• Title/Summary/Keyword: 열 모드 해석

Search Result 104, Processing Time 0.02 seconds

Design of Variable Optical Attenuators Incorporating Large Core Polymer Waveguides (대형 코어 폴리머 광도파로를 이용한 가변 광감쇠기 설계)

  • Cho, Su-Hong;Oh, Min-Choel
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.254-260
    • /
    • 2005
  • By incorporating large core polymer waveguides, which have been developed for increased alignment tolerance in passive fiber attachment, highly efficient variable optical attenuators are proposed. In order to find optimum device structures, 3-dimensional beam propagation method (BPM) simulations are performed. Heat distribution over the polymer film is calculated to find the 3-dimensional index profile data for the BPM simulation. Due to the small index contrast between the core and cladding materials in the large core waveguide, heat-induced radiation occurs for small heating power. While the ordinary VOA needs the temperature to change over $150^{\circ}C$ for 20 dB attenuation, the large core VOA requires only $70^{\circ}C$. In addition to the merit of passive fiber attachment, the proposed VOA has enhanced attenuation efficiency for the lower temperature change.

Characterization for Viscoelasticity of Glass Fiber Reinforced Epoxy Composite and Application to Thermal Warpage Analysis in Printed Circuit Board (유리섬유강화 복합재의 점탄성 특성 규명 및 인쇄회로기판 열변형해석에의 적용)

  • Song, Woo-Jin;Ku, Tae-Wan;Kang, Beom-Soo;Kim, Jeong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.245-253
    • /
    • 2010
  • The reliability problems of flip chip packages subjected to temperature change during the packaging process mainly occur due to mismatches in the coefficients of thermal expansion as well as features with time-dependent material properties. Resin molding compounds like glass fiber reinforced epoxy composites used as the dielectric layer in printed circuit boards (PCB) strongly exhibit viscoelastic behavior, which causes their Young's moduli to not only be temperature-dependent but also time-dependent. In this study, the stress relaxation and creep tests were used to characterize the viscoelastic properties of the glass fiber reinforced epoxy composite. Using the viscoelastic properties, finite element analysis (FEA) was employed to simulate thermal loading in the pre-baking process and predict thermal warpage. Furthermore, the effect of viscoelastic features for the major polymeric material on the dielectric layer in the PCB (the glass fiber reinforced epoxy composite) was investigated using FEA.

A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building (업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 -)

  • Chung, Hwan-Kyo;Chung, Kwang-Seop;Lee, Yong-Jun;Shin, Seung-Chul;Kim, Young-Il
    • Journal of Energy Engineering
    • /
    • v.21 no.2
    • /
    • pp.168-178
    • /
    • 2012
  • The objective of this study is applied to office buildings to evaluate quantitative evaluation method about performance of double-skin at design stage to establish the basis for the purpose of evaluation performance. Select the evaluation building about design plan for applying the double-skin using the dynamic heat load analysis program the annual heating and cooling load of before and after the double-skin. Using CFD to analyze wind factor and applied ventilation for realistic results. Effects of double-skin to apply, and control techniques that can be done more realistically proposed through to set and control for shade control mode of ventilator and inside cavity wall of double-skin. Apply for the building the double-skin due to interpretation of the annual heating and cooling loads applied to interpret the quantitative effect confirmed the possibility. According to the form of a double skin was confirmed cavity environmental changes.

Grand Circulation Process of Beach Cusp and its Seasonal Variation at the Mang-Bang Beach from the Perspective of Trapped Mode Edge Waves as the Driving Mechanism of Beach Cusp Formation (맹방해안에서 관측되는 Beach Cusp의 일 년에 걸친 대순환 과정과 계절별 특성 - 여러 생성기작 중 포획모드 Edge Waves를 중심으로)

  • Cho, Yong Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.5
    • /
    • pp.265-277
    • /
    • 2019
  • Using the measured data of waves and shore-line, we reviewed the grand circulation process and seasonal variation of beach cusp at the Mang-Bang beach from the perspective of trapped mode Edge waves known as the driving mechanism of beach cusp. In order to track the temporal and spatial variation trends of beach cusp, we quantify the beach cusp in terms of its wave length and amplitude detected by threshold crossing method. In doing so, we also utilize the spectral analysis method and its associated spectral mean sand wave number. From repeated period of convergence and ensuing splitting of sand waves detected from the yearly time series of spectral mean sand wave number of beach cusp, it is shown that the grand circulation process of beach cusp at Mang-Bang beach are occurring twice from 2017. 4. 26 to 2018. 4. 20. For the case of beach area, it increased by $14,142m^2$ during this period, and the shore-line advanced by 18 m at the northen and southern parts of the Mang-Bang beach whereas the shore-line advanced by 2.4 m at the central parts of Mang-Bang beach. It is also worthy of note that the beach area rapidly increased by $30,345m^2$ from 2017.11.26. to 2017.12.22. which can be attributed to the nature of coming waves. During this period, mild swells of long period were prevailing, and their angle of attack were next to zero. These characteristics of waves imply that the main transport mode of sediment would be the cross-shore. Considering the facts that self-healing capacity of natural beaches is realized via the cross-shore sediment once temporarily eroded. it can be easily deduced that the sediment carried by the boundary layer streaming toward the shore under mild swells which normally incident toward the Mang-Bang beach makes the beach area rapidly increase from 2017.11.26. to 2017.12.22.

Virtual Analysis of District Heating System Using ENetPLAN (EnetPLAN을 이용한 지역난방시스템 가상 운전 분석)

  • Ahn, Jeongjin;Lee, Minkyung;Kim, Laehyun
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.18-25
    • /
    • 2019
  • In this study, in order to solve the problem of the program of calculating code input by experienced users in the power generation, the wide area energy network research group developed the local heating operation analysis program EntPLAN, which can be easily used by anyone, including scalability, with domestic technology. Therefore, the Commission intended to compare the heat sources, heat demand, and the results of operation of the combined heat plant (CHP) on the energy network through simulation with the EnetPLAN and the program A on the market. The results showed that the heat and power output on the energy network of the EnetPLAN and A programs were mostly similar in pattern in the simulation results of the heat supply and the operation method of the accumulator. This enabled the application of the simulation for the various operation modes of the cogeneration facilities existing on the energy network. It is expected that EntPLAN, which was developed with domestic technology, will be easily applied in the field in the future and will present efficient operation simulation results.

Development of Piezoelectric Transformer Using The Single Crystal of LiTaO3 (LiTaO3 단결정을 사용한 압전변압기의 개발)

  • Hwang, Sung-Phil;Kim, Moo-Joon;Ha, Kang-Lyeol;Kang, Gab-Joong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.132-137
    • /
    • 2002
  • The single crystal of $LiTaO_3$ ($x-112^{\circ}$ y) has very stable thermal characteristics in a piezoelectric transformer. In this paper, a piezoelectric transformer made of the crystal is newly designed and its operating characteristics are analyzed. The length of the transformer is determined as twice as its width for Lame'-mode because the single crystal of $LiTaO_3$ has low electro-acoustic efficiency. The electric and vibrational characteristics of the transformer is simulated by the PSpice program, and its results are compared to experimental ones. As the results, the ratio of output voltage to input shows large than 10 at 290.83[kHz], which is the frequency coupled the 2nd harmonic for length and the fundamental for width of the Lame'-mode transformer.

Activation Conditions of Sprinkler Head Considering Fire Growth Scenario (화재성장시나리오에 따른 스프링클러 헤드의 작동조건)

  • Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • The aim of this study is to investigate the gas temperature and velocity during sprinkler activation considering the fire growth scenario based on the thermal response model of the sprinkler. The fire source is assumed to have time square fire growth scenarios with a maximum heat release rate of 3 MW. Eight types of standard and fast-response sprinkler heads with an operating temperature range of 65-105 ℃ and a response time index range of 25-171 m1/2s1/2 were adopted. The temperature difference between the gas stream and the sensing element of the sprinkler head decreased as the fire growth slowed down, and the RTI value decreased. The overall gas temperature and velocity conditions predicted using the FDS model at sprinkler activation were in reasonable agreement with those of standard test conditions of the sprinkler head response. However, the sprinkler head could be activated at lower limits of gas temperature and velocity under the current test conditions for a slowly growing fire scenario.

Effect of Hydrogen Recirculation on the Performance of Polymer Electrolyte Membrane Fuel Cell with Dead Ended Mode (Dead ended 모드에서 수소 재순환이 고분자전해질연료전지의 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Korean Chemical Engineering Research
    • /
    • v.57 no.4
    • /
    • pp.531-538
    • /
    • 2019
  • As the performance of PEMFC has been improved, the water and heat generated by reaction have increased so, the water and heat management of PEMFC is becoming more important. In this study, hydrogen recirculation was applied as the water management technique and the effect of recirculation flow rate, purge interval and duration on the performance of PEMFC was investigated. Anode pressure, fuel humidity and utilization, water discharge amount was measured to check the effect of purge conditions on performance. As the recirculation flow rate has increased, the performance of PEMFC became lower due to decrease of anode outlet pressure. According to the purge conditions, instantaneous voltage drop has occurred because of accumulated water. In frequent purge conditions, the performance of PEMFC gradually decreased due to fuel humidity control failure. Stable performance and high fuel utilization was achieved on this work by analyzing the effect of purge conditions.

Properties of Au Clusters Supported on $TiO_2$ Studied by XPS, ISS, AES, and TPD (XPS, ISS, AES, TPD를 이용한 $TiO_2$ 위에 지지된 Au 클러스터의 특성 연구)

  • Kim, Dae Young
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.6
    • /
    • pp.607-617
    • /
    • 1998
  • Au was dosed on $TiO_2(001)$ film grown epitaxially on Mo(100) surface in about 90 ${\AA}$ thickness. The growth mode of Au, thermal behavior and stability of the Au clusters, and the binding energy shift of Au 4f with the change in the amount of Au loading were studied by Auger Electron Spectroscopy (AES), Temperature Programmed Desorption (TPD) spectroscopy, Ion Scattering Spectroscopy (ISS), and X-ray Photoelectron Spectroscopy (XPS). Au grows three dimensionally on $TiO_2(001)$ film and the average size of Au clusters prepared at low temperature is smaller than those at higher temperature and the size increases with temperature irreversibly. Au clusters on $TiO_2(001)/Mo(100)$ start evaporation at 1000 K. TPD spectra of Au show very asymmetric peaks with the same leading edges irrespective of the amount of Au loading. The temperature at the peak maximum increases with the amount of Au. The desorption energy of Au obtained from the leading edge analysis of the TPD spectra is about 50 kcal/mol. The initial sticking coefficient of Au on $TiO_2(001)$ is constant in the temperature range of 200-600 K. The binding energy of Au 4f for the Au loaded on the film less than 2.0 MLE shifts to higher energy compared with the bulk Au. The shift is +0.3 eV at 0.1 MLE Au amount.

  • PDF

Effect of the HVAC Conditions on the Smoke Ventilation Performance and Habitability for a Main Control Room Fire in Nuclear Power Plant (원자력발전소 주제어실 화재 시 공조모드가 배연성능 및 거주성에 미치는 영향 분석)

  • Kim, Beom-Gyu;Lim, Heok-Soon;Lee, Young-Seung;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.74-81
    • /
    • 2016
  • This study evaluated the habitability of operators for main control room fires in nuclear power plants. Fire modeling (FDS v.6.0) was utilized for a fire safety assessment so that it could determine the performance of the smoke ventilation and operator habitability with the main control room. For this study, it categorized fire scenarios into three cases depending on the conditions in the HVAC system. As a result of fire modelling, it showed that Case 1 (with HVAC) would give rise to the worst situation associated with the absolute temperature, radiative heat flux, optical density, and smoke layer height as deliberating the habitability and smoke ventilation. On the other hand, it showed that Cases 2 (w/o HVAC) and 3 can maintain much safer situations than Case 1. In the case of temperature at 820 s, Cases 2 and 3 were up to approximately 63% greater than Case 1 in the wake of ignition. In addition, the influence of radiative heat flux of Case 1 was even larger than Cases 2 and 3. That is, the radiative heat fluxes of Cases 2 and 3 were approximately 68% higher than Case 1. Furthermore, when it comes to considering the optical density, Case 1 was approximately 93% greater than Cases 2 and 3. Accordingly, it expected that the HVAC system can influence a the performance on the smoke ventilation that can be sustainable for operator habitability. On the other hand, it revealed an inconsecutive pattern for the smoke layer height of Cases 2 and 3 because supply vents and exhaust vents were installed within the same surface.