A Study of the Improvement in an Anaerobic Digester for Sludge Reduction (슬러지 저감을 위한 혐기성 소화조 개선에 관한 연구)

  • Kim, Hong-Seok;Lee, Tae-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.516-522
    • /
    • 2011
  • The largest problem of domestic anaerobic digestion is low digestion efficiency. Reasons of the problem would be low organic matters input, low mixing efficiency in digestion tank, refractory excess sludge etc.. In this study, screw attached disk-type concentration system and a mechanical mixing system, solubilization facility improvements were performed to solve problems. Through these improvements, the sludge conc. of the concentrator increased 2.6-fold and the volume reduction efficiency was increased 3.0-fold. In addition, the dead-space is reduced by mechanical agitation. Anaerobic digester gas production in the digestion tank is increased from $193.8m^3$ to $386.0m^3$ per day. Digestion efficiency is improved to 54.6% from 47.6%. Digestion gas production is increased from $0.30Nm^3/kg$ VS to $0.42Nm^3/kg$ VS.

A Study on Installation of Removal Device for Volatile Organic Compounds from Petrochemical Plant (석유화학 공장에서 VOCs 제거시설 설치사례 연구)

  • 김석택
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.95-101
    • /
    • 2000
  • High growth of economy and industrial development was produced every air pollutants, that is, SOx, NOx, dust, VOCs and malodorous gas was produced. Recently, volatile organic compounds(VOCs) was bring about very serious environmental problems. Ulsan petrochemical complex was densely a large scale of petrochemical plant. This study was carried out to select treatment equipment of VOCs produced from petrochemical plant, and has compared with Carbon filter, Regenerative thermal oxidation(RCO) and Flare stack for technical merit and demerit but also initial investment and operating cost.

  • PDF

Removal of Residual Antibiotics-Ciprofloxacin, Trimethoprim and Enrofloxacin-from Water by Ozone Oxidation (수중 미량 잔류항생물질 Ciprofloxacin, Trimethoprim, Enrofloxacin의 오존산화제거)

  • Han, Min-Su;Choi, Yeon-Woo;Song, Jun-Hyuck;Wang, Chang-Keun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.149-156
    • /
    • 2018
  • Oxidation of Ciprofloxacin, Trimethoprim, and Enrofloxacin by ozone was experimentally investigated to observe the effects of background water quality (such as ultrapure water, humic acid, and biologically treated wastewater) and water temperature on the removal rate of these antibiotics, and, thereby, to be able to provide design information when the ozone treatment process is adopted. Initial concentrations of the antibiotics spiked to $10{\mu}g/L$, and the ozone dose was 1, 2, 3, 5, and 8 mg/L. While the removal rate of Ciprofloxacin under ultrapure water background by ozone oxidation was over 99%, the removal rate under humic acid and biologically treated wastewater background was markedly lower, in the range of 49.3% ~ 99% and 19.8 % ~ 99 %, respectively. When water temperature is decreased from $20^{\circ}C$ to $4^{\circ}C$, the removal rate is reduced from the range of 19.8% ~ 99 % to the range of 7.5 % ~ 99 % under a biologically treated wastewater background. The effects of background and temperature on the removal rate of Trimethoprim and Enrofloxacin were similar to that of Ciprofloxacin, but the degree was different. Therefore, it is concluded that the background of water to be treated, as well as water temperature, should be taken into consideration when the design factor, such as ozone dose, is determined, so that the treatment objective of the ozone treatment process can be most effectively met.

VOCs Removal in Drinking Water Treatment Process by Ozonation (오존산화에 의한 수처리공정에서 VOCs의 제거 특성)

  • Han, Myung-Ho;Choi, Joon-Ho;Lim, Hak-Sang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.65-75
    • /
    • 1997
  • Removal characteristics of volatile organic carbons(VOCs) by ozone oxidation and other processes in the raw water of the 1st Nakdong water treatment plant were investigated. Dichrolomethane, toluene and other 7 compounds were detected in the raw water. With regard to detected 4 compounds in finally treated water, it was found that VOCs could not be removed effectively by traditional water treatment process. Benzene, 1,2-dichlorobenzne were not detected in the raw water but they were detected in the process of treatment. The compound of highest detection frequency was dichloromethane. When the raw water was controlled at pH 7, temperature $20^{\circ}C$, 5 minutes as contact time, 10 minutes as reaction time, the removal rate of THMFP, $KMnO_4$ demand, TOC, $UV_{254nm}$ and $NH_3-N$ were 46.4%, 22%, 19.6%, 31% and 8%, respectively. From estimating the finally treated water qualities in 7 kinds of treatment processes, P-6 process(raw water-chlorination-coagulation-ozonation) was most effective for organics removal and THMs control. Removal efficiencies for $KMnO_4$ demand and TOC by the process which combined preozonation with coagulation was twice better than only preozonation. $NH_3-N$ removal rate was shown as 10% by P-3 process(raw water-coagulation-ozonation), but 83% of $NH_3-N$ was removed by P-4 process(raw water-coagulation-chlorination). It was found that the chlorination is more effective than the ozonation for the NH3-N removal as commonly known.

  • PDF

A Study on Removal of NOx by Low Temperature Plasma (저온플라즈마에 의한 질소산화물의 제거에 관한 연구)

  • Park, Hei-Jae;Lee, Nae-Woo;Choi, Jae-Wook;Lim, Woo-Sub
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.540-543
    • /
    • 2010
  • In this study, we made low temperature plasma reactor in order to treat safely $NO_x$ which included in the gas. We investigated experimently and inspected efficiency characteristics of equipment about flow rate of reactant material and discharge input power which supplied into reactor. As a reaction gas, by using mixture gas of $NO/N_2$ and $N_2/O_2$, we setted up initial NO concentration and supplied the speed of a current to 1~4 l/min. When the amount of flow increased, reduction rate of NO was low. Also when discharge input power was high, decomposition of NO was easy. Also the longer delay time of reaction material and the higher discharge input power was, the higher decomposition energy efficiency was. And when the amount of flow was much, and the more discharge input power increased, the more ozone generated.

Study on the Removal of Fluorescent Whitening Agent for Paper-mill Wastewater Reuse using the Submerged Membrane Bioreactor(SMBR) with Ozone Oxidation Process (제지폐수 재이용을 위한 침지형 생물막 여과와 오존산화공정(SMBR-Ozone Oxidation Process)에 의한 형광증백제 제거에 관한 연구)

  • Choi, Jang-Seung;Shin, Dong-Hun;Ryu, Seung-Han;Lee, Jae-Hun;Ryu, Jae-Young;Shin, Won-Sik;Lee, Seul-Ki;Park, Min-Soo;Lee, Sang Oh
    • Textile Coloration and Finishing
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2018
  • In this study, effluent water was produced through Submerged Membrane Bio-Reactor(SMBR) process, which is a simple system and decomposes organic matter contained in wastewater with biological treatment process and performs solid-liquid separation, Especially, ozone oxidation treatment process is applied to effluent water containing fluorescent whitening agent, which is a trace pollutant which is not removed by biological treatment, and influences the quality of reused water. The concentration of $COD_{Cr}$ in the SMBR was $449.3mg/{\ell}-COD_{Cr}$, and the concentration of permeate water was $100.3mg/{\ell}-COD_{Cr}$. The removal efficiency was about 70.1%. The amount of ozone required for the removal of the fluorescent whitening agent in the permeated water in SMBR was $6.67g-O_3/min$, and the amount of ozone required to remove $COD_{Mn}$ relative to the permeate water was calculated to remove $0.997mg-COD_{Mn}$ for 1mg of $O_3$.

Removal of Non-volatile Contaminant from Aquifer using Surfactant-enhanced Ozone Sparging (오존과 계면활성제를 이용한 대수층 내 비휘발성 물질 제거)

  • Yang, Su-Kyeong;Shin, Seung-Yeop;Kim, Heon-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.6
    • /
    • pp.37-45
    • /
    • 2010
  • Surfactant-enhanced ozone sparging (SEOS), an advanced version of SEAS (surfactant-enhance air sparging) was introduced in this study for the first time for removal of non-volatile contaminant from aquifer. The advantages of implementing SEAS, enhanced air saturation and expanded zone of sparging influence, are combined with the oxidative potential of ozone gas. Experiments conducted in this study were tow fold; 1-dimensional column experiments for the changes in the gas saturation and contaminant removal during sparging, and 2-dimensional box model experiment for the changes in the size of zone of influence and contaminant removal. An anionic surfactant (SDBS, sodium dodecylbenzene sulfonate) was used to control surface tension of water. Fluorescein sodium salt was used as a representative of watersoluble contaminants, for its fluorescence which is easy to detect when it disappears due to oxidative degradation. Three different gases (air, high-concentration ozone gas, and low-concentration ozone gas) were used for the sparging of 1-D column experiment, while two gases (air and low-concentration ozone gas) were used for 2-D box model experiment. When SEOS was performed for the column and box model, the air saturation and the zone of influence were improved significantly compared to air sparging without surface tension suppression, resulted in effective removal of the contaminant. Based on the experiments observations conducted in this study, SEOS was found to maintain the advantages of SEAS with further capability of oxidative degradation of non-volatile contaminants.

Removal of Sulfamethoxazole using Ozonation or UV Radiation; Kinetic Study and Effect of pH (오존 처리 및 UV 조사를 이용한 Sulfamethoxazole 제거; 동역학적 고찰 및 pH 영향)

  • Jung, Yeonjung;Kim, Wangi;Jang, Hayoung;Choi, Yanghwun;Oh, Byungsoo;Kang, Joonwun
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This study was performed to assess the potential use of ozone or UV radiation for the treatment of water contaminated with sulfamethoxazole (SMX), which is frequently used antibiotic in human and veterinary medicines, especially focusing on the kinetic study and effect of pH. In a study using ozone alone, kinetic study was performed to determine second-order rate constant ($k_{O3,SMX}$) for the reactions of SMX with ozone, which was found to be $1.9{\times}10^6M^{-1}s^{-1}$ at pH 7. The removal efficiencies of SMX by ozone were decreased with increase of pH due to rapid decomposition of ozone under the condition of various pH (2.5, 5.3, 7, 8, 10). In a UV irradiation study at 254 nm, a kinetic model for direct photolysis of SMX was developed with determination of quantum yield ($0.08mol\;Einstein^{-1}$) and molar extinction coefficient ($15,872M^{-1}cm^{-1}$) values under the condition of quantum shielding due to the presence of reaction by-products formed during photolysis. For effect of pH on photolysis of SMX, SMX in the anionic state ($S^-$, pH > 5.6), most prevalent form at environmentally relevant pH values, degraded more slowly than in the neutral state (SH, 1.85 < pH < 5.6) by UV radiation at 254 nm.

A Study on the Characteristics of Hybrid-Plasma Torch for Dyeing Wastewater Treatment (염색폐수 처리를 위한 하이브리드 플라즈마 특성연구)

  • Jung, Jang-Gun;Youn, Seok-Hyun;Park, Jae-Youn;Kim, Sang-Don
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.75-81
    • /
    • 2008
  • Water treatment study employing plasma is thoroughly examined in the following paper. The research using water plasma torch showed superior results in terms of economical and energy efficiency due to the substantial reduction of electric power. A comparison of streamer and arc discharge phenomena taken place in water was put under close scrutiny. Dyeing wastewater exposed to the plasma treatment was sampled and analyzed for relative dissolved ozone concentration, hydrogen peroxide, as well as the color removal efficiency. It was found that streamer discharges is more effective than arc discharge in growth of $H_2O_2$ and $O_3$ by plasma chemical constituents, though plasma torch had small oxidation reagents selectivity. Thus, streamer discharges, due to the efficient plasma-chemical reactions environment, proved to be more efficient compare to the thermal arc plasma loading.

Characteristics of The Wastewater Treatment Processes for The Removal of Dyes in Aqueous Solution(2) - Ozonation or ACF Adsorption Treatment of Reactive Dyes - (수용액 중의 염료 제거를 위한 폐수처리공정의 특성(2) - 반응성염료의 오존산화 및 섬유상활성탄 흡착 처리 -)

  • Han, Myung-Ho;Huh, Man-Woo
    • Textile Coloration and Finishing
    • /
    • v.19 no.3
    • /
    • pp.26-36
    • /
    • 2007
  • This study was carried out to treat the aqueous solutions containing reactive dyes(RB19, RR120 and RY179) by the Ozone demand flask method and adsorption process using activated carbon fiber(ACF) which are one of the main pollutants in dye wastewater. Ozone oxidation of three kinds of the reactive dyes was examined to investigate the reactivity of dyes with ozone, competition reaction and ozone utilization on various conditions for single- and multi-solute dye solution. Concentration of dyes was decreased continuously with increasing ozone dosage in the single-solute dye solutions. Competition quotient values were calculated to investigate the preferential oxidation of individual dyes in multi-solute dye solutions. Competition quotients(CQi) and values of the overall utilization efficiency, ${\eta}O_3$, were increased at 40mg/l of ozone dosage in multi-solute dye solutions. ACF(A-15) has much larger specific surface area$(1,584m^2/g-ACF)$ in comparison with granular activated carbon adsorbent (F400, $1,125m^2/g-GAC$), which is commonly used, and most of pores were found to be micropores with pore radius of 2nm and below. It was found that RB19 was most easily adsorbed among the dyes in this study. In the case of PCP (p-chlorophenol) and sucrose, which are single component adsorbate, adsorption capacities of ACF(A-15) were in good agreement with the batch adsorption measurement, and saturation time predicted of ACF columns for these components was also well agreed with practically measured time. But in the case of reactive dyes, which have relatively high molecular weight and aggregated with multi-components, adsorption capacities or saturation time predicted were not agreed with practically measured values.