• Title/Summary/Keyword: 열 유속 특성

Search Result 282, Processing Time 0.026 seconds

Long Term Monitoring of Dynamic Characteristics of a Jacket-Type Offshore Structure Using Dynamic Tilt Responses and Tidal Effects on Modal Properties (동적 경사 응답을 이용한 재킷식 해양구조물의 장기 동특성 모니터링 및 조류 영향 분석)

  • Yi, Jin-Hak;Park, Jin-Soon;Han, Sang-Hun;Lee, Kwang-Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2A
    • /
    • pp.97-108
    • /
    • 2012
  • Dynamic responses were measured using long-term monitoring system for Uldolmok tidal current pilot power plant which is one of jacket-type offshore structures. Among the dynamic quantities, the tilt angle was chosen because the low frequency response components can be precisely measured by dynamic tiltmeter, and the natural frequencies and modal damping ratio were successfully identified using proposed LS-FDD (least squared frequency domain decomposition) method. And the effects of tidal height and tidal current velocity on the variation of natural frequencies and modal damping ratios were investigated in time and frequency domain. Also the non-parametric models were tested to model the relationship between tidal conditions and modal properties such as natural frequencies and damping ratios.

Recent Developments in High-Flux Heat Transfer Tubes (最近의 高性能傳熱管의 開發)

  • 서정윤
    • Journal of the KSME
    • /
    • v.18 no.3
    • /
    • pp.18-24
    • /
    • 1978
  • 열고환기에는 boiler와 같이 다량의 열 energy를 취급하는 것을 비롯하여 가정용 냉장고, 냉방기 기와 같이 비교적 적은 양의 열 energy를 취급하는것, 가종 고온 gas-gas 열교환기, 초전도송전 등의 초저온기기에 부속되는 저온열교환기 혹은 배열회수, 태양열이용을 위한 장치에 포함되는 열교환기등이 있으며, 그 종류와 내용에 있어서 다양하다. 따라서 새 형식의 열교환기 혹은 우수 한 전열특성을 갖는 표면, 형상을 갖는 전열관의 연구, 개발은 한층더 절실하게 요망된다. 최근주 목을 받고 있는 열교환기용전열관중에는 관축방향을 따라 표면을 파상으로 가공한 것(corrugate 식)과 축과 평형이 되게 만든 좁은 흠을 갖는 관(fluted tube)등이 있는데 이들에 있어서는 다같 이 표면의 요철에 의한 면부근의 난동을 촉진시켜서 우수한 대류열전달의 특성을 갖도록 하고 있다. 한편 응축과 비등등의 상변화를 동반하는 열전달에 대해서는 세구, 기공질금속층, 세공등을 갖는 면에 관해서 새로운 관심이 집중되고 있다. 이 후자의 전열면은 유축열전달에서는 평활면보 다 약10배의 높은 열전달율을 가지며 불등열전달에서는 벽면과 액의 온도차는 평활면의 경우보다 약1/5의 값을 갖는다. 동시에 한계열유속은 5활이상으로 증가시킬 수 있음이 알려져 있다. 따라서 본론에서는 후자의 전열면중에서 최근에 알려진 비약적으로 높은 전열성능을 갖는 전열면에 관해 서 소개하기로 한다.

  • PDF

A Study on analysis between pressure-drop and cavitation diminution with ball valve (볼 밸브 압력강하와 공동현상감소에 대한 연구)

  • Gu, Bon-Chan;Gi, Jun-U;Lee, Do-Hyeong
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.393-397
    • /
    • 2013
  • 관내의 유량을 제어하는 볼 밸브(ball valve)는 개폐각도(opening degree)가 커짐에 따라 출구에서 유속이 증가하고 밸브(valve)의 입 출구 간 압력강하(pressure drop)가 증가한다. 출구에서의 압력이 작동유체의 포화증기압보다 낮아질 때 공동현상(cavitation)이 발생한다. 관내에서의 공동현상은 배관시스템의 진동 및 소음, 부식 등에 있어서 악영향을 미칠 수 있으므로 설계에 매우 중요한 요소이다. 버터플라이 밸브를 비롯한 다른 밸브에서는 공동현상감소에 대한 연구가 많이 이루어졌다. 이에 본 연구에서는 볼 밸브 내 유동 특성(characteristic of flow)과 볼 밸브의 입출구간 압력강하를 줄이는 연구를 수행하였다. 개폐 각도와 그에 따른 압력강하와의 관계를 Edison_전산열유체를 사용하여 분석하고 공동현상을 감소시킨 볼 밸브의 설계를 제시 하였다.

  • PDF

A Combustion Characteristic Analysis of Quercus Variabilis and Pinus Densiflora Fallen Leaves Using Radiation Heat Flux (복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석)

  • Park, Hyung-Ju;Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • The combustion characteristics of surface forest fire fuels was analysed using variable external irradiation level. The characteristics such as ignition time, ignition temperature, critical heat flux and mass loss rate were measured. Fuel samples were exposed to incident heat fluxes from 8 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen holder was $100\;mm{\times}100\;mm{\times}12\;mm$ and the fuel samples grinded by electric mill were the fallen leaves of Quercus variabilis and Pinus densiflora. As results, the occurrence of ignition is possible to the heat flux more than $9\;kW/m^2$. The fuel of Pinus densiflora keeps its high temperature longer than that of Quercus variabilis during the combustion process. The results of measurement shows that the maximun and average mass loss rate of Quercus variabilis larger than that of Pinus densiflora.

Multi-dimensional Fire Behaviors in an Under-ventilated Compartment Fire (환기부족 구획화재에서 다차원 화재거동)

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.37-42
    • /
    • 2010
  • 실제 규모 ISO 9705 표준 화재실에서 과환기(over-ventilated) 및 환기부족(under-ventilated) 화재에 대한 열 및 화학적 특성에 관한 실험이 수행되었다. 또한 FDS(Fire Dynamic Simulator)를 이용하여 수치적 예측성능에 대한 평가와 환기부족화재에서 건물 내부의 다차원 화재현상에 대한 해석이 이루어졌다. 과환기 및 환기부족화재의 특성은 연소효율, 총괄 당량비 뿐만 아니라 고온 상층부의 온도분포, 연소 생성물의 농도에 의해 명확하게 구분되었다. 실험결과와의 비교를 통해 과환기 및 환기부족화재에서 FDS는 공간내부의 온도, 열유속 및 다양한 화학종의 분포를 정량적으로 잘 예측함을 확인하였다. 과환기화재와 비교할 때, 환기부족화재에서 내부유동은 반대방향의 다차원 재순환 유동구조를 갖고 있음을 발견하였다. 동시에 공간내부의 $O_2$ 및 CO의 분포 역시 다차원 구조를 갖기 때문에 기존화재연구에서 측정되는 고온 상층부의 열 및 화학적 특성은 환기부족화재를 이해하는데 많은 한계가 있음을 확인하였다.

  • PDF

Experimental and Numerical Studies on Heat/Smoke Behavior due to a Fire on Underground Subway Platform (II) - Numerical Approach - (지하철 역사 승강장 화재발생시 열/연기 거동 분석을 위한 실험 및 수치 연구(II) - 수치적 접근 -)

  • Chang, Hee-Chul;Kim, Tae-Kuk;Park, Won-Hee;Kim, Dong-Hyeon
    • Fire Science and Engineering
    • /
    • v.20 no.3 s.63
    • /
    • pp.15-20
    • /
    • 2006
  • In this study the flow characteristics of smoke and heat on a bank type platform of the underground subway station are studied numerically by considering two different emergency operation modes. Effects of the natural flow through the tunnel and the stair ways are considered in the numerical simulations by using the measured velocities presented in Part I as the boundary condition. Distributions of heat, smoke, visible range and toxic gas on the platform are analysed for different smoke extraction flowrates corresponding to the two different emergency operation modes. The numerical results show that the extraction flowrate affects the smoke control performance significantly by improving the smoke removal performance as the extraction flowrate is increased.

Dynamic thermal properties of particulate foods in a continous flow cooking system (연속살균장치에서의 소고기 정육면체의 열전달특성 측정)

  • 홍지향;한영조;고학균
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1999.12a
    • /
    • pp.523-530
    • /
    • 1999
  • 연속살균장치는 $130^{\circ}C$에서 $140^{\circ}C$의 초고온에서 연속적으로 식품을 열처리 하는 공정으로 재래 배치식 공정에 비하여 순간적인 짧은 시간이 소요되는 경제적인 공정이나, 액상과 고상으로 구성된 저산도 식품은 고상입자의 대류열전달 계수와 장치내 체류시간이 정확히 구명되지 않아서 연속살균기술이 성공적으로 적용되지 못하고 있다. 본 연구에서 연속살균장치에서의 액상식품과 고상식품사이의 대류열전달 계수를 예측하기 위하여 연속살균장치의 Hold tube에서 정육면체 모델 식품내부의 온도를 측정할 수 있는 장치를 개발하였다. 연속살균장치의 홀드튜브에서 정육면체 모델 식품의 온도변화를 예측할 수 있는 유한차분법을 이용한 시뮬레이션 모델을 개발하고 소고기를 대상으로 이 시뮬레이션 모델의 입력변수인 비열, 열전도도를 실험적으로 측정하여 사용하였다. 0.0에서 15.0 centipoise의 점도를 가지는 모델 액상식품의 15.6에서 45.2liter/min 의 유속에 대하여 액상과 소고기 정육면체의 대류열전달계수는 792에서 2107W/$m^2$K으로 예측되었다.

  • PDF

Experimental study of natural transition in natural convection boundary layer (자연대류 경계층의 천이특성에 대한 실험적 연구)

  • Huang, ShengZhong;Yousif, Mustafa Z.;Lim, Hee-Chang
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.1
    • /
    • pp.29-37
    • /
    • 2022
  • We carried out a laboratory experiment about the thermo-fluidic characteristics of natural convection boundary layer over a vertical heated plate under constant heat flux condition. Particle image velocimetry has been applied to observe the surface convection velocity close to the vertical plate submerged in the water chamber with the condition of Ra = 7 × 109 and Pr = 8.1. The velocity distributions indicate that the distinct stripe-like structures appears in the upstream (earlier transition region) and the distinct negative-positive and Λ(λ)-shaped flow structures in the downstream (mid-transition region). In addition, the temporal variation of spanwise and streamwise velocity is also presented.

Study on Heat Transfer Characteristics for Single-phase Flow in Rectangular Microchannels (사각 마이크로 채널의 단상 유동 열전달 특성 연구)

  • Mun, Ji-Hyun;Kim, Seon-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.891-896
    • /
    • 2011
  • In this study, experiments were carried out to investigate the convective heat transfer characteristics of rectangular microchannels. The sample used in the experiments contained 20 rectangular microchannels in parallel. The channels had a hydraulic diameter of 700 ${\mu}m$. Distilled water was used as the working fluid. In the experiments, the Reynolds number ranged from 400 to 800, heat flux ranged from 35 to 85 kW/$m^2$, and the inlet fluid temperature was $20^{\circ}C$. As a result, the convective heat transfer coefficient increased upon increasing the Reynolds number and ranged from 4.6 to 6.4 kW/$m^2/^{\circ}C$ in the thermally fully developed region. Moreover, the higher the Reynolds number, the longer the thermal entry length in the rectangular microchannels. However, it was observed that a variable heat flux did not affect the thermal entry length. In conclusion, a correlation was proposed to indicate the heat transfer characteristics in a thermally fully developed region.

Visualization of Flow Characteristics on Thermosyphon with Immiscible Binary Working Fluid (비 혼합 2유체 열사이폰의 유동 특성에 관한 가시적 연구)

  • Do, Sun Yub;Kang, Hawn Kook;Park, Seung Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3022-3029
    • /
    • 2015
  • This study presents experiments to visualize the internal flow and heat transfer characteristics of thermosyphon with immiscible of water-FC40 adopted as binary working fluid. Three different regimes depending on the amount of heat flux applied to the thermosyphon were observed: natural convection, pulse boiling, and continuous boiling. Boiling incipience took place in water, which has lower vapor pressure than FC40. During natural convection water was vaporized in liquid pool while liquid film flows were formed. On the other hand, meanwhile bubbles were generated in the liquid pool during pulse and continuous boiling, the binary working fluid of water-FC40 was observed as the mixture throughout a whole range of the thermosyphon.