• Title/Summary/Keyword: 열환경 변화

Search Result 1,254, Processing Time 0.034 seconds

Simulation for the Estimation of Design Parameters in an Aquifer Thermal Energy Storage (ATES) Utilization System Model (대수층 축열 에너지(ATES) 활용 시스템 모델의 설계인자 추정을 위한 시뮬레이션)

  • Shim Byoung-Ohan
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.54-61
    • /
    • 2005
  • An aquifer thermal energy storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop the ATES system which has certain hydrogeological characteristics, understanding the thermohydraulic process of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermohydraulic transfer for heat storage was simulated according to two sets of simple pumping and waste water reinjection scenarios of groundwater heat pump system operation in a two-layered aquifer model. In the first set of the scenarios, the movement of the thermal front and groundwater level was simulated by changing the locations of injection and pumping wells in a seasonal cycle. However, in the second set the simulation was performed in the state of fixing the locations of pumping and injection wells. After 365 days simulation period, the shape of temperature distribution was highly dependent on the injected water temperature and the distance from the injection well. A small temperature change appeared on the surface compared to other simulated temperature distributions of 30 and 50 m depths. The porosity and groundwater flow characteristics of each layer sensitively affected the heat transfer. The groundwater levels and temperature changes in injection and pumping wells were monitored and the thermal interference between the wells was analyzed to test the effectiveness of the heat pump operation method applied.

핵융합로 부품에 대한 고열유속 시험조건 결정

  • Bae, Yeong-Deok;Lee, Dong-Won;Kim, Seok-Gwon;Yun, Jae-Seong;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.273-273
    • /
    • 2010
  • 고열부하 환경에 노출되는 핵융합로의 플라즈마 대향부품은 주로 낮은 원자번호 물질-열전도가 좋은 물질-구조체의 순으로 다층 구조를 이루고 있으며, 이들 간의 우수한 접합성은 부품의 성능을 좌우하는 핵심 요소이다. 이러한 플라즈마 대향부품의 건전성을 평가하기 위해서는 고열속의 열부하를 반복적으로 인가하는 시험이 요구되며, 이를 위해 본 연구원에서는 KoHLT-1, 2의 시험시설을 운용하고 있다. 본 시설에서는 열부하원으로서 그라파이터 히터를 사용하며, 히터는 두 개의 시험 대상부품 사이에 설치되고, 히터에 고전류를 인가하여 복사열에 의해 시험 부품에 열부하를 가하게 된다. 고열부하 환경에서 열피로 시험을 위해 히터에 인가되는 전류를 시간에 따라 일정한 패턴으로 반복적으로 ON-OFF 하게 된다. 본 논문에서는 이러한 고열부하시험을 수행함에 있어 고려해야 할 여러 가지 요소에 대해 논의하였다. 우선 인가하는 열유속(heat flux) 값은 일차적으로 시험시설의 최대 출력에 의해 좌우되며, 시험대상물의 운전조건 및 열부하 반복횟수에 의해 결정된다. 열부하 반복횟수는 주어진 열유속 값에 대해 total strain이 파단에 이르는 수준에 의해 결정된다. 열부하를 인가하는 시간은 히터에 전류를 인가했을 때 요구되는 온도로 상승하는 데 걸리는 시간과 시험대상물의 온도가 더 이상 증가하지 않는데 걸리는 시간에 의해 좌우된다. 냉각시간은 길수록 시험대상물의 온도가 냉각수의 온도에 접근하게 되나 너무 길어지면 시험시간이 급격히 증가하게 되므로, 온도 감소 곡선을 검토하여 적절한 시간을 정하게 된다. 열유속 측정은 냉각수의 온도 상승값과 유량으로부터 계산하게 되며, 정확한 측정을 위해서는 열부하를 인가하는 시간이 충분히 길어야 한다. 또한 시험대상 부품에서 열부하가 인가되는 면적을 정확히 정의해야 하며, 냉각관로에 열부하가 인가되어서는 않된다. 또한 시험대상부품을 지지하는 지지구조체를 통한 열손실을 최소화해야 정확한 열유속을 측정할 수 있다. 시험대상부품을 설치할 때 히터와의 간격 또한 결정해야 할 중요한 요소이며, 간격이 좁을수록 최대 열유속 값을 증가시킬 수 있으나, 너무 가까운 경우 히터의 열변형에 의한 접촉 및 아크 방전의 가능성이 있으며, 이 경우 히터와 시험대상부품의 손상을 가져오게 된다. 시험대상물이 국제열핵융합로(ITER)의 일차벽과 같이 베릴륨이 포함되어 있는 경우 방전에 의한 손상은 인체에 유해한 오염의 원인이 될 수 있다. 또한 순간적인 방전은 고가의 고전류전원의 고장을 유발할 수도 있다. 열부하 시험 중 시험대상물의 온도를 정확히 측정하는 것은 필수적이며, 온도 변화 곡선으로부터 시험대상물의 건전성 여부를 판단할 수 있다. 이를 위해 변화를 가장 잘 탐지 할 수 있는 위치에 온도 센서를 설치하는 것이 관건이며, 이는 사전 분석을 통해 알 수 있다.

  • PDF

On-orbit Thermal Environment Characteristic according to Launch Time of CubeSat STEP Cube Lab-II (초소형위성 STEP Cube Lab-II의 발사시간 변화에 따른 궤도 열환경 특성 분석)

  • Son, Min-Young;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.5
    • /
    • pp.89-97
    • /
    • 2021
  • STEP Cube Lab-II (Cube Laboratory for Space Technology Experimental Project-II) is a 6U Cube satellite equipped with optical and infrared cameras for monitoring Mt. Paektu volcanic eruption signs and earth observation in the Korean peninsula. To guarantee successful mission operation of the cube satellite in orbit, thermal design is essential for the electronic equipment, and must be kept within the allowable temperature range during the mission period. Thus, it is necessary to analyze the predictable orbital thermal environment. The STEP Cube Lab-II is launched through the KSLV-II, however, the operation orbit has not been determined due to the unknown launch time. In this study, we performed a thermal analysis of the satellite and investigated the heat flux according to launch time to analyze the worst orbital conditions that could occur.

Analysis of Thermal Environment Impact by Layout Type of Apartment Complexes for Carbon Neutrality Net-Zero: Based on CFD Simulation (공동주택단지 배치유형별 열환경 영향성 분석: 유체역학 시뮬레이션을 기반으로)

  • Gunwon Lee;Youngtae Cho
    • Land and Housing Review
    • /
    • v.14 no.3
    • /
    • pp.93-106
    • /
    • 2023
  • This study attempted to simulate changes in the thermal environment according to the type of apartment complex in Korea using CFD techniques and evaluate the thermal environment by type of apartment. First, apartment complex types in the 2000s and 2010s were referred from previous studies and four types of apartment complex were extracted from. Second, the layout of the apartment complex and temperature changes were analyzed by the direction of wind inflow. Third, a standardized model was created from each type using tower type, plate type, and mixed driving. Last, CFD simulations were performed by setting up the inflow of wind from a total of eight directions. The temperature was relatively low in the type consisting of only the tower type and the type of placing the tower type in the center of the complex, regardless of the direction of the wind. It was due to the good inflow of wind from these types to the inside of the complex. It can be interpreted because wind flows easily into the complex in these types. The findings showed that wind flow and resulting temperature distribution patterns differed depending on the building type and complex layout type, confirming the need for careful consideration of the complex layout in the early design stage. The results are expected to be used as basic data for creating a sustainable residential environment in the early design stage of apartment complexes in the future.

Thermal Deformation Characteristics of the Adaptive Machine Tools under Change of Thermal Environment (열적 환경변화에 의한 공작기계의 구조적 특성)

  • 이재종;이찬홍;최대봉;박현구
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.1023-1027
    • /
    • 2000
  • In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to analyze the thermal characteristics under several operating conditions, experiments performed with the touch probe unit and five gap sensors on the vertical and horizontal machining centers.

  • PDF

A Study on the Temperature Variation Rate and Temperature Controlling Effect of Parks and Rivers in a City (도시 내 공원과 하천의 기온변화율과 기온완화효과에 관한 연구)

  • Lee, Kang-Guk;Kim, Tae-Woo;Seo, Won-Duck;Hong, Won-Hwa
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.3-9
    • /
    • 2011
  • For urban development, natural covering area such as urban green or river is more rapidly reducing than artificial surface covering area like concrete or asphalt, so thermal environment in a city is being drastically deteriorated. Recently, since people recognize the importance of parks or rivers in a city which play roles as an environmental buffer in it, many studies and policies consider how to improve the life quality of citizens and urban environment. This study aims to examine the status of thermal environment variation in the parks and rivers of the city which is the subject of this research and provide foundational data for urban environment plans through research on temperature variation rate and temperature controlling effect.

Thermal Fatigue Failure of Solder Joints in Electronic Systems (미세솔더접속부의 열피로파단)

  • 박화순
    • Journal of Welding and Joining
    • /
    • v.13 no.4
    • /
    • pp.7-13
    • /
    • 1995
  • 마이크로솔더링에 의한 전자기기는, 사회기능의 중추가 되는 컴퓨터, 통신 기기, 항공기 인공위성 등의 제어계를 구성하므로, 그 접속부에 대한 높은 신뢰성의 요구는 그 무엇보다 중요하다. 전자기기에 있어서의 솔더 접속부는 집과 기판의 전기 적.기계적 접속의 역할을 하고 있으며, 따라서 개개의 접속부의 파단은 전체의 불량 으로 연결된다. 실제 전자콤포넌트와 그 시스템의 단선 등의 사고에 있어서 자주 발생 하는 사고중의 하나가 솔더접속부의 단선에 의한 것이며, 그 단선중에서도 가장 보편 적이며 또한 대단히 심각한 문제로서 주목을 받고 있는 것이 솔더접속부의 열피로파단 이다. 전자기기를 사용할 때, 스위치의 on-off에 의한 power cycle과 환경의 온도변화 에 기인하는 반복열 사이클은 솔더접속부의 피로를 일으키게 되고, 결국에는 사용중에 파단을 초래하게 된다. 이러한 온도변화의 범위는 약 -55.deg. - 150.deg.C로 예상할 수 있으며, 여기서 최고온도인 150.deg.C는 Pb-Sn 공정합금의 경우 0.9Tm.p.이상의 고온에 해당한다. 이 피로는 등온적으로 또는 열사이클중에 발생하기도 한다. 솔더접 속부의 열피로수명은 대부분의 공업재료에서 나타나는 저사이클피로거동과 유사하게 발생하며, 솔더 접속부에 인가되는 열변형/응력(thermal strain/stress)의 크기에 크게 의존하는 것으로 알려져 있다. 솔더는 서로 다른 열팽창계수를 갖는 칩과 회로 기관의 두종류의 재료를 접속하기 때문에, 상기한 바와 같은 반복열사이클에 의하여 발생하는 열변형/응력이 접속부의 피로.파단을 야기시킨다. 이러한 솔더접속부에 대한 주기적인 응력/변형의 인가는 접속부에 내.외적으로 현저한 변화를 야기시키게 되고, 열피로로 연결되며 결국에는 시스템의 전기적 단선을 초래하게 된다. 또한 열피로파단 현상는 변형/응력의 크기 뿐 만아니라 솔더합금자체의 야금학적인 물성에도 크게 의존 하며, 내적.외적인 열변화에 의한 야금학적인 특성변화도 크게 영향을 미친다. 솔더 접속부의 신뢰성에 대한 연구는, 그 중요성에 비추어 볼 때, 지금까지 수많은 연구가 행하여져 왔다. 그러나 신뢰성과 관련된 열피로파단현상에 대한 야금학적인 면에서의 연구는 비교적 적은 편이다. 따라서 본 해설에서는 전자기기의 마이크로 솔더접속부 에서 발생하는 열피로파단현상에 대한 야금학적인 면에 중점을 두어 서술하고자 한다.

  • PDF

Adaptability of an Evaporative Cooling System to the Weather Conditions in Korea (지역별 기상조건에 따른 증발냉각시스템의 적용성)

  • 남상운;김문기
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.11-15
    • /
    • 1998
  • 증발냉각시스템의 원리는 물이 수증기로 상태변화할 때 필요한 기화열을 주변으로부터 공급받으면서 공기의 온도가 감소하는 것이다. 이것은 덥고 건조한 지역에서는 매우 효과적이지만 상대습도가 높은 지역에서는 냉방효과가 낮다. 따라서 국내의 모든지역에 증발냉각시스템의 적용이 적합한지는 의문이다. (중략)

  • PDF