• Title/Summary/Keyword: 오리피스형

Search Result 98, Processing Time 0.03 seconds

Multiphase Simulation of a Liquid Jet in a Lab-scale Ramjet Combustor (모형 램젯 연소기에서 액체제트의 다상유동 해석)

  • Oh, Jeong-Seog;Lee, Won-Nam;Lee, Jong-Geun;Santavicca, Dominique A.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.386-392
    • /
    • 2010
  • The multiphase simulation of a liquid jet in a lab-scale ramjet combustor with a plain orifice type injector was studied with a commercial CFD tool, a FLUENT program. The objectives of the current study are to analysis the breakup characteristics of a hexane liquid jet in a cross flow and to derive the correlation between flow conditions and drag force coefficients in a test section. From the result of a numerical simulation, we concluded that a DPM and Realizable $k-{\varepsilon}$ model with an enhanced wall treatment were available to simulate the multiphase flow simulation. And the calculated distribution of a hexane vapor concentration was well-matched with experimental results.

  • PDF

격납용기내 소격실에서의 수소혼합 연구

  • 박군철;최용석;이운장
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.617-622
    • /
    • 1997
  • 격납건물내 소격실에서의 수소혼합 정도를 파악하고 격실내 균일한 혼합을 좌우하는 인자의 영향을 분석하기 위하여 소규모 혼합실험을 수행했다. 본 연구에서는 해석적으로 수립된 3차원 혼합 모델의 검증을 위하여 3차원 모사가 가능하도록 실험 장치를 구성하였다. 격납용기 내에서 수소 생성의 주원인이 되는 노심으로부터의 수소거동을 분석하기 위한 기초 실험(실험 A)과 안전주입 탱크 격실에서의 수소거동을 분석하기 위해 원형 혼합 chamber를 구상했다. 기초실험 A에서는 혼합 chamber내 축 방향으로 대칭적인 오리피스형 장애물을 설치하고 실험했고 안전주입 탱크 격실을 모사한 실험 B는 영광 3&4호기를 바탕으로 축소시켜 안전주입탱크 격실내 존재하는 두충과 안전 주입 탱크 사이의 틀을 통한 혼합체의 거동을 분석했다. 실험결과 오리피스형 장애물을 설치한 기초실험에서는 원형 띠모양의 장애물이 혼합체의 거동에 큰 영향을 주지 않는 것이 관측됐지만 안전주입탱크격실 실험에서는 격실내 장애물로 존재하는 두충이 혼합체의 거동에 큰 영향을 주는 것이 관측됐다.

  • PDF

Flow Measurement of Liquid Oxygen using the Multi-hole Orifice (다공 오리피스를 이용한 액체산소 유량측정)

  • Lim, Hayoung;Lee, Jisung;Kim, Junghan;Noh, Yongoh
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1031-1035
    • /
    • 2017
  • To measure the flow rate of the liquid oxygen, two types of multi-hole orifice meter were prepared. The $C_d$ of the orifice meter was determined by the flow test using water. After performing the liquid oxygen flow test for orifice meter and Coriolis meter, the mass flow rate was calculated using the $C_d$. The error of the mass flow rate compare to Coriolis meter, A-type(1/2") was below than 0.4%, B-type(3/4") was below than 0.8%.

  • PDF

A Combination Study on the Elevation Motion Friction Compensation Parameters in Gas Spring (1) (가스 스프링 Elevation 동작 마찰력 보상 변수 조합 연구 (1))

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.657-666
    • /
    • 2017
  • In this study, factor analysis was performed to reduce the friction in the elevation motion of a stand for a 50-inchtelevision. Pipe type cross-section control was used for accurate positioning control of the piston rod. The pipe type was also compared with a labyrinth-type crosssection for the orifice. The frictional force was then reduced using gas seal lip technology. Specifications were chosen, and a volume compensation experiment was carried out using an apparatus for compensating the volume of the cylinder, which is compressed by the volume of the piston rod. Based on CAE and experimental considerations, the labyrinth-type orifice is preferred for reducing friction. For the gas seal lip technology, outer and inner diameters of ${\Phi}20$ and ${\Phi}8$ for the hollow rod were more appropriate when assuming the weight of a 50-inch television to be 30kgf. The third is that the result of total consideration in stability problem and performance of volume compensation for specification decision and volume compensation experiment is determined the final speculation of hollow rod ?8x?4 and riveting system. The last is that the labyrinth orifice is not founded that of the ${\O}0.4{\sim}0.6$ orifice both tests on 300 mm intervals.

F-O-O-F형 충돌형 injector의 분무특성 및 혼합성능에 관한 실험적 연구

  • Lee, Gwang-Jin;Kim, Yoo;Park, Hee-Ho;Kim, Sun-Jin;Moon, Deok-Yong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1999.04a
    • /
    • pp.3-3
    • /
    • 1999
  • 액체로켓에 대한 연구에서 가장 중요한 분야 중의 하나는 인젝터에 관한 것이다. 인젝터는 적정량의 산화제와 연료를 미립화 및 혼합시켜 연소실로 공급하는 것으로서, 액체로켓의 안정적 연소와 성능에 많은 영향을 미치는 요소이다. 기존의 F-O-F형 injector의 경우 산화제 오리피스가 연료쪽에 비해 면적이 크기 때문에 미립화 및 혼합이 좋지 못하다. 본 연구에 사용된 injector는 F-O-F형 injector의 산화제 오리피스 면적과 동일하게 두 개의 오리피스로 만들어 줌으로써 연료 오리피스와의 면적비를 적정수준으로 유지할 수 있다. 이는 동일한 조건하에서 Doublet injector나 Triplet injector의 경우 커지는 산화제의 오리피스를 제한시켜 주는 장점이 된다. 결과적으로 이러한 장점은 기존의 Doublet injector나 Triplet injector보다 높은 연소효율을 보이게 된다.

  • PDF

Design of Sharp-edged Type Damping Orifices for an Aircraft Door Damper (민항기 door damper용 칼날형 댐핑 오리피스의 설계)

  • Hong, Yeh-Sun;Kwon, Yong-Cheol;Kim, Chong-Hyeok;Park, Seol-Hye;Park, Ho-Yeol;Kim, Sang-Beom
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1080-1085
    • /
    • 2012
  • In this paper a sharp-edged type damping orifice for an aircraft door damper were designed, where the dynamic viscosity of working fluid were assumed to change up to 400cSt. The discharge coefficient of the damping orifice were investigated by CFD analyses and experiments. In particular, the influences of orifice diameter, edge angle, flow direction and the Reynolds number were taken into consideration. Based on this, it has been deduced how high Coulomb friction forces of damper seals is to be allowed to meet the performance criterion with respect to the orifice size.

PBMS용 조리개형 공기 역학 렌즈의 수치해석적 연구

  • Kim, Myeong-Jun;Kim, Yeong-Seok;Kim, Dong-Bin;Mun, Ji-Hun;Gang, Sang-U;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.279.2-279.2
    • /
    • 2014
  • 반도체 선폭이 20 nm급까지 감소함에 따라 기존에 수율에 문제를 끼치던 공정 외부 유입 입자뿐만 아니라, 공정 도중에 발생하는 수~수십 나노의 작은 입자도 수율에 악영향을 끼치게 되었다. 이에 따라 저압, 극청정 조건에서 진행되는 공정 중 발생하는 입자를 실시간으로 모니터링 할 수 있는 장비에 대한 수요가 발생하고 있다. Particle beam mass spectrometer (PBMS)는 이러한 요구사항을 만족할 수 있는 장비로 100 mtorr의 공정 조건에서 5 nm 이상의 입자의 직경별 수농도를 측정할 수 있는 장비이다. PBMS로 입자의 수농도를 측정하기 위해서는 PBMS 전단에서 입자를 중앙으로 집속할 필요가 있다. 공기역학렌즈는 PBMS 전단에서 입자를 집속시키기 위해 일반적으로 널리 사용되고 있는 장비로 여러 개의 오리피스로 이루어져 있다. 공기역학렌즈를 지나는 수송 유체와 입자는 이러한 연속 오리피스를 거치면서 팽창과 수축을 반복하며, 관성력의 차이로 인해 입자가 중앙으로 집속된다. 그러나 기존 공기역학렌즈는 고정된 직경의 오리피스를 사용하기 때문에 설계된 공정조건 이외에는 입자의 집속효율이 감소한다는 단점을 지닌다. 따라서 공정조건이 바뀔 경우 공기역학렌즈를 교체해야 되며, 진공이라는 환경하에서 이러한 교체는 많은 시간과 노력을 요구로 한다. 본 연구에서는 이러한 공기역학렌즈의 문제점을 해결하기 위해 다양한 공정조건에서 교체 없이 사용할 수 있는 새로운 형태의 공기역학렌즈인 조기래형 공기역학렌즈를 제안하였다. 각각의 오리피스가 중공의 직경을 변경할 수 있는 구조인 조리개의 형태로 설계되어 있어, 공정조건에 따라 중공의 직경을 변경함으로써 입자의 집속을 결정하는 요소인 Stokes number를 조절 할 수 있다. 이러한 조리개형 공기 역학 렌즈의 성능을 평가하기 위해 수치해석적인 방법을 이용하였다. 공기 역학 렌즈 전단의 압력을 0.1~10 torr까지 변화시켜가며 다양한 공정조건에서 오리피스의 직경만을 변경하여 입자 집속 가능 여부를 판단하였으며, 조리개 형태의 구조상 발생할 수 있는 leak로 인한 입자 집속 효율의 변화도 평가하였다.

  • PDF

Optimum Design of Dual Orifice Fuel Nozzle (이중 오리피스 연료 노즐 최적설계)

  • Lim, O-Kaung;Choi, Eun-Ho;Kim, Sung-Sub
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.407-416
    • /
    • 2007
  • Fuel spray nozzle has a critical effect on combustion characteristics. Mass flow rate and SMD(sauter mean diameter) were selected as design variables by using the experiment data of various types of duplex fuel nozzles for the swirl atomizers. The sensitivity of each design variable on the mass flow rate and SMD was analyzed and the uniformity of mass flow rate was investigated through the shape optimization of duel-orifice-type swirl atomizers. The design variables that have a little effect on the optimum design were excluded using the DOE(design of experiments) method, which enabled the optimization of sensitive design variables on mass flow rate and limit tolerance. The SMD of the research spray nozzle that was used in this study was found to be most similar to that of the calculation results using the Jasuja's SMD relationship. This study showed the specific characteristics of duel orifice type swirl atomizers and the optimization of these kinds of nozzle. This study provided the optimization design of mass flow rate and its allowable tolerance.

Analysis on the Internal Flow of the Hydraulic Dual Chambers Applying Various Orifice (다양한 오리피스를 이용한 연결형 공압 챔버 내부 유동 해석)

  • Cho, Kihong;Park, Jungho;Kim, Euiyong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.58-64
    • /
    • 2014
  • Hydraulic dual chamber, as the simulator for a dual pulse rocket motor, was tested by a high pressure device with various orifice-hole size being applied. Pressure difference occurs between 1st chamber and 2nd chamber depending on area ratio of the orifice to nozzle throat. Studying a design configuration of the orifice is essential to the motor development because pressure difference severely affects the rocket motor performance. It is noticed in this study that energy dissipation is caused by the vortex flow originating from the orifice as the 2nd chamber is operated. The flow field is simulated by a commercial computational fluid dynamics program, ANSYS FLUENT V14.5.