• Title/Summary/Keyword: 열 화원

Search Result 46, Processing Time 0.02 seconds

Experimental Study on Interaction of Water Sprayed Curtain on Hot Surface of a Window Glass and its Effects on Glass Surface Temperature in Room Fires (구획화재 시 국부복사열에 노출된 유리면의 수막접촉에 따른 급냉파열특성 관한 실험적 연구)

  • 박형주;지남용
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.124-130
    • /
    • 2003
  • This research focuses on analysis of a interaction fracture of various glasses due to contact of water sprayed curtain on hot glass surface with high temperature produced from convective heat source near glass wall. A large scaled experimental test was done in order to find the range of the glass surface temperature to be able to cause the breakage of the glasses when water droplets reach on the hot surface. This paper shows the allowable temperature of the glass surface for prevention of the cooling down breakage before water curtain droplets contact the surface. Allowable Temperature if $250^{\circ}C$ for the tempered glass but general glass is very relatively low. Therefore if the water curtain spray system was adequately activated by a thermal detector installed below ceiling adjacent glass wall with water curtain nozzle system, all hot glass would not break out by cooling water droplet's contact on the hot surface due to convective heat released by adjacent fire source near the glass wall.

Simulation & Validation of Lubricating Oil Fire in Nuclear Power Plant Pump Room (원전 펌프실 윤활유화재 분석 및 확인에 관한 연구)

  • Park, Jong-Seuk;Park, Yoon-Jeong;Lee, Chang-Joo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.241-245
    • /
    • 2010
  • 화재방호에 성능기반 개념을 도입함에 따라 화재모델링의 활용도는 점점 높아지고 있다. 본 연구의 목적은 FDS를 이용하여 원자력발전소 펌프실의 윤활유 화재 시 케이블의 손상여부를 평가하고, 확인분석을 통해 화재모델링의 적합성을 파악하는 데 있다. 화재는 펌프 주변의 누출된 윤활유에서 발생하며 화원의 면적은 $2.75m^2$이고 단위면적당 열방출율은 $1,794kW/m^2$로 가정하였다. 계산결과, 고온기체층의 온도는 $400^{\circ}C$를 상회하고 있으나 케이블 트레이의 온도는 $50^{\circ}C$ 아래로 예측되고 있어 본 화재시나리오에서 케이블의 건전성은 유지되고 있으며 밀폐된 격실에서의 대형화재는 환기지배형 화재가 된다는 것을 보여주고 있다. 또한 확인분석 결과, 화재 시나리오의 주요 변수인 열방출율, 격실크기 그리고 강제 환기 변수가 확인계산 범위 내에 있어 본 계산결과는 NUREG-1824의 확인요건을 만족하고 있다. 따라서 펌프실 윤활유 화재에 대한 모델링의 적합성을 확인하였다.

  • PDF

Compartment Fire Test Using Kerosene and Aviation Fuel (등유 및 항공유를 사용한 격실 화재시험)

  • Bang, Kyoung-Sik;Lee, Ju-Chan;Seo, Chung-Seok;Seo, Ki-Seog;Kim, Hyung-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.476-479
    • /
    • 2012
  • 차량의 충돌에 따른 등유의 누출에 의한 화재와 항공기 충돌에 따른 항공유의 누출에 의한 화재 발생 시 격실의 개구부 크기에 따른 화염온도를 평가하기 위해 화원으로 등유와 Jet-A-1을 사용하고 개구부의 크기를 조절해 가며 격실화재시험을 수행하였으며, 가장 높게 측정된 시험결과의 조건으로 과도화재시험을 수행하여 금속저장용기가 화염온도에 미치는 영향을 평가하였다. 시험결과 등유보다 Jet-A-1의 열 방출속도 및 질량 연소유속이 크게 나타났으며, Jet-A-1에서의 화염온도가 높게 측정되었다. 연료 소모율은 개구부의 크기가 클 경우 작은 경우보다 크게 나타났으며, 개구부의 크기가 클 경우 화염온도가 높게 측정되었다. 격실 내에 금속저장용기가 저장되었을 때는 저장용기가 화염으로부터 받는 열량만큼 화염의 온도는 낮아지는 것으로 나타났다.

  • PDF

Flame Spread Calculation in BRANZFIRE Model (BRANZFIRE 모델에서 Flame Spread 적용성 검토)

  • Park, Kye-Won;Jeong, Jae-Gun;Kim, Woon-Hyung;Kim, Jong-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.77-78
    • /
    • 2013
  • BRANZFIRE 모델은 가연성 내장재의 화재위험성을 평가하는 존모델이다. 내장재의 화염확산에 따른 화재성장모델을 공간화재에 적용하는 다실형 존모델로서 특히 ISO 9705 시험화재 시나리오 적용에 매우 유용하다. 본 연구에서는 화재성장모델에서의 화원 및 공간특성 따른 열방출비율과 화염확산 예측 인자의 영향성을 분석하였다

  • PDF

A Study on the Application of Ventilation Equipment in an Underground Fire (지하공간 화재시 배연장비의 활용에 관한 연구)

  • Lee, Sung-Ryong;Han, Dong-Hoon
    • Tunnel and Underground Space
    • /
    • v.20 no.2
    • /
    • pp.92-96
    • /
    • 2010
  • In this study, experiments were conducted to evaluate the effectiveness of ventilation equipment in underground fires. Two type of Ventilators were used in experiments. Experiments were carried out using ethanol square pool fire. Maximum heat release rate was about 460kW. Visibility and temperature distribution were evaluated according to mechanical ventilation. In blower type ventilation, visibility was increased and temperature was lowered.

Fire Test of Old Type Interiors of Subway Vehicle in ISO 9705 Room (ISO 9708 룸 설비를 이용한 구형 지하철 내장재 화재시험)

  • Lee, Duck-Hee;Park, Won-Hee;Jung, Woo-Sung;Hwang, Jung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.481-487
    • /
    • 2010
  • A room scale fire test was done for interior materials from a subway vehicle installed within an ISO 9705 fire test room. The interior materials are the old ones which were made before the new fire safety guideline of subway vehicles. The output of ignition burner was increased in controlled steps to CEN/TS 45545-1. The objectives of this interior fire test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving subway vehicle interior materials that grow to flashover. Temperatures, heat flux and heat release rate variations verse time of the test are measured. Heat release rate is compared with that of calculated by modified flaming area based summation method. These test results will be used for verification of CFD fire simulation of full subway vehicle.

An analytical study on the fire characteristics of the small tunnel with large smoke exhaust port (대배기구 배연방식을 적용한 소형차 전용 터널의 화재특성에 관한 해석적 연구)

  • Yoo, Ji-Oh;Kim, Jin-Su;Rhee, Kwan-Seok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.375-388
    • /
    • 2017
  • In order to solve the traffic congest and environmental issues, small-cross section tunnel for small car only is increasing, but there is not standard for installation of disaster prevention facility. In this study, in order to investigate the behavioral characteristics of thermal environment and smoke in a small cross section tunnels with a large port exhaust ventilation system, the A86, the U-Smartway and the Seobu moterawy tunnel, Temperature and CO concentration in case of fire according to cross sectional area, heat release rate and exhaust air flow rate were analyzed by numerical analysis and the results were as follows. As the cross-sectional area of the tunnel decreases, the temperature of the fire zone increases and the rate of temperature rise is not significantly affected by heat release rate. However, there is a difference depending on the change of the exhaust air flow rate. In the case of applying the exhaust air flow rate $Q_3+2.5Ar$ of the large port exhaust ventilation system, the temperature of the fire zone was 7.1 times for A86 ($Ar=25.3m^2$) and 5.4 time for U-smartway ($Ar=37.32m^2$) by Seobu moterway tunnel ($Ar=46.67m^2$). The CO concentration of fire zone also showed the same tendency. The A86 tunnels were 10.7 times and the U-Smartways were 9.5 times more than the Seobu moterway. Therefore, in the case of a small section tunnel, the thermal environment and noxious gas concentration due to the reduction of the cross-sectional area are expected to increase significantly more than the cross-sectional reduction rate.

ISO 9705 Room-Corner Test & Model simulations (ISO 9705 Room-Corner Test와 모델 평가)

  • ;S.E. Dillom;J,G Quintiere
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.3-11
    • /
    • 1999
  • New examination of a predictive model for the ISO 9705 room-corner test have been m made for materials studied by L S Fire Laboratories, Italy. The ISO 9705 test subjects wall a and ceiling mounted materials to a comer ignition source of 100 kW for a duration of 10 m minutes; if flashover does not occur this is followed by 300 kW for another 10 minutes. The m materials that did not stay in place during combustion because of melting, dripping, or d distorting were simulated by an adjustment to the material's total available energy. For m mat려als that remain in place the simulation model appears to do well in its prl어ictions. A l large-s떠Ie room test results 뾰 compar벼 with the m여el’s prediction also.

  • PDF

A Fire Test Measuring the Heat Release Rate of Railway Car Interior Materials Satisfying the Korean Safety Guideline (안전기준을 만족하는 철도차량 내장재의 화재 열방출율 측정시험)

  • Park, Won-Hee;Lee, Duck-Hee;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.40-49
    • /
    • 2009
  • A large-scale fire test was conducted for interior materials from a vehicle installed within a fire test room (ISO 9705). The interior materials are satisfying the Korean guideline for the safety of rail vehicles, where the guideline has taken effect since December 2004 in Korea. The output of ignition source (gas burner) was increased in several controlled steps. The objectives of this test are to assess the fire performance in terms of ignition and flame spread on interior lining materials and to provide data on an enclosure fires involving train interior materials that grow to flashover. These data will be used to develop and calibrate models for fire growth on the interiors of the railway vehicle.

A Experimental Study on the Response Characteristics for Fire Detector by Combustibles (가연물에 따른 화재감지기 응답특성에 관한 실험연구)

  • Choi, Moon-Soo;Hong, Sung-Ho;Lee, Sang-Ho;Park, Sang-Tae;Yoo, Song-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.514-517
    • /
    • 2011
  • 화재감지 및 경보시스템의 설계 목표는 화재발생 초기 단계에서 화재징후를 발견, 피난의 개시를 신속하게 통수하는 것이다. 화재감지기는 다양한 건물 및 환경에 설치되기 때문에 주위 온도 및 가연물의 종류 등 환경적 측면을 심층적으로 고려하지 않으면 적절하게 감지하지 못하는 경우가 발생할 수 있다. 즉, 가연물 종류 등을 고려한 설계에 따라 설치된 화재감지기는 화재시 설계치 대로 조기에 화재를 감지하여 화재 예방 및 화재로 인한 피해를 최소화할 수 있는 것이다. 본 논문은 화재시 조기에 화재를 감지기하여 건축물내 인명피난을 목적으로 설치되는 화재감지기의 응답특성을 분석한 연구이다. 화재감지기의 응답특성을 분석하기 위하여 다양한 가연물을 발생시키고 화재감지기 종류별로 설치한 다음 각 화재감지기의 응답특성을 분석하였다. 그 결과 정온식 열감지기는 열방출률이 적은 화재를 조기에 감지하는 것에 적합하지 않은 것으로 나타났다. 광전식 연기감지기는 회색 계통의 목재류 화재성상에서 응답특성이 떨어졌고, 동일한 공간에서 화원의 수평거리와 동작시간이 비례한다고 볼 수 없었다.

  • PDF