• Title/Summary/Keyword: 영상의학과의원

Search Result 7, Processing Time 0.026 seconds

A Study on Radiation Dose for General Radiography Examination at First Medical Institution (Around the Radiology Clinic of National Capital Region) (일차 의료기관에서 일반촬영 검사의 피폭선량 연구 (수도권 영상의학과를 중심으로))

  • Hwang, Su-Lyun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.245-253
    • /
    • 2011
  • The hazard level will be increased with the augmentation of the dose received by patients. Therefore, patients radiation dose have been analyzed by this study for the radiology clinics located at Seoul and Gyeongin area from August 2009 to September 2010. In the case of the front and rear directional inspection of skull, patient radiation dose was turned out to be 1.75mGy for radiology clinic, 3.00mGy for UK, 3.00mGy for Japan, and 5.00mGy for Germany, therefore, radiology clinic was the lowest. In the case of lateral directional inspection of skull, patient radiation dose was turned out to be 1.49mGy for radiology clinic, 1.50mGy for 3rd medical institution, therefore, radiology clinic was measured lower, and it was lower than 3.00mGy which is the recommended dose of IAEA. In order to reduce medical exposure of patient, optimization of efficient protection of radiation and reduction of medical radiation exposure are thought to be required by observing recommendation of international organization based on the result of this study.

Syringomatous Adenoma of the Nipple on Screening Mammography: A Case Report (선별 유방촬영술에서 발견된 유두의 한선 종양: 증례 보고)

  • Min Hyeok Yoon;Hye Jung Kim;Won Hwa Kim;Jeeyeon Lee;Ji-Young Park;Jin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1565-1569
    • /
    • 2021
  • Syringomatous adenoma of the nipples, first reported in 1983, is an extremely rare benign tumor extending to the subareolar area and, pathologically, has a shape similar to that of sweat gland tumors. Radiologically, infiltrating patterns and calcifications can cause misdiagnosis of malignant tumors. The authors report a case of syringomatous adenoma that shows only calcifications of the nipple in a screening mammography.

A Study on the Exploration of Treatment Area of Visceral Chuna Manual Therapy Using Ultrasound Image Data (초음파 영상 데이터를 활용한 내장기 추나요법 시술 부위 탐색 연구)

  • Lee, Sang-Jin;Ki, Sung-Hoon;Koh, Dong-Kyun;Lee, Sang-Hun;Lim, Hyoung-Ho;Song, Yun-Kyung
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.32 no.2
    • /
    • pp.139-154
    • /
    • 2022
  • Objectives This study was conducted to confirm anatomical information near the treatment areas of visceral chuna manual therapy and to secure stability and effectiveness during the treatment. Methods For 50 healthy adult men and women, a total of 13 ultrasound images were taken of the 7 treatment areas which are the representative treatment areas of visceral Chuna manual therapy. Results The treatment area of the bottom of the liver can be palpated around the right side ST19 and CV14. The treatment area of the gallbladder and the common bile duct can be palpated around the right side SP16 and ST20. The treatment area of the cardia and the pylorus can be palpated around the left side KI21, right side ST20, ST21, KI19, KI20, CV12, and CV13. The origin point of the mesentery root can be moved to the left and lower left from CV12 and can be palpated. The treatment area of the ileocecal valve and the cecum can be palpated around the right side SP14. The treatment area for the colic flexure can be palpated around the both side LR13. The treatment support point for the kidneys can be palpated around both side BL51. Conclusions It is thought that if the ultrasound image data from the meridians around the treatment site is used as an auxiliary, it will be more effective in terms of safety and effectiveness during the treatment of visceral Chuna manual therapy.

National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

Research of the Working Conditions of Radiological Technologists in Workplaces with Less than 300 Employees (300인 미만 사업장에서 방사선사 근무환경 실태조사)

  • Yung-Kyoon, Kim;Yon-Min, Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.1
    • /
    • pp.43-52
    • /
    • 2023
  • The purpose of this study was to investigate the actual conditions related to the working environment of radiological technologist who is working in small or medium-sized hospitals or clinics. The results of this study were intended to improve the working environment of radiological technologist and care for patients. For data collection, a structured questionnaire was used as a research tool, and 838 women (52.4%) were used as a general characteristic of 1,598 people subject to this questionnaire. The annual salary of radiological technologists with less than one year experience was 33.76 million won, and the average annual salary of radiological technologists with more than 10 years of experience was 41.33 million won. It showed an increased of 1.84% per year. Among 1,540 radiological technologists, 879 workers were paid holiday work allowances, 340 workers did not, and 321 holiday workers work during the week. In addition, a total of 817 workers received overtime payment, of which 112 received overtime wage on a monthly basis regardless of the overtime hours. In addition, a total of 348 radiological technologists were not paid overtime wage, and 138 workers were included in the basis salary. There were no union in 85% of the them. According to the results of this study, the wages and working environment of radiological technologists in small or medium-sized hospitals or clinics were not appropriate. Therefore, the efforts of the radiological association and its members are necessary to provide a better working environment for radiological technologists. In addition, it is expected that this study will be used as basic data for the association's policy to improve the working environment of members who work in poor conditions.

Influences on Time and Spatial Characteristics of Soccer Pass Success Rate: A Case Study of the 2018 World Cup in Russia (시간과 공간적 특성에 따른 축구 패스 성공률 분석: 2018 러시아 월드컵 대회 자료를 중심으로)

  • Lee, Seung-Hun;Kim, Young-Hoon
    • Journal of Digital Convergence
    • /
    • v.19 no.1
    • /
    • pp.475-483
    • /
    • 2021
  • The purpose of this study is to identify the temporal and spatial characteristics of pass accuracy by utilizing the second processing data and official records collected from the 2018 FIFA World Cup Russia video data. For a total of 128 games, the success rate of passes based on the results of the game, passing time, and passing position was two-way ANOVA with repeated measure. The results showed no difference between winning and losing groups, and no interaction effects were found for passing time and location. The difference in passing time was high in the first half, with the highest success rate in the middle of the first half (79.2%) and the middle of the second half (77.9%) in the 15~30 minutes and the 60~75 minutes. Pass success rates were in the order of defense-midfield area (83.9%), midfield-attack area (81.7%), defense area (70.6%) and attack area (61.1%). In conclusion, there was no difference in the passing success rate of the winning and losing teams depending on the characteristics of the relative competitive strength of the World Cup games, and it is believed that follow-up research is needed to analyze the game contents rather than the factors of the winning and losing in the future.

A Survey about the Knowledge, Attitudes and Behavior for Radiation Safety Management of Operating Room Nurse and Dental Hygienists (수술실 간호사와 치과위생사의 방사선 안전관리 지식과 태도 및 행위에 대한 비교조사)

  • Yoon, Jung-Ae;Yoon, Young-Suk
    • Journal of dental hygiene science
    • /
    • v.14 no.2
    • /
    • pp.230-239
    • /
    • 2014
  • This study is to promote awareness to be exposed to radiation with identifying knowledge, attitudes and behavior for radiation safety management of the operating room nurse and dental hygienist. And the following results were obtained through questionnaire survey to deduct the education to prevent potential risks in advance and implication to be useful on education program. First, based on the level of knowledge for radiation safety management, 10.57 for dental hygienists, 9.55 for the nurse out of 15 points (p<0.001); based on the level of attitudes for radiation safety management, 4.64 for dental hygienists, 4.67 for the nurse out of 5 points (p<0.001); and based on the level of behavior for radiation safety management, 3.27 for dental hygienists, 2.93 for the nurse out of 5 points (p<0.001). Second, the result for checking the relation with knowledge, attitudes and behavior for radiation safety management, the knowledge of radiation safety management has correlation with attitudes and behavior for radiation safety management statistically (p<0.001).