• Title/Summary/Keyword: 오염물질

Search Result 6,002, Processing Time 0.05 seconds

Plant uptake potential of endosulfan from soil by carrot and spinach (다소비 채소작물인 시금치와 당근의 토양 중 엔도설판 흡수이행능)

  • Choi, Geun-Hyoung;Jeong, Dong-Kyu;Lim, Sung-Jin;Ro, Jin-Ho;Ryu, Song-Hee;Park, Byung-Jun;Moon, Byung-Cheol;Kim, Jin Hyo
    • Journal of Applied Biological Chemistry
    • /
    • v.60 no.4
    • /
    • pp.339-342
    • /
    • 2017
  • Residual endosulfan in an agricultural environment has been reported, although endosulfan was listed to persistent organic pollutants and banned. To produce the safe crop from endosulfan residue risk, the plant uptake potential of endosulfan from soil to crop should be studied. In here, the plant uptake potentials of endosulfan in various crops were surveyed and ranged from 0.002-4.460. And the bioconcentration factors (BCF) of total endosulfan in carrot and spinach were calculated from the pot experiment. The BCFs in carrot and spinach were 0.285 and 0.040-0.047 respectively. Endosulfan sulfate was contributed to over 42.8% of the crop residue as a major contributor among the three endosulfan congeners in both of carrot and spinach.

Antioxidant Characteristics and Phytoremediation Potential of 27 Taxa of Roadside Trees at Industrial Complex Area (공단지역에서 생육하는 가로수 27종의 항산화특성과 잠재적 환경정화능력)

  • Han Sim-Hee;Lee Jae-Cheon;Oh Chang-Young;Kim Pan-Gi
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.3
    • /
    • pp.159-168
    • /
    • 2006
  • In order to screen for the best species for mitigating air pollutants by plants at an industrial complex area, we investigated antioxidant capacity, lipid peroxidation and nitrogen content in the leaves of 27 taxa of woody plants that are mostly utilized as roadside trees. Among 27 taxa, the highest value of antioxidant capacity was given by Cedrus deodara (91.4%) and the lowest one was by Firmiana simplex (56.9%). At lipid peroxidation level, little malondialdehyde (MDA) was observed in Lagerstroemia indica and Ginkgo biloba, but Platanus occidentalis, Castanoposis cuspidata var, sieboldii, Machilus thunbergii and Juniperus chinensis showed high MDA content. Antioxidant capacity of the deciduous woody plants was not significantly different in comparison with that of the evergreen ones. But MDA content of the deciduous woody plants was lower than that of the evergreen ones. The 27 taxa of woody plants appeared to be classified into four types: those of high antioxidant capacity and low lipid peroxidation, those of high antioxidant capacity and high lipid peroxidation, those of low antioxidant capacity and low lipid peroxidation, and those of low antioxidant capacity and high lipid peroxidation. The taxa included in these types are 7 (first type), 6 (second one), 8 (third one) and 6 (fourth one) taxa. first or second type species which have a high antioxidant capacity represented low nitrogen content in their leaves. However, third or forth type species which have low antioxidant capacity showed high nitrogen content in their leaves. Metasequoia glyptostroboides, Platycarya strobilacra and P. occidentalis which belong to the first or second type had extraordinarily high antioxidant capacity and high nitrogen content. Thus, three species are considered to be good phytoremediators for an industrial complex area.

Quality Control on the BOD, COD, TN, TP of Water Quality Pollutant (수질오염물질 BOD, COD, TN, TP의 정도관리(I))

  • Park, Sun-Ku;Kim, Tae-Seung;Ryu, Jae-Kyun
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.312-317
    • /
    • 1999
  • Quality control was carried out the three analytes, BOD, COD, TN, TP of high and low concentration for thirteen laboratories. Evaluation values of Quality control was determined from average value which were made by six times test, repeatedly and periodically. This value had not only error ratio of within 5% from prepared sample value but also high precision of standard deviation, 0.44 (BOD, low concentration), 2.15 (BOD, high concentration), 0.12 (COD, low concentration), 1.63 (COD, high concentration), 0.35 (TN, low concentration), 1.99 (TN, high concentration), 0.05 (TP, low concentration), 0.14 (TP, high concentration). Upper (Lower) Warning Limit (ULWL) and Upper (Lower) Acceptance Limit (ULAL) values made from quality control chart. Three (5.30, 9.70, 5.30 mg/L) and five laboratories were over ULAL value in low and high BOD concentration, respectively. Two (41.00, 30.60 mg/L) and four laboratories were over ULAL value in low and high COD concentration, respectively. while, other eleven laboratories appeared reliable data. One laboratory (0.70 mg/L) was over ULAL at low TN concentration, while other eleven laboratories had reliable values. In case of high TN concentration, eleven laboratories were over ULAL value, it should be focuced for improvement of reliability about measurement and analysis of TN. Four (1.14, 0.45, 0.64, 1.49mg/L) and seven laboratories were over ULAL in low and high TP concentration, respectively.

  • PDF

Study on the Decontamination of Primary Cooling Pump in HANARO (하나로 1차 냉각펌프 제염에 대한 고찰)

  • An Jung-Sug;Lee Kyung-Ho;Kim Kwang-Dug;Park Young-Chul
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.21-29
    • /
    • 2005
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Recently, ten years after the initial operation of the HANARO, one of the two primary cooling pumps was decontaminated for overhaul maintenance in 2004. Before decontamination exposure doserate and surface contamination level of primary cooling pump measured at 4 points. After final decontamination exposure doserate and surface contamination level of primary cooling pump remeasured by same method done before. It is easy to decontaminate the out side exposed surfaces of the pump, but it is difficult to approach the inside surface due to double volute installed in the casing. Therefore, a new decontamination facility has been developed to solve this problem. A concentrated de-contaminant (DX-300) is rotated in the closed pump casing by the impeller actuated by a temporary motor. Nuclide particles are removed by the emulsification effect of the de-contaminant and the surface contaminants are chemically removed from the pump by the corrosion and dissolution effect. The inside surfaces of the primary cooling pump have been decontaminated by using the facility. As results, the contamination level of the inside surfaces was maintained below the surface contamination limit.

  • PDF

1,3-bisdicyanovinylindane 색소를 이용한 선택적 $Hg^{2+}$ 감지 특성

  • Kim, Su-Ho;Kim, Young-Sung;Kim, Sung-Hoon;Son, Young-A
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2009.11a
    • /
    • pp.19-20
    • /
    • 2009
  • 최근 화학, 물리, 생명과학, 전기, 전자등의 다양한 분야에 활발하게 연구가 이루어지고 있는 초분자 화학은 선택적 분자인지를 위한 효율적인 골격구조와 나아가 다양한 계에 응용할 수 있다. 초분자 화학의 분자인지 과정의 특징은 일반적으로 수용체 (receptor 혹은 host)가 목표가 되는 기질 (substrate, analyte, 혹은 guest)에 대하여 선택적으로 식별하고 반응하는 것이다. 비공유 결합성 상호작용에 의하여 이루어지는 초분자 화학의 분자 인지 과정의 특징은 일반적으로 수용체 (receptor 혹은 host)가 목표가 되는 기질 (substrate, analyte, 혹은 guest)에 대하여 선택적으로 식별하고 반응하는 것이다. 이는 공유결합을 이용하는 분자화학과는 차별화 된 것이다. 수용체는 간단한 구조의 화합물 및 금속 이온들과 같은 기질과 가역적으로 상호 작용할 수 있는 착물을 형성한다. 최근들어 급격한 산업화가 진행되어 환경문제가 심각하게 대두 되어져 왔고, 그 중에서 특히 수은이나 카드뮴에 의한 질병, 납에 의한 중독 등 중금속에 의한 오염이 크게 나타남에도 불구하고, 현재 그러한 중금속을 검출함에 있어 많은 비용과 시간이 드는 문제점이 있다. 또한 우리에게 이로운 금속은 효율적 분석을 통해 환경계와 의료계에 많은 도움을 줄 것으로 사례되므로 화학센서 기술의 개발은 절실히 요구되어지고 있다. 이에 새로운 1,3-bisdicyanovinylindane 을 통해 $Hg^{2+}$ 금속의 감지 여부 알아보고, 그 특성을 파악하고자 한다. 1,3-indandion (2.18g, 14.9mmol), malononitrile (2.95g, 44.7mmol), ethanol 50ml를 20분간 상온에서 용해시킨다. 후에 sodium trihydrate acetate(3.05g)을 첨가한 후 5시간 동안 환류반응 시킨다. 이 과정에서 얻어진 용액을 필터과정을 통하여 에서 합성 반응 중에 생성된 불순물(1,3-dicyanovinylindane-1-one, monocondensation)을 제거한다. 필터과정을 통해 걸러진 미 반응 물질을 제�G 용반응욕액을 증류수(100ml)를 이용하여 희석시키고 난 후 염산을 이용, 산성화 시켜 고체 생성물을 얻어낸다. 이렇게 생성된 고체 생성물은 다시 필터 및 건조를 통하여 회색의 고체 화합물을 얻어낸다. 1,3-bisdicyanovinylindane과 금속이온에 대한 감응도를 확인하기 위하여 metanol/water(1:2)을 용매로 하여 금속이온의 농도를 변화시켜 발색특성을 살펴보았다. 본 색소화합물과 Hg2+에 대한 UV 흡광도 변화 적정결과와 그 화합물의 상태 살펴본 결과 금속이온이 0.2ml씩 더 참가되면서 색의 변화를 뚜렷하게 나타내었다. 반면 그 밖에 이온($Fe^{3+}$, $Ag^{2+}$, $Pd^{2+}$, $Zn^2$, $Fe^{2+}$, $Cu^{2+}$, $Pb^{2+}$)은 UV 흡광도 변화가 적거나 변화 자체가 없었다. 하지만 과량의 $Fe^{3+}$, $Ag^{2+}$, $Pd^{2+}$는 색상 변화를 나타내었으며,이와 같은 흡광도 변화는 금속에 따라 약간의 차이가 있지만, 420nm를 등흡수점으로 하여, 580nm의 파장 영역에 있는 흡수 밴드의 세기는 감소하는 반면 400nm 파장 영역에 있는 흡수 밴드의 세기가 증가하였다. 1,3-bisdicyanovinylindane 화합물은 다양한 생물계 및 환경계에서 요구되는 micro mol에서 milli mol 농도 영역의 $Hg^{2+}$ 이온의 선택적이고 민감한 검출과 정량적인 분석에 유용하게 사용될 수 있을 것이다.

  • PDF

Establishment of Elution and Concentration Procedure for Rapid and Sensitive Detection of Norovirus in Foods of Diverse Matrices (다양한 매트릭스가 혼합된 식품을 대상으로 노로바이러스 신속검출을 위한 탈리 및 농축방법 확립)

  • Ahn, Jaehyun;Kwon, Youngwoo;Lee, Jeong-Su;Choi, Weon Sang
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.2
    • /
    • pp.150-158
    • /
    • 2015
  • This article reports the development of an effective test procedure for detection of norovirus (NoV) in foods of diverse matrices. In this study, target foods included fermented milk, soybean paste, powders made from uncooked grains and vegetables, sesame leaves preserved in soy sauce, pickled mooli, and mooli. Viral recovery varied depending on the food matrices or elution buffers tested. Buffers were compared to determine effective elution buffers from artificially virus-contaminated foods. The conventional test procedure for concentrating viruses from food (elution-polyethylene glycol(PEG) precipitation-chloroform-PEG precipitation) was modified to save time by eliminating one PEG precipitation step. The modified procedure (elution-chloroform-PEG precipitation) was able to concentrate viruses more effectively than the conventional procedure. It also removed RT-PCR inhibitors effectively. The modified procedure was applied to target food for genogroup II NoV detection. NoV RNA was detected at the initial inoculum levels 3.125-12.5 RT-PCR units per 10-25 g tested food. The use of this newly established procedure should facilitate detection of low levels of norovirus in diverse foods.

Effects of Sewage Effluent on Organic Matters of Nakdong River: Comparison of Daily Loading (낙동강 수계 내 하수처리 방류수가 하류 하천 유기물에 미치는 영향: 부하량 비교)

  • Seong, Jin-Uk;Park, Je-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.45 no.2
    • /
    • pp.210-217
    • /
    • 2012
  • This study investigated the water quality of effluents from the wastewater treatment plants, located at the Gumi Complex 4, Gumi, and Wonpyong, in Gumi. DOC accounted for higher than 70% of TOC, and oxidation efficiencies, calculated from carbon, were 13~43% for BOD and 37~73% for CODMn, respectively. Based on the biological decomposition experiments, R-DOC account for higher than 70% of DOC, mostly being occupied by refractory organic matters. This indicated that the biodegradable organics occupied more proportions of organic loadings than the refractory organics. The effect of the organics from a discharge of a sewage treatment plant on rivers, Gumi industrial Complex 4, Gumi, and Wonpyong on lower streams of the Nakdong River were found to be 15%, 6% and 16% respectively. The ratio of 15% suggests that comparatively, no large portions of TOC loadings are occupied, but the problem is that the biodegradable organic matters occupy a lot more proportions than that of the refractory organic matters. Thus, it is highly estimated that the refractory organics can gradually increase the pollution level of organics and precursors of disinfection by-products to the down-stream water treatment plants.

Simulation of the flue gas treatment processes of an industrial-waste incinerator using Aspen plus (Aspen plus를 이용한 산업폐기물 소각로의 배가스 처리 공정 모사)

  • Lee, Ju-Ho;Jung, Moon-Hun;Kwon, Young-Hyun;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3246-3252
    • /
    • 2009
  • The interest on the recovery of thermal energy using the waste has been rising to solve the problems of continuous increase of waste generation and the depletion of the fossil fuel recently. The incineration has been used most popularly as a treatment process of the waste for the energy recovery. However, it is expected that incineration and design cost will increase in the treatment of air contaminant emitted from incinerator. This research has simulated the actual incinerator and the flue gas treatment system using the Aspen plus which is the software to simulate the chemical process. The incineration process is composed of the 1st and 2nd combustor to burn the waste, SNCR process to reduce the $NO_x$ using the urea, and the steam generation process to save the energy during incineration. The $Ca(OH)_2$ slurry was used as an acid gas (HCl, $SO_2$) treatment materials and the removal efficiency for the products from the neutralization of acid gas in SDA and combustion ash was simulated at the bag filter. The simulation result has been corresponded with the treatment efficiency of emitted gas from the actual industrial waste incinerator and it is presumed to be used to forecast the efficiencies of flue gas treatment system in the future.

Study on the Distributions of VOCs, Aldehydes, PAHs Concentration in Seoul Metropolitan Area (수도권 지역에서 환경대기 중 유해대기오염물질 (VOCs, Aldehydes, PAHs) 농도분포 특성 연구)

  • Han, Jin-Seok;Lee, Min-Do;Lim, Young-Jae;Lee, Sang-Uk;Kim, Young-Mi;Kong, Boo-Joo;An, Jun-Young;Hong, You-Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.5
    • /
    • pp.574-589
    • /
    • 2006
  • Although concentrations of hazardous air pollutants(HAPs) are very low in the atmosphere, a growing attention has been paid on such compounds due to their high toxicity and bioaccumulation potentials into human body. In order to control and manage the amount of these materials in ambient air, it is necessary to construct monitoring system of them and to know the current concentration level of HAPs above all. In this work, a wide range of HAPs has been measured in metropolitan area to recognize the present state of HAPs in this area. The measured concentration of VOCs was higher in order of Jeonnongdong, Jeongdong, and Yangsuri. The regional difference of VOCs concentration was also highest in spring. Its total VOCs was ranged from $15.17{\sim}41.45$ ppb. Benzene $0.43{\sim}2.32$ ppb showed similar concentration level with the result of previous researches in Seoul. This value is a little higher than the average concentration 0.92 ppb for national ambient air quality standards in Japan. The concentration of aldehydes in this study was lower than those of other researches. Previous works in Seoul metropolitan area showed that the concentration of formaldehyde and acetaldehyde were higher than 5 ppb. The concentration of gaseous and particulate PAHs was high in order of winter, spring, and summer More than 90% of PAHs with low molecular weight such as 2-rings and 3-rings PAHs existed in gas phase. On the other hands, PAHs with high molecular weight more than 5-rings PAHs almost existed in particulate. In spring, the concentration of gaseous PAHs was 24.38 $ng/m^3$ in Jeongdong. Among the particulate PAHs, the concentrations of Naphthalene, Benzo(b)fluoranthene, and Benzo(g, h, i)perylene were higher than others. Especially, the concentration of Benzo(a)pyrene, a important carcinogenic pollutant, was highest in winter 0.5 $ng/m^3$ and ranged from 0.03 to 0.3 $ng/m^3$ in spring and summer, which is lower than the monitoring result in 90's. These components were mainly originated from the vehicle exhaust or heating equipment use.

Characterization of lead isotope emission profiles in non-ferrous smelters in South Korea (국내 비철금속 제련시설에서의 납 동위원소 배출특성 연구)

  • Park, Jin-Ju;Kim, Ki-Jun;Park, Jin-Soo;Yoo, Suk-Min;Park, Kwang-Soo;Seok, Kwang-Seol;Shin, Hyung-Sun;Song, Guem-Joo;Kim, Young-Hee
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.333-339
    • /
    • 2013
  • This study was conducted to build up the inventories of Pb isotopic compositions of major Pb pollution sources in South Korea. Since non-ferrous metal smelters are one of major anthropogenic sources, two smelters for zinc, each one of smelter for lead and copper were selected for the study. The Pb concentrations and isotopic compositions of metal ores, wastewater, sludge, metal rod and produced sulfuric acid were analysed to understand the Pb isotopic patterns in environment. The isotopic ratio, $^{206}Pb/^{207}Pb$, of zinc ores from zinc smelter were in the range of 1.179~1.198 and the ratio of waste, flue gas and products samples were 1.105~1.147. This results implied that the isotopic patterns of output samples showed mixing patterns between two distinct metal ore soerces. In 2011, major importing countries of zinc ore were Australia, Peru and Mexico. Thus Pb isotopic patterns from zinc smelter is originated from the mixing patterns between less radiogenic Australian ores and more radiogenic South America's ores. Lead smelters also showed the same mixing patterns with those of zinc smelters. However copper smelter showed same Pb isotopic patterns with more radiogenic South America's ores.