• Title/Summary/Keyword: 열 유속

Search Result 752, Processing Time 0.275 seconds

A Study on the Effects of Induced Mixture Flows and the Stratified Charge for a Lean Burn (희박연소를 위한 혼합기의 성층급기와 유동에 관한 연구)

  • 전대수;이태원;윤수한;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • In the present study, the IDI-type constant volume chamber, which utilizes the indirect injection stratified charge method, is used to solve several problems including misfires and cycle-variations caused by unstable initial ignitions. A subchamber has been used to make an ignitable mixture under the low mean equivalence ratio. After burned in the subchamber, the flame jet getting through the passage hode enters the main chamber and burns the lean charge. There are many factors which affect the combustion characteristics of the indirect injection stratified engine. The passage hole angle is the most important since it determines the direction of flame flows into the main chamber. In the present study, we measured the combustion pressure, and the wall temperature, and computed the heat flux through the cylinder wall in order to understand the combustion characteristics depending on passage hole angle and the equivalence ratio.

  • PDF

A Numerical Study on Prediction of Skin Burn Injury due to Flash Flame Exposure (돌발화염으로 인한 화상의 예측을 위한 수치해석 접근법에 대한 기초 연구)

  • Lee, Jun-Kyoung;Bang, Chang-Hoon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.167-170
    • /
    • 2011
  • 화재현장에서 소방공무원은 화염, 증기, 또는 고온물 등에 의하여 화상사고를 당하고, 이로 인하여 극심한 고통 받고 있다. 따라서 화상 예측에 대한 연구를 통해 화상을 방지할 수 있는 방법을 개발하여야 한다. 본 연구에서는 화재시 고온 열유속 조건하에서의 화상 발생에 대한 예측을 수치해석적 방법으로 수행하였다. 생체 열전달 방정식(Bio-heat transfer)을 이용하여 지배방정식을 유도하였으며, 유한차분법(Finite Difference Method)을 활용하여 피부조직에 대한 온도분포를 얻었다. 이를 바탕으로 한 손상함수를 이용하여 2도 화상의 발생 유무를 예측하였으며, 기존의 실험 결과[Stoll and Chianta]와 비교하여 좋은 예측 결과를 얻을 수 있었다.

  • PDF

Pressure Loss and Forced Convective Heat Transfer in an Annulus Filled with Aluminum Foam (발포 알루미늄이 삽입된 환형관에서의 압력손실 및 강제대류 열전달)

  • Noh Joo-Suk;Lee Kye-Bock;Lee Chung-Gu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.855-862
    • /
    • 2005
  • An experimental investigation has been carried out for aluminum foam heat sink inserted into the annulus to examine the feasibility as a heat sink for high performance forced water cooling in the annulus. The local wall temperature distribution, inlet and outlet pressures and temperatures, and heat transfer coefficients were measured for heat flux of 13.6, 18.9, 25.1, 31.4 $kw/m^2$ and Reynolds number ranged from 120 to 2000. Experimental results show that the friction factor is higher than clear annulus without aluminum foam, while the significant augmentation in Nu is obtained. This technique can be used for the compactness of the heat exchanger.

액막류의 MHF점에 관한 실험적 연구

  • 김영찬;서태원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.960-965
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increases with increasing the velocity and the subcooling of the liquid film flow.

  • PDF

Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate (고온 평판의 분무냉각에 있어서 MHF점에 관한 연구)

  • 김영찬
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

Prediction of Stratified Turbulent Channel Flows with an Second Moment Model Using the Elliptic Equations (타원 방정식을 사용하는 2차모멘트 모형에 의한 성층된 난류 평판유동의 예측)

  • Shin, Jong-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.12
    • /
    • pp.831-841
    • /
    • 2007
  • This work is to extend the elliptic operator, which has been already adopted in turbulent stress model, to fully developed turbulent buoyant channel flows with changing the orientation of the buoyancy vector to be perpendicular to the channel walls. The turbulent heat flux models based on the elliptic concept are employed and closely linked to the elliptic blending second moment closure which is used for the prediction of Reynolds stresses. In order to reflect the stable or unstable stratification conditions, the present model introduces the gradient Richardson number into the thermal to mechanical time scale ratio and model coefficients. The present model has been applied for the computation of stably and unstably stratified turbulent channel flows and the prediction results are directly compared to the DNS data.

경사유로내에서 유동비등에 관한 실험적 연구

  • 이태호;김문오;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.487-494
    • /
    • 1997
  • 비등이 발생하는 경사유로에서 이상유동 구조 파악을 위해 국부적 이상유동 변수의 측정이 이루어졌다. 국부 기포율, 국부 기포빈도, 국부기포속도 그리고 국부 기포크기와 같은 기상 관련 이상유동변수는 이중 전기전도도 탐침으로, 액상속도 분포는 Pilot tuba로 측정하였다. 유로의 경사도가 이상유동 구조에 미치는 영향을 파악하기 위해 실험은 수직, 수직으로부터 30도 경사도 및 60도 경사도에서 유량과 열유속을 변화시켜가며 수행하였으며 유동변수의 측정은 경사진 경우에 측면 방향으로의 대칭성을 고려하여 유로 반 단면내 총 91개 지점에서, 수직인 경우에는 13개 지점에서 이루어졌다. 유동조건은 1.4m/s 이하의 평균 액상 겉보기 속도에 제한되었고 유로내 압력은 대기압이며 유동양식은 미포화 비등에 국한되었다. 측정된 이상유동 변수의 분포를 이용하여 경사유로에 적용할 수 있는 distribution parameter와 drift velocity 같은 dirft flux parameter에 대한 상관식이 개발되었다.

  • PDF

범용 전산유체 코드를 이용한 봉 다발에서의 난류 유동 수치해석

  • 인왕기;오동석;전태현;정연호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.567-572
    • /
    • 1997
  • 범용 전산유체해석(Computational Fluid Dynamics) 코드인 CFX-F3D를 이용하여 봉 다발에서의 난류 유동 수치해석을 수행하였다 3$\times$3 봉으로 구성된 부수로 사이의 난류 횡류(Crossflow) 혼합유동과 평행한 4개의 봉으로 이루어진 벽 수로에서의 난류 유동구조를 수치적으로 분석하여 각각의 실험결과와 비교하였다. 부수로 횡류 혼합유동의 경우 예측된 주 유동방향 평균 속도분포는 실험결과와 잘 일치하였으나 벽면과 인접한 부수로에서의 난류강도 분포는 다소 큰 차이가 나타났다. 백수로의 경우 수로 중심선 근처의 주 유동방향의 속도변화는 크게 예측되었고 벽 전단응력은 유로가 협소해지는 영역에서 낮게 예측되었으나 전반적으로 실험결과와 유사한 유동특성을 나타냈다. 이 연구는 봉 다발에서의 난류 유동구조에 대한 이해를 증진시킴과 더불어 CFX-F3D 코드를 평가함으로써 향후 지지격자와 임계열유속 증진장치가 부착된 복잡한 형상의 핵연료 다발에서의 유동장 수치해석의 기반을 마련하였다.

  • PDF

A Low-Reynolds Number Second Moment Closure for Turbulent Heat Fluxes (저레이놀즈수 2차 모멘트 난류 열유속모형 개발에 관한 연구)

  • 신종근;최영돈;이건휘
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.12
    • /
    • pp.3196-3207
    • /
    • 1993
  • A second moment turbulent closure for the turbulent heat flux near a wall is developed by modification of model constants in pressure interaction term as the variables of the turbulent Reynolds number using the universal properties of turbulent heat flux near the wall. The present model shows that model constant for the wall reflection term in pressure interaction is most important in modelling of the near wall heat flux. Fully developed pipe flows with constant wall heat flux are tested to validate the proposed model. In most of calculation region, the predicted turbulent properties agree better with the experimetal data than the results from standard algebraic heat flux model which use the uniform model constants.

Velocity and Temperature Visualization of Air Convection in Differently Heated Rectangular Cavity with Upper Channel (상부채널을 갖는 사각공간에서 열유속 변화에 따른 공기대류의 속도와 온도 가시화)

  • Lee, C.J.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.53-60
    • /
    • 2000
  • An experimental study was carried out in a cavity with upper channel and square heat surface by visualization equipment with Mach-Zehnder interferometer and laser apparatus. The visualization system consists of 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system(CACTUS'2000). Obtained result showed various flow patterns. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach-Zehnder are also compared in terms of constant heat flux.

  • PDF