• Title/Summary/Keyword: 열화상 형광체

Search Result 3, Processing Time 0.02 seconds

Study on Temperature Field Measurement of Fluid using Phophor Particle (Sr,Mg)2SiO4:Eu2+ (인광입자(Sr,Mg)2SiO4:Eu2+를 이용한 액체의 온도장 측정에 관한 연구)

  • Song, Dong Jin;Lee, Hyunchang
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.3
    • /
    • pp.59-65
    • /
    • 2019
  • Phosphor particles ((Sr,Mg)2 SiO4:Eu2+ were suspended in deionized water in quartz cuvette and used for measuring liquid temperature field by using two-color-ratio method. In the temperature range of 23~77℃, it showed the relative error from 2.4% to 4% and the temperature sensitivity of 0.65 %/℃ at 30℃ and 0.95 %/℃ at 77 ℃. This performance is comparable to measurement techniques using thermographic liquid crystal or laser induced fluorescence or other thermographic phosphor particle. Among investigated potential error sources, the particle number density affected the intensity ratio and the temperature, but the effect of laser fluence was not evident.

Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera (CCD 카메라를 이용한 열화상 실시간 추정과 화재경보)

  • Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.92-98
    • /
    • 2016
  • This study evaluated thermal image real-time estimation and fire alarm using by a CCD camera, which has been a seamless feature-point analysis method, according to the angle and position and image fusion by a vector coordinate point set-up of equal shape. The system has higher accuracy, fixing data value of temperature sensing and fire image of 0~255, and sensor output-value of 0~5,000. The operation time of a flame specimen within 500 m, 1000 m, and 1500 m from the test report specimen took 7 s, 26 s, and 62 s, respectively, and image creation was proven. A diagnosis of fire accident was designated to 3 steps: Caution/Alarm/Fire. Therefore, a series of process and the transmission of SNS were identified. A light bulb and fluorescent bulb were also tested for a false alarm test, but no false alarm occurred. The possibility that an unwanted alarm will be reduced was verified through a forecast of the fire progress or real-time estimation of a thermal image by the change in the image of a time-based flame and an analysis of the diffusion velocity.

Reference white setting based on brightness of CPT and resolution (수상관의 밝기 및 해상도를 고려한 기준 백색 설정)

  • 최덕규;김주동;권기룡;안상호;이건일;송규익
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.2
    • /
    • pp.334-343
    • /
    • 1997
  • Reference white in color television receiver can be achieved by adjusting the RGB gun current ratio and it is necessary to provide additional gain ratio adjustment for the RGB video signal. Generally, the gun current density profile has a gaussian distribution and the gain-bandwidth product of RGB channel amplifieris constant. Therefore brightness and spatial resolution are changed with variations in reference white of receiver. In this paper, the effect of RGB gun current and channel gain ratios on brightness and resolution of CPT is analyzed. Brightness is increased with the color temperature of referenc white because of Helmholtz-kohlrausch effect. The change in ligh output is more abrupt and spatial resolution is improved with unity current ratio. For more bright and improved ressolution we also present the range of color temperature of reference white for P22 phosphors.

  • PDF