• Title/Summary/Keyword: 열펌프시스템

Search Result 422, Processing Time 0.032 seconds

Experimental Study on the Performance Characteristics of a Scroll Expander for 1kW-class Organic Rankine Cycle (1kW급 유기랭킨사이클용 스크롤 팽창기의 성능 특성에 관한 실험적 연구)

  • Kim, Dokyun;Yun, Eunkoo;Yoon, Sang Youl;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.41-48
    • /
    • 2015
  • The performance characteristics of a scroll expander is the most important variable for the performance of organic Rankine cycle system. In this paper, the performance characteristics of a scroll expander was identified using 1kW class organic Rankine cycle system with various operating conditions. The ORC system is composed of an evaporator, a scroll expander, a condenser and a working fluid feed pump that uses R245fa as working fluid. The hot water temperature was controlled from $80^{\circ}C$ to $115^{\circ}C$ by the 50kW-class electric water-heater. The maximum isentropic efficiency of the scroll expander was measured about 77%, and the shaft power was measured from 0.5 kW to 1.8 kW according to heat source temperatures.

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency (인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.12
    • /
    • pp.4721-4726
    • /
    • 2010
  • The performance characteristics of water-chilling heat pump using CO2 for the control of inverter frequency was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter flow type heat exchangers with concentric dual tubes, which are made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4m length. The experimental results summarize as the following: for constant inlet temperature of evaporator and gas cooler, as mass flow rate, compression ratio and discharge pressure increases with the inverter frequency. And heating capacity and compressor work increases, but coefficient of performance(COP) decreases with the inverter frequency of compressor. As inlet temperature of secondary fluid in the evaporator increases from $15^{\circ}C$ to $25^{\circ}C$, compression ratio and compressor work decreases, but mass flow rate, heating capacity and COP increases with the inverter frequency of compressor. The above tendency is similar with performance variation with respect to the variation of inverter frequency in the conventional vapor compression refrigeration cycle.

Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System (열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발)

  • Kim H. T.;Choi H. L.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.1 s.108
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

Thermal Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump (열펌프에 의한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • v.26 no.2
    • /
    • pp.155-162
    • /
    • 2001
  • The greenhouse heating system with heat pump was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air and soil and moisture content of soil in the greenhouse were developed, and its validity was justified by actual data. From the analysis of experimentally measured data and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the heating system with heat pump were very much close to the experimental values. 2. In the heating system with heat pump, the expected values of day time surface temperature of soil by computer simulation were very much similar to the measured values, but those of night time were higher than the measured value by at most 2.0$\^{C}$. 3. The simulation model predicted temperature of greenhouse film as of 1$\^{C}$ below than the mean value of ambient air and greenhouse air temperature. 4. Heat loss value of daytime was found to be larger than that of nigh as much as 1.3 to 2.3 times for the heating system with heat pump. 5. In the heating system with heat pump, when the lowest ambient temperature was -8$\^{C}$∼-7$\^{C}$ the air temperature of greenhouse was 5$\^{C}$∼6$\^{C}$, thus the heat pump heating system contributed in greenhouse heating by 13$\^{C}$.

  • PDF

Simulation of aquifer temperature variation in a groundwater source heat pump system with the effect of groundwater flow (지하수 유동 영향에 따른 지하수 이용 열펌프 시스템의 대수층 온도 변화 예측 모델링)

  • Shim, Byoung-Ohan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.701-704
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having influenced by groundwater movement, understanding of thermo hydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.00 1 are shaped circular, and the center is moved less than 5m to the groundwater flow direction in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

A Study on the Noise Reduction of a Portable Fuel Cell System (휴대용 연료전지 시스템의 소음 저감에 대한 연구)

  • Jeon, In-Youl;Bae, Joon-Soo;Oh, Min-Jung;Choi, Sang-Hyeon;Lee, Choong-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.858-861
    • /
    • 2006
  • In this paper, a study on the noise reduction in a mobile fuel cell system is presented. Among various fuel cell systems around 20W capacities designed for mobile electronic devices, the active direct methanol fuel cell (DMFC) systems have been recently developed. In such systems, the primary noise source is the air pump which provides sufficient air flow ($5{\sim}6$ liter/min) for electrochemical reaction with methanol fuel while the noise contributions from other auxiliary parts are relatively small. Especially, the discrete noise tones generated by the air pump are dominant and those frequency peaks related to the rotor harmonics are needed to be suppressed by a silencer. Therefore. the Herschel/Quinke (HQ) tubes, which use the out-of-phase cancellation of acoustic waves propagating through direct and indirect pathways, are applied to the inlet of the air pump. Performance of noise reduction with HQ silencer is analytically estimated by calculating the transmission. The length and number of thin HQ tubes are optimized to decrease the radiated noise. As a result, the sound pressure level could be successfully reduced by about 10 dB after applying three serially connected HQ tubes.

  • PDF

A Study on the Heat Pump-Latent Heat Storage Type (열펌프-잠열축열 온돌 시스템 연구)

  • 송현갑;박문수
    • Journal of Biosystems Engineering
    • /
    • v.26 no.4
    • /
    • pp.385-390
    • /
    • 2001
  • The Ondol system using both air-to-water heat pump and PCM(Phase Change Material) was constructed, and the effects of ambient air temperature on COP(Coefficient of Performance) of heat pump, the amount of heat supplied to the Ondol in the heating process, the heat storage in the PCM and the variation of Ondol room temperature were analyzed. The results from this study could be summarized as follows: 1. The COP of the heat pump (3 PS) was in proportion to the ambient air temperature. 2. When the ambient air temperature was varied between -10$^{\circ}C$ and -7$^{\circ}C$, the air temperature in the Ondol room was maintained between 16$^{\circ}C$ and 22$^{\circ}C$. As the results, it was certified that the heat pump-latent heat storage type Ondol system could be a comfortable residential heating system in the winter. 3. The maximum radiation and convection heat transfer from Ondol surface was 206.2 kJ/㎥hr and 82.6 kJ/㎥hr respectively. As the results, it could be confirmed that the radiation was major heat transfer mechanism for the Ondol room heating.

  • PDF

PVT-GSHP System Economic Evaluation Study with IEA ECBCS Annex 54 Method (IEA ECBCS Annex 54 방법에 근거한 PVT-GSHP 시스템 경제성 평가 연구)

  • Pak, Jin-Woo;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.64-71
    • /
    • 2014
  • This study is to perform economic analysis of a PVT-GSHP (Photovoltaic Thermal-Ground Source Heat Pump) system compared to the conventional system which consists of a boiler and a chiller. This research has simulated, developed and analyzed four systems for application in a residential and an office building which was based on the hourly EPI (Energy Performance Index, $kWh/m^2yr$). Case 1 includes a boiler and a chiller to meet heating and cooling demands for a house. Case 2 is the same conventional system as Case 1 for a office. Case 3 is simple summation of Case 1 and 2. And Case 4 is utilizing a PVT-GSHP to meet the combined loads of the house and office. The economic evaluation study was based on IEA ECBCS Annex 54 subtasks C economic assessment methods. This study indicated that PVT-GSHP system can save a building's energy up to 53.9%. Also the SPB (Simple Payback) of the PVT-GSHP system with 0%, 50% initial incentive was 14.5, 6.7 year respectively.

The Characteristics of Thermal Diffusion With the Vertical-Closed Loop Type Geothermal Heat Exchanger (수직밀폐형 지중열교환기의 온도분포 특성)

  • Sun, Jong-Cheol;Kim, Byung-Chul;Koh, Young-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.57-65
    • /
    • 2013
  • The temperatures with the ground depth, the positions of circulation water in ground heat exchanger were measured and thermal diffusion characteristics with the distances of the direction normal to the borehole was analysed. The deeper the depth of ground, the less the influences of outdoor temperature, but below 10m of ground, there was no influences of ground temperature. When the depth of trench pipe was below the depth of 2m, there was no influence. In the ground of 10m when the distances between the pipe and the other places were above 0.5m, the variations of temperature were less than $1.6^{\circ}C$ and above 2.5m they were less than $0.1^{\circ}C$. When the distances of bore hole were above 5m, there were no. influences of the nearest ground heat exchanger.

Simulation of Solar and Ambient-air-assisted Heat Pump (태양열 및 외기 열원식 히트펌프 시스템 시뮬레이션)

  • Baeck, N.C.;Park, J.U.;Song, B.H.;Lee, J.K.;Kim, H.J.
    • Solar Energy
    • /
    • v.20 no.4
    • /
    • pp.17-24
    • /
    • 2000
  • Thermal performance of a SAAHPS (Solar and Ambient-air-assisted Heat Pump System) located in KIER is simulated with TRNSYS 14.2. The SAAHPS is composed of dual evaorators, each of which is used as a solar fluid heat source and an air fluid heat source. Polynomial coefficients data for the SAAHPS is supplied with Frigosoft, a program widely used for heat pump modeling. In general, collector area and storage volume are 2 key parameters in SAAHPS thermal performance. A parametric study is performed in this study to assess sensitivity of collector area and storage volume in SAAHPS. We concluded that firstly collector area and storage volume are the primary variables in SAAHPS thermal performance, secondly COP of SAAHPS is higher than that of conventional heat pumps. Therefore. collector efficiency can be enhanced swith SAAHPS during a heating season.

  • PDF