• Title/Summary/Keyword: 영상 소나

Search Result 549, Processing Time 0.024 seconds

Scanning Election Microscopic Observations on the Surface Structure of the Tick Boophilus microplus (Canestrini, 1887) Female Specimens (주사전자현징경 영상분석에 의한 Boophilus microplus 자충의 표면 미세구조)

  • Gang, Yeong-Bae;Jang, Du-Hwan
    • Parasites, Hosts and Diseases
    • /
    • v.23 no.2
    • /
    • pp.313-323
    • /
    • 1985
  • Boophilus microplus (Canestrini, 1887) female specimens were subjected to scanning electron microscopy for the observation of surface fine structures. Morphological characteristics observed were summarized as follows: 1. The palpi were wider than long, and compressed, ridged dorsally and laterally. There were usually four pairs of ventro-internal setae on the articles. 2. The hypostome dentition was usually 4/4 but occasionally 5/5. 3. The basis capituli were hexagonal dorsally and the porose area was distinct with the holes developed well. 4. There were numerous folds resembling finger prints around the female genital pore. 5. A pair of anal lobes with specified setae on them was also rocognized as one of the morphological characteristics.

  • PDF

The study on the development of intelligent optical communication system to monitor flood and water pollution (홍수 및 수질 오염 감시용 지능형 고속 광 통신 시스템 개발에 관한 연구)

  • Lee, Jin-Young
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.351-358
    • /
    • 2012
  • This study is aimed at suggesting optical communication equipment that can deliver high quality video information in high speed, to efficiently handle the flood and water pollution in the river basin. This system is cheaper than existing equipment, and can monitor optical Internet as well as the condition of equipment. Generally, the communication equipment to prevent flood is installed in an unmanned control box and operated by the flood control office situated at the fiver mouth in a long distance section. Therefore, it is hard to promptly cope with communication interruptions, which occur by the cutting or aging of the optical cable. Under the circumstances, this study suggested an efficient system that can deliver high quality video information in high speed (Optical Transmission Convert System) by using optical fiber. The system also solves problems by making use of automatic protection switching (APS) when an accident happens. Its real-time monitoring function gives notice of the problem-occurring points. The system is expected to be widely used in various areas such as intelligent traffic systems.

Texture Classification Using Wavelet-Domain BDIP and BVLC Features With WPCA Classifier (웨이브렛 영역의 BDIP 및 BVLC 특징과 WPCA 분류기를 이용한 질감 분류)

  • Kim, Nam-Chul;Kim, Mi-Hye;So, Hyun-Joo;Jang, Ick-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.2
    • /
    • pp.102-112
    • /
    • 2012
  • In this paper, we propose a texture classification using wavelet-domain BDIP (block difference of inverse probabilities) and BVLC (block variance of local correlation coefficients) features with WPCA (whitened principal component analysis) classifier. In the proposed method, the wavelet transform is first applied to a query image. The BDIP and BVLC operators are next applied to the wavelet subbands. Global moments for each subband of BDIP and BVLC are then computed and fused into a feature vector. In classification, the WPCA classifier, which is usually adopted in the face identification, searches the training feature vector most similar to the query feature vector. Experimental results show that the proposed method yields excellent texture classification with low feature dimension for test texture image DBs.

A Study on Data Association-Rules Mining of Content-Based Multimedia (내용 기반의 멀티미디어 데이터 연관규칙 마이닝에 대한 연구)

  • Kim, Jin-Ok;Hwang, Dae-Jun
    • The KIPS Transactions:PartD
    • /
    • v.9D no.1
    • /
    • pp.57-64
    • /
    • 2002
  • Few studies have been systematically pursued on a multimedia data mining in despite of the overwhelming amounts of multimedia data by the development of computer capacity, storage technology and Internet. Based on the preliminary image processing and content-based image retrieval technology, this paper presents the methods for discovering association rules from recurrent items with spatial relationships in huge data repositories. Furthermore, multimedia mining algorithm is proposed to find implicit association rules among objects of which content-based descriptors such as color, texture, shape and etc. are recurrent and of which descriptors have spatial relationships. The algorithm with recurrent items in images shows high efficiency to find set of frequent items as compared to the Apriori algorithm. The multimedia association-rules algorithm is specially effective when the collection of images is homogeneous and it can be applied to many multimedia-related application fields.

A Study on the Image Analysis Technique for the Precision Exploration of Chili Anthracnose (고추 탄저병 정밀 탐색을 위한 영상분석 기술에 대한 연구)

  • Baek, JeongHo;Kim, Nyunhee;Lee, Eungyeong;Lee, Hongseok;Kim, Song Lim;Park, Sang Ryeol;Ji, Hyeonso;Choi, Inchan;Kim, Kyung-Hwan
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.5
    • /
    • pp.73-81
    • /
    • 2020
  • One of the most important vegetables consumed in Korea, chili peppers (Capsicum annuum) are widely cultivated around the world. Chili peppers have been severely damaged by anthracnose during their growth, so it is important to study prevention and resistance varieties. K1 anthracnose was inoculated against four cultivar of chili peppers that are resistant to anthracnose and one cultivar that is sensitive. The area of the disease that appeared over time was photographed and quantified through the program was analyzed. Through the ratio of the area of chili pepper fruit and the area of the bottle, the sensitive variety An-S showed weak reactions to anthracnose with about 40%, the resistant variety An-12R (23%), An-Tan (21%), and An-9R (19%), and PBC81 showed a strong response to anthracnose with about 11%. These quantitative value can be used as a basis for comparison in conducting resistance studies for new varieties.

Development of Radar Rainfall Tracking Technique for the Short-Term Rainfall Forecasting (초단기강우 예측을 위한 기상레이더 강우장 추적기법 개발)

  • Kim, Tae-Jeong;So, Byung-Jin;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.2-2
    • /
    • 2015
  • 최근 국지성 집중호우 및 돌발홍수와 같은 급격한 기상변화로 인한 기상재해의 발생빈도가 증가함에 따라 기존 지상 기상관측소로부터 얻어지는 직접탐측 자료보다는 기상레이더와 위성영상 등 원격탐측 자료를 사용한 수문분야의 연구가 활발하게 진행되고 있다. 기상레이더는 넓은 지역에 걸쳐 실시간으로 강수현상 감시가 가능하며 지상우량계로는 파악이 불가능한 미계측 유역을 통과하는 국지적인 호우현상이나 강우장의 이동 및 변화의 파악도 빠른 시간에 가능한 장점이 있다. 본 연구는 기상레이더 공간적 분포와 지상관측소(AWS 및 ASOS) 자료를 연계한 통계적 레이더 강수량 추정(Quantitative Precipitation Estimation, QPE)과 레이더 강수장을 직접 추적하는 강수장 예측(Quantitative Precipitation Forecast, QPF)를 연계한 해석방안을 수립하였으며, 모형 적용과정은 다음과 같다. 첫째, 강우장의 공간적인 이동을 고려하기 위해 강우장으로 부터 이류(advection)패턴을 추출하여 각 강우세포가 가지는 이동방향 및 이동속도를 고려한 강우장 추적기법을 통하여 2시간의 선행시간을 가지는 강우장을 예측하고자 한다. 둘째, 과거 기상레이더 이미지와 지상관측소의 강수 특성을 파악한 후 앞서 예측된 레이더강우장의 형태와 가장 유사한 과거 레이더강우장과 동일 시간대에 지상관측소 강수시계열을 시나리오 형태로 구축한다. 본 연구를 통하여 개발된 기상레이더 영상 이미지 상관분석 기법을 활용한 초단기강우예측은 집중호우시 홍수 예 경보를 위한 수문모형의 입력자료로 활용이 가능하다. 즉, 수문모형과 연계한 고해상도 단기홍수 예측기술 적용이 가능할 것으로 판단되며, 향후 실시간 재해 예 경보에 활용성을 평가하고자 한다.

  • PDF

Investigation of the Time Required for General Radiography (일반 방사선검사의 소요 시간 실태조사)

  • Lim, Woo-Taek;Joo, Young-Cheol;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.255-262
    • /
    • 2022
  • In this study, by analyzing the examination time for each procedure, the appropriate workload of radiologic technologist is analyzed based on the actual examination time in the current clinical setting by comparing with the examination time in the radiology field setting of the health insurance review and assessment service. In addition, this result is introduced into the calculation of relate value units; it was attempted to provide accurate and objective evidence in the field of radiology. From May 2020 to December 2021, the study retrospectively investigated the examination times recorded in the electronic medical record and picture archiving and communication system at 5 tertiary general hospitals and 1 general hospital. The total of 16 examination parts are applied in this study, including the head, sinuses, chest, ribs, abdomen, pelvis, cervical, thoracic, lumbar, shoulder, elbow, wrist, hip, femur, knee, and ankle. The minimum number of images that could be obtained per radiation generator was 3.6 images for one hour, and the maximum was 6.4 images. When 50% median of procedure time is calculated, the minimum number of images that could be obtained was 16.7 images and maximum was 35.3 images; in addition, minimum examination time is 1.7 minutes, and maximum time is 3.6 minutes. In conclusion, it is judged that there will be insufficient explanation time for basic infection instructions such as hand hygiene during the examinations in current clinical practice. It is believed that radiologic technologists will contribute to providing higher-quality of radiation examination services to the public by complying with guidelines for work and setting appropriate workload on their own.

Analysis of water surface spectral characteristics for Chlorophyll-a estimation in Baekje weir upstream reach and Namyang lake using Drone and Sentinel-2 (백제보 상류하천구간과 남양 간척담수호내의 Chlorophyll-a 산정을 위한 Drone 및 Sentinel-2 수체분광특성 분석)

  • Jang, Wonjin;Kim, Jinuk;Lee, Yonggwan;Park, Yongeun;Kim, Seongjoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.27-27
    • /
    • 2022
  • 본 연구는 본 연구에서는 내륙에 위치한 하천(백제보)과 호소(남양호)를 대상으로 수체반사도를 활용하여 유역특성에 따른 반사도의 변화를 확인하고 Chlorophyll-a(Chl-a)의 농도를 추정하고자 하였다. 각 유역별 특성분석을 위해 제원자료, 토지피복도 및 11개(수소이온농도, 용존산소, BOD, COD, 부유물질, 총질소, 총인, 수온, 전기전도도 및 Chlorophyll-a)의 수질인자 자료를 구축하였다. 백제보는 2016-2017년 유인항공기에 탑재된 초분광센서를 이용하여 반사도를 측정하였고, 남양호는 2020-2021년 초분광센서가 탑재된 Drone과 Sentinel-2 MSI영상으로부터 반사도를 측정하였으며 두 유역 모두 촬영 범위에 대하여 현장샘플링을 실시하였다. 유역특성, 수질인자간 상관성 및 밴드별 상관성 분석을 실시하였다. 수질인자 간 상관성 분석 결과 Chl-a와 광학적 특징이 있는 SS, TOC가 상관성이 높게 나타났으며, 반사도의 경우 Chl-a가 고농도일수록 Near-Infrared, Blue 파장과 상관성이 높게 나타났다. 해당 분석결과를 기반으로 각 유역에 대해 Chl-a Machine-learning 기법과 원격탐사자료를 이용하여 Chl-a의 농도를 산정하였으며 백제보, 남양호 각각 결정계수(R2) 0.80, 0.88의 성능을 보였다. 추후 고해상도 광학위성영상을 통해 유역특성을 고려한 광범위한 지역 규모의 Chl-a의 시공간적 분석이 가능할 것으로 판단된다.

  • PDF

[ $^{18}F-FDG$ ] PET/CT in Multiple Myeloma: Is It Necessary to Include the Skull and Lower Extremity Distal to Mid-Thigh? (다발성 골수종에서의 $^{18}F$-FDG PET/CT: 전신영상 획득이 필요한가?)

  • Lee, Su-Jin; Choi, Joon-Young;Kim, Ki-Hyun;Lee, Eun-Jeong;Cho, Young-Seok;Hyun, Seung-Hyup;Lee, Ji-Young;Lee, Kyung-Han;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.1
    • /
    • pp.39-43
    • /
    • 2008
  • Purpose: We evaluated whether it was necessary to perform whole body acquisition of $^{18}F$-FDG PET/CT including whole skull and lower extremity (LE) distal to mid-thigh (MT) in patients with multiple myeloma (MM). Materials and Methods: Thirty patients underwent 45 whole body $^{18}F$-FDG PET/CT scans including skull and LE distal to MT. PET scans were divided by 2 subgroups according to the presence of abnormal focal $^{18}F$-FDG uptake in skull or LE distal to MT. Clinical characteristics including age, sex, and stages were compared between the 2 subgroups. Results: Of total 45 whole body PET/CT scans, focally increased abnormal FDG uptake in the skull or LE distal to MT suggesting myeloma involvement was found in 22 scans (48.9%) of 14 patients (46.7%). Skull lesions were more frequently observed than LE lesions distal to MT on PET (86.4% vs. 40.9%, p<0.005). There were no significant differences in age, sex, initial Durie/Salmon stage, and tumor burden at the time of PET scan suggested by serum hemoglobin level, serum calcium level, serum and urine paraprotein level, and serum creatinine level between the two subgroups. The presence of the skull or LE distal MT lesions on PET did not affect on the Durie/Salmon plus stage except only 1 case (1/22, 4.5%, p>0.05). Conclusion: Abnormal lesions in the skull or LE distal to MT on $^{18}F$-FDG PET/CT did not affect significantly on the tumor burden and Durie/Salmon plus stage of MM. Therefore, torso PET acquisition including head may be sufficient for evaluating patients with MM.

Analysis of Respiratory Motion Artifacts in PET Imaging Using Respiratory Gated PET Combined with 4D-CT (4D-CT와 결합한 호흡게이트 PET을 이용한 PET영상의 호흡 인공산물 분석)

  • Cho, Byung-Chul;Park, Sung-Ho;Park, Hee-Chul;Bae, Hoon-Sik;Hwang, Hee-Sung;Shin, Hee-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.3
    • /
    • pp.174-181
    • /
    • 2005
  • Purpose: Reduction of respiratory motion artifacts in PET images was studied using respiratory-gated PET (RGPET) with moving phantom. Especially a method of generating simulated helical CT images from 4D-CT datasets was developed and applied to a respiratory specific RGPET images for more accurate attenuation correction. Materials and Methods: Using a motion phantom with periodicity of 6 seconds and linear motion amplitude of 26 mm, PET/CT (Discovery ST: GEMS) scans with and without respiratory gating were obtained for one syringe and two vials with each volume of 3, 10, and 30 ml respectively. RPM (Real-Time Position Management, Varian) was used for tracking motion during PET/CT scanning. Ten datasets of RGPET and 4D-CT corresponding to every 10% phase intervals were acquired. from the positions, sizes, and uptake values of each subject on the resultant phase specific PET and CT datasets, the correlations between motion artifacts in PET and CT images and the size of motion relative to the size of subject were analyzed. Results: The center positions of three vials in RGPET and 4D-CT agree well with the actual position within the estimated error. However, volumes of subjects in non-gated PET images increase proportional to relative motion size and were overestimated as much as 250% when the motion amplitude was increased two times larger than the size of the subject. On the contrary, the corresponding maximal uptake value was reduced to about 50%. Conclusion: RGPET is demonstrated to remove respiratory motion artifacts in PET imaging, and moreover, more precise image fusion and more accurate attenuation correction is possible by combining with 4D-CT.