• Title/Summary/Keyword: 오류주의

Search Result 116, Processing Time 0.022 seconds

DIFFERENCES IN THE PATTERNS OF PARENTAL REARING BETWEEN DEPRESSION AND DEPRESSIVE CONDUCT DISORDER IN ADOLESCENCE (청소년의 우울증과 우울 행동 장애에서의 부모 양육 태도에 관한 연구)

  • Jeon, Seong-Il;Lee, Jung-Ho;Lee, Gi-Chul;Choi, Young-Min
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.7 no.1
    • /
    • pp.34-43
    • /
    • 1996
  • In adolescence, the symptoms of depression are more various and different from those of adult. Conduct behaviours are frequently represented in adolescent's depression. The patients who have the depression and conduct disorder are defined as depressive condor disorder in ICD-10. We hypothesized that there might be different parental rearing patterns between the patients with depression alone and the depressive conduct disorder. We applied children's depression inventory (CDI), parental rating form for conduct disorder based on DSM-III-R, and parental bonding instrument (PBI) to patients and normal control adolescent group. The results were as follows : 1) There were no significant differences in severity of depressive symptoms, maternal care, maternal overprotection, and paternal care. 2) Paternal overprotection showed significant higher scores in depressive conduct disorder group than depression group and normal control group. 3) There were positive correlations in the severity of depressive symptoms and behavior problems in all subjects. 4) There were no correlations in maternal care and overprotecion with conduct problems, but with depressive symptoms in all subject. 4) There were no correlations in paternal care with conduct problems and depressive symptoms in all subjects. 5) There were significant correlations in patienral overprotective, intrusive attitudes with conduct problems, not with depressive symptoms in all subjects.

  • PDF

Antithrombotic Activities of Cheongkookjang and Cheongkookjang Fermented with Green Tea or Mugwort (청국장 및 녹차, 쑥이 첨가된 청국장의 항혈전 활성)

  • Lee, Kyung-Ae;Jang, Jeong-Oak;Yoon, Hye-Kyung;Kim, Moo-Sung
    • Korean Journal of Microbiology
    • /
    • v.43 no.4
    • /
    • pp.298-303
    • /
    • 2007
  • Antithrombotic activities of water extract of cheongkookjang and cheongkookjang fermented with green tea or mugwort were evaluated on some antithrombosis related activities in vitro and thrombotic death inhibition in vivo. Cheongkookjang made of white soybean (Glycine max) or black small soybean (Rhynchosia nulubilis) showed potent antioxidative activities. Addition of green tea or mugwort during cheongkookjang fermentation increased the antioxidative activity, cheongkookjang with green tea showed more drastic increase compared with cheongkookjang with mugwort. Nitrite scavenging effects of the cheongkookjang extracts were prominent but the addition of green tea or mugwort seldom increased the scavenging effects. All the cheongkookjang extracts showed strong inhibitory activities on platelet aggregation. The inhibitory activities of cheongkookjang were increased considerably by addition of green tea or mugwort even with low concentration. Plasmin unit as fibrinolytic activity was not affected considerably by addition of green tea. Addition of mugwort decreased the activity transiently at low concentration ($0.3{\sim}1.0%$) but increased again slowly at higher concentration ($1{\sim}3%$). In vitro thrombotic death inhibition test, the antithrombotic activity of cheongkookjang made of black small bean with green tea was higher by about 1.5 times compared to that without green tea. As results, cheongkookjang might inhibit antithrombosis not only by fibrinolytic action but also by inhibition of platelet aggregation and antioxidative action. The addition of functional materials such as green tea or mugwort could increase the antithrombotic function, even at low concentration.

Quantitative Indices of Small Heart According to Reconstruction Method of Myocardial Perfusion SPECT Using the 201Tl (201Tl을 이용한 심근관류 SPECT에서 재구성 방법에 따른 작은 용적 심장의 정량 지표 변화)

  • Kim, Sung Hwan;Ryu, Jae Kwang;Yoon, Soon Sang;Kim, Eun Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: Myocardial perfusion SPECT using $^{201}Tl$ is an important method for viability of left ventricle and quantitative evaluation of cardiac function and now various reconstruction methods are used to improve the image quality. But in case of small sized heart, you should always be careful because of the Partial Volume Effect which may cause errors of quantitative indices at the reconstruction step. So, In this study, we compared those quantitative indices of left ventricle according to the reconstruction method of myocardial perfusion SPECT with the Echocardiography and verified the degree of the differences between them. Materials and Methods: Based on ESV 30 mL of Echocardiography, we divided 278 patients (male;98, female;188, Mean age;$65.5{\pm}11.1$) who visited the Asan medical center from February to September, 2012 into two categories; below the criteria to small sized heart, otherwise, normal or large sized heart. Filtered and output each case, we applied the method of FBP and OSEM to each of them, and calculated EDV, ESV and LVEF, and we conducted statistical processing through Repeated Measures ANOVA with indices that measured in Echocardiography. Results: In case of men and women, there were no significant difference in EDV between FBP and OSEM (p=0.053, p=0.098), but in case of Echocardiography, there were meaningful differences (p<0.001). The change of ESV especially women in small sized heard, significant differences has occurred among FBP, OSEM and Echocardiography. Also, in LVEF, there were no difference in men and women who have normal sized heart among FBP, OSEM and Echocardiography (p=0.375, p=0.969), but the women with small sized heart have showed significant differences (p<0.001). Conclusion: The change in quantitative indices of left ventricle between Nuclear cardiology image reconstruction, no difference has occurred in the patients with normal sized heart but based on ESV, under 30 mL of small sized heart, especially in female, there were significant differences in FBP, OSEM and Echocardiography. We found out that overestimated LVEF caused by PVE can be reduced in average by applying OSEM to all kinds of gamma camera, which are used in analyzing the differences.

  • PDF

The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients ($Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구)

  • Song, Young-Gyun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.470-478
    • /
    • 2008
  • Statement of problem: Use of all-ceramic prostheses fabricated with CAD/CAM systems is increasing in the dentistry. Marginal fidelity in production of all-ceramic restoration has important clinical implications and is a key consideration issue in CAD/CAM production as well. Purpose: The objective of this study was to analyse marginal fidelities of $Procera^{(R)}$ Allceram Crown. Material and methods: On 56 patients treated with $Procera^{(R)}$ system Allceram Crown at Dankook Dental Hospital, marginal discrepancies of 101 abutments were measured by stereomicroscope at coping and final restoration stages. Paired t-test and one-way analysis of variance on marginal discrepancy data were conducted to determine the presence of significant differences between measurement and measuring point stages. Results: Marginal discrepancies of final restoration ($45.82{\pm}30.84\;{\mu}m$) were lower than alumina coping ($53.84{\pm}38.83\;{\mu}m$). Furthermore, the differences were found to be statistically significant at 95% confidence level. Anterior marginal discrepancies were lower than posterior marginal discrepancies, but they were not statistically significant. Lingual marginal discrepancies were higher than other measurement sites, and the differences were found to be statistically significant at 95% confidence level. Conclusion: Within the conditions of this study, marginal fidelities of $Procera^{(R)}$ Allceram Crown were acceptable, and after porcelain build-up, marginal fitness improved over alumina coping. More careful scanning is needed for better results.

EVALUATING THE RELIABILITY AND REPEATABILITY OF THE DIGITAL COLOR ANALYSIS SYSTEM FOR DENTISTRY (치과용 디지털 색상 분석용 기기의 정확성과 재현 능력에 대한 평가)

  • Jeong, Joong-Jae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.352-368
    • /
    • 2008
  • This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal. Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE $L^*a^*b^*$values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (${\Delta}E^*$) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF