Heat and Flow Characteristics During Melting Process of a PCM Inside a Liquid Flexitank for Cargo Containers (화물 컨테이너용 액상 백 내부 PCM의 용융 과정에 대한 열유동 특성 해석)

  • Lilong Sun;Joon Hyun Kim;Jaehoon Na;Jaeyong Sung
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.1
    • /
    • pp.6-17
    • /
    • 2024
  • This study examined the natural convection heat flow characteristics of the melting process of PCM (palm oil) inside a liquid flexitank(bag) for a cargo container. A film heating element was installed on the bottom of the container, and numerical analysis was performed under heat flux conditions of 1,000 to 4,000 W/m2. As a result, the melt interface of the PCM rises to a nearly horizontal state over time. In the initial stage, conduction heat transfer dominates, but gradually waves at the cell flow and melt interfaces are formed due to natural convection heat transfer. As melting progresses, the Ra number increases parabolically, and the Nu number increases linearly and has a constant value. The Nu number rises slowly under low heat flux conditions, whereas under high heat flux conditions, the Nu number rises rapidly. As the heat flux increases, the internal temperature oscillation of the liquid phase after melting increases. However, under high heat flux conditions, excess heat exceeding the latent heat is generated, and the temperature of the molten liquid is raised, so the increase in melting rate decreases. Therefore, the appropriate heating element specification applied to a 20-ton palm oil container is 2,000 W/m2.

Analytical and Experimental Study on a Thermal Liquid Mass Flow Meter (가열식 액체용 질량유량계측기에 관한 이론 및 실험적 연구)

  • Kim, Taig Young;Kang, Chang Hoon;Shin, Yoon Sub;Kim, Tae Su;Choi, Seon Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.4
    • /
    • pp.309-316
    • /
    • 2015
  • Numerical analysis and experimental verification of a thermal liquid mass flow meter (LMFM) were performed. The configuration of the LMFM was the same as a gas mass flow meter (GMFM), but the opposite results in temperature difference between upstream and downstream thermistors occurred. In the case of the gas, the convection depending on the flow of thermal mass was small and comparable to the conduction through the sensor tube wall. The temperature difference was proportional to the mass flow rate due to their interaction. For the liquid flow, the convection overwhelmed the wall conduction because of the large flow of thermal mass caused by high density. The temperature difference in this case was inversely proportional to the mass flow rate. The tube diameter and heater wiring width are important design parameters, and the optimized sensor can be used to measure and control the infinitesimal liquid flow rate.

Temperature Prediction Method for Superheater and Reheater Tubes of Fossil Power Plant Boiler During Operation (화력발전 보일러 과열기 및 재열기 운전 중 튜브 온도예측기법)

  • Kim, Bum-Shin;Song, Gee-Wook;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.563-569
    • /
    • 2012
  • The superheater and reheater tubes of a heavy-load fossil power plant boiler can be damaged by overheating, and therefore, the degree of overheating is assessed by measuring the oxide scale thickness inside the tube during outages. The tube temperature prediction from the oxide scale thickness measurement is necessarily accompanied by destructive tube sampling, and the result of tube temperature prediction cannot be expected to be accurate unless the selection of the overheated point is precise and the initial-operation tube temperature has been obtained. In contrast, if the tube temperature is to be predicted analytically, considerable effort (to carry out the analysis of combustion, radiation, convection heat transfer, and turbulence fluid dynamics of the gas outside the tube) is required. In addition, in the case of analytical tube temperature prediction, load changes, variations in the fuel composition, and operation mode changes are hardly considered, thus impeding the continuous monitoring of the tube temperature. This paper proposes a method for the short-term prediction of tube temperature; the method involves the use of boiler operation information and flow-network-analysis-based tube heat flux. This method can help in high-temperaturedamage monitoring when it is integrated with a practical tube-damage-assessment method such as the Larson-Miller Parameter.

Analysis of pollutant mixing on the water surface in rivers with GPS floaters (GPS부자를 이용한 하천 표면에서의 오염물질 혼합 거동 해석)

  • Seo, Il Won;Park, Inhwan;Kim, Young Do;Han, Eun Jin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.103-103
    • /
    • 2015
  • 유류유출사고와 같이 하천 수표면의 흐름에 따라 이동 확산하는 부유성 오염물질의 혼합해석을 위해 많은 연구자들은 입자추적모형을 사용한 혼합모의를 수행해왔다. 입자추적모형에서 오염물질의 혼합은 평균 유속 분포에 의한 결정론적인 이동과 난류유동에 의한 무작위적인 혼합으로 나타내며, 난류혼합에 의한 수평확산은 난류확산계수로 조절한다. 따라서 표면흐름에 의한 난류확산계수의 산정을 위해 많은 연구자들은 부유성 입자를 이용한 실내실험을 수행하여 수평확산계수를 산정했고(Engelund, 1969; Cederwall, 1971), 최근에는 GPS의 발전으로 인해 해양영역에서 GPS를 장착한 표면부자를 활용한 확산실험을 통해 수평확산계수를 산정한 바 있다(Kjellson and $D{\ddot{o}}{\ddot{o}}s$, 2012; Alpers 등, 2013). 하천수질오염사고의 약 43.5%가 유류유출에 의한 것이며(환경부, 2013), 이에 따라 표면흐름에 의한 오염물질 혼합해석이 필요하나, 하천에서 수평확산계수 산정을 위한 현장실험연구는 부족한 상황이다. 따라서 본 연구에서는 낙동강 본류에서 GPS부자를 이용한 입자추적실험을 수행하여 표면흐름에 의한 확산계수를 산정했다. GPS부자를 이용한 입자추적실험은 낙동강의 강정고령보 하류와 구미보 하류의 각각 세 지점에서 수행되었다. GPS부자는 바람에 의한 교란을 최소화하기 위해 지름 10 cm의 구형으로 제작하였으며 시범테스트를 통해 입자의 주 궤적 변화가 크지 않은 지점에 GPS부자를 투입했다. GPS부자는 오염물질의 사고유출을 가정하여 한 지점에 투입했고 GPS부자 사이의 간섭을 최소화하기 위해 25 ~ 35개의 GPS부자를 이용했다. 표면흐름에 의해 이동하는 부자의 위치는 GPS에 시계열로 저장됐고 ADCP를 이용하여 실험당시의 수리량을 측정했다. 입자위치의 시계열자료로부터 GPS부자의 확산범위의 시간변화를 계산했고 단순 모멘트법을 이용하여 종, 횡 방향 확산계수를 계산했다. 그 결과, 종 방향 확산계수는 $0.003{\sim}0.041m^2/s$로 계산되었고 횡 방향 확산 계수는 $0.001{\sim}0.012m^2/s$로 계산되어, 흐름방향의 유속성분에 의한 확산이 지배적인 것으로 나타났다. 지류 합류부에서는 이송이 지배적인 혼합이 발생되었고(Pe>1) Pe의 증가에 따라 수평확산계수가 감소되었다. 25~35개 GPS부자 궤적의 앙상블 평균으로부터 계산한 Integral time scale은 모멘트법으로부터 계산한 종, 횡 방향 확산계수와 비례하는 것으로 나타나, Taylor(1921)의 이론과 일치했다. 또한 실험수로에서 수행된 기존연구결과와 비교한 결과, 하폭 대 수심비, 마찰항의 증가에 따라 수평확산계수가 증가하는 경향을 나타내었다.

  • PDF

A Study on Numerical Analysis of Thermal Flow in Solar Lamp Bank (솔라 램프뱅크 내의 열유동 수치해석에 관한 연구)

  • Kim, Sung-Dae;Ryoo, Seong-Ryoul;Baek, Sang-Hwa;Lee, Jeong-Yong;Park, So-Jin;Kim, Chul-Ju;Ko, Han-Seo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.136-143
    • /
    • 2008
  • A three-wavelength solar bank is a very important part for a solar simulator with commercial superlux lamps. It is projected metal halide lamps to satisfy following points simultaneously: $\pm$10% of uniformity for irradiance of target area and irradiance in each wave region, and $1,232W/m^2$ of maximum solar irradiance in summer. The developed solar lamp bank has been analyzed numerically by commercial programs in this study to carry out experiments. In conclusion, designed B-type heat lamp is not concentrated in one place than designed A-type heat lamp, it is spreaded widely, and it was proved numerical computation. We suggest that solar simulator is applied to actual experiment test through heat flow numerical analysis in solar lamp bank and the lamp is applied private industry or the military using complex environmental assessment test.

Nano-Powder 제조를 위한 RF Thermal Plasma Torch System 개발 및 Nano-Si 특성 연구

  • Song, Seok-Gyun;Son, Byeong-Gu;Kim, Byeong-Hun;Lee, Mun-Won;Sin, Myeong-Seon;Choe, Seon-Yong;Kim, Seong-In
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.179-179
    • /
    • 2012
  • 국내에는 나노 분말 제조를 위한 RF 열플라즈마 시스템 제조 기술이 확보되어 있지 않고, 또한 나노 파우더 제조를 위한 공정 기술 역시 외국 업체에 전적으로 의존하고 있다. 본 연구에서는 나노 분말 제조를 위한 RF 열 플라즈마 토치 시스템 개발과 고품질의 나노 파우더 합성 공정 기술을 확립하여 필요 기관에 제공하는데 있다. 80 kW RF Plasma torch system의 설계 및 제작을 위해 플라즈마 Simulator인 CFD-ACE+를 이용하여 플라즈마 토치 및 반응로 내의 온도 분포, 유체 유동, 열전달 등의 해석을 통해 플라즈마 토치 및 반응로의 반경 및 길이, 구조의 설계 값을 도출하여 반응로를 설계하여 RF 파워, RF 플라즈마 토치(Torch), 반응기(Reactor), 사이클론(Cyclone), 포집부(Collector), 열교환기 및 진공배기 시스템으로 구성하였다. Si 나노 소재의 경우, 이차전지 음극재에 적용이 가능한 대표적인 소재로서 높음 비용량과 충/방전시 부피팽창을 감소시킬 수 있어 이차전지의 고용량 구현을 위해서는 가장 중요한 소재중 하나로 많은 관심 재료로 평가 받고 있다. 따라서 본 연구에서는 상용화된 Si 원료 powder를 사용하여 고상 분체 공급 장치를 통하여 고온의 플라즈마를 통과시켜 기상화 및 결정화과정을 통해 Si 나노분말을 제조하였다. 공정 변수로서 공정압력 및 플라즈마 power, Gas의 변화량에 따른 나노 분말의 제조 특성에 대한 실험을 진행한 후 제조된 나노 분말을 비표면적측정(BET) 및 SEM 측정 결과 분석을 통하여 시스템 특성을 파악하였으며 제조된 Si 나노 파우더는 이차전지 음극재로서 770 mAh/g의 용량과 93%@50 cycle 수준의 유지율을 나타내었다.

  • PDF

Numerical Investigation of the Spray Behavior and Flow Characteristics of Urea-Water Solution Injected into Diesel Exhaust Pipe (디젤 배기관에 분사된 우레아 수용액의 분무 거동 및 유동 특성에 관한 연구)

  • An, Tae Hyun;Kim, Man Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.41-48
    • /
    • 2014
  • A urea-SCR system suffers from some issues associated with the ammonia slip phenomenon, which mainly occurs because of the shortage of evaporation and thermolysis time, and this makes it difficult to achieve an uniform distribution of injected urea. A numerical study was therefore performed by changing such various parameters as installed injector angle and application and angle of mixer to enhance evaporation and the mixing of urea water solution with exhaust gases. As a result, various parameters were found to affect the evaporation and mixing characteristics between exhaust gas and urea water solution, and their optimization is required. Finally, useful guidelines were suggested to achieve the optimum design of a urea-SCR injection system for improving the DeNOx performance and reducing ammonia slip.

Theoretical Analysis of Heat Pipe Thermal Performance According to Nanofluid Properties (나노유체 특성에 따른 히트파이프 성능해석)

  • Lim, Seung Min
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.599-607
    • /
    • 2015
  • In this study, we theoretically investigate the thermal performances of heat pipes that have different nano-fluid properties. Two different types of nano-particles have been used: $Al_2O_3$ and CuO. The thermal performances of the heat pipes are observed for varying nano-particle aggregations and volume fractions. Both the viscosity and the conductivity increase as the volume fraction and the aggregation increase, respectively. Increasing the volume fraction helps increase the capillary limit in the well-dispersed condition. Whereas, the capillary limit is decreased under the aggregate condition, when the volume fraction increases. The dependence of the heat pipe thermal resistance on the volume fraction, aggregation, and conductivity of the nano-particles is analyzed. The maximum thermal transfer of the heat pipe is highly dependent on the volume fraction because of the high permeability of the heat pipe. For the proposed heat pipe, the optimum volume fraction of the nano-particle can be seen through 3D graphics.

Basic Study on Diffusion Branch of Tribrachial Flame with the Variation of Flammability Limits and Heat Loss Under Small Fuel Concentration Gradient (미소 농도구배 조건에서 열손실 및 가연한계가 삼지화염의 확산화염에 미치는 영향에 대한 기초 연구)

  • Cho, Sang-Moon;Lee, Min-Jung;Kim, Nam-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.5
    • /
    • pp.505-513
    • /
    • 2010
  • The tribrachial flame has attracted interest as a basic structure of the flame edge. This flame structure helps understand stabilization of laminar flames and re-ignition of turbulent flames. A number of analytical and experimental studies have been carried out on the tribrachial flame. However, the effect of the variation of the flammability limits on the structure of the tribrachial flame has not been studied in detail. In this study, the effect of non-symmetric flammability limits on the flame structure was investigated by adopting a simple numerical scheme based on several laminar flame theories. A fixed velocity field was considered and boundary matching algorithm was used on the premixed branch. The variation of the diffusion branches under the non-symmetric flammability limits and heat loss was investigated. The formation and extinction of the diffusion branch behind the premixed branch were successfully described. This basic study can help understand the fundamental structure of the flame and can form the basis of subsequent detailed studies.

Improvement of Fire Detection in Rack-type Warehouses using FDS (FDS를 이용한 랙크식 창고의 화재감지 개선에 관한 연구)

  • Choi, Ki-Ok;Park, Moon-Woo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.55-60
    • /
    • 2019
  • The occurrence of fire in rack-type warehouses may either lead to the warehouses getting entirely burned up or collapsing. This can be attrubuted to the high height of rack-type warehouses, in which combustibles are generally vertically stacked. These characteristics make it difficult to detect a fire early; because detectors are installed on the ceiling, these fires cannot be extinguished at an early stage. In this study, the flow of heat and smoke generated by a fire in a rack-type warehouse was analyzed using a fire dynamic simulator. Through this analysis, the optimal installation conditions of fire detectors for the early detection of fire in rack-type warehouses were confirmed. The analysis results confirmed that complex detection of heat and smoke is required for the early detection of fire in rack type warehouses. Furthermore, it was found that fixed temperature detectors are not suitable for these warehouses, resulting in the need to install heat-smoke hybrid detectors at every three rack levels.