• 제목/요약/키워드: 열회수보일러

검색결과 48건 처리시간 0.019초

다단 물유동층 열교환기에 의한 보일러 배가스의 폐열 회수 성능에 관한 연구 (A Study on the Heat Recovery from Boiler Exhaust Gas with Multi-stage Water-fluidized-bed Heat Exchanger)

  • 김대기;박상일;김한덕
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1776-1783
    • /
    • 2001
  • Heat recovery from boiler exhaust gas with multi-stage water-fluidized-bed heat exchanger is analyzed in this study. The recovered energy here is not only sensible heat but also latent heat contained in the exhaust gas. In this system direct contact heat transfer occurs while exhaust gas passes through water bed and the thermal energy recovered this way is again delivered to the water circulating through heat exchanging pipes within the bed. Thus the thermal energy of exhaust gas can be recovered as a clean hot water. A computer program developed in this study can predict the heat transfer performance of the system. The results of experiments performed in this study agree well with the calculated ones. The heat and mass transfer coefficients can be fecund through these experiments. The performance increases as the number of stage increases. However at large number of stages the increasing rate becomes very low.

배열회수보일러 복수예열기 부식 파손 분석 (Corrosion Failure Analysis of Condensate Pre-Heater in Heat Recovery Steam Generator)

  • 채호병;김우철;김희산;김정구;김경민;이수열
    • Corrosion Science and Technology
    • /
    • 제20권2호
    • /
    • pp.69-76
    • /
    • 2021
  • In this work, we have performed a corrosion failure analysis of a leaking tube connected to an upper header of a condensate pre-heater in a heat recovery steam generator. It was revealed that the leakage position in the tube was the location where the materials were easily vulnerable due to tensile residual stresses induced by the material manufacturing process and welding process. In addition to an imbalance in the module induced by temperature difference during operation of the pre-heater, the weight of the modules and thermal fatigue provoked a type of stress of tensile-tensile fatigue on the tube. Thus, the leakage position of the pre-heater was exposed to the tensile stress on the inner surface of the tube facing the gas, which rendered the unstable oxide layer susceptible to corrosion and the formation of pits on the water side. The cracks propagated along with the degraded microstructure in a transgranular cracking mode under fatigue loading and finally resulted in water leakage.

지역난방용 중온수 열원 유기랭킨사이클 성능 특성 (Performance Characteristics of Organic Rankine Cycles Using Medium Temperature District Heating Water as Heat Source)

  • 박우진;유호선
    • 플랜트 저널
    • /
    • 제12권1호
    • /
    • pp.29-36
    • /
    • 2016
  • 최근 늘어가는 에너지 수요를 화석연료에만 의존 할 수 없게 되면서 대체 에너지의 중요성이 대두되고 있으며, 이러한 상황에서 유기랭킨 사이클(Organic Rankine Cycle, 이하 ORC)등 산업체 폐열, 태양열, 지열, 해수 온도차 등의 저등급 에너지를 효과적으로 활용하기 위한 많은 연구가 진행되고 있다. 본 연구에서는 지역난방 축열시 회수수를 혼합하지 않고 ORC를 이용하여 하부사이클을 구성하여 성능해석 상용프로그램으로 작동유체 및 운전특성을 예측하였다. 지역난방수 운전조건인 열원 온도 $120^{\circ}C$, 열원 유량 $163m^3/h$(회수수 유량을 고려한 값)로 하고 이 온도에 적합한 다수의 작동유체를 선정하여 성능해석을 수행하였으며, 최고의 성능이 나타난 R245fa의 경우 269.2kW출력과 6.37%효율을 얻을 수 있었다. 또한 ORC 시스템의 응축기 압력변화에 따라 지역난방 회수수 온도가 $57.3{\sim}85^{\circ}C$범위에 형성됨으로서 보일러 입구온도상승에 따른 연료 절감 효과가 예상되었다.

  • PDF

지역난방 배열 회수 보일러의 유동 가속 부식 원인 고찰 (Flow-Accelerated Corrosion Analysis for Heat Recovery Steam Generator in District Heating System)

  • 홍민기;채호병;김영수;송민지;조정민;김우철;하태백;이수열
    • 한국재료학회지
    • /
    • 제29권1호
    • /
    • pp.11-15
    • /
    • 2019
  • Severe wall thinning is found on the tube of a low-pressure evaporator(LPEVA) module that is used for a heat recovery steam generator(HRSG) of a district heating system. Since wall thinning can lead to sudden failure or accidents that lead to shutdown of the operation, it is very important to investigate the main mechanism of the wall thinning. In this study, corrosion analysis associated with a typical flow-accelerated corrosion(FAC) is performed using the corroded tube connected to an upper header of the LPEVA. To investigate factors triggering the FAC, the morphology, composition, and phase of the corroded product of the tube are examined using optical microscopy, scanning electron microscopy combined with energy dispersive spectroscopy, and x-ray diffraction. The results show that the thinnest part of the tube is in the region where gas directly contacts, revealing the typical orange peel type of morphology frequently found in the FAC. The discovery of oxide scales containing phosphate indicates that phosphate corrosion is the main mechanism that weakens the stability of the protective magnetite film and the FAC accelerates the corrosion by generating the orange peel type of morphology.

배열회수보일러 고압 슈퍼히터 튜브 열화도 평가 (Degradation Evaluation of High-Pressure Superheater Tube in Heat Recovery Steam Generator)

  • 송민지;최가현;채호병;김우철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.130-137
    • /
    • 2022
  • In this work, the degradation of high-pressure superheater tubes exposed to the flame of a duct burner in a heat recovery steam generator of a district heating system was evaluated. To assess the deterioration of the used superheater tube, the microstructure, microhardness, and tensile properties were investigated by comparison to an unused tube. The study found that a fin bound at the outer surface of the used tube became fragile only in the location facing the flame. This indicates that the tube was directly exposed to the flame from the duct burner or underwent abnormal overheating. While the unused tube showed a uniform value in hardness and equiaxial grain structure, the used tube revealed a decrease in hardness up to 105 HV and an increase in grain size with a plate-like morphology in the location facing the flame. The coarsening of the grain structure by the flame weakened the mechanical properties of yield strength, tensile strength, and elongation.

산업단지 내 CHP Hybrid System 최적화 모델에 관한 연구 (Optimization Process Models of Gas Combined Cycle CHP Using Renewable Energy Hybrid System in Industrial Complex)

  • 오광민;김래현
    • 에너지공학
    • /
    • 제28권3호
    • /
    • pp.65-79
    • /
    • 2019
  • 본 연구는 산업단지 내 Gas Combined Cycle CHP와 연계 가능한 신재생에너지원을 조합하여 최적의 설비용량을 산정하고자 하였다. 특히 2013~2016년도 에너지사용계획 협의 대상 산업단지 중 집단에너지 공급대상 지역지정 연료사용량 요건은 연간 3.8만 TOE로 미달되지만, 열밀도가 $92.6Gcal/km^2{\cdot}h$로 높은 세종첨단일반산업단지를 연구 대상으로 하였다. 그리고 신재생에너지 Hybrid System 경제성 분석 프로그램인 HOMER Pro를 이용하여 연료전지와 태양광발전을 연계한 FC-PV Hybrid CHP System의 최적화 운영 모델에 대해 분석하였다. 또 CHP의 주 공급 에너지원인 열에너지에 있어, 열수요량 뿐만 아니라 우점 업종에 대한 열수요 패턴을 분석하여 연구의 신뢰도를 높이고자 하였으며, 경제성 분석을 추가하여 상대적 편익을 비교하고자 하였다. 연구 결과, 신규 조성 중인 세종첨단일반산업단지의 전체 간접열 수요는 연간 378,282 Gcal이며, 이중 제지업종이 연간 293,754 Gcal인 약 77.7%를 우점하고 있었다. 산업단지 전체 간접열 수요에 대해 단일 Combined Cycle CHP의 최적 설비용량은 30,000 kW로, 이때 열생산은 CHP가 275,707 Gcal, 72.8 %를 분담하고, 첨두부하보일러 PLB가 103,240 Gcal, 27.2 %를 분담하는 것으로 분석되었다. 그리고 CHP와 연료전지, 태양광 조합에서는 최적 설비용량이 각 30,000 kW, 5,000 kW, 1,980 kW이며, 이때 열생산은 Combined Cycle CHP가 275,940 Gcal, 72.8%, 연료전지가 12,390 Gcal, 3.3%, PLB가 90,620 Gcal, 23.9%를 분담하였다. 여기서 CHP 용량이 감소하지 않은 것은, CHP 용량 감소에 따른 부족한 열 생산량에 대해 PLB의 과다한 운전이 요구되는 경제적이지 못한 대안이 도출되었기 때문이었다. 한편 우점 업종인 제지업종의 간접열 수요에 대해서는 Combined Cycle CHP, 연료전지, 태양광 조합의 최적 설비용량은 25,000 kW, 5,000 kW, 2,000 kW로, 이때 열생산은 CHP 225,053 Gcal, 76.5%, 연료전지 11,215 Gcal, 3.8%, PLB가 58,012 Gcal, 19.7%를 분담하는 것으로 분석되었다. 그러나, 현행 전력시장 및 가스시장에서의 경제성 분석결과는 모두 투자비 회수가 불가능한 것으로 확인 되었다. 다만, 우점 업종인 제지 업종만을 대상으로 CHP와 연료전지, 태양광을 조합한 CHP Hybrid System이 단일 CHP System에 대해 연간 약 93억원의 경영여건을 개선시킬 수 있음을 확인하였다.

CO2 수송선 저장탱크의 BOG 측정 실험 및 회수에 관한 연구 (A Study on the Experimental Measurements and Its Recovery for the Rate of Boil-Off Gas from the Storage Tank of the CO2 Transport Ship)

  • 박진우;김동선;고민수;조정호
    • 청정기술
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2014
  • 화석연료로부터 에너지를 얻을 때, 연소반응에 의해 이산화탄소가 생성되어 진다. 이렇게 이산화탄소의 배출이 늘어나게 되면 지구온난화 문제가 더욱 심각해지게 된다. 따라서 이를 방지하기 위한 이산화탄소 포집 및 저장기술(carbon capture and storage, CCS) 개발이 요구되고 있다. 하지만 액화 이산화탄소를 수송 시 여러 문제로 인해 지속적으로 BOG (boil-off gas)가 발생하게 된다. 본 연구에서는 $40m^3$저장 탱크 2대에 액화 이산화탄소를 주입하여 압력변화 및 외부열과 선적, 하역 시 발생하는 BOG의 양과 조성을 30일 간 측정하였다. 측정한 결과 16,040 kg의 BOG가 발생하였으며, 조성은 $CO_2$ 99.95%, $N_2$ 0.05%인 것을 알 수 있었다. 또한 상용성 모사기인 PRO/II with PROVISION 9.2를 이용하여 발생한 BOG를 증기 재압축 냉동사이클을 통해 재액화 하는 전산모사를 수행하였다. 그 결과 냉동사이클의 총 순환유량은 42.07 kg/h, 응축기 설비의 소모량은 48.85 kg/h가 나오는 것을 알 수 있었다.

열교환 단일 원관의 양력과 항력 변동에 따른 PSD 특성 연구 (The Power Spectral Density Characteristics of Lift and Drag Fluctuation on a Heat Exchanger Circular Tube)

  • 하지수
    • 한국가스학회지
    • /
    • 제19권4호
    • /
    • pp.35-40
    • /
    • 2015
  • 열교환기의 전열관군은 전열관군 외부로 흐르는 유동에 의해 유동 유발 진동이 일어나며 이것으로 말미암아 전열관군에서 파손을 야기할 수 있어서 열교환기의 구조적 안정성을 위해 열교환기의 전열관군에서 유동 유발 진동 특성을 규명할 필요가 있다. 일반적인 열교환기 전열관군에서 유동 유발 진동에 관한 실험적 연구는 기존에 많이 진행되어 오고 있으며 유동 유발 진동에 대한 무차원 PSD(Power Spectral Density) 함수를 무차원 주파수인 Strouhal 수, fU/U의 함수로 도출된 실험적 결과들이 도출되어 있다. 본 연구는 열교환기 단일 원관에서 유동 유발 진동에 관한 기존의 연구들의 결과를 전산유체해석을 통해 검증하고 배열회수 보일러의 전열관군의 유동 유발 진동 특성에 적용하기 위한 기반을 마련하는 것을 목적으로 한다. 이러한 것을 위해 단일 원관에서 비정상 상태 유동해석을 수행하여 주기적인 와동 발생 특성과 원관에서의 양력과 항력의 변화 특성을 살펴보았다. 또한 원관에서 양력과 항력의 변동 특성으로부터 유동 유발 진동에 따른 PSD 특성 결과를 도출하여 기존의 연구들과 비교를 통해 원관 주위의 PSD 특성을 살펴보았으며 양력과 항력의 진폭과 주파수의 특성을 규명하였다.