• Title/Summary/Keyword: 염분침투

Search Result 117, Processing Time 0.025 seconds

Studies on the Desalinization in Reclaimed Tide Lads (II) - by the Open Conduit- (간척지 제염에 관한 시험(II) - 개거에 의한 제염효과 시험-)

  • 정두호
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.12 no.3
    • /
    • pp.2029-2034
    • /
    • 1970
  • This research was attempted to study on the effects of desalinization by the depth and interval of open conduit in Kang-Hwa polder where is located at the Kil-sang Myun, Kang-Hwa Gun, Kyung-gi Do, and it has been continued for the three years from 1967 to 1969. The results obtained are as follows; 1. The depths of saline expulsion by supplying of irrigation water are approximately 30cm to 50cm under the ground surface, but saline expulsion is hardly done in case of the depth which is deeper than the above mentioned, because the moisture and saline content hardly change in such a condition. 2. The speed of vertical percolation gradually decreases below the 30cm depth, but it is noticed that there is a tendency to make the percolation of the horizental direction from its layer in Kang-Hwa reclaimed tidal land. 3. Comparing experimental treatments-varing depths and intervals of open conduits, the interval of open conduit has a more effect upon the promotion of desalinization and increasing of the rice yields than the depth of it. Therefore, according to the results of experimental data, the optimum depth of open conduit is about 0.9m, the effective interval of it is about 18m. 4. Considering the loss of arable area by the layout of open conduit, the reasonable interval of it could extend to 36m.

  • PDF

Subsurface Water Storage Using Coastal Aquifers Filled With Saline Water (염수로 포화된 해안지역 대수층을 활용한 수자원확보 방안)

  • Jung, Eun Tae;Park, Namsik;Kim, In Chul;Lee, Seoung Hwi
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.27 no.5
    • /
    • pp.353-357
    • /
    • 2015
  • A new method is proposed for water resources using aquifers in coastal areas. These aquifers are generally filled with saline water due to seawater intrusion and consequently being left unutilized. Surface water can be injected into these aquifers and recovered for water quality enhancement and stored water. Injection and pumping wells are used. For this technique to be successful protection of pumping well from seawater intrusion is an essential issue. Salt water pumping can be used to prevent saline water upconing. Numerical analysis demonstrated that a properly designed and executed salt water pumping well can protect a freshwater pumping well from salt water intrusion.

Effects of Heavy Metal and Salinity on Electrical Conductivity in Fully Saturated Sand (포화된 사질토의 전기전도도에 중금속과 염분 농도가 미치는 영향)

  • Lee, Dongsoo;Hong, Young-Ho;Hong, Won-Teak;Chae, Kwang-Seok;Lee, Jong-Sub
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.10
    • /
    • pp.23-34
    • /
    • 2017
  • As the electrical property of fully saturated soils is dependent on the pore water, it has been commonly used for the detection of the contamination into the ground. The objective of this study is to investigate the electrical characteristics according to the salinity and the lead concentration in fully saturated soils. Fresh water and saline water with the salinity of 1%, 2% and 3%, which are mixed with 6 different lead solutions with the range of 0~10 mg/L, are prepared in the cylindrical cell incorporated with sensors for measuring electrical resistance and time domain reflectometry signal. Then, the dried sands are water-pluviated into the cell. The electrical resistance and the time domain reflectometry signal are used to estimate the electrical conductivity. Test results show that electrical conductivity determined from electrical resistance at the frequency of 1 kHz continuously increases with an increase in the lead concentration, thus it may be used for the estimation of the contaminant level. In addition, the electrical conductivity estimated by the time domain reflectometry changes even at very low concentration of lead, the variation rate decreases as the lead concentration increases. Thus, the time domain reflectometry can be used for the investigation of the heavy metal leakage. This study demonstrates that complementary characteristics of electrical resistance and time domain reflectometry may be used for the detection of the leakage and contamination of heavy metal in coastal and marine environments.

A Study on the Development of Dewatering Mold Form for Performance Improvement of Concrete (콘크리트 성능개선을 위한 탈수거푸집공법의 실용화 연구)

  • Woo Kwang-Min;Lee Hak-Ki
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.88-95
    • /
    • 2003
  • Dewatering mold form get many holes on the surface to drain excessive water from combine concrete. While fiber is adhered to the forms inter surface, that makes it possible to improve concrete workability by draining excess water through the holes. We can expect the outer layer to solidify and to compact and get improvement of concretes durability. Maybe, it is valuable enough that dewatering mold form is put to practical use. On this study, the purpose is to obtain fundamental data for effective dewatering mold and properties of exposed concrete with the form, and ultimately, is to propose practical theory.

Estimation on the Durability of Metakaolin Concrete According to the W/B Ratio (물결합재비를 달리하여 제작한 메타카올린 혼입 콘크리트의 내구성능 평가)

  • Kim, Chun-Ho;Kim, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.84-91
    • /
    • 2014
  • In this study, in order to find the improvement effect of metakaolin for using improvement of strength in concrete structures, it is investigated the diffusion coefficient of chloride ions and adiabatic temperature rise test. As a result, due to the mixing of metakaolin, it has been confirmed reducing diffusion coefficient of chloride ions and could prevent down of slump for use of adding fly ash. Therefore, ensuring resistance to chloride ion penetration into concrete, it is possible to enlarge the W/B ratio and reduce the adiabatic temperature rise by mixing of metakaolin. So, it is confirmed that the durability of concrete structures is increased.

Failure Shape of RC Columns by The Degree of Corrosion of Reinforcement (철근부식정도에 따른 기둥의 파괴형태)

  • Song, Han-Beom;Oh, Sang-Hoon;Yi, Waon-Ho;Ryu, Hong-Sik;Kang, Dae-Eon;Tae, Kyung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.61-64
    • /
    • 2008
  • Reinforced Concrete structures are constructed under the basic assumption of perfect bonding between steel and concrete. The corrosion of steel in the reinforced concrete columns results in the excessive cracks and gradual deterioration of concrete between steel and concrete. The cyclic loading test was conducted with the three corrosion rates in the laboratory. Throughout this test, it is investigated a bond behavior of reinforced concrete columns under a steel corrosion. Main variables of the test are a corrosion of steel reinforcement and a level of stress.

  • PDF

Transport Coefficients and Effect of Corrosion Resistance for SFRC (강섬유 보강 콘크리트의 수송계수 및 부식저항효과)

  • Kim, Byoung-Il
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.867-873
    • /
    • 2010
  • This study investigated the corrosion properties of reinforced concrete with the addition of steel fibers. The transport properties of steel fiber-reinforced concrete such as permeable void, absorption by capillary action, water permeability and chloride diffusion were first measured to evaluate the relationship with the corrosion of steel rebar. Test results showed a slight increase on the compressive strength with the addition of steel fibers as well as considerable improvement of penetration resistance to mass transport of harmful materials into concrete. The addition of steel fibers in reinforced concrete accelerated the initiation of steel corrosion contrary to the expected results based on the measured transport properties. The NaCl ponding surface showed the spalling failure due to the corrosion expansion of steel fibers and the cut-surface around the steel rebar showed the localized steel fiber's corrosion. The wet-dry cycling with high chloride ions as well as high temperature seems to induce the increase of salt crystallization on the pores continually and the increased pressure with the steel fiber's corrosion on the pores caused the spalling failure on the exposed surface. The microcracking on the surface therefore accelerated the movement of water, chloride ions and oxygen into the embedded steel rebar. The mechanism affecting corrosion of embedded steel reinforcement with steel fibers in this study are not yet fully understood and require further study comprising of accurate experimental design to isolate the effect of steel fiber's potential mechanism on the corrosion process.

Analysis of Correlation between Freeze-Thaw Damage on Concrete and Chloride Penetration Acceleration Effect Using Surface Rebound Value (표면반발경도 활용 콘크리트 동해손상과 염분 침투 가속효과의 상관관계 분석)

  • Park, Ji-Sun;Lee, Jong-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.148-156
    • /
    • 2022
  • Although most domestic concrete structures are simultaneously exposed to freeze-thaw and chloride environments, concrete durability in the field is evaluated by each single action, and the evaluation of chloride-caused damage of concrete requires additional indoor experimental analysis of chloride contents by coring samples from structures in the field. However, in Korea, policies to strengthen facility maintenance, such as 「Special Act on the Safety Control and Maintenance of Establishments」 and 「Framework Act on Sustainable Infrastructure Management」, have been established and implemented since 2018 and facilities subject to safety inspection management by the government and local governments increases, the effective simplification technology for the inspection and diagnosis of concrete structure is needed. Therefore, this study attempted to evaluate the possibility of determining the acceleration chloride penetration of freeze-thaw damaged concrete by using the surface rebound value. For this purpose, concrete specimens already having freeze-thaw damage by exposure to the freeze-thaw acceleration environment were immersed in chloride water. After that, the acceleration relationship of chloride penetration according to freeze-thaw damage was analyzed using the amount of chloride contents in concrete.

Changes in Myrosinase Activity and Total Glucosinolate Levels in Korean Chinese Cabbages by Salting Conditions (배추 절임조건에 따른 Myrosinase 활성 및 Total Glucosinolates 함량 변화)

  • Hwang, Eun-Sun
    • Korean journal of food and cookery science
    • /
    • v.26 no.1
    • /
    • pp.104-109
    • /
    • 2010
  • Korean Chinese cabbage (Brassica campestris L. ssp. pekinensis) is one of the major cruciferous vegetables. Cruciferous vegetables contain a series of relatively unique secondary metabolites of amino acids called glucosinolates. Although glucosinolates do not appear to be bioactive, they are hydrolyzed by plant myrosinase when the cells in plants are damaged, and release biologically active compounds such as isothiocyanates, nitriles, and thiocyanates. The objective of this study was to determine the myrosinase activity and total glucosinolate levels of Korean Chinese cabbages by different salting times (0, 12, 18, and 24 h) and salt concentrations (6, 10, 14%). The total water content, salt content, and pH of brined cabbages decreased with increasing salting time. The myrosinase activity as determined by a glucose kit, decreased with increasing salting time and salt content. The total glucosinolates were purified using an anion exchange column and measured by UV-visible spectrophotometer. The fresh Korean Chinese cabbages contained $25.38{\pm}1.45\;{\mu}mol/g$ dry weight of glucosinolates. However, the total glucosinolates of brined cabbages decreased with increasing salting time and salt concentration. After 24 h of salting time, the total glucosinolates of brined cabbages rapidly decreased by $16.12{\pm}11.09$, $11.25{\pm}10.91$, $9.29{\pm}10.73\;{\mu}mol/g$ in 6%, 10%, and 14% salt solution, respectively. Overall, the total glucosinolate levels of Korean Chinese cabbages were found to vary inversely with salting time and salt concentration.

Estimation of the amount of refrigerant in artificial ground freezing for subsea tunnel (해저터널 인공 동결공법에서의 냉매 사용량 산정)

  • Son, Youngjin;Choi, Hangseok;Ko, Tae Young
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.2
    • /
    • pp.255-268
    • /
    • 2018
  • Subsea tunnel can be highly vulnerable to seawater intrusion due to unexpected high-water pressure during construction. An artificial ground freezing (AGF) will be a promising alternative to conventional reinforcement or water-tightening technology under high-water pressure conditions. In this study, the freezing energy and required time was calculated by the theoretical model of the heat flow to estimate the total amount of refrigerant required for the artificial ground freezing. A lab-scale freezing chamber was devised to investigate changes in the thermal and mechanical properties of sandy soil corresponding to the variation of the salinity and water pressure. The freezing time was measured with different conditions during the chamber freezing tests. Its validity was evaluated by comparing the results between the freezing chamber experiment and the numerical analysis. In particular, the freezing time showed no significant difference between the theoretical model and the numerical analysis. The amount of refrigerant for artificial ground freezing was estimated from the numerical analysis and the freezing efficiency obtained from the chamber test. In addition, the energy ratio for maintaining frozen status was calculated by the proposed formula. It is believed that the energy ratio for freezing will depend on the depth of rock cover in the subsea tunnels and the water temperature on the sea floor.