• Title/Summary/Keyword: 열화시험

Search Result 679, Processing Time 0.035 seconds

Improvement of duty rate of Meteor Burst communication with Buried Antenna (매설형 안테나를 이용한 유성 버스트 통신의 도통율 개선)

  • 김병철;이영철;김기채
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.254-260
    • /
    • 1999
  • Meteor Burst Communication can provide effective and economical means of communication where long distance VHF NLOS data transmission is needed; often ranges more than 1000 km. It has been, however, so far considered unsuitable for short distance application because of phenomenal decrease in burst durations, which leads to decreation of total duty rate of the system. This paper extensively analyzes characteristics of shot distance MB(Meteor Burst) path and shows the low duty rate may be improved by increasing burst rate through adapting antenna beam width to cover entire hot-spot region in the space and, by compensating effective burst length through cutting down man-made noises introduced by antenna. Based on the analysis, we are developed a small-opening-cavity antenna, especially designed for short distance MB path. In operation, the antenna is to be buried under ground surface so as to improve directivity and reduces noise introduction. The antenna exhibits power gain of 3 dB with 90 degree beam width and thus enables to illuminate entire hot-spot regions with the elevation angle of 8-90 degree which is the case of transmission less than 100 km. Directivity horizontal to earth surface is suppressed to minimum which enables to cut man-made noises from near-by sources down to more than 3 dB from the level reported with conventional 4 element Yagi. A series of experiments performed on 100 km MB paths have conformed that, with the antenna installed at receiving site, the burst rate and duration time have been noticed to increase by 10 and 20 percent respectively from the values obtained by conventional 4-element Yagi antenna under same testing condition.

  • PDF

Verification of the Viability of Equipotential Switching Direct Current Potential Drop Method for Piping Wall Loss Monitoring with Signal Sensitivity Analysis (등전위 교번식 직류전위차법의 신호 정밀도 검증을 통한 배관 감육 진단 기술에의 적용성 검증)

  • Ryu, Kyung-Ha;Hwang, Il-Soon;Kim, Ji-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.191-198
    • /
    • 2008
  • Flow accelerated corrosion (FAC) phenomenon of low alloy carbon steels in nuclear power plant has been known as one of major degradation mechanisms. It has a potential to cause nuclear pipe rupture accident which may directly impact on the plant reliability and safety. Recently, the equipotential switching direct current potential drop (ES-DCPD) method has been developed, by the present authors, as a method to monitor wall loss in a piping. This method can rapidly monitor the thinning of piping, utilizing either the wide range monitoring (WiRM) or the narrow range monitoring (NaRM) technique. WiRM is a method to monitor wide range of straight piping, whereas NaRM focuses significantly on a narrow range such as an elbow. WiRM and NaRM can improve the reliability of the current FAC screening method that is based on computer modeling on fluid flow conditions. In this paper, the measurements by ES-DCPD are performed with signal sensitivity analyses in the laboratory environment for extended period and showed the viability of ES-DCPD for real plant applications.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

Quality Grading of Concrete Soil Erosion Control Dam in the Aspect of Unconfined Concrete Strength by Surface-Wave Technique (표면파 기법에 의한 콘크리트 사방댐의 콘크리트 강도 등급 평가)

  • Lee, Chang-Woo;Joh, Sung-Ho;Park, Ki-Hyung;Kim, Min-Sik;Yoon, Ho-Joong;Raja Ahmad, Raja Hassanul
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.412-425
    • /
    • 2012
  • Concrete Soil Erosion Control Dam, which blocks flow of debris flow in torrential stream, are reported to lose expected functions due to structural failure and collapses, caused by poor construction, material deterioration and external impacts. In this paper, an integrity assessment technique for debris barriers was proposed, which allows preliminary detection of problems inherent in debris barriers. The proposed integrity assessment technique is a non-destructive method based on SASW method, one of surface-wave tests. In this paper, a practical procedure and analysis guidelines in applying the SASW technique to debris barrier was proposed and its validity was verified using five decrepit debris barriers older than 20-year old. As a result, the SASW method was validated for the reliable grade evaluation method for concrete soil erosion control dam, and the resulting grades turned out to agree with the results determined by Sabang Associations.

Damage Characteristics of Korean Traditional Textiles by Nitrogen Dioxide (NO2) Concentrations (이산화질소(NO2) 농도에 따른 전통직물의 손상 특성)

  • Kim, Myoung Nam;Lim, Bo A;Kim, Seojin;Lee, Sun Myung
    • Journal of Conservation Science
    • /
    • v.29 no.3
    • /
    • pp.197-207
    • /
    • 2013
  • The gas acceleration test was conducted to identify the deterioration of Korean traditional textiles caused by $NO_2$. Total 20 specimens were prepared using 4 different materials (silk, cotton, ramie, hemp) after dyeing with 5 colors (undyed, red, yellow, blue, black). The specimens were exposed to 0.01, 0.1, 1, 10, 100, and 1000 ppm $NO_2$ gas in the test chamber at $20^{\circ}C$, 50% RH for 1 day. Optical, chemical, and physical evaluation was carried out after the exposure. In the case of Korean traditional textile, color difference increased at 1 ppm/day, $NO_3{^-}$ concentration, carbonyl and C-$NO_2$ functional group increased while pH decreased at 10 ppm/day and tensile strength weakened at 100 ppm/day. when it comes to undyed textile, alteration of color difference on silk and hemp cloth, $NO_3{^-}$ concentration and tensile strength on hemp cloth was remarkable. In addition, color difference on blue and yellow textile, $NO_3{^-}$ concentration increase of yellow textile and tensile strength decrease of hemp cloth & ramie cloth were significant. The results suggest that critical $NO_2$ concentration of optical, chemical, and physical damage on Korean traditional textiles are 1ppm/day, 10 ppm/day, 100 ppm/day respectively.

Resistance to Weathering with Materials for fisheries Facilities 1. Photodegradation Mechanisms of Netting Twines for Fisheries Facilities (수산시설용 재료의 내후성에 관한 연구 1.그물실의 자외선 열화기구)

  • 김태호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.45-53
    • /
    • 2000
  • To analyze the photodegradation mechanism of materials for fisheries facilities which stand for considerable time immediately under or even partly above the water surface, such as cage collar, cage net, stationary fishing gear, egc. after 900 hours exposure, weathering experiments on 3 kinds of netting twines like dyed polyethylene(PE) and nylon, and non-treated high strength PE(Hi-PE) were carried out by using xenon light source. The results obtained are as follows : It was observed by scanning electron micrograph(SEM) that a good protection by pigments was obtained in PE and nylon specimen, while crack was rapidly progressed at the surface of Hi-PE one owing to etching by UVR. There was a little increase in density resulting from reorientation of polymer chain, chain scission, etc. in Hi-PE specimen. A wide angle X-ray diffraction showed that 3 kinds of specimens had no fundamental changes in polymer crystalline structure considering each 2$\theta$ of diffraction peak. Remaining tenacity of netting twines was in order of PE, nylon, and Hi-PE after having been exposed to the effect of 900 hours. PE and nylon treated with stuffs were shown to be more resilient than non-treated Hi-PE as confirmed by SEM.

  • PDF

A Study on the Application Scheme of Fire Identification Considering the Heat Release Rate Characteristics of Inflammable Material (가연물의 발열량 특성을 고려한 화재감식 적용방안에 관한 연구)

  • Kang, Jung-Ki;Oh, Jin-Hee;You, Woo-Jun;Ryou, Hong-Sun;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.52-57
    • /
    • 2014
  • The present study suggests the fundamental method for the prediction time of the fire origin by analyzing the combustion phenomenon of inflammable material in the building structure. The heat release rate (HRR) with time variant is evaluated for the interphone as a inflammable material, which is opted from the fire incidents in the stairwell. the fire dynamics simulator (FDS ver. 6.1) is applied in order to analyze the difference of the smoke inflow time to the downstair from the fire event area with various fire pattern. The results show that the maximum inflow time difference for the case of the interphone made from ABS materials is about 4.93 times with the input conditions of heat flux values and the environment in the FDS for the fixed stairwell which composed of total volume $291.3m^3$, floorage $23.3m^2$ and the height of each floor 2.5 m. This research can be practical information for the application method of simulation scheme with experimental data to the fire Identification.

Natural Dyeing of Hanji with Alnus japonica Fruit Extractive (오리나무 열매 추출물을 이용한 한지의 천연염색)

  • Choi, Tae-Ho;Yoo, Seung-Il;Lee, Sang-Hyun;Jeong, Hee-Won;Yang, Eun-Jung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.414-420
    • /
    • 2009
  • We dyed traditional Korean hand-made papers (Hanji) with colorants extracted from fruits of Alnus japonica to investigate the effect of various dyeing factors (mordant, dye concentration and dyeing assistant) on colors, K/S values and light fastness of the dyed Hanji. The dyed hanji had brown color. The K/S value of dyed Hanji was increased by mordanting with alum and copper acetate. $a^*$ and $b^*$ value of dyed Hanji was decreased slightly by mordanting with alum and Iron(II) chloride. The K/S value and $b^*$ of dyed Hanji increased with increasing concentration of dye, but $L^*$ value of dyed Hanji decreased. The K/S value of dyed Hanji was also increased by fixing agent. When Hanji was mordanted with Iron(II) chloride and was not mordanted, use of fixing agent resulted in greater increase of K/S value. Use of fixing agent resulted in poor light fastness. When fixing agent was used, mordanting with copper acetate resulted in smaller color difference than mordanting with alum after aging test.

A Study on Evaluation System of Track Support Stiffness for Concrete Tracks (콘크리트궤도의 궤도지지강성 평가시스템에 관한 연구)

  • Choi, Jung-Youl;Kim, Man-Hwa;Kim, Hyun-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.535-541
    • /
    • 2020
  • A conventional elastic material replacement and performance evaluation are very complicated and time-consuming, and it is difficult to know when to replace the elastic material in advance. By comparing with the product limit and the functional limit, the necessity of elastic material replacement and the improvement of track support stiffness according to replacement can be immediately demonstrated based on experimental data. Using an evaluation system of track support stiffness, the performance evaluation data for elastic materials obtained through field tests using software for track support stiffness is integrated and managed on the administrator's computer. Therefore, the replacement plan is established and maintenance history is managed by identifying the replacement time and location of elastic materials. It is possible to evaluate the performance and condition of the elastic material at the various points during the working time of the track inspection and the track performance (track support stiffness) and durability of the elastic material (aging level, spring stiffness variation rate, etc.) at the operation condition. The elastic material could be replaced timely, and the deterioration of the elastic material can be continuously monitored.

Effects of the High Shear Rate Processing on the Thermal Properties of PC/ABS Blends (고속 전단 가공에 의한 PC/ABS 블렌드의 열적 물성 변화 연구)

  • Lee, Hyeong Il;Lee, Han Ki;Kim, Dea Sik;Choi, Seok Jin;Kim, Seon Hong;Yoo, Jea Jung;Yong, Da Kyoung;Lee, Seung Goo;Lee, Kee Yoon
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.320-326
    • /
    • 2014
  • The effects of high shear rate processing on the thermal properties of PC/ABS blends were studied. It was executed by the high shear processing machine (NHSS2-28) at the varied conditions of screw speeds and loaded duration. After the samples were processed with NHSS2-28, the $T_gs$ were shifted from 143 to $133^{\circ}C$, and the behavior of degradation determined by TGA showed two distinct steps before high shear rate processing, while it showed a straight line after the processing. In order to provide the reasons of the properties, it was showen by SEM and UTM that the droplet sizes morphologically decreased after the processing, and the elongations decreased slightly until 1000 rpm of screw speed and then sharply decreased, according to the conditions of high shear rate processing. Therefore, it can be confirmed that $T_g,s$ of PC/ABS blends were considerably shifted under an appropriate high shear rate condition, and rapidly dropped, so that blends degraded above the condition, due to stress-induced degradation.