• Title/Summary/Keyword: 염화도

Search Result 1,974, Processing Time 0.034 seconds

Estimation of Critical Chloride Content for Corrosion of Reinforcing Steel in Concrete by Field Exposure Experiment (현장 폭로실험에 의한 콘크리트 중 철근의 부식 임계 염화물량 평가)

  • Yu, Kyung-Geun;Bae, Su-Ho;Park, Jae-Im;Lee, Kwang-Myong;Kim, Jee-Sang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.585-588
    • /
    • 2008
  • To predict the service life of reinforced concrete structures exposed to chloride environment, quantitative measures of material properties such as the critical chloride content for corrosion in concrete and the diffusion coefficient of chloride ions of concrete and the surface chloride content of the concrete are essential. However, it should be noted that they are influenced by several factors such as concrete mix proportions, cement type, and environmental conditions, etc. Thus, the purpose of this research is to estimate more actually the critical chloride content for corrosion of the reinforcing steel in concrete by field exposure experiment. For this purpose, the prism concrete test specimens were made for water-cement(W/C) ratios of 31%, 42%, 50%, and 70%, and then the field exposure experiment for them were conducted at Youngduk of the east coast for about 3 years. During the test, corrosion monitoring by half cell potential method was carried out to detect the time to initiation of corrosion for test specimens and its chloride content was evaluated by breaking the concrete test specimens when corrosion of the reinforcing steel in concrete was perceived. It was observed from the test results that the critical chloride content for corrosion of reinforcing steel in concrete would be dependent on W/C ratio and almost irrespective of concrete cover.

  • PDF

Evaluation of Biological Effects of Low Concentrations of Mercury Chloride (II) and Ionizing Radiation in the Prepubertal Male Rats (미성숙 웅성 흰쥐를 이용한 이온화 방사선 조사 및 저농도 염화수은(II)의 음용에 따른 위해성 비교 평가)

  • Kim Ji Hyang;Kim Jin Kyu;Yoon Yong Dal
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.411-418
    • /
    • 2004
  • Mercury, one of the most diffused and hazardous organ-specific environmental contaminants, exists in a wide variety of physical and chemical states. The murcury with the nature which evaporates easily can cause an acute or chronic mercury poisoning to workers at mercury-handling workplaces. Although many studies indicate that mercury induces a deleterious damage, little has been reported from the investigations of mercury effects at surrounding levels in living things. The purpose of this study was to evaluate the biological effects of mercury chloride and ionizing radiation. Prepubertal male F344 rats were administered mercury chloride in drinking water throughout the experimental period or were given wholebody irradiation with a dose of 6.5 Gy. The amount changed of body weight during the experimental period showed a 4.9% rise in the mercury-treated group and 14.4% decline in the irradiated group compared with the level of the control group. The results of hematological analysis (red blood cells, white blood cells, hemoglobin, and hematocrit) indicated the differential effects of mercury chloride and ionizing radiation. However the concentration of cortisol as assessed by radioimmunoassay increased in both of the groups. Relative expressions of mRNA related to mitochondrion-mediated apoptosis were investigated using semiquantitative reverse transcription polymerase chain reaction on gonad and urinary organs of the experimental groups. While the expression of Bcl-2 mRNA exhibited different patterns depending on the organs or the experimental groups, both of the experimental groups showed a conspicuous expressions of Bax mRNA. In conclusion, the target organ of mercury chloride seems to be a urinary organ and the pattern of damage induced by mercury chloride differs from that by ionizing radiation.

Analysis Technique for Chloride Penetration using Double-layer and Time-Dependent Chloride Diffusion in Concrete (콘크리트내의 이중구조와 시간의존성을 고려한 염화물 해석기법의 개발)

  • Mun, Jin-Man;Kim, Jin-Yeong;Kim, Young-Joon;Oh, Gyeong-Seok;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.83-91
    • /
    • 2015
  • With varying conditions of concrete surface, induced chloride contents are changed and this is a key parameter for steel corrosion and service life in RC (Reinforced Concrete) structures. Many surface enhancement techniques using impregnation have been developed, however the evaluation techniques for chloride behavior through doubly layered media and time-dependent diffusion are rarely proposed. This paper presents an analysis technique considering double-layer concrete and time-dependent diffusion behavior, and the results are compared with those from the previous test results through reverse analysis. The chloride profiles from the surface-impregnated concrete exposed to atmospheric, tidal, submerged zone for 2 years are adopted. Furthermore surface chloride contents and diffusion coefficients are obtained, and are compared with those from Life365. Through consideration of time effect, the relative error decreases from 0.28 to 0.20 in atmospheric, 0.29 to 0.11 in tidal, and 0.54 to 0.40 in submerged zone, respectively, which shows more reasonable results. Utilizing the diffusion coefficients from Life365, relative errors increases and it needs deeper penetration depth (e) and lower diffusion coefficient ratio ($D_1/D_2$) due to higher diffusion coefficient.

Characteristics of Chloride Diffusion and Compressive Strength in the Mortar containing C12A7 based Binder and Anhydrite (C12A7계 바인더와 무수석고를 혼입한 모르타르의 염화물 확산 및 압축강도 특성)

  • Byeong-Cheol, Lho;Yong-Sik, Yoon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.450-456
    • /
    • 2022
  • In this study, as the preliminary research on the development of heating concrete members, compressive strength and accelerated chloride diffusion behavior in the mortar specimens containing C12A7 based binder and anhydrite was evaluated. Also, the effect of the mixing ratio of the citric acid based retarder was quantitatively evaluated by considering 4 levels of mixing cases. The compressive strength tests of the mortar specimen were performed referred to KS L ISO 679, and the accelerated chloride diffusion tests were performed according to NT BUILD 492 and ASTM C 1202. In the mortar with 0.3 % of retarder, the highest compressive strength was evaluated, which showed the strength development ratio of 127.6 % compared to the control case. It was considered that engineering performance was improved by effectively securing setting and curing time with 0.3 % of citric acid based retarder. As the result of the evaluation of the passed charge and the accelerated chloride diffusion coefficient, the evaluation results had similar behavior with the results of compressive strength. According to the previous study, the strength behavior and the chloride diffusion behavior had a linear relationship. The mixture showing the highest strength performance had the highest durability performance for chloride ingress, and the heating concrete development from this study will be performed in the future.

Exothermic Oil Absorbent Sheet for Low-sulfur Fuel Oil (LSFO) Spilled into Seawater in the Winter Season (동절기 해상으로 유출된 저유황 중질유 제거를 위한 발열 흡착포)

  • Park, Han-gyu;Oh, Gyung-geun;Bae, Byung-Uk;Song, Young-Chae
    • Journal of Navigation and Port Research
    • /
    • v.46 no.4
    • /
    • pp.297-302
    • /
    • 2022
  • An exothermic oil absorbent sheet with calcium chloride crystals can be fabricated, by dipping a clean polypropylene fabric in calcium carbonate and hydrochloric acid solution and drying it. The exothermic oil absorbent sheet applied to the seawater surface, releases heat by the dissociation of calcium chloride. The dissociation heat liquefies the solidified low-sulfur fuel oil at a low temperature, and converts it to a state at which it can be absorbed. The optimum mole concentrations of calcium carbonate and hydrochloric acid required for the exothermic oil absorbent sheet, are 0.25 M and 0.5 M, respectively. The oil absorption capacity of the exothermic oil absorbent sheet for low sulfur fuel oil depends on the seawater temperature. But, it is highly excellent at 4.5-7.08 g/g at 10℃, the average seawater temperature during the winter in Korea. The exothermic oil absorbent sheet is an excellent alternative in absorbing low-sulfur fuel oil in winter and removing it from seawater.

A Study on Electromagnetic Properties in OPC Mortar with Different Chloride Content (염화물을 혼입한 OPC 모르타르의 전자기 특성에 대한 연구)

  • Kwon, Seung-Jun;Na, Ung-Jin;Feng, M.Q.
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.4A
    • /
    • pp.565-571
    • /
    • 2008
  • Recently, the evaluation technique using NDT (Nondestructive Technique : NDT) is widely utilized because it makes little damage on RC (Reinforced Concrete : RC) structures. The techniques using electromagnetic properties (EM properties) are also attempted for the evaluation of the performance of concrete which is nonmetallic. For the economic manufacturing of concrete material, sea-sand is often used as aggregate, however, chloride ion in concrete has direct effects on steel corrosion and EM properties. In this study, OPC mortar specimens with 5 different chloride amount (0.0, 0.6, 1.2, 2.4, and $3.6kg/m^3$) and 3 different water-cement ratios (45%, 55%, and 65%) are prepared in order to investigate the EM properties corresponding to concrete properties. The EM properties of conductivity and dielectric constant are measured in the frequency range over 0.2~20 GHz. To facilitate the comparison of EM properties with chloride content, average values are taken respectively for the conductivity and dielectric constant measured over the 5~20 GHz frequency range. According to the results of this experiment, dielectric constant and conductivity are increased with lower W/C ratio and larger amount of chloride content.

Macrocell and Microcell Corrosion of Reinforcing Steel in Concrete Immersed in Saltwater (염수 환경하에서 콘크리트내 철근의 마크로 및 마이크로 셀 부식)

  • 이재봉;이수열;정영수;이광명;정원기;배수호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.211-214
    • /
    • 1999
  • 염화물 및 방청제가 함유된 철근 콘크리트의 부식특성을 마크로 셀 부식측정 방법인 갈바닉 전류 측정과 마이크로 셀 부식측정 방법인 선형분극 측정법 및 교류 임피던스법을 이용하여 염화물 및 방청제의 영향을 평가하였다. 마크로/마이크로 셀 부식측정기 Calcium Nitrite 방청제가 첨가된 시험체의 경우 갈바닉 전류 측정결과 낮은 전류값을 유지하였고, 교류 임피던스 측정결과 분극저항의 감소가 나타나지 않았으므로, 방청제의 첨가가 콘크리트내 철근의 부동태 피막을 보호하여 부식저항성을 향상시킴을 알 수 있었다.

  • PDF

Study on the decomposition of 1,1,2-trichloroethane in a pyrolysis reactor and a numerical study for scale-up design (열분해 반응기에서 1,1,2-trichloroethane의 분해특성과 Scale-up 설계를 위한 수치해석적 연구)

  • 이채복;라승혁;강경태;김상용
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.417-418
    • /
    • 2002
  • 열분해는 독성이 강한 염화탄화수소의 처리뿐만 아니라 염화물을 효과적으로 제거하여 이들로부터 유용한 탄화수소를 얻을 수 있는 반응이다 Biomass에 열분해를 적용하여 가스상, 액상, 고상형태의 유동한 부산물로 전환시키고 있으며 현재 액상생성물은 외국에서 큰 주목을 받고 있는 부산물이다. 1,1,2-trichloroethane(TCE)는 독성이 강한 휘발성 유기화합물(VOC)이며 발암물질이다. (중략)

  • PDF

Mechanical Properties of Polyvinyl Chloride (PVC) Sol with Surface Modified Inorganic Particles (표면개질된 무기입자 첨가에 따른 폴리염화비닐 졸의 기계적 특성)

  • Kim, Ho-Hyeong;Lee, Heung-Ryeol;Park, Jae-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.161-161
    • /
    • 2016
  • 연질 폴리염화비닐 졸 (PVC Sol) 코팅의 물리적, 화학적 내구성을 향상시키기 위하여 표면 개질된 무기물 입자를 첨가시킨 PVC 코팅을 형성하였고 그 특성을 분석하였다. 이를 통해 다양한 분야에 적용할 수 있는 고내구성 PVC sol 코팅공정을 확립하였다.

  • PDF