• 제목/요약/키워드: 오염된 공기

검색결과 883건 처리시간 0.026초

A Study on Airborne Microorganism in Hospital (일부 병원 실내에서의 공기중 미생물 오염에 관한 연구)

  • Jung, Sun Hoi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제8권2호
    • /
    • pp.231-241
    • /
    • 1998
  • To assess biological indoor air quality in hospital, concentrations of viable airborne microbes were determined at intensive care unit(ICU), patient room (PR), outpatient waiting room(OPWR) in hospitals of large(1000 beds), middle(500 beds), small(100 beds) hospitals, respectively. Gram positive bacteria, gram negative bacteria, fungi were sampled using suctional sampling method by RCS sampler (Reuter centrifugal air sampler) and RCS GK-A agar plate. In gram positive bacteria groups, CNS(Coagulase Negative Staphylococcus), Micrococcus, Lactobacillus, S. aureus, Enterococcus, St. viridans identified. In gram negative bacteria groups, A. baumannii, Kl. peumoniae and E. coli were identified, and Penicillium was identified in fugi groups. Results of the study were as follows. 1. The highest concentrations of airborne microbes was $971CFU/m^3$ at 5:00 PM in small hospital patient room, and average concentrations of airborne microbes in large, middle and small hospitals were $282CFU/m^3$, $289CFU/m^3$ and $625CFU/m^3$, respectively. Average concentrations of airborne microbes in office(control) was $90CFU/m^3$. Thus, the small hospital showed the worst condition. 2. Representatives of 8 different genera were identified in 150 samples. The most frequently isolated organisms were Staphylococcus (73.0%), Micrococcus (20.7%) and Lactobacillus (4.7%), respectively. Pathogenic microbes isolated were A. baumannii, E. coli, Enterococcus, Kl. peumoniae, S. aureus, St. viridans and Penicillium as fungi. In office, no pathogenic microbes were identified. Average concentrations of airborne pathogenic microbes in large, middle and small hospital were $5CFU/m^3$ (2%), $11CFU/m^3$ (4%) and $12CFU/m^3$ (2%), respectively. Thus, condition in a large hospital was better than those in a middle and a small hospital.

  • PDF

Antibiosis of Cotton Fabric finished by Chamaecyparis Obtusa oil (편백나무 정유를 처리한 면섬유의 항균성)

  • Ryu, Jung-Jae;Kim, Jung-Gon;Kim, Young-Un;Park, Yong-Wan;Ko, Jung-An;Lim, Ji-Hye;Kim, Eui-Hwa
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 한국염색가공학회 2011년도 제44차 학술발표회
    • /
    • pp.80-80
    • /
    • 2011
  • 최근 환경과 건강에 대한 관심이 증대되면서, 천연 섬유를 소재로 사용한 최종 제품 역시 고급화 및 고기능화되고 있는 추세이며 섬유항균가공분야에 있어서도 천연 추출물을 이용한 항균가공이 주목을 받고 있다. 현재 항균가공에 사용되고 있는 항균제는 일반적으로 합성항균제를 사용하고 있고 이는 거의 대부분 자극성 화합물로써 인체에 잠재적 유해요인이 될 수 있고 제조 및 가공과정에서 환경오염을 유발시키는 문제점도 발생되고 있다. 반면 천연추출물을 사용할 경우 합성물질에 비해 포름알데히드 검출 등의 인체 안정성의 불안이 적어 건강차원에서 그 인식이 점차 증대되고 있는 추세이다. 천연항균물질에는 chitosan이나 식물에서 추출된 천연항균물질 등이 있는데 특히 식물에서 추출된 천연항균물질은 피톤치드(phytoncide)라고 표현되고 있으며 이는 수목들이 해충이나 미생물 등으로부터 자기방어를 위해 공기 중으로 발산하는 방향성의 항생물질을 뜻하는 말이다. 본 연구에서는 식물 중에서 피톤치드 정유의 함량이 많다고 알려진 측백나무과의 편백나무 정유를 이용하였으며 편백나무 정유가 식물성 천연 오일형태이므로 가공 처리 시 물과 계면이 발생되기 때문에 HLB(Hydrophilic Lipophlic Balance) 조건에 따른 최적 유화조건을 선정하였으며 편백나무 정유를 이용한 면직물의 항균 기능 부여를 위한 시험으로 편백나무 정유 처리 농도에 따른 항균성을 평가해 보고자 하였다. 실험 결과 편백나무 정유는 HLB 15이상 계면활성제 사용 시 물에 용해성이 좋고 안정된 에멀젼 상태를 보였으며 제조된 편백나무 정유 가공액 5%이상 처리 시 Staphylococcus aureus과 Klebsiella pneumoniae의 99.9% 정균감소율을 나타내었다.

  • PDF

A Study on Air Pollution in Indoor Gymnasiums (실내체육관에서의 공기오염에 관한 연구)

  • 윤승욱;김윤신;이종대;이철민;조용성
    • Journal of Environmental Health Sciences
    • /
    • 제26권3호
    • /
    • pp.32-37
    • /
    • 2000
  • Nowadays, a new word called SBS(sick building syndrome) has been come into existence. At the point of time when an interest about indoor air pollution and, according to this, countermeasure plan are internationally. Moreover institutional countermeasure should be attended at national level since indoor air quality in public places where many people gather is directly connected with national health. Especially indoor pollution of indoor stadia where all sorts of sports are held can give rise to every kinds of respiratory ailments to players as well as audiences. So it is presented as a main factor that indoor space of stadia is crowded with players and audiences compared with other kinds of indoor space. Therefore, in this research to analyze pollution degree of indoor circumstance for gymnasium and exercising room of folk wrestling. basketball, judo, wrestling, hapkido, swordsmanship and boxing making indoor gymnasium and exercising room an object, when 7 items were measures such as thermocircumstance(temperature, relative humidity, air current, intensity of illumination), dust, carbon monoxide, and carbon dioxide being based on the indoor environmental standard of the first clause of Article 45 of public utilization service which is showed at public hygiene of the Ministry of Health and Social Affairs, it was showed that indoor temperature, relative humidity, air current and intensity of illumination were over standard amount at the most of folk wrestling gymnasium and exercising room. Indoor density of carbon monoxide was preserved to the extent of standard amount (10ppm) at all gymnasiums but carbon dioxide was not in excess of standard amount(1,000 ppm) at most of gymnasiums. Indoor density of dust induced from respiration exceeded the standard amount (150 $\mu\textrm{g}$/㎥) at all gymnasiums of the folk wrestling. Since the folk wrestling players and participants feel physical subjective symptom seriously, in other words the degree of indoor air pollution at gymnasiums and exercising rooms of the folk wrestling is very high, fundamental solution and countermeasure plan should be presented.

  • PDF

A Study on the Concentration and Characteristics of Methicillin-resistant Staphylococci in the Indoor Air of Childcare Facilities (일부 어린이집의 실내공기 중 메치실린내성 포도알균의 오염 실태 및 특성)

  • Kim, Jong Oh;Kim, Young Jin
    • Journal of Environmental Health Sciences
    • /
    • 제39권5호
    • /
    • pp.447-455
    • /
    • 2013
  • Objectives: This study aims to understand the concentration, diversity, and antibiotic characteristics of staphylococci present in the indoor air of child-care facilities. Methods: Air sampling was performed from October 2012 to January 2013 in 120 child-care facilities in Seoul, Korea. Methicillin-resistant bacteria were selected from the total obtained airborne bacteria and subjected to 16S rRNA analysis for methicillin-resistant staphylococcal species determination. Identified staphylococcal strains were tested for resistance to a range of antibiotics. Results: Average total airborne bacterial concentration was $508.9{\pm}246.3CFU/m^3$. Indoor concentration of total airborne bacteria had a significant positive correlation with the $CO_2$ concentration in the child-care facilities. Methicillin-resistant staphylococci were present in 13.3% of the child-care facilities studied. A total of four species (S. epidermidis, S. cohnii, S. saprophyticus, S. sp.) and 55 strains were identified from the indoor air of the child-care facilities. Staphylococcus cohnii was the most common species (54.5%), followed by S. epidermidis (38.2%). All of the isolated staphylococcal strains exhibited high resistance to oxacillin, erythromycin, mupirocin, and ceftizoxime. Especially, S. saprophyticus strains showed more multidrug resistance to oxacillin, vancomycin, clindamycin, erythromycin, lincomycin, ceftizoxime, mupirocin, and tetracycline than did other species. Conclusion: The results of this study showed that a monitoring system for multidrug-resistant bacteria is needed in facilities for children, as the community-associated infections of these bacteria are increasing.

Estimating Personal Exposures to Air Pollutants in University Students Using Exposure Scenario (노출 시나리오를 이용한 대학생들의 유해 공기오염물질 노출 추정)

  • Kim, Sun-Shin;Hong, Ga-Yeon;Kim, Dong-Keon;Kim, Sung-Sam;Yang, Won-Ho
    • Journal of Environmental Science International
    • /
    • 제22권1호
    • /
    • pp.47-57
    • /
    • 2013
  • Studies evaluating the health effects of hazardous air pollutants assume that people's exposure to typical pollutant level is the same as specific regional pollutant level. However, depending on social and demographic factors, time-activity pattern of people can vary widely. Since most people live in indoor environments over 88% of the day, evaluating exposure to hazardous air pollutants is hard to characterize. Objective of this study was to estimate the exposure levels of university students of $NO_2$, VOCs(BTEX) and $PM_{10}$ using the scenarios with time-activity pattern and indoor concentrations. Using data from time-use survey of National Statistical Office in 2009, we investigated time-activity pattern of university students and hourly major action. A total of 1,057 university students on weekday and 640 on weekend spent their times at indoor house 13.04 hr(54.32%), other indoors 7.70 hr(32.06%), and transportation 2.36 hr(9.83%). Indoor environments in which university students spent their times were mainly house and school. Air pollutants concentrations of other indoor environments except house and school such as bar, internet cafe and billiard hall were higher than outdoors, indicating that indoor to outdoor ratios were above 1. According to three types of exposure scenarios, exposure to air pollutants could be reduced by going home after school.

Seasonal and Locational Concentrations of Particulate Air Pollutants in Indoor Air of Public Facilities in Taegu Area (대구지역 공중위생법 규제대상시설의 실내공기중 입자상 오염물질의 계절별 및 지점별 농도분포 특성)

  • 백성옥;송희봉
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제14권3호
    • /
    • pp.163-176
    • /
    • 1998
  • In this study, airborne particle samples were obtained to determine the concentrations of particulate air pollutants in indoor and outdoor air of public facilities in Taegu area. Total of 12 public facilities, regulated by the Public Sanitary Law, were selected as sampling sites, which include three underground arcades, one railway and two bus terminals, three general hospitals, and three department stores. In each place, sampling was carried out seasonally during the period of October 1994 to July 1995, and four samples per each site per season were collected both indoors and outdoors simultaneously. After determination of suspended particulate matter (SPM) mass concentrations, the particle samples were divided into two parts for subsequent chemical analysis: one for the analysis of trace elements and the other for water soluble ions. Seasonal levels of SPM appeared to be the highest in spring and the lowest in summer both indoors and outdoors, while locational variations of highest in statioyterminals, and lowest in department stores . SPM concentrations indoors and outdoors did not show any significant differences each other in most places . However, there were significant correlations between indoor and outdoor levels of SPM and other chemical species . These results indicates that indoor SPM levels are likely to be significantly affected by outdoor sources in many places. The most significant source of SPM was estimated to be the resuspension of soil/road dust both indoors and outdoors . The concentrations of toxic heavy metals (Pb, Cd, Cr, Cu) in underground arcades appeared to be very much lower than the established air quality guidelines for underground environments. In addition, it is likely that micro-environmental parameters such as temperature, humidity, and air velocity, play a less significant role than outdoor air quality as a factor affecting the levels of particulate pollutants in indoor environments of public facilities in Taegu area.

  • PDF

Material Stability Assessment of Low Oxygen and Heating Treatment (저산소 및 열처리법에 대한 문화재 재질 안정성 평가)

  • Jang, Han Gyeol;Baek, Na Yeon;Kang, Dai Ill
    • Journal of Conservation Science
    • /
    • 제30권2호
    • /
    • pp.149-156
    • /
    • 2014
  • Low oxygen treatment and heating treatment are used to prevent insects in the field of food science. These eco-friendly control methods can be applied to biological control technique in conservation treatment of organic cultural properties. To evaluate material stability, low-oxygen treatment and low oxygen treatment are applied to wood, pigment, paper and textile that are related to historical wooden buildings. As a result, wood moisture content declined after low oxygen treatment. But decline rate is a little, so it can be expected to turn back original state as time passes. And test result on pigment, paper, textile of chrominance and strength of test materials are stable. But after heating treatment, pigments are separated.

Characteristics of Indoor Air Quality of Acidic Air Pollutants in a Private Home During Home During the Summer Season (여름철 가정집에서의 산성오염물질에 대한 실내 공기질 특성)

  • 이학성;강병욱;강충민;여현구
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제17권2호
    • /
    • pp.193-201
    • /
    • 2001
  • Acidic air pollutants were collected to characterize indoor air quality in a residential area in the summer. All indoor and outdoor samples were measured simultaneously using an annular denuder system(ADS) in Seoul. The data set was collected from July 26 to September 11, 1997. The mean indoor/outdoor ratios measured from this study were : 0.34 for $HNO_3$; 0.91 for $HNO_2$; 0.22 for $SO_2$; 1.34 for $NH_3$; 0.78 for $PM_{2.5}(d_p$ <2.5 $mutextrm{m}$); 0.90 for $SO_{4}^{2-}$; 0.68 for $NO_{3}^{-}$ and 0.79 for $NH_{4}^{+}$. Indoor concentrations of $HNO_3$, $SO_2$ and $PM_{2.5}$ were highly correlated with the outdoor concentrations. The relationship between indoor and outdoor air is dependent, to a large extent, on the rate of air exchange between these two environments. A tracer-gas decay technique with sulfur hexafluoride ($SF_{6}$) as a tracer gas was used to estimate the air exchange of a private home in the summer. The average air exchange rate was estimated to be 23.7 hr(sup)-1. The deposition velocities for $SO_{4}^{2-}$, $NO_{3}^{-}$ and $NH_{4}^{+}$ calculated were 0.17, 0.69 abd 0.39 cm/sec, respectively.

  • PDF

Evaluation of a Diffusive Sampler for the Measurement of Formaldehyde using Colorimetric Method (흡광광도법을 이용한 포름알데히드 확산측정기의 평가)

  • Yim, Bong-Been;Kim, Sun-Kyu;Jung, Eui-Suk;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제27권6호
    • /
    • pp.606-613
    • /
    • 2005
  • The badge-type diffusive sampler for the measurement of formaldehyde in indoor air using three types of colorimetric methods such as chromotrophic acid(CTA), 3-methyl-2-benzothiazolinone hydrazone(MBTH), and 4-amino-3-hydrazino-5-mercapto-1,2,4-triazole(AHMT) method. The washing of the collection filter with several cleaning solution was effected with satisfactory results, regardless of the types of cleaning solutions. The concentrations of absorbance solution in each colorimetric method were experimentally determined by considering the sampling rates. The variation blank values in each colorimetric method was below 15%. As compared with CTA and AHMT methods, the reproducibility of MBTH method was excellent and was below 10% relative standard deviation. The collected formaldehyde mass and time-weighted concentration had a good correlation (correlation coefficient > 0.93). The limit of detection and limit of quantitation, and minimum sampling time were closely correlated to the sampling rates for the measurement of formaldehyde in each method.

Signal Processing for Stabilizing Output of Fine Dust Sensor (미세먼지 센서 출력의 안정화를 위한 신호처리)

  • Jung, Sang-Wook;Park, Jun-Hyeon;Kim, Ju-An;Kim, Jae-Wook;Cheon, Bong-Won;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2018년도 춘계학술대회
    • /
    • pp.344-346
    • /
    • 2018
  • Air pollution has become a social issue. Particularly, interest in fine dust is increasing. Various kinds of sensors are being used to measure fine dust. The most commonly used infrared detection dust sensors operate by sensing the diffraction of light through an infrared receiver and sensing the light reflected by the dust in the air. However, this method has a drawback in which accurate data analysis is difficult due to deviation caused by the noise during measurement. In order to overcome such drawbacks, in this thesis, a low pass filter algorithm of FIR(Finite Impulse Response) filter was designed and implemented.

  • PDF