• Title/Summary/Keyword: 열펌프시스템

Search Result 422, Processing Time 0.024 seconds

Performance analysis of dual source heat pump system with single unit dual source evaporator (SUDS증발기를 사용한 2중열원 열펌프의 성능해석)

  • 우정선;이세균;이재효;박효순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

Design and performance analysis of water-to-air heat pump system using double-tube heat exchanger (이중관 열교환기를 사용한 물 대 공기 열펌프 시스템의 설계와 성능해석)

  • Han, D.Y.;Park, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.462-471
    • /
    • 1997
  • The water-to-air heat pump system requires relatively lower energy consumption and less installation space. The heat exchangers used for this system are the finned-tube type for the indoor unit and the double-tube type for the outdoor unit. Mathematical models for this system are developed and programmed in computer. Experimental data from various conditions are obtained and compared with calculated values from the computer simulation program. Differences of cooling capacity and COP are 1.25% and 0.47%, and those of heating capacity and COP are 0.51% and 0.13%, respectively. Simulation results are in good agreement with test results. Therefore, the developed program is effectively used for the design and the performance prediction of water-to-air heat pump system.

  • PDF

열전식 열펌프의 원리와 응용

  • 주해호
    • Journal of the KSME
    • /
    • v.25 no.5
    • /
    • pp.400-405
    • /
    • 1985
  • 펠티어효과가 10여년 전에 발견되었으나 이것을 공학분야에 응용되기 시작한 것은 반도체 재료가 개발되기 시작한 1950년경부터 실용화되기 시작하였다. 이러한 열전식 열펌프를 이용하여 냉 각시스템을 만들 경우 재래식인 기계식 냉동시스템과 비교해 볼 때 여러 가지 장점이 있다. 열전식 냉동방법은 전자가 한 반도체에서 다른 반도체로 이동하면서 그 주위의 열과 함께 이동 하는 원리를 이용한 것이기 때문에 기계식 냉동시스템의 중요한 구성품인 압축기, 증발기, 응 축기, 용매제와 같은 부품이 전혀 필요가 없다. 움직이는 부품이 없기 때문에 소음이 없고 신 뢰성이 높다. 100W 보다 적은 열출력에 대해서는 무게가 적고 부피가 적은 장점이 있다. 또한 습도 제어가 정확하고 전류의 방향만 바꾸워 주면 쉽게 냉동에서 가열로 전환이 된다. 작동습 도범위는 제품에 따라 다르지만 대개 +100.deg.C~ -125.deg. C까지 가능하다. 이러한 장점 때 문에 가장 많이 응용되고 있는 분야는 군사무기인 관성항법유도무기의 전자부품실을 냉각시켜 주는 데 사용되고 그 외에 용도는 다양하다. 본 고에서는 열전식 열펌프의 원리와 그 응용에 대해서 가능한 상세히 설명하여 앞으로 이 분야에 대한 연구에 보템이 되고저 한다.

  • PDF

An Evaluation of Heating Performance of the Heat Pump System Using Wasted Heat from Thermal Effluent for Greenhouse Facilities in Jeju (발전소 온배수 폐열을 이용한 제주 시설온실 냉난방용 열펌프 시스템의 난방성능 평가)

  • Moon, Sungbu;Hyun, Myung-Taek;Heo, Jaehyeok;Lee, Dong-Won;Lee, Yeon-Gun
    • Journal of Energy Engineering
    • /
    • v.28 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • A heat pump system using wasted heat from thermal effluent to supply the heating energy can reduce energy consumption and emissions of greenhouse gases by greenhouse facilities nearby. The Jeju National University consortium constructed a heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO to provide with cool or hot water to greenhouse facilities located 3 km from the power station. In this paper, the system configuration of the heat pump system was summarized, and the results of operations for demonstration of a heating performance carried out during the winter season in 2018 were investigated. The preoperational tests proved that the water temperature drop through the pipeline transporting extracted heat was less than $2^{\circ}C$. The COP (coefficient of performance) of the heat pump was higher than 4.0, and hot water with the maximum temperature of $50^{\circ}C$ could be supplied to greenhouse facilities by utilizing wasted heat from thermal effluent.

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation (가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석)

  • Kim, Min-Sung;Yoon, Seok-Ho;Baik, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1351-1358
    • /
    • 2011
  • To approximate the threshold of the fault detection and diagnosis (FDD) system, validation of the measurements is mandatory. Naturally, the system shows uncertainties due to measuring sensors - mostly thermocouples or RTDs - and due to repeatability. The uncertainty of a thermocouple comes from natural variation or a drift of the thermocouple measurement. Considering the natural variation behaves like zero-mean white noise, its natural variation can be characterized closely by the steady-state standard deviation. However, residuals between measurements and no-fault references in FDD systems show a statistical distribution with various uncertainties. In this paper, steady-state variations of measurement residuals were investigated by utilizing built-in temperature sensors in a heat pump for the model development and the final application.

Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination (실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구)

  • Kwon, Young-Chul;Chun, Chong-Keun;Park, Youn-Chang;Ko, Kok-Won;Seo, Dong-Nam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1487-1493
    • /
    • 2008
  • In order to investigate the cooling capacity of multi-heat pump applying an inverter compressor, the experiment on the cooling performance characteristics of heat pump with 3 indoor units was performed under the cooling standard and cooling low-temperature conditions. The system data were measured by the psychrometric calorimeter. The operation characteristics and the behavior of the cooling cycle of the heat pump with 3 indoor units were understood from the cooling capacity, COP, and P-h diagram by indoor-unit combination. The operating load and performance of the multi-heat pump depends on the indoor-unit combination. The cooling capacity and COP of the low temperature condition were larger than those of the standard one. Also the cycle was analyzed by using P-h diagram.