• Title/Summary/Keyword: 열화성능

Search Result 1,270, Processing Time 0.032 seconds

A Study on Performance Requirement of I/Q Impairments for RF Implementation in W-CDMA User Equipment (W-CDMA 사용자장치 RF 구현을 위한 I/Q 열화성능요구규격 연구)

  • Lee, Il-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.148-154
    • /
    • 2005
  • This paper deals with performance degradations caused by RF I/Q impairments such as amplitude mismatch and phase mismatch in W-CDMA user equipment which uses QPSK(Quadrature Phase Shift Keying) modulation. The impacts of I/Q impairments on the BER(Bit Error Rate) are analyzed by using the variations of adjacent symbol distance. The BER versus amplitude mismatch and phase mismatch with QPSK constellation is reviewed through Matlab simulation. Performance degradation produced by RF I/Q impairments is measured with the implemented RF transceiver and modulation/demodulation test equipments through EVM(Error Vector Magnitude). The minimum performance requirements of amplitude mismatch and phase mismatch in W-CDMA user equipment are presented from the point of hardware implementation and the test method of the impairments is also included.

엔진유의 마모방지성능에 미치는 하이드로퍼옥사이드의 영향

  • 문우식
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1991.11a
    • /
    • pp.8-13
    • /
    • 1991
  • 엔진유는 엔진내에서 사용됨에 다라 마모방지제의 소모, 브로바이 가스의 혼입, 열화생성물과 첨가제간의 반응등의 영향을 받아 서서히 열화되기 시작하며, 아울러 마모방지성능 또한 변화되어간다. 열화생성물 중의 어떤 극성산화물이나 고분자생성물은 엔진마모의 감소에 기여하나, 일부 산성생성물은 부식마모를 일으킬 수도 있으며, 엔진내에서 발생되는 마모분중에는 어브레시브 마모를 발생시키는 것도 있다. 또한, 브로바이 생성물중에는 마찰면을 직접 부식시키는 성분도 있으며, 그외 부식성이 약한 브로바이 성분들도 첨가제와의 반응을 통하여 간접적으로 엔진유의 마모방지성능에 영향을 미친다. 필자는 최근의 연구에서 엔진유의 마모방지성능은 엔진에서의 열화정도에 달 현격히 변화하며, 또한 사용유의 전산가증가치와 마모량간에는 명확한 상관관계가 있다는 것을 보고한 바 있다. 본보고에서도 사용유에 함유되어 있는 성분중 마모방지성능에 크게 영향을 미치는 하이드로퍼옥사이드를 선택하여, 그 함유유인 모델열화유로 윤활하는 마모시험을 수행하여 얻은 결과에 관하여 검토하고자 한다.

  • PDF

Performance change of Polymer electrode Membrane operating temperature (PEMFC 고분자 전해질막의 운전온도에 따른 성능변화)

  • Lee, Ho;Shin, Kang-Sup;Park, Kwon-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.180-182
    • /
    • 2007
  • PEMFC의 상용화 진입에 있어서 걸림돌 중의 하나가 열화(degradation)에 의한 성능감소이다. PEMFC 고분자 막의 열화가 PEMFC 성능 감소에 많은 영향을 미친다. 고분자 막의 성능 감소 원인은 여러가지가 있지만 무가습/OCV조건에서 성능 감소가 잘 된다. 그 이유에 대해서는 OCV/무가습 조건에서 과산화수소나 라디칼이 많이 형성될 수 있다는 것과, OCV조건에서 사용되지 못하는 수소와 산소의 gas-crossover 가 많기 때문이라는 것 그리고 무가습 조건에서 수소와 산소의 분압이 높아 gas-crossover 가 유리하고 악의 건조에 따른 물리적인 영향 등등이 거론되고 있다. 본 연구에서는 같은 조건에서 Cell 운전온도가 막열화에 미치는 영향을 실험하였다. OCV 여려 조건 에서 단위전지 실험을 한 후 I-V, 수소 투과도, 임피던스, FER(fluoride emission rate)등을 측정해 그 결과를 검토 분석하였다. OCV/Anode 무가습 조건이 알려진 대로 막열화 가속조건 이었음을 확인하였고, 실험 결과 Cell 운전온도가 $10^{\circ}C$증가 할 때마다 FER(fluroide emission rate)이 즉 막 열화속도가 약 2배정도 증가함을 보였다.

  • PDF

Performance Assessment of Deteriorated Reinforced Concrete Bridge Columns (열화된 철근콘크리트 교각의 성능평가)

  • Kim, Tae-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.45-54
    • /
    • 2011
  • This paper presents a nonlinear finite element analysis procedure for the performance assessment of deteriorated reinforced concrete bridge columns. A computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), was used to analyze these reinforced concrete structures. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. Advanced deteriorated material models are developed to predict behaviors of deteriorated reinforced concrete bridge columns. The proposed numerical method for the performance of damaged reinforced concrete bridge columns is verified by comparison with reliable experimental results.

Correlation Filter Based Thermal Object Tracking Using Objectness Feature (객체성 특징을 활용한 Correlation Filter 기반 열화상 객체 추적 기법)

  • Jung, Hyeonseok;Kim, Wonjun
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2019.06a
    • /
    • pp.89-91
    • /
    • 2019
  • 객체 추적 기술은 컴퓨터 비전 분야에서 활발하게 연구되고 있는 분야로, 인간-컴퓨터 상호작용(HCI)이나 로보틱스, 그리고 자율주행 자동차와 같은 곳에 유용하게 사용될 수 있다. 그중에서도 열화상 객체 추적 기술은 빛이 전혀 없는 어두운 밤에도 적용 가능하기 때문에, 감시 시스템이나 사고 현장의 구조 상황, 또는 군사적 응용에 더욱 유용하다. 그러나 일반적으로 열화상 영상은 컬러 영상보다 해상도가 낮고, 객체의 경계가 흐릿하며, 텍스쳐가 거의 없다는 점 때문에 기존 추적 방법들의 성능 저하의 원인이 된다. 이에 본 논문은 기존 Correlation Filter 기반 추적기에 객체성 특징을 함께 이용하여, 열화상 영상에서의 객체 추적 성능을 향상 시키는 방법을 제안하였다. 또한 실험을 통해 기존 방법보다 열화상 영상에서의 객체 추적 성능이 향상된 것을 보였다.

  • PDF

Deterioration Diagnosis of Surface and Coating Layer for Maintenance Managements of the Membrane Structure (막구조 건축물의 유지관리를 위한 표면 및 코팅층의 열화 진단)

  • Kang, Joo-Won;Lee, Seung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.97-104
    • /
    • 2011
  • This paper contains of descriptions of deterioration diagnosis of the surface and a coating layer for maintenance managements of large spatial structures with membrane structure. Membrane is a roofing material of the structures that its performance of durability including its performance of chemical resistance and corrosive resistance is considered to be highly important. In general, the items of diagnosis for maintenance managements such as membrane extensively include the diagnosis of deterioration of the membrane surface, of a coating layer of membrane, the diagnosis of deterioration between a coating layer and fiber, of overall surface of membrane, of the class of ropes, of reinforced belts, and of the cover of rubber. The object of this study that needs maintenance managements of the membrane with PVC and FIFE which are commonly used and shows the diagnosis results of deterioration of the surface and a coating layer.

Evaluation of Long Term Performance of 154kV Polymer Insulators (154kV 고분자 애자의 장기 성능평가)

  • Lim, Yun-Seog;Won, Kyung-Bae;Lee, Sang-Yoon;Choi, In-Hyuk;Shin, Koo-Yong;An, Ho-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.547-548
    • /
    • 2011
  • 본 논문에서는 한국전력공사에서 장기열화 시험을 수행한 154kV 고분자애자의 성능평가를 수행하고 그 결과를 1999년부터 2008년까지 한국전력공사154kV 송전선로에 시범 설치한 고분자애자의 주간코로나, 열화상 측정을 시행하고 제조회사/규격별 각 24련을 발취하여 총 168련에 대하여 한전 표준구매 규격에 따른 각종 시험을 수행하고 현 성능상태를 검증하였으며 이를 토대로 잔존 수명을 예측하고자 하였다. 대부분의 애자가 양호한 성능을 보이고 있으나 일부 애자에서는 부적합 결과를 보였으며 수명의 경우, 초기 품질계수 정보 부족 및 중간열화 상태의 데이터 부족으로 정확한 잔존수명 예측 데이터를 얻기에는 부족했으며 추가적인 가속열화시험 등의 데이터를 확보해야 할 것으로 사료된다.

  • PDF

A Study on the Improvement Method of Performance Degradation due to Symbol Timing Offset Between Transceiver Symbols in DOCSIS3.1 FDX System in Frequency Domain (주파수 영역에서 DOCSIS3.1 FDX 시스템의 상하향 신호간 심볼 타이밍 옵셋으로 인한 성능 열화 개선 방법에 관한 연구)

  • Ryu, Kwanwoong;Jung, Joon-Young;Im, Han-Jae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.07a
    • /
    • pp.579-581
    • /
    • 2020
  • 최근 DOCSIS 3.1 시스템에서 주파수 이용효율향상을 위해 상향과 하향 신호를 동일대역으로 동시전송하는 DOCSIS3.1 FDX 시스템이 연구되고 있다. 동일대역을 사용할 경우 DOCSIS 3.1 FDX시스템의 하향 송신신호는 높은 전력을 가진 신호로 feedback되어 상향송신기로부터 전송된 낮은 전력의 상향 수신신호와 결합하여 상향수신기에 수신되어진다. 이러한 결합신호는 상향신호와 하향신호간의 심볼타이밍 옵셋이 정확하게 일치하지 않으면 상향신호 성능을 열화시키는 원인이 된다. 본 논문에서는 이러한 문제를 해결하기 위해 주파수영역에서 DOCSIS 3.1 FDX시스템의 상하향신호간 심볼 타이밍 옵셋으로 인한 성능 열화 개선 알고리즘을 제시하고 모의실험을 통해 성능열화를 개선할 수 있음을 보인다.

  • PDF

일본에 있어서 전력기기의 절연진단기술

  • 마스우라겐지
    • 전기의세계
    • /
    • v.45 no.4
    • /
    • pp.30-35
    • /
    • 1996
  • 일본에서는 경제의 고도 성장기인 1960년대에서 1970년대의 중반에 걸쳐서 대량의 전력설비가 설치되고 1980년대에 들어서는 보다 고도의 기술을 이용한 고성능의 대용량 전력기기.시스템이 도입되어 현재에 이르고 있다. 일본의 9개 전력회사의 수요 최대 전력은 1995년 여름에 약 1억 6천만 kW에 달하였다. 이와 같이 대용량에서 고성능의 전력설비를 고신뢰도로 효율 좋게 운용하기 위해서 일본에서는 다음과 같이 중점을 두고 전력설비의 절연진단기술의 개발을 행해 오고 있다. 1) 절연열화기구의 해명과 열화판정기준의 명확화 2) 절연진단계측에 있어서 노이즈의 저감과 제거 3) 절연열화진단의 on-line화 4) 절연잔존수명추정법의 개발 5) 절연진단에 컴퓨터 AI의 이용 절연진단은 그림 1에 나타낸 바와 같이 전력설비의 예방보전 중의 일부분으로서 위치하고 있다. 그림 1에 있어서 전력설비의 절연체에 가해지는 전기적, 열.기계적, 환경적 스트레스의 종류와 크기, 또 그것들에 의한 절연열화의 양상은 전력설비의 종류 즉 회전기, 정지기, 선로 각각에 따라 다르다. 따라서 다음에 전력설비의 종류별로 일본에 있어서 절연열화 진단기술의 현황과 연구개발 동향을 소개한다.

  • PDF

Resistance to Freezing and Thawing of Concrete Subjected to Carbonation (탄산화를 받은 콘크리트의 동결융해 저항성)

  • Lee, Seung-Tae;Park, Kwang-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.623-631
    • /
    • 2018
  • In this study, the degree of deterioration of concrete was investigated in the laboratory under conditions of carbonation and freeze-thaw cycling, which are the major causes of the deterioration of its performance. In this test, the carbonated concrete was subjected to combined freeze-thaw deterioration tests for up to 300 cycles, and its dynamic elastic modulus and compressive strength were measured. The evaluation of the effect of the water-binder ratio on normal concrete subjected to combined carbonization and freezing-thawing showed that its resistibility against such combined deterioration decreased more rapidly in the concrete with a water-binder ratio of 55 % compared with that having a water-binder ratio of 35 %. In the case where the concrete was blended with a mineral admixture consisting of fly ash and blast furnace slag at the same water-binder ratio, it showed an increase of its resistibility against combined deterioration.