• Title/Summary/Keyword: 열펌프시스템

Search Result 422, Processing Time 0.023 seconds

Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System (단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석)

  • Tian, Huaizhang;Park, Seong-Ryong
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

Analysis of Thermodynamic Design Data for Cooling of Double -Effect Absorption System of Solar Energy using LiBr - water and Ethylene Glycol Mixture (흡수액으로 에틸렌글리콜이 혼합되고 태양열을 이용한 이중효용 흡수식 시스템의 냉방 특성해석)

  • Won, Seung-Ho;Park, Sang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.45-54
    • /
    • 2003
  • For cooling of double effect absorption heat pump system of solar heating source, analysis of thermodynamic design data has been done to find the property of Libr-water + ethylene Glycol mixture for working fluid by computer simulation. Derived thermodynamic design data, enthalpy based coefficient of performance and flow ratio for possible combinations of operating temperature for water - LiBr and Ethylene Glycol mixture ($H_2O$ : CHO ratio 10:1 by mole) by computer simulation are done. The obtained results, COP and mass flow ratio of the water - lithium bromide - ethylene glycol system, are compared with data for the water-Libr pair solution.

영광1호기 시뮬레이터 노심모델 및 입력 변환툴 개발

  • 이명수
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.04a
    • /
    • pp.168-173
    • /
    • 2000
  • 지금까지 국내에서 설치되어 있는 원전 시뮬레이터용 노심 (Neutronics) 모델 프로그램은 주로 전산기 성능이 오늘날 비해 낮은 환경에서 실시간으로 노물리 계산을 위해 중성자 확산(Diffusion)현상을 미리 반영한 곡선을 사용하는 등 빠른 계산을 위해 많은 가정과 간략화가 있었다. 본 논문에서는 중성자 물리 계산을 2 Group 3-D로 계산이 가능한 최신의 노심코드(REMARK)를 이용하여, WH사가 공급한 900Mw의 3 Loop PWR인 영광 1호기 12주기를 기준으로 한 시뮬레이터의 노심모델 개발하기 위한 핵설계 전산체계인 APA(ALPHA-PHOENIX-ANC) 시스템의 출력으로부터 자동으로 REMAR 입력데이타를 생성하기 위한 GUI툴 개발과 개발된 노심모델의 자체 검증 및 원자력발전소 사고해석에 쓰이는 최적평가코드(RETRAN)를 기반으로 하는 최신 실시간 열수력 시뷸레이션(ARTS) 모델과 결합(Integration)되어 원자로 냉각재 펌프 1대 정지 및 터빈정지 시험등 과도시험한 결과를 기술하였으며 개발된 노심 모델은 원자력 교육원 2호기 시뮤레이터에 적용될 예정이다.

  • PDF

The Field Test of Heat Pump Cooling & Heating System using the water-purifying device (수도시설을 이용한 지열냉난방시스템의 실증연구)

  • Hwang, Ki-Sup;Jung, Woo-Sung;Ahn, Young-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.629-634
    • /
    • 2007
  • The Alternative energy has lately attracted considerable attention due to the high oil price and environment problem. In this study, field test of facility for using the geothermal energy source from water-purifying device was constructed and monitoring devices are installed to estimate the efficiency of this system. Initial installation cost can be saved efficiently by connecting a heat pump system into the existing pumping well in site of water-purifying in Cheongju. One set of monitoring results during summer was presented and analyzed.

  • PDF

Heating Characteristics of Ondol using Heat Pump-Latent Heat Storage System (열펌프-잠열축열시스템을 이용한 온돌의 난방특성)

  • Kim, M.H.;Song, H.K.
    • Solar Energy
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • In these days the hot water circulating Ondol using the fossil fuel boiler is the heating system for the most of the Korean residents. Then it is installed without the heat storage medium in the Ondol heating layer, but the Korean traditional Ondol had been composed with the heat storage medium. The Ondol room without heat storage medium could not be comfortable because the room air temperature is not only changed unstably but also it has a defect too much fuel consumption. Therefore in this study the heat pump-latent heat storage Ondol as the new type of Ondol system was developed to solve these problems mentioned above, and the COP of the heat pump (Coefficient Of Performance), the latent heat storage characteristics in the new type of Ondol system and the temperature variation in the Ondol room with the ambient temperature were analyzed.

  • PDF

공동주택에 설치된 소화 및 제연시스템에 관한 화재연동 실태분석

  • Gang, Won-Seon;Son, Bong-Se;Jeong, Jong-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.161-162
    • /
    • 2013
  • 최근에 신축되는 주상복합건축물이나 대단위 아파트단지는 지상층에서 보면 각각이 독립되어 있는 별도의 소방대상물로 보이지만, 실제로는 지하층을 통하여 연결된 하나의 소방대상물이다. 이러한 건물의 지하층에서 화재가 발생하면 열이나 연기가 다른 동으로 확산되어 피해가 커질 수 있으며, 특정동의 소방펌프에서 고장이 발생하거나 우발적인 선로합선 등으로 인하여 수신기에 이상이 발생하면 전체 동에 설치된 소방시설이 정상적으로 작동되지 않는 경우가 발생하게 된다. 화재감지기의 신호에 따라 작동되는 제연댐퍼, 준비작동식 스프링 클러설비 등이 수신기에서 연동되는 과정을 인천송도에 위치한 글로벌주상복합 단지를 토대로 하여 소화 및 제연설비의 연동실태를 분석하였다.

  • PDF

A Study on the Energy Storage System Using Air Source Heat Pump for Heating and Cooling (공기 열원을 이용한 축열식 냉난방 시스템 연구)

  • Kim, Ook-Joong;Lee, Kong-Hoon;Seo, Jeong-Kyun
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1125-1130
    • /
    • 2006
  • An air source heat pump system producing the ice and water storage energy for cooling and heating of building has been proposed. Cycle design and simulation considering energy balance between heating and cooling capacity has been carried out. The roles of the capacity controlled compressor, refrigerant heating device and air preheating are investigated in detail. System control logic for meeting the predetermined heating capacity when the system is operated at cold climate condition is suggested. Some anticipated problems of the proposed system are also described.

  • PDF

An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy (신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구)

  • JEONG, SOON YOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.630-636
    • /
    • 2020
  • This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.