• Title/Summary/Keyword: 열 손실

Search Result 1,030, Processing Time 0.025 seconds

The Effect of Heat Loss on the Radial Heat Flow in the Flash Method (반경방향 열흐름 섬광법에서 열손실의 영향)

  • 이홍주;김순규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.2
    • /
    • pp.257-264
    • /
    • 1989
  • For the extension of the flash method the heat diffusion equation with heat loss and with an arbitrary heat pulse is mathematically analyzed. In the analysis the heat loss includes the axial and radial directions on the front, rear and peripheral surfaces. The heat pulse is irradiated from the source to the front surface of the sample and the heat receiving area on the front surface is controlled by the apertures of an optical system. From this analysis the thermal diffusivity of the samples can be determined more precisely than before by the data reduction method using various percent time. The data can be obtained by the extended radial flash technique adjusted correctly the heating area on the central part of the front surface with a proper aperture or the conventional axial flash technique heated uniformly all parts of the front surface.

Estimation of Air-Sea Heat Exchange Using BUOY Data at the Yellow Sea, Korea (부이 관측자료를 이용한 서해 해역의 해양-대기 열교환량 산출)

  • kang, Yune-Jeung;Hwang, Seung-On;Kim, Tae-Hee;Nam, Jae-Cheol
    • Journal of the Korean earth science society
    • /
    • v.22 no.1
    • /
    • pp.40-46
    • /
    • 2001
  • Heat exchange between the atmosphere and sea is produced using the data from two 3m discus buoy installed by KMA in 1996. The meteorological and oceanic characteristics at the Dukjukdo and Chilbaldo buoy for the period 1996 ${\sim}$ 2000 are discussed. Daily averaged sensible heat and latent heat flux at each site are estimated from bulk aerodynamic method using given data and analyzed. Quantitative analyses show SST indicates 1-year cycle like air temperature but has 1 month lag. Sea level pressure is lowest in July, humidity is higher from May to August, and wind speed has averaged value of 5 m/s and higher in autumn and winter. Sensible heat flux analyses present that strong heat loss from the sea occurs in autumn and winter and weak heat loss from atmosphere appears in spring and summer, and net sensible heat loss from the sea is found throughout the year. The ocean significantly releases latent heat into atmosphere from August to May but get a little latent heat from atmosphere in other months. Net latent heat loss from the sea is larger than net sensible heat loss except in January and February. Comparison with two sites suggests that the magnitude of heat flux and their fluctuation are generally stronger at Dukjukdo than at Chilbaldo. In case study, both sensible and latent heat flux is a little more at Chilbaldo in March 1998, but substantially stronger at Dukjukdo in November 1996.

  • PDF

Heat Balance during the Electrowinning of Neodymium Metal in Molten Salt (네오디뮴 금속의 전해 채취 중의 열수지)

  • Cho, Sung-Wook;Yu, Jeong-Hyun;Choi, Ho-Gil
    • Resources Recycling
    • /
    • v.31 no.3
    • /
    • pp.81-87
    • /
    • 2022
  • Energy consumption per unit weight of metal (kwh/kg of metal) is one of the most important economic indicators in the process of molten salt electrolysis. It is related to the heat loss of salt bath and the current efficiency of the process. The current efficiency is highly dependent on electrolysis temperature. On the other hand, the temperature of salt bath may increase significantly due to the difference (larger energy input than consumption) in heat balance at the beginning of electrolysis, which may cause different electrolysis temperature from an initially targeted value. This results in a bad effect on current efficiency. Therefore, it will be helpful to the reduction of energy consumption to compare the calculated and measured values of the temperature change of salt bath through the heat balance review at the early stage of electrolysis and to evaluate the energy loss to outside. In this study, based on the authors' experimental data, the heat balance was reviewed at the beginning of the electrolysis, and it was possible to evaluate the energy loss to the outside and the increase of the temperature of the salt bath quantitatively. Through such a method, heat loss reduction plan can be derived and current efficiency can be improved so that energy consumption can be reduced.

Analysis of Pressure Drop and Heat Loss in Liquid Sodium Circulation Wick of AMTEC (AMTEC의 소디움액체 순환윅에서 압력손실 및 열손실해석)

  • Lee, Ki-Woo;Lee, Wook-Hyun;Rhi, Seok-Ho;Lee, Kye-Bock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.953-960
    • /
    • 2012
  • An AMTEC (alkali metal thermal electric converter) is a device that is used for the direct conversion of heat to electricity. Sodium is used as the working fluid, and its circulation is driven by a capillary wick. The wicks used for circulation include an evaporator wick, artery wick, and condenser wick, and each wick has a pressure drop because of the circulation of liquid and vapor. For the circulation of sodium, the capillary pressure of the evaporator wick must be greater than the total pressure drop in the wicks. In this study, the pressure drop in the evaporator wick, artery wick, and condenser wick and the heat loss from the evaporator to the condenser through the artery wick were analyzed for the design of a 100 W AMTEC prototype. It was found that a particle diameter of 10 ${\mu}m$ is suitable for the evaporator wick to maintain a capillary pressure greater than total pressure drop in the circulation loop.

Study on Thermal Efficiency according to Configuration Change and Contact Resistance of Solar Collector with Single Evacuated Tube-type (단일진공관 태양열집열기의 형상변화 및 접촉저항에 따른 집열효율 연구)

  • Choi, Bo-Won;Yang, Young-Joon
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.189-195
    • /
    • 2014
  • The use of solar energy among renewable energy tends to increase because of its infinity and cleanness of resources. Even though the consumption rate of solar energy in our country is still low, however, in recent years, the research for solar energy have been widely conducted due to policy support of government. This study was performed to investigate the efficiency of heat collection using solar collector with single evacuated tube-type. As the results, the temperature of radiation fin for solar collector with single evacuated tube-type was lower in spite of high temperature of heat pipe compared that of double evacuated tube-type. In order to increase the efficiency of heat collection, it was confirmed that the loss of heat collection due to contact resistance as well as performance improvement for solar collector should be decreased.

Evaluation of Energy Consumption in Heat Treatment of Pine Log (소나무 원목의 열처리 소요 에너지 평가)

  • Eom, Chang-Deuk;Park, Jun-Ho;Han, Yeon Jung;Shin, Sang-Chul;Chung, YoungJin;Jung, Chan-Sik;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.41-48
    • /
    • 2008
  • The required energy for the heat treatment of pine log was evaluated in this study. A proper heat treatment of pine log infected by pinewood nematode (Bursaphelenchus xylophilus) can prevent spreading of the infection by pinewood nematode and make the infected pinewood valuable again. The FAO (Food and Agriculture Organization of the United Nations) heat treatment standard for various types of infected wood for which a heat treatment of the core part of the wood is necessary is 30 minutes at $56^{\circ}C$, taking into account the international standards for phytosanitary measures (ISPM No. 15). In this study, the energy consumption during the heat treatment was separated into two kinds of energy, initial energy for heating kiln drier and to reach set point temperature and relative humidity and the required energy supplementing heat loss. The initial required energy per unit time is greater than that during the treatment. The energy consumption per unit time varied little during the heat treatment. As a result, the set point relative humidity with set dry bulb temperature and density of wood dependent on moisture content are very important factors to change energy consumption in the experiment. The heat treatment at higher temperature and higher humidity levels requires more energy consumption but less treatment time. It is expected that a more effective energy program could be planed for the heat treatment of pine log through this study.

Application of Exergy to the Analysis and Optimization of Heat Transfer Processes (열전달 과정의 해석과 최적화를 위한 엑서지의 응용)

  • Auracher H.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.6
    • /
    • pp.542-549
    • /
    • 1987
  • 중요한 기본을 요약하고 엑서지를 에너지 변환에서 가장 중요한 기본 과정에 응용하는 열전달 문제를 제시한다. 열전달로 인한 엑서지 손실과 고온체, 저온체의 단열, 열교환기의 설계와 관련된 결과를 논의한다. 또한 비아제오트로픽(non-azeotropic) 혼합물을 응용한 열펌프 열교환기에서의 엑서지 절약에 대한 연구를 설명한다. 열전달과 압력강하로 인한 손실의 합인 총엑서지 손실이 최소로 되는 최적의 Reymolds 수가 존재함을 보여준다.

  • PDF

A Study on the Frame Structure for the Performance Improvement of Digital Terrestrial TV Receiver (디지털 지상파 TV 수신 성능 향상을 위한 데이터 프레임 구조에 관한 연구)

  • 박성우;김철민;김대진;전희영
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.313-316
    • /
    • 2000
  • 본 논문에서는 동적 다중경로 환경에 대한 DTV수신 성능 개선을 위하여 정보 데이터 세그먼트 부분에서는 Stop and Go 알고리즘을 사용하고 313 세그먼트 중 한 개만이 훈련열로 쓰이는 기존의 ATSC 표준의 데이터 프레임 구조보다 더 많은 훈련열이 들어있는 새로운 데이터 프레임 구조를 제안한다. 정보가 없는 널 패킷을 훈련열로 대체하기 때문에 데이터의 손실 없이 더 많은 훈련열을 사용하여 특히 동적 다중경로 환경에서 등화기의 수렴 특성을 개선할 수 있다. 전산 모의 실험을 통하여 동적 다중경로 환경의 도플러 천이에 대한 시스템 수신 성능의 개선을 확인하였다.

  • PDF

RAPID THERMAL ppROCESS시 실리콘 웨이퍼 온도 분포와 열 응력 해석

  • 안강호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1993.02a
    • /
    • pp.38-40
    • /
    • 1993
  • 급속 열처리 시스템내에서의 비정상상태 온도분포, 가스유동형태, 웨이퍼내 열응력등을 여러 가지 작동조건하에서 2차원 유한 차분법으로 계산하였다. 계산결과는 실험에서 얻은 에피성장률 데이터와 비교 검증하였다. RTpp내 가스 유동이나 온도분포는 압력 및 주위 구성요소에 크게 의존하는 반면, 웨이퍼의 온도분포는 wafer edge loss가 큰 고온에서 온도 불균일도가 가장 크다. 저온에서는 대류에 의한 열 손실이 웨이퍼내의 온도 불균일도에 큰 영향을 미치고 있다. 웨이퍼상의 열응력을 가장 크게 받는 시점은 transient condition에서 나타났다.

  • PDF

A numerical study on effects of thermal buoyance force on number of jet fans for smoke control (도로터널 화재시 열부력이 제연용 제트팬 댓수에 미치는 영향에 대한 해석적 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.3
    • /
    • pp.301-310
    • /
    • 2013
  • Jet fans are installed in road tunnels in order to maintain critical velocity when fire occurs. Generally the number of jet fans against fire are calculated by considering critical velocity and flow resistance by wall friction, vehicle drag force, thermal buoyance force and natural wind. In domestic case, thermal buoyance force is not considered in estimating the number of jet fans. So, in this study, we investigated the pressure loss due to the thermal buoyance force induced by tunnel air temperature rise and the impact of thermal buoyance force on the number of jet fans by the numerical fire simulation for the tunnel length(500, 750, 1000, 1500, 2000, 3500m) and grade (-1.0, -1.5, -2.0%). Considering the thermal buoyance force, number of jet fans have to be increased. Especially in the case of 100MW of heat release rate, the pressure loss due to thermal buoyance force exceed the maximum pressure loss due to vehicle drag resistance, so it is analyzed that number of 2~11 jet fans are needed additionally than current design criteria. Thus, in case of estimating the number of jet fans, it must be considered of thermal buoyance force induced tunnel air temperature rise by fire.