• Title/Summary/Keyword: 오일냉각기

Search Result 36, Processing Time 0.025 seconds

Characteristics of Temperature Control in the Inverter Type Oil Coolers (인버터 타입 오일냉각기의 온도제어 특성에 관한 연구)

  • 이상호;이찬홍;박천홍
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

Investigation of Stresses Due to Various Parameters of Shell and Tube Oil Cooler (다관 원통식 오일 냉각기의 다양한 파라미터에 따른 스트레스 고찰)

  • Han, S.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.5-12
    • /
    • 2009
  • The present work aims to estimate channel, shell, tube and tube sheet stresses of shell and tube oil cooler stemmed from various parameters. These parameters involve size, thickness and dimension of shell and tube oil cooler, including fluid temperature. The main purpose of the present work is to ensure safety of design products and also develop new products rapidly. For stress evaluation of oil coolers, first of all, the maximum pressure on the shell-side and on the tube side is fixed with 3.1MPa and 1.5MPa, respectively. Secondly, the pressure on each side varies from 2MPa to 3.1MPa on the shell side and tram 0.6MPa to 2MPa on the tube side. Various parameters under these conditions are employed to estimate design stresses on each side of oil cooler. These basic information related to stresses will be useful for a designer or manufacturer of an oil cooler.

  • PDF

The Optimum Selection and Drawing Output Program Development of Shell & Tube Type Oil Cooler (원통다관 형 오일냉각기의 최적선정 및 도면 출력 프로그램 개발)

  • Lee, Y.B.;Ko, J.M.;Kim, T.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2609-2614
    • /
    • 2007
  • Shell & Tube type Oil Cooler is widely used for hydraulic presses, die casting machines, generation equipments, machine tools and construction heavy machinery. Temperature of oil in the hydraulic system changes viscosity and thickness of oil film. They have a bad effect to performance and lubrication of hydraulic machinery, so it is important to know exactly the heat exchanging efficiency of oil cooler for controlling oil temperature. But most Korean manufacturers do not have test equipment for oil cooler, so they cannot carry out the efficiency test of oil cooler and it is impossible to verify its performance. This paper includes information of construction of necessary utilities for oil cooler test and design and manufacture of test equipment. One can select the optimum product by obtaining performance data through tests of various kinds of oil coolers. And also the paper developed a program which can be easily used for design of 2D and 3D drawings of oil cooler.

  • PDF

Numerical Study of the Effect of Fan Arrangement on the Cooling Performance of the ONAF Type Radiator for Power Transformer (변압기용 ONAF 방식 방열기의 팬 배치에 따른 냉각특성 연구)

  • Kim, Kuk-Kyeom;Suh, Yong Kweon;Kang, Sangmo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.449-455
    • /
    • 2015
  • Owing to the trend of an increase in capacity and high-efficiency requirement, the life and reliability of power transformer depend significantly on the amount of heat generation per unit volume and the degradation of insulation oil. These problems can be solved by enhancing the cooling performance of the radiator. The purpose of this study was to find a suitable position of fans for a better cooling effect given by the forced-convection of air in an ONAF (Oil Natural Air Forced) type transformer. In the simulation, commercial software was used for flow analysis, and the cooling passage of the oil was simplified to shorten the time taken for computation. With the diameter of the fan fixed at a constant value, the analysis was performed only by changing the position of the fans. As a result, a vertical position change of the fans does not affect the cooling performance significantly. However, the temperature drop given by the fans positioned on the front region of the transformer is larger than that on the rear region.

Study of Oil Jet Effect on the Temperature of Piston Head (피스톤 헤드 온도에 오일 제트가 미치는 영향에 대한 연구)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.536-540
    • /
    • 2018
  • As the performance of engines improves, the temperature of engines is increasing, resulting in a high piston temperature. An excessively high piston temperature may result in torque drop or engine failure. An oil jet is used to reduce the piston temperature. In this study, to monitor the effect of oil jet, a templug was used to measure the piston temperature. A templug is a kind of sensor and the hardness of the templug changes according to the piston temperature. Using a templug, the maximum temperature of the piston was measured with and without an oil jet. The piston temperature was lowered using the oil jet. The highest temperature region changed from the center crown to the front/rear area. In addition, the temperature difference between the highest and lowest regions became smaller.

Development of a purifying system to separate minute solid particles and water in oil (오일 속 미세입자 및 수분분리를 위한 청정기 시스템 개발)

  • Kim, Yong-Keun;Choi, Yoon-Hwan;Moon, Myung-Jun;Lee, Yeon-Won
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • In this research, a purifying system using a centrifugal filter equipped with a water separation component has been studied. Oil utilized for lubrication and cooling in marine engines becomes unable to achieve its original purpose over time as the accumulation of solid particles and water increases. Therefore, methods applying the Bernoulli equation to eliminate water in oil were investigated and proposed. As a result, a practical purifying system was designed and tested by an officially certified organization. The new purifying system is anticipated to contribute to the extension of the lifetime of oil in addition to damage reduction methods of mechanical parts.

Cooling System for Power Transformer Using Weighting Function (하중함수를 이용한 전력용 변압기 냉각 시스템)

  • Cho, Do-Hyeoun
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.40-45
    • /
    • 2012
  • In this paper, cooling system of power transformers is proposed for temperature optimized control. We predict the peak temperature of power transformer coils using load factors and construct a cooling system using weighting function. For the optimized temperature control for power transformer, a correlation function based on the load factor of a load current and the each temperatures for winding coils, for air and for oil is presented to predict the winding-coil peak temperature. Also, the results controlled by applying the power transformer is presented.

Mathematical Models of a Transformer Cooling System for the Control Algorithm Development (제어알고리즘 개발을 위한 변압기 냉각시스템의 수학적모델)

  • Han, Do-Young;Noh, Hee-Jeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.70-77
    • /
    • 2010
  • In order to improve the efficiency of a main transformer in a train, the optimal operation of a cooling system is necessary. For the development of optimal control algorithms of a cooling system, mathematical models of a main transformer cooling system were developed. These include static and dynamic models of a main transformer, an oil pump, an oil cooler, and a blower. Static models were used to find optimal oil temperatures of the inlet and the outlet of a transformer. Dynamic models were used to predict transient performances of control algorithms of a blower and an oil pump. Simulation results showed good predictions of the static and the dynamic behavior of a main transformer cooling system. Therefore, mathematical models developed in this study may be effectively used for the development of control algorithms of a main transformer cooling system.

Temperature Control for an Oil Cooler System Using PID Control with Fuzzy Logic (퍼지 적용 PID제어를 이용한 오일쿨러 시스템의 온도제어)

  • 김순철;홍대선;정원지
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.87-94
    • /
    • 2004
  • Recently, technical trend in machine tools is focused on enhancing of speed, accuracy and reliability. The high speed usually results in thermal displacement and structural deformation. To minimize the thermal effect, precision machine tools adopt a high precision cooling system. This study proposes a temperature control for an oil cooler system using Pill control with fuzzy logic. In the cooler system, refrigerant flow rate is controlled by rotational speed of a compressor, and outlet oil temperature is selected as the control variable. The fuzzy control rules iteratively correct PID parameters to minimize the error and difference between the outlet temperature and the reference temperature. Here, ambient temperature is used as the reference one. To show the effectiveness of the proposed method, a series of experiments are conducted for an oil cooler system of machine tools, and the results are compared with the ones of a conventional Pill control. The experimental results show that the proposed method has advantages of faster response and smaller overshoot.

A Study on the Grinding Characteristics According to Cooling Methods (대체냉각 기술을 이용한 환경친화 연삭가공 기술)

  • Lee, S.W.;Choi, H.Z.;Heo, N.H.;Lee, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.962-967
    • /
    • 2003
  • Recently, environmental pollution has become a serious problem in industry, and many researches have been done in order to preserve the environment. The coolant, which promotes lubrication, cooling and penetration, contains chlorine, sulfur and phosphorus to improve the machining efficiency. These additives, which move around into the air during machining, pollute working. Therefore, many researches on how to reduce the amount of coolant during machining have been carried out. However, to reduce even small amount of coolant causes high temperature of a workpiece and it brings thermal defects. In this study, the experiments of wet & dry grinding using cooling methods (using coolant only, mist and compressed cold air only) are performed to solve the problem of environmental contamination and to get a better surface integrity of a workpiece by comparing surface roughness, roundness and residual stress.

  • PDF