• Title/Summary/Keyword: 열 전달계수

Search Result 248, Processing Time 0.025 seconds

A Study on Condensation Heat Transfer in Air Pre-heating Heat Exchanger using Hydrophilic Surface (친수성 표면 처리를 통한 공기 예열 열교환기의 응축 열전달 성능 연구)

  • Park, Jae Won;Hwang, Sueng Sik;Seok, Sung Chul;Shin, Dong Hoon;Chung, Tae Yong;Son, Sueng Gil
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.191-197
    • /
    • 2014
  • To increase the heat transfer rate of the air pre-heating heat exchanger used for the condensing boiler, We investigated condensation heat transfer coefficients through plasma surface treatment. The hydrophilic surface showed about 10% increase in heat transfer rate than original plate. It shows that Shah correlation can be used to predict the condensation heat transfer coefficient on the original surface within 10% error range after the compatison between Shah correlation and the condensation heat transfer coefficients measured on the hydrophilic surface and original surface. Therefore, we have shown that Shah correlation is available when designing the air pre-heating heat exchanger using the original surface in this study.

External Condensation Heat Transfer Coefficients of HFC32/HFC152a Mixtures on Enhanced Tubes (열전달 촉진관에서 HFC32/HFC152a 혼합냉매의 외부 응축열전달계수)

  • Lee, Yohan;Kang, Donggyu;Kim, Hyeon-Ju;Lee, Ho-Saeng;Jung, Dongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.315-321
    • /
    • 2014
  • In this study, external condensation heat transfer coefficients (HTCs) of two non-azeotropic refrigerant mixtures of HFC32/HFC152a at various compositions were measured on both 26 fpi low-fin and Turbo-C enhanced tubes, of 19.0 mm outside diameter. All data were taken at the vapor temperature of $39^{\circ}C$, with a wall subcooling of 3~8 K. Test results showed that the HTCs of the tested mixtures on the enhanced tubes were much lower than the ideal values calculated by mass fraction weighting of the pure component HTCs. Also, the reduction of HTCs due to the diffusion vapor film was much larger than that of a plain tube. Unlike HTCs of pure fluids, HTCs of the mixtures measured on enhanced tubes increased, as the wall subcooling increased, which was due to the sudden break-up of the vapor diffusion film with an increase in wall subcooling. Finally, the heat transfer enhancement ratios for mixtures were found to be much lower, than those of pure fluids.

STUDY ON VIEW FACTOR CALCULATION FOR RADIATIVE HEAT TRANSFER BY USING THE MESH SUBDIVISION METHOD (격자 세분화 방법을 고려한 복사열전달 형상계수 계산 기법 연구)

  • Kim, D.G.;Han, K.I.;Choi, J.H.;Lee, J.J.;Kim, T.K.
    • Journal of computational fluids engineering
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Since experiments on the actual operational status are said to be very impractical because of their economic and repeatability problems, it is difficult to understand the thermal profiles of aerospace or military equipments. Thus, the CFD codes with considering the radiation heat transfer are used to compensate the defect. In case, analyzing the radiation exchanges between the object surfaces are very important. Because the temperature and the IR signal distributions of the object surface are significantly affected by the radiative heat transfer. To achieve accurate thermal radiation exchange between surfaces, it is important to calculate the radiation view factor precisely. Finer subdivision of meshes can be used to increase the accuracy of radiation view factor, but if the mesh is subdivided infinitely, the time required for calculation increases significantly and thus decreasing the efficiency. If the subdivision is not sufficient, assurance of accuracy is not guaranteed. In this paper, optimal mesh subdivision method using the solid angle has been successfully tested and found to be useful in increasing the efficiency of calculating the shape factors.

The Condensation Heat Transfer of Alternative Refrigerants for R-22 in Small Diameter Tubes (세관내 R-22 대체냉매의 응축열전달에 관한 연구)

  • Son, Chang-Hyo;Jeong, Jin-Ho;O, Jong-Taek;O, Hu-Gyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.2
    • /
    • pp.180-186
    • /
    • 2001
  • The condensation heat transfer coefficients of pure refrigerants R-22, R-134a, and a binary refrigerant mixture R-410A flowing in a small diameter tube were investigated. The experiment apparatus consists of a refrigerant loop and a water loop. The main components of the refrigerant loop consist of a variable-speed pump, a mass flowmeter, an evaporator, and a condenser(test section). The water loop consists of a variable-speed pump, an isothermal tank, and a flowmeter. The condenser is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. The test section consists of smooth, horizontal copper tube of 3.38mm outer diameter and 1.77mm inner diameter. The length of test section is 1220mm. The refrigerant mass fluxes varied from 450 to 1050kg/(㎡$.$s) and the average inlet and outlet qualities were 0.05 and 0.95, respectively. The main results were summarized as follows ; in the case of single-phase flow, the heat transfer coefficients increase with increasing mass flux. The heat transfer coefficient of R-410A was higher than that of R-22 and R-134a, and the heat transfer for small diameter tubes were about 20% to 27% higher than those predicted by Gnielinski. In the case of two-phase flow, the heat transfer coefficients also increase with increasing mass flux and quality. The condensation heat transfer coefficient of R-410A was slightly higher than that of R-22 and R-134a. Most of correlations proposed in the large diameter tube showed significant deviations with experimental data except for the ranges of low quality and low mass flux.

Heat transfer characteristics with materials of the filler and flow path in vehicle washer heater system (차량워셔액 가열시스템에서 충전재 및 유로의 재질에 따른 열전달 특성 연구)

  • Cha, Woo Sub;Kim, Tae Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2628-2634
    • /
    • 2014
  • Vehicle washer heater system is more widely adopted to defrost a window or to clear the windshield glass in winter season. The washer heater system should be designed to heat up washer fluid rapidly to the target temperature for only a short time. A numerical analysis has been carried out to analyze the heat transfer characteristics with materials of inside parts in vehicle washer heater system with filler and flow path. ANSYS - FLUENT software is employed for the analysis. The axial symmetry model is three-dimensional and unsteady. It applies to the coupled method which is one of pressure based. Through this result, it was obtained to find the optimal material condition for the filler and flow path in washer system. For material of filler, the air with lower density was heated more rapidly rather than silicon carbide(SiC). For material of flow path, copper with the heat transfer coefficient of approximately four times greater than the nickel gives us higher efficiency. That is the reason why the heating time of methanol was reduced to make uniform temperature in washer heater system.

Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel (수평미세관내 R-290의 비등열전달 특성)

  • Choi, Kwang-Il;Pamitran, A.S.;Oh, Jong-Taek
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

Photoacoustic Nonlinearity to Absorption Coefficients in Photoacoustic Imaging with Focused Ultrasound Transducers (초점 초음파 측정기로 측정한 광음향 신호의 광 흡수계수에 대한 비선형성)

  • Kang, Dongyel
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.158-165
    • /
    • 2017
  • The physical shape of an ultrasound transducer has not been considered in previous studies of the photoacoustic saturation effect, where a photoacoustic signal's magnitude linearly increases as an absorption coefficient increases and it is finally saturated. In this paper, the effect of a spherically focused ultrasound transducer on photoacoustic nonlinearity is investigated. The focused ultrasound transducer's spatial filtering effect on photoacoustic signals is analytically derived considering the combined concept of a virtual point detector and Green function approach. The ultrasound transducer's temporal response (i.e., transfer function) effect on photoacoustic signals is considered by integrating photoacoustic signal values within the absorption area covered by a spatial resolution of the ultrasound transducer. Results from the analytically derived expression show that the magnitude of photoacoustic signals measured by a spherical focused ultrasound transducer shows a maximum at a specific absorption coefficient, and decreases after that maximum point as an absorption coefficient is increased. The origin of this photoacoustic nonlinearity is physically understood by comparing the ultrasound transducer's transfer functions and photoacoustic resonance spectra. In addition, this physical interpretation implies that the photoacoustic nonlinearity is strongly dependent on the irradiance distribution inside an absorption medium.

Research on the Performance of Total Heat Exchanger in a Solar Air-Conditioning System (태양열 이용 냉난방 공조시스템 중 전열교환기 성능에 관한 연구)

  • Kim, K.H.;Choi, K.H.;Kum, J.S.;Kim, B.C.;Kim, J.R.
    • Solar Energy
    • /
    • v.19 no.4
    • /
    • pp.45-53
    • /
    • 1999
  • This report Introduces a total heat exchanger in a solar air-conditioning system using Lithium Chloride(LiCl) solution. The hot and humid outside air is cooled and dehumidified by LiCl solution that is sprayed on the packed layer of the total heat exchanger. LiCl solution once diluted is concentrated again in a regenerator using solar energy. Three types as the packed materials were used in this experiment and the dehumidification performance was evaluated by the value of $k_xa(kg/h{\cdot}m^3{\cdot}{\Delta}x)$, overall mass transfer coefficient based on a humidity ratio potential difference, the influence of inlet LiCl solution flow rate, air flow rate, packed layer height on $k_xa$ was investigated. It was found that air flow rate, LiCl solution flow rate, packed layer height for all types had a great influnce on the value of $k_xa$.

  • PDF

Comparative Study of Near-Wall Treatment Methods for Prediction of Heat Transfer over Gas Turbine Nozzle Guide Vane (가스터빈 노즐 베인의 열전달 예측을 위한 벽면처리법 비교연구)

  • Bak, Jeonggyu;Kim, Jinuk;Lee, Seawook;Gang, Youngseok;Cho, Leesang;Cho, Jinsoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.639-646
    • /
    • 2014
  • The comparative analysis of near-wall treatment methods that affect the prediction of heat transfer over the gas turbine nozzle guide vane were presented. To achieve this objective, wall-function and low Reynolds number methods, and the transition model were applied and simulated using NASA's C3X turbine vane. The predicted turbine vane surface pressure distribution data using the near-wall treatment methods were found to be in close agreement with experimental data. However, the predicted vane metal temperature and heat transfer coefficient displayed significant differences. Overall, the low Reynolds method and transition model did not offer specific advantages in the prediction of temperature and heat transfer than did the wall-function method. The Reynolds stress model used along with the wall-function method resulted in a relatively high accuracy of prediction of the vane metal temperature and heat transfer coefficient.

광미/광폐석 처리를 위한 고형화 공정 실증 실험

  • Jeon Ji-Hye;Choi Ae-Jeong;Kim In-Su;Lee Min-Hui;Jang Yun-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.166-170
    • /
    • 2006
  • 본 연구에서는 폐광산 주변에 산재되어 있는 광미/광폐석을 처리하기 위하여 고형화 실증 실험을 수행하였다. 고형화 공정에서 흔히 사용하는 포틀랜드 시멘트와 MSG-E, MSG-N을 고화제로 사용하였으며 현장 광미 및 광폐석을 대상으로 고화체를 양생하고 고화체의 압축강도 및 중금속 용출 정도를 측정하였다. 고화체의 물리/화학적 특성을 비교하기 위해 광미/고화제 비율, 배합수/고화제 비율 그리고 고화체 양생기간을 실험인자로 설정하였다. 실험 결과 광미/고화제의 비율 1:1 만을 고려하더라도 중금속 용출의 급격한 감소가 이루어지는 것을 확인할 수 있었으며 광미/고화제의 비율을 3:1 이하로 유지시키는 경우, 고화체의 압축강도가 현행 폐기물 관리법(20조 관련)에서 규정하고 있는 차단형 매립시설 내부막의 압축강도 기준인 $0.21kgf/mm^2$ 보다 높은 것으로 나타났다. 다양한 pH를 갖는 수용액에 대하여 시간에 따른 고화체의 중금속 용출률을 측정한 결과, 수용액의 pH가 1과 13인 강산/강염기 용액에서 일부 중금속의 용출 농도가 지하수 생활용수 기준치를 초과하였으나, pH와 3 - 11인 경우에는 중금속 용출률이 급격히 감소하여 모두 기준치 이하를 나타내었다. 또한, pH가 1과 13인 수용액의 경우에도 고화체와 반응하는 시간이 증가할수록 고화체의 buffering 효과에 의해 수용액의 pH가 감소하였다. 이러한 결과는 현장에서 접촉수의 pH가 강산이나 강염기라 하여도, 고화체의 buffering 효과에 의해 시간이 지남에 따라 수용액의 pH가 낮아져 고화체로부터의 중금속 용출은 매우 감소할 것임을 의미한다.ss of an active application defined using the model. The technique is developed in a platform- and language-independent way, and it is algorithmic and can be automated by computer program. We give an example dealing with network auction to illustrate the use of the model and the verification technique.품으로 내부 온도분포를 측정하였으며, 유한차분법 프로그램으로 대류열전달계수를 결정하였다. 대류열전달계수는 792에서 2,107 W/m$^2$로 분석되었다. 대류열전달 계수는 액상식품과의 상대속도가 증가함에 따라서 증가하였고, 점도가 증가함에 따라서는 감소하였다.ce of precision/recall of 90.99%/92.52%, and 93.39%/93.41% respectively. 의한 변성에 부분적으로 보호 작용을 나타 낼 것으로 추정된다.경(製麴72時間頃)의 활성(活性)은 보리쌀국(麴), 밀가루국(麴), 찹쌀국(麴), 고구마국(麴)의 순이었다.험 결과 오전용 사료는 관행적인 산란계 배합사료에서 Ca공급제를 제외한 것을 급여하고, 오후용 사료는 Ca공급제를 3배 첨가한 T2처리로 15:00~16:00시에 교체급여를 하면 사료섭취량 감소와 사료비 절감면에서 바람직할 것으로 사료되며, 고에너지-고단백질-저Ca의 분말사료와 저에너지-저단백질-고Ca의 펠렛사료를 혼합급여하면 산란계의 사료

  • PDF