• 제목/요약/키워드: 열펌프시스템

검색결과 422건 처리시간 0.025초

현장타설형 건물 기초를 이용한 지중열 공조시스템의 성능평가에 관한 연구 (A Study on Development of a Ground-Source Heat Pump System Utilizing Cast-in-place Concrete Pile Foundation of a Building)

  • 황석호;남유진
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.641-647
    • /
    • 2010
  • Ground-source(Geothermal) heat pump(GSHP) systems can achieve a higher coefficient of performance than conventional air-source heat pump(ASHP) systems. However, GSHP systems are not widespread because of their expensive installation costs. The authors have developed a GSHP system that employs the cast-in-place concrete pile foundations of a building as heat exchangers in order to reduce the initial cost. In this system, eight U-tubes are arranged around the surface of a cast-in-place concrete pile foundation. The heat exchange capability of this system, subterranean temperature changes and heat pump performance were investigated in a full-scale experiment. As a result, the average values for heat rejection were 186~201 W/m(per pile, 25 W/m per pair of tubes) while cooling. The average COP of this system was 4.6 while cooling; rendering this system more effective in energy saving terms than the typical ASHP systems.

지열을 이용한 온실용 냉난방시스템 개발 (Development of a Cooling and Heating System for Greenhouse using Geothermal Energy)

  • 이용범;조성인;이재한;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.688-692
    • /
    • 2005
  • Importance of substitute energy has been increasing due to environmental issues and lack of fossil fuels. In addition, heating cost that occupies from 30 to $40\%$ of the total production cost in Korean protected cultivation needs to be reduced for profitability and global competition. But, studying on substitute energy to solve these problems has not been activated for Korean protected cultivation. Therefore, this study was conducted to develop a geothermal heat pump system for cool ing and heat ing of greenhouses at a lower cost than conventional hot air heater and air conditioner. Fundamental test of heat transfer characteristics in soil was conducted by computer simulation and controlled tests for its verification. Based on the results of the theoretical and empirical investigations, an optimum heat pump system was developed and the performance was evaluated for practical use in a greenhouse at the Pusan Horticultural Experiment Station. The system was compared with a conventional hot air heating system through a cucumber growing test and economic feasibility analysis. Results of the application test of the geothermal heat pump showed that with an initial setting of $15^{\circ}C$ the inside temperature of the greenhouse could be maintained between 15 and $17^{\circ}C$. Results of the cucumber growing test showed that there were no significant differences in average height, leaf length, leaf width, number of nods, leaf area, dry weight and yield between the plots wi th the geothermal heat pump system and a conventional hot air heater. Economic feasibility analysis indicated that the variable cost of the hot air heater could be saved $81.2\%$ using the geothermal heat pump system. It was concluded that the geothermal heat pump system might be a pertinent heating and cooling system for greenhouses because of the low operating cost and the use of environment-friendly geothermal energy.

  • PDF

콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석 (The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water)

  • 백남춘;정선영;윤응상;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

지역난방 사용자기계실 내 열수송관 차압을 이용한 발전 및 제어 기술 (Power Generation and Control System Using Differential Pressure of District Heating Pipeline in a Substation)

  • 김경민;박성용;오문세
    • 에너지공학
    • /
    • 제26권3호
    • /
    • pp.90-96
    • /
    • 2017
  • 지역난방 열수송관을 통해 중온수를 공급할 때 고압의 중온수로부터 열사용자 설비(지역난방 열교환기)를 보호하고 온도조절을 원활히 하고 유체의 원거리 공급을 위해 차압유량조절밸브를 통해 압력을 조절하거나 압력을 감소시키고 있다. 하지만, 고압 유체 사용에 따라 압력조절밸브에서 캐비테이션이 발생하여 잦은 고장 및 오작동을 유발하여 많은 문제가 발생하고 있으며, 사업자 및 사용자 모두에게 에너지 손실 및 민원 유발 등의 원인이 되고 있다. 이러한 문제를 해결하기 위해 연구 중인 1차측 차압유량조절밸브를 수력터빈으로 대체하여 차압에너지를 전기에너지로 변환하고, 전기를 2차측 펌프의 동력으로 활용하는 에너지 절감기술을 소개하고자 한다.

냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구 (A study on the solar assisted heating system with refrigerant as working fluid)

  • 김지영;고광수;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

CFD 해석을 이용한 현장 열응답 시험의 출구온도 예측 (The Outlet Temperature Prediction of In-Situ Thermal Response Test using CFD Analysis)

  • 심용섭;이희상
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.28-35
    • /
    • 2016
  • 지열원 히트펌프 시스템에서 지중 열교환기 설계를 위해 수행하는 현장 열응답 시험은 많은 시간과 비용이 수반되기 때문에 조건 변화에 따른 출구온도 예측이 어려운 실정이다. 본 연구에서는 국내에서 주로 사용하는 수직형 지중 열교환기의 열전달 성능을 예측하기 위한 방안으로 3차원 CFD 해석 기법을 제안하고, 2개소의 현장 열응답 시험의 출구온도와 기울기 값을 비교하여 CFD 해석 방법의 신뢰성을 확인하였다. CFD 해석 결과, 2개소의 현장 열응답 시험의 출구온도는 $0.5^{\circ}C$ 이내에서 예측하였고, 기울기 값은 1.6% 이내에서 적절히 예측하였다. 이를 통해 CFD 해석 방법의 신뢰성을 확인하고, 2개소의 현장 열응답 시험의 유량 및 지중 유효 열전도도 조건을 각각 ${\pm}20%$ 변화시키면서 현장 열응답 시험의 출구온도를 예측하였다. 첫 번째 현장(Case 1)의 경우 유량 변화에 따라 $28.0^{\circ}C$(-20%)와 $29.6^{\circ}C$(+20%), 지중 유효 열전도도 변화에 따라 $29.6^{\circ}C$(-20%)와 $28.0^{\circ}C$(+20%)로 현장 열응답 시험의 출구온도를 예측하였으며, 두 번째 현장(Case 2)의 경우 유량 변화에 따라 $28.4^{\circ}C$(-20%)와 $29.8^{\circ}C$(+20%), 지중 유효 열전도도 변화에 따라 $29.7^{\circ}C$(-20%)와 $28.4^{\circ}C$(+20%)로 현장 열응답 시험의 출구온도를 각각 예측하였다.

3관식 시스템 히트펌프의 충전량 변화에 따른 성능 특성에 관한 연구 (The performance of a heat pump with 3-piping system at various charging conditions)

  • 송인식;최종민;주영주;정현준;강훈;김용찬
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.288-293
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

  • PDF

산란계에 적용 가능한 공기-물 히트펌프의 음용수 공급시스템 이용기술에 관한 연구 (Study on the Utilization of Drinking Water Supply System of Air-water Heat Pumps Applicable to Laying Hen)

  • 백이;강석원;장재경;권진경
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.917-923
    • /
    • 2018
  • The drinking water supply system applicable to the laying hen consists of air-water heat pumps, drinking water tanks, heat stroage tank, circulation pumps, PE pipes, nipples, and control panels. When the heat pump system has power of 7.7 to 8.7 kW per hour, the performance coefficient is between 3.1 and 3.5. The supply temperature from the heat pump to the heat stroage tank was stabilized at about $12{\pm}1^{\circ}C$, but the return temperature showed a variation of from 8 to $14^{\circ}C$. Stratified temperature in the storage tank appeared at $12.^{\circ}C$, $13.5^{\circ}C$ and $14.4^{\circ}C$, respectively. The drinking water supply temperature remained set at $15^{\circ}C$ and $25^{\circ}C$, and the conventional tap water showed a variation for $23^{\circ}C$ to $30^{\circ}C$. As chickens grow older, the amount of food intake and drinking water increased. $y=-0.0563x^2+4.7383x+8.743$, $R^2=0.98$ and the feed intake showed $y=-0.1013x^2+8.5611x$. In the future, further studies will need to figure out the cooling effect on heat stress of livestock.

균일 방제를 위한 항공 살포시스템 구현 (Implementation of Aerial Application System for Application Uniformity)

  • 지선호;전부일;조현찬
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.597-604
    • /
    • 2016
  • 본 논문에서는 항공 방제 시 균일 방제를 통하여 병해충에 의한 농산물 생산량 저하 및 농약이 과도 살포된 농작물 생산을 방지하고자 하였다. 항공 방제가 실시되는 비행 고도 3m와 속도 15km/h를 유지하는 것은 사용자의 조종 습관 및 방법, 바람의 변화 같은 환경적 요인이 작용하여 대단히 어렵다. 따라서 무인 헬리콥터로부터 비행 데이터를 전송받아 비행속도 및 고도의 변화에 따라 붐의 각도와 DC 펌프의 제어가 가능하도록 살포 장치 및 제어기를 설계 및 제작하였고 무성항공사의 무인 헬리콥터 Rmax에 탑재하여 살포 성능을 검증했다. 실험은 가로 10m, 세로 50m의 농지에서 감수지를 한 열에 1.25m 간격으로 9장씩 5열을 5m의 위치에서부터 10m 간격으로 배치하고, 방제 실험 시 제작된 항공 살포 시스템을 이용하여 살포하였다. 무인 헬리콥터는 최저속도 7.2km/h부터 최고속도 17.6km/h, 최저높이 2.32m부터 최고 3.47m까지 최고 10.4km/h의 속도 변화와 1.15m 고도 변화를 보이며 비행하였고, 각 열이 평균 46423개의 입자개수의 분포로 7.5m의 유효 살포 영역을 형성함을 보여 제안된 항공 살포시스템이 균일 방제에 효과가 있음을 증명한다.

버즈 두바이 콘크리트 건물의 설계와 시공 (Design and Construction of the Burj Dubai Concrete Building Project)

  • Abdelrazaq, Ahmad
    • 콘크리트학회지
    • /
    • 제20권6호
    • /
    • pp.28-35
    • /
    • 2008
  • 700미터 이상의 높이와 160층 이상으로 설계된 버즈두바이가 완공되면 버즈두바이는 인간이 건축한 건축물 중에서 최고높이의 건축물이 될 것이다. 바람의 동적효과를 완화하고 제어시키는 것이 가장 중요한 설계요소중의 하나이며, 설계초기의 공기역학적 형상과 풍공학에 대한 고려가 이러한 주상복합건물의 건축적 형상 및 디자인에 있어 큰 역할을 하는 반면, 건물의 구조시스템을 위한 재료 선택 또한 디자인의 중요한 요소이고 그 다음으로 세부적인 재료기술에 대한 평가 및 기술자 수급이 요구되어진다. 콘크리트는 콘크리트의 강도, 강성, 감쇠, 잉여력, 형틀성, 내화성, 시공성, 원가 등을 고려하여 선정된다. 이 논문은 콘크리트를 활용한 구조시스템을 적용하면서의 설계적으로 도전되었던 부분과 버즈두바이의 콘크리트공사의 초기계획에 대해 집중적으로 다룰 것이다.