• Title/Summary/Keyword: 영상개선

Search Result 4,154, Processing Time 0.035 seconds

Comparison between QraypenTM Imaging and the Conventional Methods of Visual Inspection and Periapical Radiography for Proximal Caries Detection in Primary Molars: An In Vivo Study (유구치 인접면 우식 병소 진단에 있어 QraypenTM과 시진 및 구내 치근단 방사선의 비교)

  • An, So-Youn;Park, So-Young;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.16 no.5
    • /
    • pp.349-354
    • /
    • 2016
  • The purpose of this study was to evaluate the efficacy of the newly-developed $Qraypen^{TM}$ (All In One Bio, Korea) system for the diagnosis of early proximal caries by comparing it with the conventional methods of visual inspection and periapical radiography. This study was carried out from July 2015 to April 2016 targeting 32 children aged 7~12 years who visited Y-Dental Clinic for school oral health examinations. Two investigators selected and examined a total of 153 primary molars that had not undergone restorative treatment. Comparisons were carried out between visual inspections, readings of posterior periapical radiography images, and readings of $Qraypen^{TM}$ images. This study revealed that the percentage of interproximal surfaces of primary molar teeth without caries incidence was 83.7% using $Qraypen^{TM}$ imaging and 84.9% using visual inspection and periapical radiography. The differences between the two methods were not statistically significant. Thus, $Qraypen^{TM}$ is expected to be a useful and convenient auxiliary diagnostic device that can facilitate the detection of hidden proximal caries in primary molars.

Extraction of Land Characteristics using High Quality Geospatial Information (고품질 지형공간정보를 이용한 토지특성조사)

  • Jung, Woo Su;Jung, Sung Heuk;Lim, No Yeol;Kim, Gwang Ho;Lee, Soung Ki;Choi, Seok Keun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.3
    • /
    • pp.57-67
    • /
    • 2015
  • Land characteristics should be surveyed in an accurate and objective manner as they are important data to the formation of land prices. The ambiguous survey and estimation guidelines, however, make it possible for surveyors to intervene with their subjective judgments. There is thus a definite need for improvement. It is also extremely important to survey the characteristics of individual land lots in an accurate and objective manner in order to estimate officially assessed land prices in a swift and accurate way. For objective land appraisal and evaluation, this study set out to objectively identify the characteristics of lots according to various topographical conditions by using UAV based high quality geospatial information, panorama VR images, and GIS analysis technique and thus make a contribution to a rational and consistent estimation system of officially assessed land prices. Trying to assess the technique proposed in the study, the investigator analyzed the old data about the officially assessed land prices of the subject areas and then the evaluation data of certified public appraisers.

Enhancing the Reliability of MODIS Gross Primary Productivity (GPP) by Improving Input Data (입력자료 개선에 의한 MODIS 총일차생산성의 신뢰도 향상)

  • Kim, Young-Il;Kang, Sin-Kyu;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.9 no.2
    • /
    • pp.132-139
    • /
    • 2007
  • The Moderate Resolution Imaging Spectroradiometer (MODIS) regularly provides the eight-day gross primary productivity (GPP) at 1 km resolution. In this study, we evaluated the uncertainties of MODIS GPP caused by errors associated with the Data Assimilation Office (DAO) meteorology and a biophysical variable (fraction of absorbed photosynthetically active radiation, FPAR). In order to recalculate the improved GPP estimate, we employed ground weather station data and reconstructed cloud-free FPAR. The official MODIS GPP was evaluated as +17% higher than the improved GPP. The error associated with DAO meteorology was identified as the primary and the error from the cloud-contaminated FPAR as the secondary constituent in the integrative uncertainty. Among various biome types, the highest relative error of the official MODIS GPP to the improved GPP was found in the mixed forest biome with RE of 20% and the smallest errors were shown in crop land cover at 11%. Our results indicated that the uncertainty embedded in the official MODIS GPP product was considerable, indicating that the MODIS GPP needs to be reconstructed with the improved input data of daily surface meteorology and cloud-free FPAR in order to accurately monitor vegetation productivity in Korea.

Clinical Study on the Effect of Bee Venom Acupuncture Therapy on the Post-stroke Pain (뇌졸중 후 중추성 통증 환자에 대한 봉독약침요법약침 치료 효과에 대한 임상적 연구)

  • Jeoung, Kyoung-suk;Kim, Su-hyun;Park, Seon-kyeong;Lim, Ho-jae;Yoon, Hyoung-seon;Ahn, Ho-jin
    • Journal of Acupuncture Research
    • /
    • v.22 no.3
    • /
    • pp.69-75
    • /
    • 2005
  • Objective : This study is designed to find out the effect of Bee Venom Acupuncture Therapy on the Post-stroke Pain. Methods : Bee venom solution was injected on Seven Points of CVA-GB2l(肩井), LI15(肩隅), Ll11(曲池), GB31(風市), ST36(足三里), GB39(絶骨), ect- every other day for 3 weeks, in twenty patients who were admitted in Dong-Seo Oriental Medical Hospital, as diagnosed by their typical pain characteristics of central pain from stroke. Result : After 3 weeks treatment, visual analogue scale of pain severity showed significant decrease.

  • PDF

A Real-time H.264 to MPEG-2 Transcoding for Ship to Shore Communication (선박-육지간 통신을 위한 실시간 H.264 to MPEG-2 트랜스코딩)

  • Son, Nam-Rye;Jeong, Min-A;Lee, Seong-Ro
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.90-102
    • /
    • 2011
  • Recently, the grade of users using wireless communication services which transmits and re-transmits to the signal via the broadcasting satellite have a variety. However the ships not preparing of H.264 standard devices should not received the realtime data because the broadcasting stations have transmitted the compressed video data through the satellite communication. Therefore this paper proposes H.264 to MPEG-2 transcoding for the ships using MPEG-2 devices. Proposed method improves a speed and object quality in H.264 to MPEG-2 transcoding by analysis features of macroblock modes in H.264. In the Intra mode of P-frame, it proposes new method by computing coincidence proportion after comparing of Intra mode methods of H.264 and MPEG-2. In the Inter mode, it proposes a PMV(predictive motion vector) considering movement of motion vectors in H.264 decoder. we reuses a PMV directly as like the final MV in MPEG-2 encoder and refinements the MV after coincidence ratio comparing of variable motion vectors of H.264 and these of MPEG-2. The experimental results from proposed method show a considerable reduction in processing time, as much as 70% and 67% respectively, with a small objective quality reduction in PSNR.

Comparison and Optimization of Parallel-Transmission RF Coil Elements for 3.0 T Body MRI (3.0 T MRI를 위한 병렬전송 고주파 코일 구조 비교와 최적화)

  • Oh, Chang-Hyun;Lee, Heung-K.;Ryu, Yeun-Chul;Hyun, Jung-Ho;Choi, Hyuk-Jin
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.55-60
    • /
    • 2007
  • In high field (> 3 T) MR imaging, the magnetic field inhomogeneity in the target object increases due to the nonuniform electro-magnetic characteristics of the relatively high RF frequency. Especially in the body imaging, the effect causes more serious problems resulting in locally high SAR(Specific Absorption Ratio). In this paper, we propose an optimized parallel-transmission RF coil and show the utility of the coil by FDTD simulations to overcome the unwanted effects. Three types of TX coil elements are tested to maximize the efficiency and their driving patterns(amplitude and phase) optimized to have adequate field homogeneity, proper SAR level, and sufficient field strength. For the proposed coil element of $25cm{\times}8cm$ loop structure with 12 channels for a 3.0 T body coil, the field non-uniformity of more than 70% without optimization was reduced to about 26 % after the optimization of driving patterns. The experimental as well as simulation results show that the proposed parallel driving scheme is clinically useful for (ultra) high field MRI.

Effects of Flow Direction and Consolidation Pressure on Hydraulic Resistance Capacity of Soils (흐름방향과 압밀응력이 지반의 수리저항특성에 미치는 영향)

  • Kim, Youngsang;Jeong, Shinhyun;Lee, Changho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.5
    • /
    • pp.55-66
    • /
    • 2015
  • Big tidal differences, which range from 3.0 m to 8.0 m, exist with regional locations at south and west shores of Korea. Under this ocean circumstance, since a large scour may occur due to multi-directional tidal current and transverse stress of the wind, the scour surrounding the wind turbine structure can make instability of the system due to unexpected system vibration. The hydraulic resistance capacity of soils consolidated under different pressures are evaluated by Erosion Function Apparatus (EFA) under unidirectional and bi-directional flows in this study. It was found that the flow direction change affects significantly on the sour rate and critical shear stress, regardless of soil types while the consolidation pressure affects mainly cohesive soil. Among geotechnical parameters, the undrained shear strength can be well-correlated with the hydraulic resistance capacity, regardless soil type while the shear wave velocity shows the proportional relationships with the hydraulic resistance capacities of fine grained soil and coarse grained soil, respectively.

A Fast and Dynamic Region-of-Interest Coding Method using the Adaptive Code-Block Discrimination Algorithm in JPEG2000 Images (JPEG2000 이미지에서 적응적 코드블록 판별 알고리즘을 이용한 동적 고속 관심영역 코딩 방법)

  • Kang, Ki-Jun;Seo, Yeong-Geon;Park, Jae-Heung;Yoo, Chang-Yeul;Park, Soon-Hwa;Lee, Jum-Suk;Lee, Bu-Kwon
    • The KIPS Transactions:PartB
    • /
    • v.14B no.5
    • /
    • pp.321-328
    • /
    • 2007
  • In this paper, we propose a fast and dynamic Region-of-Interest coding method using the adaptive code-block discrimination algorithm in JPEG2000 images which complements the implicit ROI coding method and the modified implicit ROI coding method. For reducing the time of discriminating the code block, the proposed method estimates the characteristics of the shape of ROI and makes the shape of boundaries, and classifies the patterns of each code block. The method improves the preferred processing and loss of wavelet coefficients of background within the ROI code blocks by adaptively classifying the code blocks with the percentage of content of the wavelet coefficients using the thresholds of ROI and background. Also, the priority control of wavelet coefficients of background within ROI code block supports the rapid ROI coding by processing in batch based on patterns unlike the existing methods that process with unit of wavelet coefficients. To show the usefulness of this method, we compared this to the existing methods. There is no difference in performance, but we confirmed very speedy in processing time.

Studies on Solvent Extraction and Analytical Applications of Metal-Dithiocarbamate Complexes(Ⅰ). Extraction and Determination of Trace Bismuth, Cadmium and Indium in Sea Water (Dithiocarbamate 금속착물의 용매추출 및 분석적 응용(제 1 보). 해수중 흔적량 비스무트, 카드뮴, 인듐의 용매추출 및 정량)

  • Jeon, Moon Kyo;Choi, Jong Moon;Choi, Hee Seon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.7
    • /
    • pp.492-500
    • /
    • 1996
  • The solvent extraction of trace Bi, Cd and In in seawater samples using ammonium pyrrolidine dithiocarbamate(APDC) as a complexing agent was studied. The pH of sample solution, the amount of APDC, the type of solvent and the shaking time were investigated together with back-extraction conditions. After the pH of 200 mL seawater was adjusted to 4.0 and 5.0 mL of 1% APDC was added, analytes were extracted with 10.0 mL of MIBK by shaking for 35 minutes. The organic phase seperated was washed with a 0.05 M NaOH 10.0 mL to remove HPDC. The analytes were stripped by the back-extraction of 5 minute shaking with 5 mL of 4 M HNO3 containing 150 ㎍/mL Pd(Ⅱ). Detection limits of Bi, Cd and In were 0.038, 0.0057 and 0.023 ng/mL, respectively. Both of Bi(Ⅲ) and In(Ⅲ) were not detected in two kinds of water samples of the East Sea and the contents of Cd(Ⅱ) were 0.018 and 0.016 ng/mL. The recoveries of over 90% showed that this procedure was applicable to the determination of such trace elements in seawater samples.

  • PDF

Qualitative Evaluation of 2D Dosimetry System for Helical Tomotherapy (2차원 토모테라피 선량측정시스템의 정성적 평가)

  • Ma, Sun Young;Jeung, Tae Sig;Shim, Jang Bo;Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.193-198
    • /
    • 2014
  • The purpose of this study is to see the feasibility of the newly developed 2D dosimetry system using phosphor screen for helical tomotherapy. The cylindrical water phantom was fabricated with phosphor screen to emit the visible light during irradiation. There are three types of virtual target, one is one spot target, another is C-shaped target, and the other is multiple targets. Each target was planned to be treated at 10 Gy by treatment planning system (TPS) of tomotherapy. The cylindrical phantom was placed on the tomotherapy table and irradiated as calculations of the TPS. Every frame which acquired by CCD camera was integrated and the doses were calculated in pixel by pixel. The dose distributions from the fluorescent images were compared with the calculated dose distribution from the TPS. The discrepancies were evaluated as gamma index for each treatment. The curve for dose rate versus pixel value was not saturated until 900 MU/min. The 2D dosimetry using the phosphor screen and the CCD camera is respected to be useful to verify the dose distribution of the tomotherapy if the linearity correction of the phosphor screen improved.