-specific estimate since a monitoring station is hefter representative cf air quality of the matched district. The similar results to those from the previous studios indicated existence of health effect of air pollution at current levels in many industrialized countries, including Korea.

  • PDF

Comparison of Cleaning Performance of CFC 113 and the Alternatives (CFC 113과 대체세정제의 세정성능 비교)

  • Row, Kyung Ho;Choi, Dai-Ki;Lee, Youn Yong
    • Analytical Science and Technology
    • /
    • v.6 no.5
    • /
    • pp.521-530
    • /
    • 1993
  • According to the Montreal Protocol, CFC 113, one of the ozone-depleting substances, will be prohibited to use as a cleaning solvent essentially in the electronic industry. Therefore, the development of the alternative cleaning solvents to CFC 113 is being accelerated. A number of the alternative cleaning solvents are avialable on the market. The alternatives of Axarel 32(DuPont), Cleanthru 750H(KAO Chemical), and EC-Ultra(Petroferm) are chosen for the comparison of cleaning performance with CFC 113. The test methods for measuring the cleaning performance were composed of the measurement of the physical properties, the experiments on the material compatibility with cleaning solvents, the measurement of the evaporation rate, and finally the experiments of the removal efficiency. Normally the basic physical properties of the alternatives had higher boiling points, viscosity and surface tension, which were quite different to those of CFC 113. In terms of solubility of rosin-based flux, the solubilities of abietic acid (nonpolar organic) were similar, but those of the activator (polar organic) in the alternatives were better than CFC 113. The evaporation of the alternatives was very slow, compared to CFC 113, which had much lower boiling point. All the cleaning solvents showed the good material compatibility with FR4 and Cu-coated PCB. The better removal efficiencies of abietic acid were obtained when using the ultrasonic mechanical energy over the dipping method. The experiments also indicated the very slow-eavaporating solvent was not desirable with the dipping cleaning method, and the differences in the removal efficiency of the alternatives with the ultrasonic cleaning method were negligible. Among the alternatives, the overall cleaning performances were obsorved as almost similar. Before selecting the ultimate cleaning solvent, the application of cleaning machine, environmental issues, and economics are simultaneously considered with the cleaning performance.

  • PDF

Decomposition of odor using atmospheric-pressure plasma (플라즈마를 이용한 악취물질 분해 특성)

  • Kang, Seok-Won;Lee, Jae-Sik;Lee, Kang-San;Lim, Hee-Ah;Kim, Ji-Seong;Lee, Jeong-Dae;Park, Wol-Su;Park, Young-Koo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.708-718
    • /
    • 2020
  • Offensive odor is recognized as a social environmental problem due to its olfactory effects. Ammonia(NH3), hydrogen sulfide(H2S) and benzene(C6H6) are produced from various petrochemical plants, public sewage treatment plants, public livestock wastes, and food waste disposal facilities in large quantities. Therefore efficient decomposition of offensive odor is needed. In this study, the removal efficiency of atmospheric-pressure plasma operating at an ambient condition was investigated by evaluating the concentrations at upflow and downflow between the plasma reactor. The decomposition of offensive odor using plasma is based on the mechanism of photochemical oxidation of offensive odor using free radical and ozone(O3) generated when discharging plasma, which enables the decomposition of offensive odor at ordinary temperature and has the advantage of no secondary pollutants. As a result, all three odor substances were completely decontaminated within 1 minute as soon as discharging the plasma up to 500 W. This result confirms that high concentration odors or mixed odor materials can be reduced using atmospheric-pressure plasma.