• Title/Summary/Keyword: 오일 공급 시스템

Search Result 91, Processing Time 0.031 seconds

Analysis of Determinant Factors of Apartment Price Considering the Spatial Distribution and Housing Attributes (공간지리적 요인과 주거특성을 고려한 공동주택 가격결정 분석)

  • Moon, Tae-Heon;Jeong, Yoon-Young
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.1
    • /
    • pp.68-79
    • /
    • 2008
  • Because local cities are different from large cities, they need to reflect their own characteristics of housing market. Thus in order to obtain useful implications for the establishing sound housing market in Jinju City, this paper investigated the characteristics of spatial distribution and determinant factors that affect apartment price in Jinju City. GIS representation of the apartments showed that most of old and small apartments were built in 'land readjustment project' areas executed in 1970s. On the contrary, new and large scale apartment complexes were built quite recently and distributed in the western and southern parts of the city. Next, in order to examine the factors which affect apartment price, this paper subtracted firstly several variables from the related studies. However in order to avoid multi-colinearity, variables were summarized by means of factor analysis. Then, setting apartment price as a dependant variable, 12 hedonic price models were established with 33 independent variables. As results, building age, floor area, accessibility to university and hospital, accessibility to arterial road, and stair-type building were turned out to be significant. These results will be used in making the supply and allocation plan of urban facilities and housing. Finally as conclusions this paper emphasized the need of periodic analysis of local housing market and establishing detailed housing information systems.

  • PDF

Modeling of thermal fluidized desorption for diesel-oil contaminated soils (Diesel-oil에 오염된 토양의 유동상 열탈착 모델링)

  • 이상화;김병욱;이상득;박달근;이중기
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.137-147
    • /
    • 1999
  • Fluidized-bed thermal desorber coupled with a heat pipe was investigated for the remediation of soil contaminated with diesel oils. Thermal gravimetric analysis by Cahn-balance indicated that the desorption of diesel oils from the soil particles was mainly governed by the internal diffusion at low concentration of less than 0.5 wt. % of oils in the soil particles. In fluidized-bed experiments. increase of fluidizing gas velocity reduced the residual oils of the contaminated soils, the increase of soil feed rate decreased efficiency of fluidized-bed desorber. A mathematical model was developed by incorporating Fickian diffusion kinetics into the Kunii-Levenspiel model Simulation results showed reasonable agreement for the performance of fluidized-bed thermal desorber.

  • PDF

Determination of fatty acid methyl esters (FAME) content in aviation turbine fuel using multi-dimensional GC-MS (Multi-dimensional GC-MS를 이용한 항공터빈유의 FAME 함량 분석)

  • Youn, Ju Min;Doh, Jin Woo;Hwang, In Ha;Kim, Seong Lyong;Kang, Yong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.717-726
    • /
    • 2017
  • The current allowable cross-contamination level of fatty acid methyl esters (FAME) in aviation turbine fuel (AVTUR) is 50 mg/kg, due to that the presence of FAME in AVTUR can significantly impact the fuel supply system and jet engine. It has been difficult to analyze the level of FAME in AVTUR, since it is consisted of a lot of hydrocarbons. In this study, thus, a new method using multi-dimensional GC-MS (MDGC-MS) was proposed in order to determine the FAME level in AVTUR effectively. Applying to MDGC-MS with Deans switching system enabled us to detect and quantify the FAME with low carbon numbers such as those derived from coconut oil and palm kernel oil. The matrix effect of MDGC-MS method, which could shift the FAME peaks to slightly longer retention times, was reduced by 20 times compared with that of 1-dimensional GC-MS reference method. This developed method could be suitable for qualitative and quantitative analyses to determine the contamination level of trace FAME in AVTUR.

The Development of Container-type Plant Factory and Growth of Leafy Vegetables as Affected by Different Light Sources (컨테이너 식물공장의 개발과 이를 활용한 광원별 엽채류의 생장특성)

  • Um, Yeong-Cheol;Oh, Sang-Seok;Lee, Jun-Gu;Kim, Seung-Yu;Jang, Yoon-Ah
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.333-342
    • /
    • 2010
  • For the energy-saving production of fresh vegetables in poor environment such as the Antarctic, a container-type plant factory was designed and developed. To maximize space usage of the 20 feet container ($L5.9m{\times}W2.4m{\times}H2.4m$), a three-level hydroponic cultivation system was installed and the nutrient solution was supplied by bottom watering. Using this system, 3 lettuce cultivars were grown under different the light source (light intensity). After 2 weeks from the transplanting, fluorescent lamp ($145\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) showed the best fresh weight of top part and leaf area. However, After 4 weeks, fluorescent lamp plus metal halide lamp ($150\;{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) led to the optimum growth of the each lettuce cultivar. The cultivar, 'Cheongchima', showed the best fresh weight of top part and leaf area, followed by 'Jeokchukmyeon' and 'Lollo rosa'. The chlorophyll concentrations (SPAD) showed no significant difference among the sources of lights. However, 'Cheongchima' showed relatively high chlorophyll concentration. With the above results, we found that the growth of lettuce is depend on light intensity and even at same intensity, the growth is different among the cultivars. Therefore, the selection of optimum cultivar should be considered in the plant factory system that has only weak light density.

Analysis and Application of Water Footprint to Improve Water Resource Management System - With a Focus on Seoul City - (서울시 물환경관리체계 개선을 위한 물발자국 도입 및 활용방안에 관한 연구 - 서울시 자치구 물환경관리 정책 및 제도, 관리체계 분석을 중심으로 -)

  • Chun, Dong Jun;Kim, Jin-Oh
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.3
    • /
    • pp.222-232
    • /
    • 2016
  • Water Footprint is utilized to analyze direct and indirect water consumption for sustainable water resource management. This study aims to understand potential applicability of water footprint concept by analyzing the status of water consumption and related water policies in Seoul. We analyzed a direct gray water footprint and the blue water footprint in Seoul affected by the social and economic characteristics of the consumers in the city. In particular, in order to analyze the blue water footprint represented by both surface and underground water for the provision and consumption of products, we calculated the actual water consumptions of surface and underground water for 25 districts in Seoul. Our analysis in consideration of population and households indicates that Jung-gu has the highest blue water footprint followed by Jongro-gu, Gangnam-gu, Yongsan-gu, and Seocho-gu. Gray water footprint was calculated by estimating the amount of water for purifying wastewater to meet the water quality standard (above BOD 3.5ppm) for each district. As a result, Jung-gu has the highest gray water footprint, followed by Jongro-gu, Gangnam-gu, Yongsan-gu, Seocho-gu, and Youngdeungpo-gu. Our study suggests the potential value of using water footprint concept to complement the current limitations of water use management focusing on water supply control. We expect that our analysis will provide an important basis for considering water use management which is economically and socially more resilient and sustainable.

Study of Failure Examples for Emission Gas Control System in Gasoline Engine (가솔린 엔진 배출가스 제어장치에 대한 고장사례 고찰)

  • Lee, Il Kwon;Lee, Jong Ho;Lee, Young Suk;Youm, Kwang Wook;han, Jae Oh;Lim, Ha young
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.37-42
    • /
    • 2016
  • The purpose of this paper is to study for the emission gas control of passenger car. The first example, the PCSV never open when operating condition, but it opened by causing malfunction because of trouble. As a result, the purge gas entered into surge tank, a mount of fuel was displayed with excessive supply on tester. Therefore, it certified the bad-condition of the engine when idling by decreasing of fuel injection quantity from engine ECU. The second example, the hose activating a EGR valve didn't supply the vacuum pressure because of assembling the other part. Thus, it knew the bad-condition of engine that the EGR valve would not work normally by leaking with the other port. The third example, as the rear oxygen sensor of two sensor were fault-installing by changing the sensor of other a car it could not detect of oxygen quantity. Finally, it found the phenomenon of abruptly decreasing vehicle speed when braking a car. Therefore, the system including with emission control has to drastically manage by maximizing condition to role decreasing the emission gas.

Experimental Investigation of Water Discharge Capability According to Shape of Sluice for Tidal Power Generation - I. Physical Experiment (조력발전용 수문 형상에 따른 통수성능에 관한 실험적 연구 - I. 수리모형실험)

  • Lee, Dal-Soo;Oh, Sang-Ho;Yi, Jin-Hak;Park, Woo-Sun;Cho, Hyu-Sang;Kim, Duk-Gu
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • An hydraulic experiment was carried out in an open channel flume in order to improve the technique of designing shape of the sluice used for tidal power generation, which greatly affects the economical efficiency of the construction of a tidal power plant. To predict the influence of change in the major design parameters relating to the sluice shape on the water discharge capability of the sluice, it was necessary to perform a precise experiment that is discriminated to previous feasibility studies or design projects. For this purpose, by installing various flow straighteners and rectifying structures inside the water supply system and the rectifying tank, the flow in the flume was stabilized as tranquil as possible. In addition, the measuring instruments and the location of installing them were carefully determined so as to minimize the errors intervened during the measurement of water discharge and water level. The method of estimating head difference between upstream and downstream of the sluice was also developed by taking account of the head loss due to the friction at the bottom and side walls in the flume.

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

A Study on Developing Web based Logistic Information System(KT-Logis) (웹 기반 통합물류정보시스템(KT-Logis) 개발에 관한 연구)

  • 오상호;김태준
    • Proceedings of the Korean DIstribution Association Conference
    • /
    • 2001.11b
    • /
    • pp.125-141
    • /
    • 2001
  • In this paper, the current problems of logistics industry in Korea and their possible solutions were discussed. With Korea Telecoms KT-Logis, the supplier and demander of logistics service would not have to invest large sum of money into their computer system. All they need is just a computer with internet connected. What KT-Logis influence on the logistics industry are the following; 1. Many logistics service supplier and demander can do the business on the web with one computer system. 2. This web based computer system does not only work on the office but also apply on the field worker such as delivery personnel or even the forwarder with mobile phone. 3. KT-Logis is an integrated system which cover the broad arrange of logistics management from truck management to customer relations management. 4. Finally, KT-Logis is web based systems which suits for current e-business and mobile environment. In future, more studies should be done to develop more progressive integrated logistics information systems with enterprise resource planning(ERP) and supply chain management(SCM).

  • PDF

Development of Optimal Nutrient Solution of Tomato(Lycopercicon esculentum Mill.) in a Closed Soilless Culture System (순환식 수경재배에 적합한 토마토 배양액 개발)

  • Yu, Sung-Oh;Bae, Jong-Hyang
    • Journal of Bio-Environment Control
    • /
    • v.14 no.3
    • /
    • pp.203-211
    • /
    • 2005
  • The experiment was conducted to investigate the nutrition absorption pattern in the growth stages and develope the optimal nutrient solution hydroponically grown the tomato in closed substrate culture system with the nutrient solution of National Horticultural Research Station in Japan into 1/2S, 1 S, and 2S. When plant was grown in 1/2 S, the growth and yield were high and the pH and EC in the rooting zone were stable. Suitable composition of nutrient solution for tomato was $NO_3-N$ 7.1, $PO_{4}$-P 2.1, K 4.0, Ca 3.1, Mg 1.2, and $SO_{4}-S\;1.2\;me{\cdot}L^{-1}$ in the early growth stage and $NO_3-N$ 6.5, $PO_4-P$ 2.3, K 3.4, Ca 3.1, Mg 1.1, and $SO_4-S\;1.1\;me{\cdot}L^{-1}$ in the late growth stage by calculating a rate of nutrient and water uptake. To estimate the suitability for the nutrient solution of tomato in a development of optimum nutrient solution of tomato developed by Wonkwang university in korea (WU), plant was grown in perlite substrate supplied with different solution and strengths(S) by research station for greenhouse vegetable and floricultuin in the Netherlands (Proefstation voor tuinbouw onder glas te Naaldwijk; PTG) of 1/2 S, 1 S and 2 S, respectively, The growth was good at the PTG and WU of 2 S in early growth stage, and at the WU 2S in late growth stage. The highest yield of tomato obtained in the WU of 2 S, although blossom-end rot was appeared in all treatments. pH and EC in root zone of WU of 2 S were stable during the early and late growth stage. Therefore when plant was grown in WU of 2 S, N and P content in the nutrient solution need to low, according N and P content of their leaves were high in WU of 2 S.