• 제목/요약/키워드: 열 유속

검색결과 752건 처리시간 0.024초

임계열유속 향상을 위한 나노물질의 산화처리에 대한 연구 (Study on the Oxidation Treatment of Nanoparticles for the Critical Heat Flux)

  • 김우중;전용한;김남진
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.39-49
    • /
    • 2017
  • Pool boiling, one of the key thermal-hydraulics phenomena, has been widely studied for improving heat transfer efficiencies and safety of nuclear power plants, refrigerating systems, solar-collector heat pipes, and other facilities and equipments. In the present study, the critical heat flux (CHF) and heat-transfer coefficients were tested under the pool-boiling state using graphene M-5 and M-15 nanofluids as well as oxidized graphene M-5 nanofluid. The results showed that the highest CHF increase for both graphene M-5 and M-15 was at the 0.01% volume fraction and, moreover, that the CHF-increase ratio for small-diameter graphene M-5 was higher than that for large-diameter graphene M-15. Also at the 0.01% volume fraction, the oxidized graphene M-5 nanofluid showed a 41.82%-higher CHF-increase ratio and a 26.7%-higher heat-transfer coefficient relative to the same nanofluid without oxidation treatment at the excess temperature where the CHF of distilled water occurs.

유리용융로에서 자유표면 열유속과 좌우벽면 온도차에 의한 자연대류 (Natural convection induced by free surface heat flux and temperature difference between left and right walls in glass melting furnace)

  • 임광옥;이관수
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3706-3713
    • /
    • 1996
  • A numerical study on natural convection induced by free surface heat flux and cold left and hot right walls in glass melting furnaces has been performed. A function of heat flux derived from the combustion environments of actual glass melting furnace is applied to thermal boundary condition at free surface. Fundamentally there exist two flow cells in cavity (left counterclockwise one and right clockwise one). The effects of heat flux and Rayleigh number are investigated through two-dimensional steady-state assumption. The convection strength of two flow cell located in left region continuously increases. In the mean time the strength of flow cell in right region increases and then decreases. Critical Rayleigh number in which two flow cells take place above and below show linear dependence on the free surface heat flux. To maintain the traditional flow pattern (left and right flow cells) in glass melting furnace, Rayleigh number is recommended to be below 10$^{5}$ .

타원방정식에 의한 벽면 부근의 난류열유속 모형화 (Near-Wall Modelling of Turbulent Heat Fluxes by Elliptic Equation)

  • 신종근;안정수;최영돈
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.526-534
    • /
    • 2004
  • A new second-moment closure model for turbulent heat fluxes is proposed on the basis of the elliptic equation. The new model satisfies the near-wall balance between viscous diffusion, viscous dissipation and temperature-pressure gradient correlation, and also has the characteristics of approaching its respective conventional high Reynolds number model far away from the wall. The predictions of turbulent heat transfer in a channel flow have been carried out with constant wall heat flux and constant wall temperature difference boundary conditions respectively. The velocity field variables are supplied from the DNS data and the differential equations only fur the mean temperature and the scalar flux are solved by the present calculations. The present model is tested by direct comparisons with the DNS to validate the performance of the model predictions. The prediction results show that the behavior of the turbulent heat fluxes in the whole region is well captured by the present model.

일정 열유속의 하부 가열면을 갖는 채널캐비티 내부유동의 PIV 계측 (PlV Measurement of Channel Cavity Flow with Bottom Heat surface of Constant Heat Flux)

  • 조대환;김진구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권4호
    • /
    • pp.437-442
    • /
    • 1997
  • An experimental study was carried out in a channel cavity with square heat surface by visual¬ization equipment with Mach - Zehnder interferometer and laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two¬frame grey-level cross correlation algorithm. Heat source was uniform heat flux(o.4W/cm$^2$, , O.8W/cm$^2$, 1.2W/cm$^2$). Obtained result showed various flow patterns such as kinetic energy distribution. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach ~ Zehnder are also compared in terms of constant heat flux.

  • PDF

임계 열유속 근방까지의 풀 비등 열전달계수 (Pool Boiling Heat Transfer Coefficients Upto Critical Heat flux)

  • 박기정;정동수
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.571-580
    • /
    • 2008
  • In this work, pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of differing vapor pressure are measured on horizontal smooth square surface of 9.52 mm length. Tested refrigerants are R123, R152a, R134a, R22, and R32 and HTCs are taken from $10\;kW/m^2$ to critical heat flux of each refrigerant. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and by thermocouples in the liquid pool. Test results show that pool boiling HTCs of refrigerants increase as the heat flux and vapor pressure increase. This typical trend is maintained even at high heat fluxes above $200\;kW/m^2$. Zuber's prediction equation for critical heat flux is quite accurate showing a maximum deviation of 21% for all refrigerants tested. For all refrigerant data up to the critical heat flux, Stephan and Abdelsalam's well known correlation underpredicted the data with an average deviation of 21.3% while Cooper's correlation overpredicted the data with an average deviation of 14.2%. On the other hand, Gorenflo's and lung et al.'s correlation showed only 5.8% and 6.4% deviations respectively in the entire nucleate boiling range.

KIER 태양로의 열유속 분포 특성 (Characteristic of the Radiation Heat Flux Distribution for the KIER Solar Furnace)

  • 채관교;이현진;김종규;윤환기;이상남;강용혁;서태범
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2011
  • Concentration characteristics of the KIER solar furnace are analyzed with a heat flux measurement technique. Total heat capacity of 40kW was confirmed within 1.04% average error, and the normalized maximum heat flux of 3,452 $kW/m^2$ was proved. Non-Gaussian flux distribution in the vertical direction implies that reflectors should not be random rather inclined downwards. Moreover, we characterized flux distribution variations with furnace blind opening ratio, distance from the focal plane, and misalignment of the measurement system. Based on the results, the heat flux distribution can be simply estimated once reflectivity and direct normal insolation values are known. This study will be helpful to the design and the performance evaluation of receivers or chemical reactors.

  • PDF

프로필렌 수직벽 화재의 수치적 연구 (Numerical Study on Propylene Vertical Wall Fires)

  • 박외철
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.133-137
    • /
    • 2009
  • 화재 시뮬레이션용 전산유체역학 모델인 Fire Dynamics Simulator(FDS)을 이용한 수직벽 화재 시뮬레이션의 정확성을 확인하기 위해 FDS를 프로필렌 수직벽 화재에 적용하였다. 단위면적당 연소율 $7.0{\sim}29.29g/m^2-s$의 범위에서 버너중심에서의 경계층 내 온도분포를 실험결과와 비교하였다. 또 수직벽면 위 수직중심선을 따라 계산한 열유속(heat flux) 분포도 실험과 비교하였다. 경계층 내 온도분포는 비교적 잘 예측됨을 확인하였다. 그러나 벽면근처의 최고온도는 측정치보다 낮았고, 수직벽면의 열유속은 지나치게 높게 나타났다. 이에 따라 수직벽 화재의 시뮬레이션에 있어서 FDS를 개선할 필요가 있음을 확인하였다.

과산화수소/케로신 액체로켓엔진의 막냉각 특성에 관한 연구 (Study on Film Cooling Characteristic of a Liquid Rocket Engine using Hydrogen Peroxide/Kerosene)

  • 최유리;전준수;채병찬;민지홍;고영성;김선진;김유
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제35회 추계학술대회논문집
    • /
    • pp.601-604
    • /
    • 2010
  • 본 연구는 과산화수소와 케로신을 추진제로 하는 액체로켓엔진에 막냉각 링을 장착하여 막냉각 효과에 관한 연구를 수행하였다. 막냉각제의 유량 및 냉각장치 형상에 따른 열유속을 계산하기 위하여 축방향으로 열전대를 장착하여 온도를 측정하였다. 냉각제 유량은 총 추진제 유량의 0~20%의 유량으로 선정하여 실험을 수행하였다.

  • PDF

선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법 (Fire test procedures for flammability of bulkhead, ceiling and deck finish materials)

  • 김성윤;김동석;안병호;노호성
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2007년도 춘계학술발표회
    • /
    • pp.157-159
    • /
    • 2007
  • 해상에서의 화재로부터 사람의 목숨과 재산을 보호하는 것은 대단히 중요하다. 따라서, "격벽, 천장, 갑판 마감재의 표면 연소성에 대한 개선된 화재시험절차에 관한 권고"는 선박의 격벽, 천정, 갑판 마감재의 연소특성을 결정짓기 위한 근거로써 화재 특성 및 그 재료들을 해상구조물에 사용함에 있어서 적합성을 측정하기 위한 절차를 규정하고 있다. 이 논문에서는 선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법을 제시하고 그 적정성을 평가하고자 한다. 또한 특이한 거동을 보이는 물질을 조사하고, 그 물질들의 적합한 시험방법을 제시하고자 한다.

  • PDF

이중냉각핵연료 온도 및 열유속 분리 평가 (Temperature and Heat Split Evaluation of Annular Fuel)

  • 양용식;전태현;신창환;송근우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2236-2241
    • /
    • 2008
  • The surface heat flux of nuclear fuel rod is the most important factor which can affect safety of reactor and fuel. If fuel rod surface heat flux exceeds the CHF(${\underline{C}}ritical$ ${\underline{H}}eat$ ${\underline{F}}lux$), fuel can be damaged. In case of double cooled annular fuel, which is under developing, contains two coolant channels. Therefore, a generated heat in the fuel pellet can move to inner or outer channel and heat flow direction is decided by both sides heat resistance which varied by dimension and material property change which caused by temperature and irradiation. The new program(called DUO) was developed. For the calculation of surface heat flux, a both sides convection by inner/outer coolant, s gap temperature jump and conduction in the fuel are modeled. Especially, temperature and time dependent fuel dimension and material property change are considered during the iteration. A sample calculation result shows that the DUO program has sufficient performance for annular fuel thermal hydraulics design.

  • PDF