• Title/Summary/Keyword: 오일 오염도

Search Result 497, Processing Time 0.028 seconds

Determination of fatty acid methyl esters (FAME) content in aviation turbine fuel using multi-dimensional GC-MS (Multi-dimensional GC-MS를 이용한 항공터빈유의 FAME 함량 분석)

  • Youn, Ju Min;Doh, Jin Woo;Hwang, In Ha;Kim, Seong Lyong;Kang, Yong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.717-726
    • /
    • 2017
  • The current allowable cross-contamination level of fatty acid methyl esters (FAME) in aviation turbine fuel (AVTUR) is 50 mg/kg, due to that the presence of FAME in AVTUR can significantly impact the fuel supply system and jet engine. It has been difficult to analyze the level of FAME in AVTUR, since it is consisted of a lot of hydrocarbons. In this study, thus, a new method using multi-dimensional GC-MS (MDGC-MS) was proposed in order to determine the FAME level in AVTUR effectively. Applying to MDGC-MS with Deans switching system enabled us to detect and quantify the FAME with low carbon numbers such as those derived from coconut oil and palm kernel oil. The matrix effect of MDGC-MS method, which could shift the FAME peaks to slightly longer retention times, was reduced by 20 times compared with that of 1-dimensional GC-MS reference method. This developed method could be suitable for qualitative and quantitative analyses to determine the contamination level of trace FAME in AVTUR.

Model Predictive Control for Distributed Storage Facilities and Sewer Network Systems via PSO (분산형 저류시설-하수관망 네트워크 시스템의 입자군집최적화 기반 모델 예측 제어)

  • Baek, Hyunwook;Ryu, Jaena;Kim, Tea-Hyoung;Oh, Jeill
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.722-728
    • /
    • 2012
  • Urban sewer systems has a limitation of capacity of rainwater storage and problem of occurrence of untreated sewage, so adopting a storage facility for sewer flooding prevention and urban non-point pollution reduction has a big attention. The Korea Ministry of Environment has recently introduced a new concept of "multi-functional storage facility", which is crucial not only in preventive stormwater management but also in dealing with combined sewer overflow and sanitary sewer discharge, and also has been promoting its adoption. However, reserving a space for a single large-scale storage facility might be difficult especially in urban areas. Thus, decentralized construction of small- and midium-sized storage facilities and its operation have been introduced as an alternative way. In this paper, we propose a model predictive control scheme for an optimized operation of distributed storage facilities and sewer networks. To this aim, we first describe the mathematical model of each component of networks system which enables us to analyze its detailed dynamic behavior. Second, overflow locations and volumes will be predicted based on the developed network model with data on the external inflow occurred at specific locations of the network. MPC scheme based on the introduced particle swarm optimization technique then produces the optimized the gate setting for sewer network flow control, which minimizes sewer flooding and maximizes the potential storage capacity. Finally, the operational efficacy of the proposed control scheme is demonstrated by simulation study with virtual rainstorm event.

The Characteristics of Groundwater and a Field Test for Thermal Insulation of Landfarming of Petroleum Contaminated Soil in Winter Season (유류오염지역의 지하수 수질특성 및 동절기 토양경작법의 온도보전을 위한 현장사례 연구)

  • Cho, Chang-Hwan;Kim, Soon-Heum;An, Jong-Ik;Lee, Yoon-Oh;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.5
    • /
    • pp.7-14
    • /
    • 2013
  • The objectives of this study were to identify the characteristics of groundwater in the petroleum contaminated site and to evaluate the applicability of house-type landfarm facilities heated with briquette stoves in winter season. The six monitoring wells were installed at the site where pH, dissolved oxygen, and temperature were all measured. Also groundwater contaminants, benzene, toluene, ethylbenzene, xylene and total petroleum hydrocarbon, were analyzed twice. House-type two landfarm facilities ($12m{\times}40m{\times}4.8m$) each installed with four briquette stoves were constructed. During four rounds treatment process, VOCs, moisture, temperature were monitored and soil contaminants were analyzed. The pH was 6.37 and considered subacid and DO was measured to be 3.12 mg/L. The temperature of groundwater was measured to be $9.48^{\circ}C$. The groundwater contaminants were detected only in the monitoring wells within the contaminated area or close to it showing that the groundwater contaminated area was similar to the soil contaminated area. During the landfarm process, 73.3% of VOCs concentration in interior gas was decreased and moisture was lowered from 17.7% to 13.4%. In the morning, at 8:00 am, the temperature was decreased showing soil ($5.5^{\circ}C$) > interior ($4.8^{\circ}C$) > exterior ($3.5^{\circ}C$). In the afternoon, at 2:00 pm, the temperature was soil ($8.6^{\circ}C$) < interior ($9.9^{\circ}C$) < exterior ($11.5^{\circ}C$) with solar radiation. The temperature difference between interior and exterior was $0.7^{\circ}C$ in the morning, but it was $1.6^{\circ}C$ in the afternoon. A total of 130 days were taken for four round landfarm processes. Each process was completed within 33 days showing 80% of cleanup efficiency ($1^{st}$ order dissipation rate(k) = 0.1771).

A numerical analysis study on the flammable volume by leakage of hydrogen fuel vehicles in parking lot (지하주차장 내 수소연료차의 수소 방출시 가연체적에 관한 수치해석적 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Kim, Doo-Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.439-449
    • /
    • 2021
  • The recent reduction in greenhouse gases, interest in environmental pollution such as low-carbon emission policies is increasing. Accordingly, the penetration rate of eco-friendly vehicles, including hydrogen battery vehicles capable of reducing carbon emission, is increasing, and thus it is required for disaster prevention and safety-related measures. In this study, the degree of risk for the concentration distribution of hydrogen when leaking hydrogen fuel vehicles according to ventilation conditions was analyzed through numerical analysis, limited to places in parking lots. As a result, when only one hydrogen tank was released, the combustible volume ratio of hydrogen in the underground parking lot was up to 8.6%, and as ventilation continued, the volume ratio of combustible hydrogen decreased to less than 1% after 150 seconds, indicating that mechanical ventilation is essential. In the case of simultaneous release or stage release of three hydrogen tanks, the final combustible volume ratio of hydrogen is similar, but the increase in the combustible volume ratio of hydrogen in the early stage of release is low, and further research is expected.

Study on Characteristics of Change of Physical/Chemical property of Refined Fuel Oil(Reduced-pressure) by Mixing with By-product Fuel Oil(No. 2) (부생연료유(2호) 혼합에 따른 정제연료유(감압)의 물성 변화 특성 연구)

  • Doe, Jin-woo;Lim, Tae-yun;Yim, Eui-soon;Lee, Joung-min;Kang, Hyung-kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1349-1358
    • /
    • 2018
  • In addition to responding to the environmental pollution caused by fossil fuels, the enforcement of Renewable Fuel Standard(RFS) system has increased the utilization of renewable energy such as refined fuels oil. The by-product fuel oil(No. 2) and the refined fuel oil(reduced-pressure) are strictly regulated by the domestic legislation and the chemical property changes of the refined fuel oil(reduced-pressure) mixed with the by-product fuel oil(No. 2) were analyzed. As a result of analyzing the physical properties of refined fuel oil(reduced pressure) obtained by mixing 1 : 1 of by-product fuel oil(No. 2), it satisfied the quality standards stipulated by the domestic Enforcement Decree of the Wastes Control Act. However, the results of the additional tests related to the fuel showed a high aromatic content. The high content of aromatic in a fuel is likely to cause the soot and ehaust emission gas during the combustion of the used equipment.

Selection of Entomopathogenic Fungus Isaria javanica FT333 for Dual Control of Thrips and Anthracnose (총채벌레 및 고추탄저병의 동시 방제를 위한 곤충병원성 곰팡이 Isaria javanica FT333 선발)

  • Lee, Moran;Jeong, Hyeju;Kim, Jaeyoon;Kim, Dayeon;Ahn, Seung Ho;Lee, SangYeob;Han, Ji Hee
    • The Korean Journal of Mycology
    • /
    • v.46 no.4
    • /
    • pp.479-490
    • /
    • 2018
  • Red pepper is seriously damaged by thrips (Thrips palmi) and anthracnose caused by Colletotrichum acutatum throughout its development. Because of biotic constraints, producers often depend on chemicals that are expensive and have adverse effects on the environment, operator, and beneficial insects. In addition, resistance is developed because of the repeated use of chemicals. In recent decades, the use of microorganisms in crop protection has become a credible alternative because it is eco-friendly. In this study, we aimed to select isolates with insecticidal and fungicidal activities against the pathogens that cause anthracnose and thrips. We treated T. palmi adults and juveniles with 13 strains of entomopathogenic fungi (isolated from the soil by using the insect-bait method), and 6 strains showed excellent insecticidal activity (70-100%) 5 days after the treatment. The selected isolates were cultured with C. acutatum to screen for the strain with excellent anti-fungal activities, among which an isolate FT333 showed more than 95% control efficacy against C. acutatum in vitro. The isolate was identified as Isaria javanica through its morphological characteristics and phylogenetic analysis of the ITS and ${\beta}-tubulin$ nucleotide sequences. The Isaria javanica FT333 isolate could be used effectively for dual bio-control of thrips and anthracnose during red pepper cultivation.

Reconsideration and Conservational Scientific Diagnosis of Silla Stone Monument in Bongpyeong-ri, Uljin (울진 봉평리 신라비의 재판독과 보존과학적 진단)

  • Jo, Young-hoon;Lee, Chan-hee;Shim, Hyun-yong
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.3
    • /
    • pp.48-67
    • /
    • 2013
  • This study was focused on the recognition of historical values and the establishment of conservation schemes for a Silla stone monument in Bongpyeong-ri, Uljin by combining the humanistic investigation of inscription reinterpretation and the scientific conservational diagnosis of deterioration. According to the investigation of inscription, a total of 13 letters were reconsidered compared to the preceding researches. Thus, the meaning and interpretation of previous inscription was partially changed. This monument is composed of gneissose leucogranite and the most suitable site as provenance of the stone would be the Jukbyeon seashore (2.1km). The site shows similar color, size and composition of minerals, gneissose structure and magnetic susceptibility as the Bongpyeong stone monument. This monument developed a structural crack (crack index 0.4) and a microcrack (crack index 2.0) along the gneissose structure. The horizontal strength is weaker than the vertical strength. Therefore, the cracks should be reinforced and treated. However, consolidating is not urgently needed because the total weathering grade by ultrasonic velocity shows the stage of moderate weathering(3,403m/s, 0.32). Also, the major problems of chemical deterioration are blackening (85.2%) with soil, iron oxide,rubbing mark, and salt crystals (17.3%) from the sea. Therefore, the contaminants and the salt crystals should be removed using pressure spray and pulp paper, while the application of poultice should be examined through clinical tests.

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

Characteristics of Macro Benthic Community in the Subtidal Zone of Muan Bay on Summer and Health Assessment by using AZTI Marine Biotic Index (AMBI) and Water Quality Index (WQI) (하계 무안만 조하대 저서동물군집 특성 및 AZTI의 해양생물지수(AMBI)와 수질평가지수(WQI)를 이용한 건강성 평가)

  • Oh, Jun Ho;Lee, Kyoung Seon
    • Journal of Marine Life Science
    • /
    • v.7 no.1
    • /
    • pp.21-28
    • /
    • 2022
  • Benthic animals are important indicators in benthic environmental quality assessment. This study investigated the environmental characteristics and the distribution pattern of benthic animals, and assessed the benthic ecosystem using AMBI (AZTI's marine biotic index) and WQI (water quality index) in the subtidal zone of Muan bay. Samplings were collected from 10 stations in the subtidal zone of Muan bay on summer. In the upper area of Muan bay, grain size was finer and organic content was higher than those of in the lower area. The pollution indicator organism such as Musculista senhousia, Theora fragilis and Lumbrineris longifolia were dominant at some stations. The benthic community was distinguished into three groups of upper, center and lower area of Muan bay, and which were coincided with the results by correlation analysis between organic matter content and benthic health assessment (WQI and AMBI). As a result of this study, the health condition of the subtidal zone in Muan bay were good. However, from the results that benthic animals were not evenly distributed, and also the opportunistic species appeared, the load of organic matter in Muan bay seems to be increasing.

Concentrations of the Pollutants in Ground Water and their Behavior in Soils in Cheju Island;II. Nitrate-nitrogen concentration and tis relation to other ions in ground water near the district of pig arming complex in the northwest region (제주도 지하수중 오염물질의 농도와 토양중 그의 행동에 관한 연구;Ⅱ. 서북부지역 양돈단지 주변 지하수중의 $NO_3-N$ 농도와 다른 이온과의 관계)

  • Hyun, Hae-Nam;Koh, Seung-Hak;Oh, Sang-Sil
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.2
    • /
    • pp.151-159
    • /
    • 1994
  • This study was conducted to investigate the $NO_3-N$ concentration, the relationship between $NO_3-N$ and other ions, and patterns of ions in ground water used as drinking water in Cheju Island. Samples were collected from 19 wells in the northwest region, near the district of poultry complex, and 9 wells in the northeast region. In the northwest region, $NO_3-N$ concentrations in D-14 and D-202 wells near the pig farming facilities were 10.95 and 13.1 mg/L, respectively, exceeding the standard concentration of drinking water. The concentration in D-65, D-35, and D-120 wells were slightly lower than the standard concentration. However, $NO_3-N$ concentrations in the wells in the northeast region were lower than 3mg/L. In wells in the northwest region, $NO_3-N$ concentrations were negatively correlated with pH and positively correlated with $Ca^{++}$, $Mg^{++}$, $Na^+$ $Cl^-$, $SO_4^{--}$, and $Cl^-/HCO_3^-$. However, in the northeast region, they were not related with pH and the ions. The chemical compositions in D-65, D-35, and D-41 wells showed higher concentrations of $Ca^{++}$, $Mg^{++}$, $Na^+$, $Cl^-$, $NO_3-N$ and $SO_4^{--}$ than the unpolluted D-42 well. These results suggest that ground water near the pig farming complex was polluted by pig farming waste in the northwest region.

  • PDF