• Title/Summary/Keyword: 열 복사

Search Result 727, Processing Time 0.036 seconds

CFD-based Fire Accident Impact Analysis in Clean Room for semiconductor PR Process (반도체 PR 공정의 클린룸내 CFD 기반 화재 사고 영향 분석)

  • Chun, Kwang-Su;Yi, Jinseok;Park, Myeongnam
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.35-44
    • /
    • 2021
  • The PR (Photo Resist) process in the semiconductor process is a process that uses a mixture of flammable substances. Due to the process equipment is installed in a clean room and when flammable substances leak, there is a high risk of suffocation, fire, and explosion. It is necessary to analyze the impact of accidents that may occur during operation and to evaluate whether the safety of workers can be guaranteed. In this study, the value of radiant heat and temperature change at the monitor point set up virtual inside the clean room was confirmed through CFD simulation of 10 leak and fire scenarios using the FLACS CFD - Fire Module. A fire that occurs inside a clean room transfers high radiant heat to the inter-story structure, but its scope is quite limited, and it is unlikely that it will collapse in a single fire accident. There was no scenario in which two stairs leading to the exit were exposed to high radiant heat at the same time due to a fire accident, therefore workers were able to escape in case of a fire. In addition, it was confirmed that the level of radiant heat and temperature rise rapidly decreased as they moved downstairs. According to the API 520 standard, workers exposed to 6.31 kW/m2 of radiant heat that workers can withstand for 30 seconds were confirmed that it was possible to sufficiently escape from the inside.

A study on damage prediction analysis for styrene monomer fire explosion accidents (스티렌 모노머 화재폭발사고 피해예측 분석에 관한 연구)

  • Hyung-Su Choi;Min-Je Choi;Guy-Sun Cho
    • Industry Promotion Research
    • /
    • v.9 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • This study selected the worst-case scenario for fireball and vapor cloud explosion (VCE) of a styrene monomer storage tank installed in a petrochemical production plant and performed damage prediction and accident impact analysis. The range of influence of radiant heat and overpressure due to fireball and vapor VCE during the abnormal polymerization reaction of styrene monomer, the main component of the mixed residue oil storage tank, was quantitatively analyzed by applying the e-CA accident damage prediction program. The damage impact areas of radiant heat and explosion overpressure are analyzed to have a maximum radius of 1,150m and 626m, respectively. People within 1,150m of radiant heat of 4kW/m2 may have their skin swell when exposed to it for 20 seconds. In buildings within 626m, where an explosion overpressure of 21kPa is applied, steel structures may be damaged and separated from the foundation, and people may suffer physical injuries. In the event of a fire, explosion or leak, determine the risk standards such as the degree of risk and acceptability to workers in the work place, nearby residents, or surrounding facilities due to radiant heat or overpressure, identify the hazards and risks of the materials handled, and establish an emergency response system. It is expected that it will be helpful in establishing measures to minimize damage to workplaces through improvement and investment activities.

Simulation of the Thermal Performance on an Ondol House with Hot Water Heating in Consideration of Radiation Heat Transfer (복사열전달을 고려한 모형 온수온돌 주택 열성능 시뮬레이션)

  • Choi, Y.D.;Yoon, J.H.;Hong, J.K.;Lee, N.H.;Kang, D.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.295-305
    • /
    • 1993
  • Thermal performance of test cell of model hot water Ondol house was simulated by equivalence heat resistence and heat capacity method. In this method wall was replaced by two equivalence and one heat capacity. This method enables to simulate the variation of temperature of each element of model house. The effect of pipe diameter, pitch of pipe and with or without consideration of inter-radiation between wall surfaces on the energy consumption rate were investgated. Results show that radiations between the ground surface of room and wall surfaces contribute to the heating of room air by reducing the convection heat loss through the wall surfaces.

  • PDF

HYDROMAGNETIC FLOW IN A CAVITY WITH RADIATIVELY ACTIVE WALLS (복사벽면으로 구성된 캐비티 내 전자열유체 유동)

  • Han, Cho-Young;Chae, Jong-Won;Kim, Jung-Hoon;Jun, Hyoung-Yoll
    • Journal of computational fluids engineering
    • /
    • v.15 no.3
    • /
    • pp.87-94
    • /
    • 2010
  • Hydromagnetic flow in a cavity under a uniform magnetic field is studied numerically. The cavity is comprised of four radiatively active surfaces. Due to large temperature difference inside a cavity, the radiative interaction between walls is taken into account. The coupled momentum and energy equations are solved by SIMPLER algorithm while the radiant heat exchanges are obtained by the finite volume method for radiation. A Wide range of Grashof numbers is examined as a controlling parameter. Resultant flow and heat transfer characteristics are investigated as well.

A Study on the Thermal and Flow Characteristics of Wind and Radiant Heat Shield for Offshore by using Mesh Screen (메쉬 스크린을 적용한 해양구조물용 방풍 및 복사열 차단막 열유동특성에 관한 연구)

  • Yi, Chung-Seob;Chin, Do-Hun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.3
    • /
    • pp.166-173
    • /
    • 2012
  • This study is about comparison of thermal and flow characteristics on the wind & radiant heat shield with STS mesh type screen for offshore. Numerical analysis was conducted to find transmission coefficient in the mesh and then analyse the flow characteristics about wind & radiant heat shield. The experiment method of solar radiation has been used as thermal radiation source to get the performance of radiant heat shield measurement. The sensor radiation device has been used to measure the reduction of solar radiation with various size of cells and at a distance of 0.5m and 1m from the cold face of the wind & radiant heat shield.

RADIATION HEAT TRANSFER IN HORIZONTAL CYLINDRICAL ANNULUS (수평원관 사이 환상유로에서의 복사열전달 연구)

  • Han, C.Y.;Park, E.S.;Jeon, H.Y.;Yu, M.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.75-77
    • /
    • 2011
  • Thermofluid flow analysis is major subject in most computational fluid dynamics applications. Accompanying convective and conductive heat transport phenomena, radiation plays an important role in high temperature operating systems. Cares in which the radiation dominates are found in such systems as boilers, furnaces, rocket engines, etc. In this paper the finite-volume method (FVM) are employed to simulate two-dimensional radiation problems in concentric and eccentric horizontal cylindrical annuli with general body-fitted coordinates. In that case the simplest and intuitive remedies are proposed for mitigation of ray effect.

  • PDF

A Thermal Flow Analysis for an Optimal shape of Solar Lamp Bank (최적의 램프뱅크형태를 결정하기 위한 열유동 해석)

  • Baek, Sang-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.82-89
    • /
    • 2012
  • This study is on the thermal flow analysis to select an optimal shape of solar lamp bank. Solar Lamp bank is designed by the lamp bank design program based on point light source theory. The reliability of the program for lamp bank design is verified through irradiance variation experiments of a kind of lamp according to horizontal distance. Solar lamp bank facilitates heat distribution and satisfies the irradiance in the three wave length which test guidelines require. Among the 4 kinds of lamp bank, since lamp bank type D satisfies uniformity ${\pm}10%$ and also doesn't exceed total irradiance 1,232 $W/m^2$, type D is finally selected.

Simulation of Heat Supply Control of Continuous Heating System of Multistoried Apartment in Consideration of Radiation Heat Transfer (복사열전달을 고려한 고층아파트 연속난방 열공급제어 시뮬레이션)

  • Choi, Y.D.;Hong, J.K.;Yoon, J.H.;Lee, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.78-92
    • /
    • 1994
  • Thermal performance of pipe network of continuous heating system controlled by thermostat and flow control valve was simulated in consideration of radiation heat transfer and solved by linear analysis method. Thermal performance of real apartment building with radiant floor heating system was simulated by equivalence heat resistance-capacity method. This method enables to simulate the unsteady variation of temperature or each element of building. Heat transfer characteristics of each element were also investigated.

  • PDF

Heat and Mass Transfer in Highly Porous Media (고 다공성 물질에서 열 및 물질전달)

  • 이금배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.685-693
    • /
    • 1990
  • The heat transfer coefficients were calculated numerically to see the effects of radiation around the porous medium put on the flat plate at a distance from the leading edge of flat plate for the two-dimensional laminar flows. To verify the analytical model developed and invoke the heat/mass transfer analogy, an experiment was carried out using naphthalene sublimation technique. From the effects of the wake, Sherwood number is maximum around the region where the porous medium is attached. The theoretical results correspond well with the experimental results at small Darcy number. Permeability of ceramic blocks used for experiment was also measured and the Forchheimer equation is applicable in our measurement range.

광학탑재체 냉각유닛 열완충질량의 효과 분석

  • Jang, Su-Yeong;Lee, Deok-Gyu;Lee, Eung-Sik;Yeon, Jeong-Heum;Lee, Seung-Hun
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.50.2-50.2
    • /
    • 2009
  • 지구관측위성의 광학탑재체 내부에 장착된 초점면결상장치(FPA, Focal Plane Assembly)는 영상촬영시 많은 열을 발생하며, 최상성능획득을 위해서는 온도가 좁은 온도범위 내에서 유지되어야 한다. 초점면결상장치가 짧은 시간 동안 많은 열을 발생할 때, 이를 효과적으로 냉각시키기 위해 보통 히트파이프와 복사방열판을 이용한다. 이번 연구에서는 초점면결상장치의 최대상승온도를 낮추고, 영상촬영대기시 최적온도유지를 위한 히터작동율을 낮추기 위해 초점면결상장치와 복사방열판 사이에 열완충질량(TBM, Thermal Buffer Mass)을 적용하였는데, 이를 통해 얻을 수 있는 열설계 개선효과에 대해서 기술한다.

  • PDF