• 제목/요약/키워드: 영상편집

검색결과 442건 처리시간 0.025초

안면 비대칭 환자의 하악골 수술 후 하악골 변화에 대한 3차원 CT 영상 비교 (Comparision of Mandible Changes on Three-Dimensional Computed Tomography image After Mandibular Surgery in Facial Asymmetry Patients)

  • 김미령;진병로
    • Journal of Yeungnam Medical Science
    • /
    • 제25권2호
    • /
    • pp.108-116
    • /
    • 2008
  • Background : When surgeons plan mandible ortho surgery for patients with skeletal class III facial asymmetry, they must be consider the exact method of surgery for correction of the facial asymmetry. Three-dimensional (3D) CT imaging is efficient in depicting specific structures in the craniofacial area. It reproduces actual measurements by minimizing errors from patient movement and allows for image magnification. Due to the rapid development of digital image technology and the expansion of treatment range, rapid progress has been made in the study of three-dimensional facial skeleton analysis. The purpose of this study was to conduct 3D CT image comparisons of mandible changes after mandibular surgery in facial asymmetry patients. Materials & methods : This study included 7 patients who underwent 3D CT before and after correction of facial asymmetry in the oral and maxillofacial surgery department of Yeungnam University Hospital between August 2002 and November 2005. Patients included 2 males and 5 females, with ages ranging from 16 years to 30 years (average 21.4 years). Frontal CT images were obtained before and after surgery, and changes in mandible angle and length were measured. Results : When we compared the measurements obtained before and after mandibular surgery in facial asymmetry patients, correction of facial asymmetry was identified on the "after" images. The mean difference between the right and left mandibular angles before mandibular surgery was $7^{\circ}$, whereas after mandibular surgery it was $1.5^{\circ}$. The right and left mandibular length ratios subtracted from 1 was 0.114 before mandibular surgery, while it was 0.036 after mandibular surgery. The differences were analyzed using the nonparametric test and the Wilcoxon signed ranks test (p<0.05). Conclusion: The system that has been developed produces an accurate three-dimensional representation of the skull, upon which individualized surgery of the skull and jaws is easily performed. The system also permits accurate measurement and monitoring of postsurgical changes to the face and jaws through reproducible and noninvasive means.

  • PDF

디지탈 NTSC/PAL 비디오 부호화기의 ASIC 구현 (An ASIC Implementation of Digital NTSC/PAL Video Encoder)

  • 오승호;이문기
    • 전자공학회논문지S
    • /
    • 제35S권6호
    • /
    • pp.109-118
    • /
    • 1998
  • 본 논문에서는 압축 복원된 디지탈 RGB 또는 YCbCr 신호를 NTSC와 PAL 방송 규격에 맞는 휘도 신호와 크로마 신호 또는 영상 복합 신호로 변환 출력하는 기능을 갖는 부호화기를 설계하였다. 부호화기의 비디오 타이밍 신호는 수평 동기 신호, 수직 동기 신호, 블랭킹을 포함하며 또한 비디오를 편집하는 데 편리한 필드인식(identification) 신호를 지원한다. 부호화기는 곱셈기를 사용한 시스토릭 파이프라인 방식 [13] 에 비해 4단 파이프라인 아키텍쳐와 쉬프트-앤-가산기를 사용하여 약40%의 게이트 수를 줄였다. 설계된 부호화기는 $0.65{\mu}m$ SOG(Sea fo Gatearray) 삼중 금속 CMOS 공정 기술을 사용하여 패드를 포함한 전체 칩 면적은 $3.7478mm {\times} 4.4678mm$으로 19,468의 게이트가 집적되었으며 전력 소비는 0.9W이다.

  • PDF

Injury of the Medial Rectus Muscle by Using a Microdebrider During Endoscopic Sinus Surgery: A Case Report

  • Choi, Yoon-Seok;Bai, Chang-Hoon;Song, Si-Youn;Kim, Yong-Dae
    • Journal of Yeungnam Medical Science
    • /
    • 제23권2호
    • /
    • pp.240-246
    • /
    • 2006
  • 미세절단기를 이용한 내시경 수술이 기존의 부비동 내시경 수술에 비해 출혈이 적고 수술 시간도 단축되는 장점들이 있어 선호되고 있지만, 안와나 뇌 등의 중요 구조물에 심각한 합병증들을 발생시키기도 한다. 저자들은 만성 부비동염으로 부비동 내시경 수술 중 미세절단기에 의해 지판과 내직근 손상으로 인해 심한 복시와 외측 편위가 있었던 50세 여자 환자를 경험하였기에 문헌 고찰과 함께 보고한다. 환자는 부비동 내시경 수술 중 미세절단기에 의해 좌측 내직근 손상으로 인해 안구운동 검사상 안검연의 중심부를 통과하지 못하는 심한 내전장애 소견을 보였으며 편위각은 40 프리즘디옵터의 외사시를 나타내었다. 전산화 단층촬영상 좌측의 안와 내측벽의 손상으로 안와 지방의 노출과 좌측 내직근이 손상된 소견을 볼 수 있었다. 안구의 심한 외측 편위와 지속적인 복시는 안과적 수술을 시행하여 교정하였다.

  • PDF

소아 상부요로감염의 진단을 위한 출력 도풀러 초음파조영술 (Power Doppler Sonography for the Upper Urinary Tract Infection in Children)

  • 최정연;조재호;박용훈
    • Journal of Yeungnam Medical Science
    • /
    • 제24권2호
    • /
    • pp.179-185
    • /
    • 2007
  • 결론적으로 출력 도플러 신초음파는 급성신우신염의 병변을 찾는데에 특이도나 민감도가 그리 높지 않았으나 하부요로감염과 급성신우신염을 감별하는데에 어느 정도 유용하였으며, 특히 DMSA 스캔을 같이 실시하는 경우에는 신손상을 찾는데 더 도움이 될 수 있었다. 소아들의 상부요로감염의 진단을 위하여 출력 도플러 신초음파가 DMSA 스캔을 대체하는 영상검사로서는 한계가 있어 향후 보다 많은 시술로 진단을 위한 검사의 질을 높이는 방법을 찾아보아야 할 것이다.

  • PDF

심장 자기공명영상을 이용한 팔로사징 완전 교정술 후 우심실 기능에 대한 연구 (Investigation of right ventricle function in patients with tetralogy of Fallot after total correction using cardiac magnetic resonance imaging)

  • 장우성;최희정;이종민;김재범;김재현;장재석
    • Journal of Yeungnam Medical Science
    • /
    • 제34권2호
    • /
    • pp.238-241
    • /
    • 2017
  • Background: We investigated the difference in right ventricle (RV) volume and ejection fraction (EF) according to the pulmonary valve (PV) annular extension technique during Tetralogy of Fallot (TOF) total correction. Methods: We divided patients who underwent the procedure from 1993 to 2003 into two groups according to PV extension technique (group I: PV annular extension, group II: no PV annular extension) during TOF total correction. We then analyzed the three segmental (RV inlet, trabecular and outlet) and whole RV volume and EF by cardiac magnetic resonance imaging (MRI). Results: Fourteen patients were included in this study (group I: 10 patients, group II: four patients; male: nine patients, female: five patients). Cardiac MRI was conducted after a 16.1 years TOF total correction follow-up period. There was no statistical difference in RV segmental volume index or EF between groups (all p>0.05). Moreover, the total RV volume index and EF did not differ significantly between groups (all p>0.05). Conclusion: The RV volume and EF of the PV annular extension group did not differ from that of the PV annular extension group. Thus, PV annular preservation technique did not show the surgical advantage compared to PV annular extension technique in this study.

수치임상도 제작을 위한 영상탑재 현장조사 시스템 개발 (Development of the Field Investigation System (FIS) loading Image Data for Digital Forest Type Mapping)

  • 유병오;권수덕;김성호
    • 한국산림과학회지
    • /
    • 제97권4호
    • /
    • pp.445-451
    • /
    • 2008
  • 본 연구는 Tablet PC를 기반으로 정밀수치임상도 제작을 위한 현장조사용 맞춤형 시스템을 개발하는데 그 목적이 있다. 본 연구에서 개발한 FIS의 주요 개발내용 및 특징은 다음과 같다. FIS는 GPS에서 수신한 정보를 바탕으로 다양한 공간 Data에서 위치정보를 쉽게 파악할 수 있어 정보의 접근성이 용이한 장점이 있다. 또한 임상편집 뿐만 아니라 메모 및 야장도구를 통해 여러 가지 정보들을 현장에서 손쉽게 기록하고 관리할 수 있으며, 간단한 측정도구로 거리와 면적을 쉽게 산출할 수 있다. 본 연구에서 개발한 시스템을 활용하여 효율적인 현장조사가 가능하므로 현장에서 시간 및 비용을 절감할 수 있으며, 현장작업의 생산력이 향상될 것이다.

생물학적 유기체 모델을 이용한 가역 워터마킹 기반 비디오 콘텐츠 관리 및 제어 기법 (Reversible Watermarking based Video Contents Management and Control technique using Biological Organism Model)

  • 장봉주;이석환;권기룡
    • 한국멀티미디어학회논문지
    • /
    • 제16권7호
    • /
    • pp.841-851
    • /
    • 2013
  • 생물학적 유기체 모델에서의 바이러스 특성을 이용한 전염성 정보은닉 시스템은 비디오 인코더 및 디코더에 대해 각각 최적의 워터마크 은닉 및 검출 방법을 적용하고 비디오의 재생 또는 편집 등이 발생할 때마다 워터마크를 전이시킴으로써 각종 공격에 강인하게 함으로써 비디오 콘텐츠의 안전한 유통을 가능하게 하기 위한 방법이다. 본 논문은 전염성 정보은닉 시스템을 위한 전염성 정보의 생성과 빠르고 효율적인 가역 워터마킹 기법을 제안한다. 제안 기법은 비디오 콘텐츠 기반 가역 워터마킹을 위해 제어 코드및 콘텐츠 유효기간을 워터마크와 결합하여 전염시킨 후, 비디오 재생 시에 능동적으로 콘텐츠의 화질 및 워터마크 강도를 제어할 수 있으며, 실시간성을 만족하기 위해 계산복잡도가 낮게 설계되었다. 또한, 가역 워터마크 복원을 위한 시간지연이 발생하지 않도록 매크로블록 단위의 워터마크 및 부가정보 은닉이 수행된다. 실험결과 제안 기법이 실시간성을 만족하며, 공격받지 않은 비디오 비트스트림에 대해 가역 워터마크 검출 및 영상 복원 후 워터마크 손실은 0%였으며, 복원 후의 화질은 동일한 비트율로 압축한 비디오와 거의 동일함을 확인하였다.

라이브 시네마 연극의 매체성 연구 -케이티 미첼(Katie Mitchell)의 프로덕션 체계 분석을 중심으로- (The Mediality of Live Cinema Theatre -Katie Mitchell's Stage Constructs-)

  • 백영주
    • 한국콘텐츠학회논문지
    • /
    • 제15권11호
    • /
    • pp.27-40
    • /
    • 2015
  • 라이브 시네마 연극(Live cinema theatre)은 연극과 영상 매체가 결합된 공연 형태로서 하나의 극영화를 만드는 과정이 라이브 이벤트로서 무대화 된 것이다. 여기서 배우는 카메라를 보며 연기하며 모든 시청각적 효과는 라이브로 조합된다. 무대는 실시간으로 장면이 구성 편집되고 있는 프로덕션 상황으로서 제시되며 연극은 카메라를 매개로 스크린을 통해 관객 앞에 생중계된다. 영국 연출가 케이티 미첼(Katie Mitchell)은 이야기 전달 및 공유 과정을 효율화한다는 목적의식 아래, '라이브 시네마 연극'이란 특정용어로 작업 형태를 구별 지칭하며 이를 장르문법으로 이끌어내고 있다. 여기서 '시네마'와 '연극'은 사이성의 실험을 넘어 동기화(synchronization)를 통해 수평적 관계를 맺음으로써 각자의 위상을 유지한다. 이는 서로 다른 영역에서 독립적으로 존재하는 연극 영화의 결합을 통해 기술매체 시대에 총체의 의미를 재규정하려는 시도를 보여준다. 여기서 카메라는 무대 안팎에 현존하고 몸은 이러한 상황 안에 실존하면서, 카메라-몸-무대는 서로 불가분한 관계를 구축한다. 무대 배우들은 기술적이고 심리적인 상태를 넘나들며 카메라의 현존을 체화하고, 스텝들은 몸에서 내면성을 분리하여 외현화하며, 연출은 이를 프레임 단위로 조직함으로써 무대 위 존재양식은 뉴미디어와의 관계 안에서 재구성되고 있다.

게임에니메이션의 시각적 촉각성 연구 (Style for a Study on Visual Tactility of Game Animation)

  • 박성원
    • 한국콘텐츠학회논문지
    • /
    • 제6권11호
    • /
    • pp.110-117
    • /
    • 2006
  • 우리가 살고 있는 현 시대의 뉴미디어는 다감각적 테크놀로지에 의해 강하게 수용자를 현혹시키며 우리의 삶에 영향을 미친다. 그것들은 시각적으로 구성되어 있음에도 불구하고 마치 촉각적으로 체험하는 듯한 느낌을 준다. 현대의 대중은 온라인 미디어의 확산과 함께 일상 속에서 모든 감각을 통해 미디어를 접하고 있으며, 그 과정에서 일시적이면서도 촉감각적인 공유를 원한다. 이와 같은 흐름으로 대중사회와 영화의 출현이후, 예술은 분산적이고 촉각적인 지각방식에 호소하여 왔으며, 이 대중 적인 지각방식은 특히나 온라인 게임문화의 발달과 함께 일상 속에서 '시각적 촉지각'의 체험을 가능하게 한다. 온라인 게임의 서사를 체험할 수 있게 제작된 게임 애니메이션의 편집이 주는 쇼크작용은 바로 시각성에 촉각성을 불러일으킨다. 이러한 가정 하에 본 연구는 발터벤야민의 시각적 촉각성 이론과 영상의 몽타주 이론을 근거로 하여 게임 애니메이션을 접하는 대중의 촉각적인 충격이 단순한 그래픽 효과만이 아닌 몽타주 효과와 분산적인 수용에 의해 이루어진다는 것을 앞의 이론을 근거로 하여 설명하고자 한다.

  • PDF

전자해도 수심 밀집도 개선에 관한 연구 (A Study on improvement of sounding density of ENCs)

  • 오세웅;박종민;서상현;이문진;전태병
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2011년도 춘계학술대회
    • /
    • pp.34-36
    • /
    • 2011
  • 전자해도는 종이해도 간행을 위한 수치해도 기반으로 편집되며, 그리드 형식의 격자형 체계로 간행되고 있다. 이에 따라 전자해도에 포함되는 수심정보의 밀집도가 일관적이지 못하여 이에 대한 개선이 요구되었다. 본 연구에서는 위성영상 분류기법 중 K-Means 클러스터링 기법과 ISODATA 클러스터링 기법을 검토 하였으며, 이를 전자해도 수심정보에 맞게 수정 및 적용 하였다. 개발결과는 전자해도 로딩 부분, 수심 밀집도 개선 부분, 전자해도 쓰기 부분으로 구성되며, 알고리즘 적용 결과에 따라 수심 밀집도 개선된 결과를 확인 할 수 있었다.

  • PDF