• Title/Summary/Keyword: 영상의학과

Search Result 2,555, Processing Time 0.038 seconds

Thallium-201 SPECT in Differential Diagnosis of Malignancy from Benign Pathology in Patients with a Solitary Pulmonary Lesion (단일 폐병변에서 T1-201 SPECT를 이용한 악성 종양의 감별진단)

  • Ahn, Byeong-Cheol;Lee, Jae-Tae;Chun, Kyung-Ah;Kim, Dong-Hwan;Sohn, Sang-Kyun;Kim, Chang-Ho;Park, Jae-Yong;Jeong, Tae-Hoon;Lee, Kyu-Bo;Kim, Chun-K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.143-150
    • /
    • 1998
  • Purpose: T1-201 SPECT has been used in differentiating benign and malignant pulmonary lesions. While its sensitivity may be high, the specificity and predictive values are reported to be variable depending on the type of benign lung lesion. The purpose of this study was to prospectively assess the efficacy of T1-201 SPECT for differentiating benign and malignant single pulmonary lesion in a population with a high prevalence of benign pulmonary lesion, especially, tuberculosis. Materials and Methods: One-hundred thirty-three patients, having 89 malignant and 44 benign lesions(23 active tuberculosis, 5 inactive tuberculosis, 3 aspergil-loma, 3 focal pneumonia, 2 thymoma, and 8 others), were imaged using a dual-headed system at 15 minute(early) and 3 hour (delayed) following administration of 111MBq T1-201. The images were read visually and lesion-to-background ratios(L/B) were obtained from transverse tomographic slices. Retention index was expressed as [(delayed L/B- early L/B) $\div$ early L/B]. Results: 82/89(92%) and 83/89(93%) of the malignant lesions were visually positive on the early and delayed images, and 27/44(61%) and 26/44(59%) of the benign lesions were also visually positive on both images. Although a statistically significant difference was found between the mean L/B's of the malignant and benign lesions, L/B was not useful for differentiating the two due to a large overlap. There was no difference in retention indices. Conclusion: Despite of its high sensitivity, the specificity of T1-201 SPECT was unacceptably low in patients with active benign lesions. The positive and negative predictive values for lung cancer in a population with a high prevalence of the benign single pulmonary lesion was only marginal.

  • PDF

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Diagnostic Value of MRI in Schwannoma (신경초종 진단에 있어 자기공명영상촬영(MRI)의 진단적 가치)

  • Kim, Jeung Il;Kim, Um Ji;Moon, Tae Yong;Lee, In Sook;Song, You Seon;Choi, Kyung Un
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.20 no.2
    • /
    • pp.60-65
    • /
    • 2014
  • Purpose: To diagnose soft tissue tumor, such as lipoma and Schwannoma, magnetic resonance imaging (MRI) is sufficient in most cases. However, various characteristics are found in MRI images of Schwannoma, thus other type of tumors are often misdiagnosed as Schwannoma with MRI images. In this study, we evaluate the diagnostic value of specific MRI findings of Schwannoma. Materials and Methods: From January 2002 to May 2013, 104 patients who are suspected as Schwannoma rith MRI images are included in data, and the final diagnosis is confirmed with biopsy. Patients are divided into group 1 and group 2 who are confirmed as Schwannoma and other disease with biopsy, respectively. Results: 92 patients were diagnosed as Schwannoma (group 1) and 12 patients were diagnosed as other disease (group 2). We investigate the diagnostic value of specific MRI findings of Schwannoma. 41 patients of group 1 (45%) and 0 patients of group 2 (0%) showed target sign, 47 patients of group 1 (51%) and 2 patients of group 2 (17%) showed fascicular sign, 44 patients of group 1 (48%) and 5 patients of group 2 (42%) showed fat split sign, 28 patients of group 1 (30%) and 1 patients of group 2(9%) showed nerve entering and exiting sign, and 8 patients of group 1 (9%) and 6 patients of group 2 (50%) showed none of four specific findings on their MRI images. 52 patients of group 1 (57%) and 5 patients of group 2 (42%) have tumors on the pathway of nerve. Target sign could be considered as the best diagnostic value of the sign we investigate (p<0.05). Conclusion: Although specific MRI findings have powerful diagnostic value, patients are often misdiagnosed as Schwannoma with MRI findings. Therefore, if patients who are suspected as Schwannoma based on MRI findings have no target sign on their MRI images, we should consider the possibility of other disease.

Glomus Tumor in Soft Tissue (연부 조직에 발생한 사구종)

  • Kim, Do-Yeon;Lee, Soo-Hyun;Kim, Min-Ju;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • Purpose: Glomus tumors are rare benign vascular tumors, usually located in the skin or soft tissue of extremities. Approximately 30-50% of glomus tumors occur in subungal area, but glomus tumors have been described in every location even where glomus bodies are not or rarely present. The purpose of this study was to identify clinical, histologic and MRI characteristics of soft tissue glomus tumor. Materials and Methods: Between 1993 and 2008, eight patients underwent surgery of soft tissue Glomus tumor at our institution. Exclusion criteria were patients with Glomus tumors in digits, stomach, trachea and glomus tympanicum. We analyzed medical records, interviews, physical examinations, MR findings and histolocial types retrospectively. Results: There were four men and four women. The mean age was fourty-seven years. The mean prevalence time was eight-point-nine years. In the classic triad of symptoms, all eight patients had pain and tenderness. Two patients complained of cold sensitivity. Two showed skin color changes. After surgery, two showed symptom improvement (VAS $9^{\circ}{\rightarrow}8$, $8^{\circ}{\rightarrow}5$) and?six showed complete disappearance of symptoms. Slightly symptom improvemented (VAS $9^{\circ}{\rightarrow}8$) one had additional surgery two times after first surgery due to relapse/remaining Glomus tumor. The mean size was 13.9 mm. In histology, six were 'solid glomus tumor', one was a mixture of 'solid glomus tumor' and 'lomangioma' and one was 'malignant glomus tumor'. MR findings showed isointense signal on T1 image, high signal on T2 image and strong enhancement on the Gadolinium enhanced image. Conclusion: Glomus tumor has low recurrence rate and malignant change, rapid diagnosis and surgical excision is critical in treatment to prevent unnecessary pain of patient.

  • PDF

Evaluation of Cat Brain infarction Model Using MicroPET (마이크로 PET을 이용한 고양이 뇌 경색 모델의 평가)

  • Lee, Jong-Jin;Lee, Dong-Soo;Kim, Yun-Hui;Hwang, Do-Won;Kim, Jin-Su;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.528-531
    • /
    • 2004
  • Purpose: PET has some disadvantage in the imaging of small animal due to poor resolution. With the advent of microPET scanner, it is possible to image small animals. However, the image quality was not good enough as human image. Due to larger brain, cat brain imaging was superior to mouse or rat. In this study, we established the cat brain infarction model and evaluate it and its temporal charge using microPET scanner. Materials and Methods: Two adult male cats were used. Anesthesia was done with xylazine and ketamine HCl. A burr hole was made at 1cm right lateral to the bregma. Collagenase type IV 10 ${\mu}l$ was injected using 30 G needle for 5 minutes to establish the infarction model. $^{18}F$-FDG microPET (Concorde Microsystems Inc., Knoxville, TN) scans were performed 1, 11 and 32 days after the infarction. In addition, $^{18}F$-FDG PET scans were performed using human PET scanner (Gemini, Philips medical systems, CA, USA) 13 and 47 days after the infarction. Results: Two cat brain infarction models were established. The glucose metabolism of an infarction lesion improved with time. An infarction lesion was also distinguishable in the human PET scan. Conclusion: We successfully established the cat brain infarction model and evaluated the infarcted lesion and its temporal change using $^{18}F$-FDG microPET scanner.

Preparation and Animal Imaging of $^{153}Sm$-EDTMP as a Bone Seeking Radiopharmaceutical (골친화성 방사성의약품 $^{153}Sm$-EDTMP의 합성과 동물영상)

  • Choi, Tae-Hyun;Kim, Se-Jung;Shin, Byung-Chul;Woo, Kwang-Sun;Chung, Wee-Sup;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.44-48
    • /
    • 2005
  • Purpose: Ethylenediamine-tetramethylenephosphonic acid (EDTMP) has widely used chelator for the labeling of bone seeking radiopharmaceuticals complexed with radiometals. $^{153}Sm$ can be produced by the HANARO reactor at the Korea Atomic Energy Research Institute, Taejon, Korea. $^{153}Sm$ has favourable radiation characteristics $T1/2=46.7\;h,\;{\beta}_{max}=0.81\;MeV\;(20%),\;0.71\;MeV\;(49%),\;0.64\;MeV\;(30%)\;and\;{\gamma}=103\;keV\;(30%)$ emission which is suitable for imaging purposes during therapy. We investigated the labeling condition of $^{153}Sm$-EDTMP and imaging of $^{153}Sm$-EDTMP in normal rats. Materials and methods: EDTMP 20 mg was solved in 0.1 mL 2 M NaOH. $^{153}SmCl^3$ was added to EDTMP solution and pH of the reaction mixtures was adjusted to 3 and 12, respectively. Radiochemical purity was determined with paper chromatography. After 30 min. reaction, reaction mixtures were neutralized to pH 7.4, and the stability was estimated upto 120 hrs. Imaging studies of each reaction were perfomed in normal rats (37 MBq/0.1 mL). Results: The labeling yield of $^{153}Sm$-EDTMP was 99%. The stability of pH 8 reaction at 60, 96 and 120 hr was 99%, 95%, 89% and that of pH 12 at 36, 60, 96 and 120 hr was 99%, 95%, 88%, 66%, respectively. The $^{153}Sm$-EDTMP showed constantly higher bone uptake from 2 to 48 hr after injection. Conclusion: $^{153}Sm$-EDTMP, labeled at pH 8 reaction condition, has been stably maintained. Image of $^{153}Sm$-EDTMP at 2, 24, 48 hr after injection, demonstrate that $^{153}Sm$-EDTMP is a good bone seeking radiopharmaceuticals.

A Study on the Optimal Angle as Modified Tangential Projection of Knee Bones (무릎뼈의 변형된 접선방향 검사 시 최적의 입사각에 관한 연구)

  • Oh, Wang-Kyun;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.919-926
    • /
    • 2021
  • In this study, we wanted to find out the optimal angle as a modified tangential projection of the patella. In the experiment, we used Kyoto Kagaku's PBU-50 phantom. In the supine position, the F-T angle was set to 95°, 105°, 115°, 125°, 135°, 145°, and Patella tangential projection images were obtained by varying the X-ray tube angle by 5° so that the angle between the X-ray centerline and tibia at each angle was 5~20°. Image J was used for image analysis and the congruence angle, lateral patellofemoral angle, patellofemoral index and contrast to noise ratio(CNR) were also measured. SPSS 22 was used for statistical analysis, and the mean values of congruence angle, patellofemoral angle, patellofemoral index, and CNR were compared with Merchant method through one-way batch analysis and corresponding sample t-test. As a result of the study, in the case of congruence angle, the angle of incidence of the knee-angle X-ray centerline was 105°-72.5° (20° tangential irradiation), 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-82.5° (20° tangential irradiation), lateral patellofemoral angle is 115°-72.5°, 77.5° (15, 20° tangential irradiation), 125°-72.5° (10° tangential irradiation), patellofemoral index is 115°-72.5° (15° tangential irradiation) and 125°-72.5° (10° tangential irradiation) were not significantly different from Merchant method (p> .05). In case of CNR, it is not different from Merchant method at 105°-67.5°, 72.5° (15, 20° tangential irradiation), 115°-67.5°, 72.5°, 77.5° (10, 15, 20° tangential irradiation). (P> .05). Based on the results of this study, high diagnostic value images can be obtained by setting the knee angle and the angle of incidence of the X-ray tube to 115°-72.5° (15° tangential irradiation) during the modified tangential examination of the knee bone. It was confirmed.

A Study on the Development and usefulness of the x/y Plane and z Axis Resolution Phantom for MDCT Detector (MDCT 검출기의 x/y plane과 z축 분해능 팬텀 개발 및 유용성에 관한 연구)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.67-75
    • /
    • 2022
  • The aim of this study is to establish a new QC method that can simultaneously evaluate the resolution of the x/y plane and the z-axis by producing a phantom that can reflect exposure and reconstruction parameter of MDCT system. It was used with Aquilion ONE(Cannon Medical System, Otawara, Japan), and the examination was scanned using of 120 kV, 260 mA, and the D-FOV of 300 mm2. It produced new SSP phantom modules in which two aluminum plates inclined at 45° to a vertical axis and a transverse axis to evaluate high contrast resolution of x/y plane and z axis. And it changed factors such as the algorithm, distance from gantry iso-center. All images were reconstructed in five steps from 0.6 mm to 10.0 mm slice thickness to measure resolution of x/y plane and z-axis. The image data measured FWHM and FWTM using Profile tool of Aquarius iNtusion Edition ver. 4.4.13 P6 software(Terarecon, California, USA), and analysed SPQI and signal intensity by ImageJ program(v1.53n, National Institutes of Health, USA). It decreased by 4.09~11.99%, 4.12~35.52%, and 4.70~37.64% in slice thickness of 2.5 mm, 5.0 mm, and 10.0 mm for evaluating the high contrast resolution of x/y plane according to distance from gantry iso-center. Therefore, the high contrast resolution of the x/y plane decreased when the distance from the iso-center increased or the slice thickness increased. Additionally, the slice thicknesses of 2.5 mm, 5.0 mm, and 10.0 mm with a high algorithm increased 74.83, 15.18 and 81.25%. The FWHM was almost constant on the measured SSP graph for evaluating the accuracy of slice thickness which represents the resolution of x/y plane and z-axis, but it was measured to be higher than the nominal slice thickness set by user. The FWHM and FWTM of z-axis with axial scan mode tended to increase significantly as the distance increased from gantry iso-center than the helical mode. Particularly, the thinner slice thickness that increased error range compare with the nominal slice thickness. The SPQI increased with thick slice thickness, and that was closer to 90% in the helical scan than the axial scan. In conclusion, by producing a phantom suitable for MDCT detectors and capable of quantitative resolution evaluation, it can be used as a specific method in the management of research quality and management of outdated equipment. Thus, it is expected to contribute greatly to the discrimination of lesions in the field of CT imaging.

A Study on The Measurement of Cerebral Cortical Thickness in Patients with Mood Disorders (기분장애 환자의 대뇌 피질 두께 측정에 관한 연구)

  • Do-Hun Kim;Hyo-Young Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.73-81
    • /
    • 2024
  • This study compared the cortical thickness of patients with mood disorders and a control group to assess structural abnormalities. A retrospective study was conducted from September 2020 to August 2022 at the Department of Psychiatry, P Hospital in Yangsan, Gyeongsangnam-do. The study included 44 individuals diagnosed with mood disorders and 59 healthy individuals without any pathological lesions. The 3D-T1 MPRAGE images obtained from magnetic resonance imaging examinations were utilized, and FreeSurfer software was employed to measure cortical thickness. Statistical analysis involved independent samples t-tests to measure the differences in means between the two groups, and Cohen's d test was used to compare the effect sizes of the differences. Furthermore, the correlation between the measured average cortical thickness and Positive and Negative Syndrome Scale scores was analyzed. The research results revealed that patients with mood disorders exhibited decreased cortical thickness compared to the normal control group in both superior frontal regions, both rostral middle frontal regions, both caudal middle frontal regions, both pars opercularis, pars orbitals, pars triangularis regions, both superior temporal regions, both inferior temporal regions, both lateral orbitofrontal regions, both medial orbitofrontal regions, both fusiform regions, both posterior cingulate regions, both isthmus cingulate regions, both superior parietal regions, both inferior parietal regions, both supramarginal regions, left postcentral region, right bank of the superior temporal sulcus region, right middle temporal region, right rostral anterior cingulate region, and right insula region. Among them, regions that showed differences with effect sizes of 0.8 or higher were left fusiform (d=0.82), pars opercularis (d=0.94), superior frontal (d=0.88), right lateral orbitofrontal (d=0.85), and pars orbitalis (d=0.89). Additionally, there was a weak negative correlation between PANSS scores and average cortical thickness in both the left hemisphere (r=-0.234) and right hemisphere (r=-0.230). These findings are expected to be helpful in identifying areas of cortical thickness reduction in patients with mood disorders compared to healthy individuals and understanding the relationship between symptom severity and cortical thickness changes.