• 제목/요약/키워드: 열흡수율

검색결과 4건 처리시간 0.019초

화력발전소 보일러내의 열전달에 관한 연구 (A Study on the Heat Transfer in boiler through the performance test in thermal power plant)

  • 권영수;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2064-2069
    • /
    • 2004
  • The main reason to analyze heat transfer in boiler inside through the performance test in fossil power plant is to increase plant high efficiency and energy saving movement in the government. Tins study intends to have trend and analyze the boiler heat transfer through the performance test, so it may give us the heat distribution in boiler inside in super-critical and sub-critica1 pressure type power plant

  • PDF

870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰 (A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler)

  • 우광윤;김수석;박인찬;함영준;이응윤
    • 플랜트 저널
    • /
    • 제13권2호
    • /
    • pp.46-51
    • /
    • 2017
  • 본 연구에서는 정격출력 870MW, 대향류 석탄보일러의 최상부층 버너운전에 따른 보일러 연소상태 변화와 보일러 효율을 측정하였다. 시험방법은 하부와 중간층 버너가 운전중인 상태에서 최상부층 전방버너, 전,후방 버너 동시 운전, 후방 버너 운전으로 구분하여 최상부층 버너 운전에 따른 보일러 효율을 측정하였으며 시험 결과 최상부층 전 후방 버너 동시운전 > 최상부층 전방 버너 > 최상부층 후방 버너 운전의 순으로 보일러 효율이 높게 나타났다. 최상부층 전방과 후방 버너를 동시에 운전할 경우 보일러 노 내 열흡수율 증가 및 대류전열면 좌우 증기온도 편차가 감소되었다. 보일러 열흡수율 개선에 따라 보일러 배기가스손실 감소 및 석탄공급량이 후방버너 운전 대비 8t/h 감소하였으며, 이는 연료비 절감은 물론 온실가스 배출량 감축에도 크게 기여할 것으로 판단된다.

  • PDF

PCM물질을 적용한 자연대류형 방열기의 방열특성에 관한 실험적 연구 (An Experimental Study on the Heat Dissipation Characteristics of the Natural Convection Type Radiator by using the PCMs)

  • 성대훈;김민준;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1155-1160
    • /
    • 2008
  • In the present study investigated the heat dissipation characteristics of the natural convection type radiator by using the latent heat from a solid-liquid PCM(Phase Change Material). Total radiator volume size is $423{\times}295{\times}83\;mm$ and PCM tank size is $398{\times}270{\times}26\;mm$. The objective was elapsed time lower than maximum operating temperature. Experimental condition, in order to study the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, and heat of fusion temperature of two type PCMs. For the above experimental conditions, the cooling performance by using the latent heat showed that heat absorption rate performs for about 3 hours from using PCM $38^{\circ}C$. However, cooling performance by using PCM $50^{\circ}C$ showed higher than surface temperature of heater block because of heat of fusion.

  • PDF

PCM을 적용한 자연대류형 수냉식 방열기의 냉각특성에 관한 실험적 연구 (An Experimental Study on the Cooling Characteristics of the Liquid Cooling Radiator of the Natural Convection Type by Using the PCM)

  • 성대훈;김종하;윤재호;김우승;백종현
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.324-329
    • /
    • 2008
  • The liquid cooling effect of a natural convection type radiator by using the PCM has been investigated experimentally. The radiator size is $423{\times}295{\times}83$ mm and PCM container size is $398{\times}270{\times}26$ mm. The objective is elapsed time higher than maximum time to reach for maximum operating temperature of a general liquid cooling radiator. This study, in order to study on the effects of the phase-change phenomenon, carried out the various mass flow rate, input electric power, ambient and melting point of three type PCM. For the above experimental parameter, the melting time was performed about 180/250/560 min at input power 150 W and ambient $30^{\circ}C$ from using the three type PCM(PCM_S1/S2/S3) respectively. Furthermore, the effects of the thermal dissipation was decreased higher input power than lower input power at heating block and melting time of PCM. However, the effects of mass flow rate did not nearly affect of the thermal performance especially.

  • PDF