2단 가열식 지열시스템의 경제성 분석 (An Economic Analysis of a Secondary Waste Heat Recovery Geothermal Heating System)

  • 신정수;김선혜
    • 설비공학논문집
    • /
    • 제29권5호
    • /
    • pp.249-258
    • /
    • 2017
  • This paper provides an economic analysis of a new geothermal heat pump system that reuses condenser waste heat from a Ground Source Heat Pump ($GSHP_{ch}$) to provide energy for a hot water Ground Source heat pump ($GSHP_{hw}$). After conducting feasibility tests using GLD and TRNSYS simulations, the proposed system was effectively installed and thoroughly tested. We observe that 1) the Coefficient of Performance (COP) of the $GSHP_{hw}$ and the $GSHP_{ch}$ during cooling mode improves by up to 62% and 7%, respectively; 2) the number of bore holes can be reduced by two; and 3) the hot water supply temperature of the $GSHP_{hw}$ increases by up to $60^{\circ}C$. We further conclude that 1) the reduction of two bore holes can save approximately ten million Won from the initial cost investment; and 2) the increased COP of the $GSHP_{hw}$ can save approximately one million Won in annual electricity costs.

일본의 $CO_2$ 냉매를 이용한 열펌프급탕기 개발 동향

  • 김만회
    • 대한설비공학회지:설비저널
    • /
    • 제31권7호
    • /
    • pp.65-70
    • /
    • 2002
  • 지구의 오존층을 보호하기 위한 몬트리올 의정서가 1987년 채택된 이후 오존층 파괴물질의 사용이 점차 감소되고 있다. 선진국의 경우 1995년 말부터 CFC냉매의 생산을 전폐하였고, HCFC냉매의 경우는 2020년 전폐를 목표로 대체냉매를 이용한 응용 기술개발 및 제품 생산이 진행되고 있다. 가정용 냉장고 및 차량용 에어컨에는 R-12의 대체냉매로 R-134a가 도입되었으며, 유럽을 중심으로 냉장고에는 HC계 냉매인 R-600a도 대체냉매로 사용되고 있다. 가정용 에어컨에는 혼합냉매인 R-407c 와 R-410a가 R-22 냉매를 대체하여 적용되고 있다. 그러나 현재, CFC및 HCFC 대체 냉매로 많이 사용되고 있는 HFC계 냉매도 지구 온난화 지수가 대단히 큰 문제를 가지고 있다. 1997년 채택된 교토의 정서에는 HFC계 냉매가 온실효과가 가스 배출규제물질에 포함되어 있다. 이에 따라서 오존층의 파괴지수가 영이고 지구온난화지수도 거의 없는 자연냉매가 주목을 받게 되었으며, 자연 냉매의 하나인 이산화탄소 ($CO_2$R744) 냉매의 응용기술 및 제품개발 연구가 선진국을 중심으로 폭넓게 진행되고 잇다. 본고에서는 $CO_2$냉매의 일반적인 특성을 간단히 소개하고 일본에서 진행되고 있는 $CO_2$냉매를 적용한 급탕시스템의 제품개발 및 시장현황에 대해서 기술하기로 한다.

  • PDF

지중열 이동 시뮬레이션을 이용한 수평형 지열시스템의 채열성능 예측 (Prediction of the Heat Exchange Rate for a Horizontal Ground Heat Pump System Using a Ground Heat Transfer Simulation)

  • 남유진;채호병
    • 설비공학논문집
    • /
    • 제25권6호
    • /
    • pp.297-302
    • /
    • 2013
  • The ground source heat pump (GSHP) system has attracted attention, because of its stability of heat production, and the high efficiency of the system. However, there are few studies on the prediction method of the heat exchange rate for a horizontal GSHP system. In this research, in order to predict the performance of a horizontal GSHP system, coupled simulation with a ground heat transfer model and a heat exchanger circulation model was developed, and calculation of heat exchange rate was conducted by the developed tool. In order to optimally design the horizontal GSHP system, the flow rate of circulation water, and the depth and buried spaces of heat exchangers were considered by the case study. As a result, the temperature of circulation water and the heat exchange rate of the system were calculated in each case.

100RT급 하수열원 냉난방시스템 적용 (Application for Heating and Cooling System Using Sewage Water)

  • 장기창;윤형기;박성룡;백영진;나호상;신광호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.215-220
    • /
    • 2006
  • Along with socioeconomic development and improving standard of living, the heat demand for heating and cooling in residential and commercial sectors is expected to expand rapidly, reaching over 43 million TOE by 2010 in Korea(about 80% increase compared with that in 1995). Since most of this heat demand is loop temperature below $60^{\circ}C$, the utilization of 'unused energy' is surely one of very effective measures to both environmental preservation and energy conservation. 'Unused energy' in this paper is implicated as 'temperature differential energy' available from treated sewage water, useful and abundant heat source for heat pump(cooler in summer and warmer in winter than outside air). An analysis was carried out to estimate the energy potential of treated sewage water for heat pump heat source. Some analysis were taken to study the characteristics of a heat pump system using the treated sewage water as heat source.

  • PDF

열(熱)펌프시스템에서 각종(各種) 설계인자(設計因子)들에 따른 응축기(凝縮器)의 최적설계(最的設計)에 관한 연구(硏究) (A Study on the Optimization of Condenser according to Design Factors in Heat Pump System)

  • 이영수;김남국
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.408-417
    • /
    • 1988
  • This study optimized the condenser dimension of heat pump system with the heat sources which are solar irradiation and ambient air. At first, the author selected the principal design factors influencing the performance of heat pump system. And the author considered the variation of condenser dimension according to the variation of the selected design factors, that is, ambient air temperature, condenser temperature, degree of superheating, degree of sub-cooling and irradiation. As a result this study, among refrigerants R12, R22 and R500, refrigerant R22 has more heating output than R12 and R500, and the coefficient of performance on this heat pump system is not greatly influenced by the degree of superheating and degree of sub cooling. The ambient air temperature is below $5^{\circ}C$ at balance point and the optimal tube length of condenser dimension is about 3.8 m. Also the author gained the optimal design diagram for the optimization of condenser dimension according to various design factors.

  • PDF

육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석 (Thermal load analysis of tank culture system for applying seawater source heat pump)

  • 윤민기;김태훈;정석권
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.

가스엔진용 유기랭킨사이클의 설계 및 제작 (Design and Construction of a Bottoming Organic Rankine Cycle System for an Natural Gas Engine)

  • 이민석;백승동;성태홍;김현동;채정민;조영아;김형태;김경천
    • 한국가스학회지
    • /
    • 제20권6호
    • /
    • pp.65-72
    • /
    • 2016
  • 천연가스용으로 개조된 가스엔진에서 방출되는 폐열을 활용하기 위한 유기 랭킨사이클 (Organic Rankine Cycle: ORC) 발전시스템을 설계 및 제작하였다. 이 연구에서는 개조된 가스엔진의 폐열을 실험적으로 분석한 데이터를 바탕으로 구성한 ORC 시스템의 컴포넌트를 설계하고 제작하였다. ORC 시스템에는 2개의 판형 열교환기와 5kW급 팽창기, 다단 펌프가 사용되었으며, 전기 히터를 이용하여 ORC 시스템의 열역학적 성능을 분석하였다. 또한, 실제로 가스엔진과 연동하여 작동 특성을 파악하기 위한 실험을 수행하였다. ORC 시스템에 열량을 공급해주는 2대의 가스엔진을 사용하였다. 열원모사실험 결과, 열원온도 $110^{\circ}C$에서 축동력 5.22kW가 발생, 압력비 7.41, 열효율 9.09%가 계산되어졌으며, 엔진연동실험에서는 고온수 온도 $86^{\circ}C$에서 축동력 2kW가 발생, 이 때의 압력비는 3.75, 열효율 6.45%가 계산되었다.

수직밀패형 지중열교환기의 설계인자가 보어홀 전열저항에 미치는 영향에 관한 연구 (A Study on the Effects of Design Parameters of Vertical Ground Heat Exchanger on the Borehole Thermal Resistance)

  • 장근선;김민준
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.128-135
    • /
    • 2018
  • 현재 지열 열펌프 시스템에 수직밀폐형 지중열교환기가 가장 많이 적용되고 있으며, 수직밀폐형 지중열교환기의 성능에 영향을 미치는 주요 인자로는 지중 열전도율(k)과 보어홀 전열저항($R_b$)이 있다. 본 연구에서는 현장에서 측정된 열응답시험 데이터를 이용하여 보어홀 전열저항을 계산하였으며 지중열교환기 개별 설계인자들(순환수유량, 파이프 수, 그라우팅재)이 보어홀 전열저항에 미치는 영향을 분석하였다. 또한 도출된 그라우팅 열저항은 문헌에 제시된 다양한 상관식과 비교 분석하였다. 시험데이터를 통해 본 시험에서의 지중열교환기 보어홀 전열저항은 0.1303 W/m.K로 나타났으며, 보어홀 전열저항에서 그라우트 열저항이 66.6 %, 파이프 열저항이 31.5 %, 순환수 대류열저항이 1.9 %를 차지하여 그라우트가 보어홀 열전달에 가장 큰 영향을 미치는 인자임을 확인하였다. 또한 각 설계인자의 설계변수가 보어홀 전열저항에 미치는 영향을 분석한 결과 실리카샌드를 혼합하여 그라우트 열전도율를 높이는 방법이 파이프 수 증가나 순환수 유량증가보다 열전달 증진에 더 효과적임을 알 수 있었다.

우리나라 지열발전 pilot plant 프로젝트의 발전량 추정 (Estimating generation capacity of geothermal power generation pilot plant project)

  • 송윤호;이태종;윤운상
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.197.1-197.1
    • /
    • 2011
  • 2010년 12월에 착수한 인공 지열 저류층 생성기술(EGS)를 이용한 지열발전 pilot plant 프로젝트에서 계획된 5 km 깊이의 doublet 시스템에서 실현 가능한 발전량 목표를 추정하였다. 지하 5 km 에서의 암반 온도는 경북 포항지역의 평균 지온증가율은 $33^{\circ}C$/km로 하였을 때 지표온도를 감안하면 $180^{\circ}C$로 추정된다. 암반과의 열교환을 통해 생산되는 지열수의 온도를 $160^{\circ}C$, 발전 후 주입수의 온도를 $60^{\circ}C$로 생각할 수 있고, 이때 binary 발전의 열효율은 0.11이 가능하다. 최근의 EGS에서 실현 가능한 생산 유량인 40 kg/sec을 가정한다면 총 발전량은 1.848 MW로 계산되며, 지열수 양수 펌프와 binary 발전의 냉각에너지 소요량을 고려하면 순 발전량 1.5 MW가 가능해진다.

  • PDF

0.4 MW급 분절형 아크 토치에 의한 초음속 공기 플라즈마의 특성 진단 (Characteristics Diagnosis of Supersonic Air Plasma by 0.4 MW Class Segmented Type Arc Torch)

  • 김민호;이미연;최채홍;김정수;서준호;홍봉근
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.194-195
    • /
    • 2013
  • 초음속 공기 플라즈마 환경을 모사할 수 있는 0.4 MW급 Enhanced Huels형 초음속 공기 플라즈마 발생 장비가 2012년에 전북대학교에 설치 완료되었다. 초음속 공기 플라즈마 시험장비는 대기권으로 reentry 할 수 있는 비행체의 열차폐체 시험평가를 주목적으로 개발되었으며, 핵융합장치용 고온 내열체 소재개발에도 활용될 예정이다. 분절형 아크 플라즈마 토치는 전극부식에 의한 오염도를 적으면서 고출력의 안정적인 플라즈마를 발생시키며, 일반적인 직류 토치로는 얻을 수 없는 초고엔탈피 플라즈마 열유동을 얻을 수 있는 특징이 있다. 구축된 장비는 최대 직류 출력 1,200 kW의 DC 전원공급장치, 0.4 MW급의 분절형 아크 플라즈마 토치, ${\phi}1.5m{\times}2m$ 크기의 진공쳄버, 1 MW의 냉각 능력을 갖춘 디퓨저와 열교환기, 진공 용량 $100m^3$/min의 진공펌프 9대, 88 g/s의 공기유량에서 NOx를 50,000 ppm에서 100 ppm으로 저감할 수 있는 후처리 시스템, 4 bar 15 g/s의 공기를 공급할 수 있는 가스 공급장치, 30 bar 600 lpm의 저전도수와 4 bar 560 lpm의 일반수를 공급할 수 있는 냉각수 공급장치로 구성되어 있다. 초음속 공기 플라즈마의 발생 특성을 시험하기 위해 플라즈마 발생 조건으로 토치공급전력 350 kW와 410 kW, 토치 공기 공급 유량 16.3 g/s, 토치 내부압력 3.9~4.2 bar, 챔버압력 40 mbar으로 시험을 수행하였다. 발생된 플라즈마 상태를 진단하기 위해 속도는 쇄기 탐침기, 열유속은 Gardon 게이지, 엔탈피와 토치 효율은 토치의 공급전력과 냉각수에 의한 손실 전력으로 각각 측정하였다.

  • PDF