• Title/Summary/Keyword: 열전달 강화

Search Result 39, Processing Time 0.027 seconds

Heat Transfer on Secondary Injection Surface in Supersonic Flow-field with Various Injection Angle (초음속 유동장내 2차분사 분사각도 변화에 따른 열전달 특성 변화)

  • Song, Ji-Woon;Yi, Jong-Ju;Cho, Hyung-Hee;Bae, Ju-Chan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.321-325
    • /
    • 2008
  • In this paper, heat transfer changes due to the shock/boundary layer interaction were investigated on surfaces where secondary jet are injected. With an infra-red thermography, surface temperature was measured and the measured data was used to obtain the convective heat transfer. Heat transfer is enhanced with increment of momentum ratio. And normal injection case has a higher heat transfer value than that of 15 degrees inclined injection case. Secondary injection momentum ratio and injection angle affect the surface heat transfer distribution.

  • PDF

Experimental Study of Air Side Pressure Drop and Heat Transfer Characteristics of Enhanced Fin-Tube Heat Exchangers (열전달 촉진 핀-관 열교환기의 공기측 압력강화 및 열전달 특성에 관한 실험)

  • Youn, Baek;Kil, Yong Hyun;Park, Hyun Yeon;Kim, Young Saeng
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1555-1563
    • /
    • 1998
  • Heat transfer and pressure drop for ${\phi}10.07$ dry surface fin-tube heat exchanger with wave and wave-slit fins were measured for different fin spacings and number of tube rows. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of wave fin is 1.5mm. The experiments were performed for 4 different fin spacings, 1.3, 1.5, 1.7 and 2.0mm, and the number of tube rows were 1,2 and 3 rows. The present results were compared with the previous results for the wave depth of 2mm. Also hydrophilic coated and bare fins were tested. Correlations for Colburn j-factor and friction factor were developed.

Numerical Study of the Rib Arrangements for Enhancing Heat Transfer in a Two-pass Channel of Large Aspect Ratio (종횡비가 큰 이차유로에서 냉각성능 향상을 위한 요철배열 연구)

  • Han, Sol;Choi, Seok Min;Sohn, Ho-Seong;Cho, Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.3
    • /
    • pp.161-169
    • /
    • 2017
  • The present study investigated the effect of the rib arrangement and a guide vane for enhancing internal cooling of the blade. Two types of rib arrangements were used in the first and second passage in parallel. Aspect ratio of the channel was 5 and a fixed Reynolds number based on hydraulic diameter was 10,000. The attack angle of rib was $60^{\circ}$, rib pitch-to-height ratio (p/e) was 10, and the rib height-to-hydraulic-diameter ratio ($e/D_h$) was 0.075. The effect of an interaction between Dean vortices and the secondary vortices from the first passage was observed. Overall, the attack angle of rib in the first passage was dominant factor to heat transfer and flow patterns in turning region. Also, the channel with a guide vane showed enhanced heat transfer at the tip surface with reducing flow separation and recirculation.

Heat Transfer Model for Soil Irradiated by Infrared (적외선 조사된 토양에 대한 열전달 모델)

  • 강화석;이귀현;강위수;오재헌
    • Journal of Biosystems Engineering
    • /
    • v.21 no.4
    • /
    • pp.449-455
    • /
    • 1996
  • The temperature distributions at various soil depths were predicted by heat transfer model during and after infrared irradiation on sand loam or loam soil. At each soil depth, predicted and measured temperature distributions were compared with using the mean relative percentage deviation and standard error. The mean relative percentage deviation was less than 10% between predicted and measured temperature distributions at each soil depth. Thus, it was concluded that the temperature distribution at each soil depth could be predicted satisfactorily by heat transfer model. Also, it is expected that these predicted temperature distributions can be used as basic information for determining the working speed of weeder and the size when the real weeder is constructed.

  • PDF

방화문 열전달에 의한 대피공간 내부의 온도영향성 연구

  • An, Chan-Sol;Yeo, In-Hwan;An, Jae-Hong;Jo, Gyeong-Suk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.172-173
    • /
    • 2013
  • 발코니 확장에 따른 아파트의 화재안전기준 강화를 목적으로 건축법 시행령 제 46조 제 4항의 규정에 따라 현재 건축되고 아파트에는 $2m^2$이상의 대피공간을 설치해야 한다. 그리고 대피공간은 채광방향과 관계없이 거실 각 부분에서 접근이 용이한 장소에 설치해야 하며, 출입구에 설치되는 갑종방화문은 거실쪽에서만 열 수 있는 구조로 해야한다. 하지만 현재 시공되고 있는 방화문은 비차열성 방화문으로써 거실공간에서 화재가 발생하였을 경우 방화문의 열전달 현상에 의해 대피공간 내부의 온도상승이 유발되지만 현재 방화문의 차열성능에 대한 규정이 부재하기 때문에 향후 인명피해가 우려되는 상황이다. 본 연구에서는 실제 방화문의 성능시험을 통해 대피공간과 접한 방화문 면의 온도변화를 측정하였으며, 이로 인한 대피공간 내부의 온도변화를 분석하기 위해 수치해석을 수행하였다.

  • PDF

Experimental Study on Characteristics of Evaporation Heat Transfer of CO2 in a Smooth Tube (평활관에서 이산화탄소의 증발열전달 특성에 관한 실험연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.181-186
    • /
    • 2007
  • In order to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$, basic experiment on the evaporation heat transfer characteristics in a horizontal smooth tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200\;kg/m^2s$), heat fluxes ($10{\sim}80\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$). With the increase of quality, the evaporation heat transfer coefficient decreased. With the increase of heat flux, the evaporation heat transfer coefficient increased. Significantly change of the heat transfer coefficient was observed at any heat flux and mass flux. With the increase of saturation temperature, the heat transfer coefficient increased. Pressure drop increased with the increase of mass flux and the decrease of saturation temperature.

2상유동의 실험적 기법

  • 이상천
    • Journal of the KSME
    • /
    • v.30 no.4
    • /
    • pp.331-340
    • /
    • 1990
  • 본 글에서는 2상유동의 주요 인자들에 대한 측정기법을 소개하였다. 이를 위하여 가장 중요한 기본인자인 유동양식 판별법, 건도 및 질량유량 측정법, 압력강화 측정법과 기공률 측정법을 다 루었다. 이 외에도 2상유동의 실험인자는 다양하나 본 글에서는 지면관계로 열전달 계수, 계면 파구조, entrainment rate, 계면 및 벽면전단응력과 액적 및 기포의 크기 등 부차적인 유동변수 의 측정법을 다루지 못한 것을 아쉽게 생각하며 다음에 소개할 기회를 기대한다.

  • PDF

Characteristics of the Water Pressure Drop Considering Heat Transfer in the Evaporator and Condenser of a Water Chiller (냉수공장에서 열전달을 고려한 응축기와 증발기의 물 압력강하 특성)

  • Nguyen, Minh Phu;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1293-1300
    • /
    • 2011
  • The configurations of the evaporator and condenser of a water chiller can be determined from the trade-off between the heat transfer area, which is related to the capital cost and the pressure drop, which is associated with the operational cost. In this study, the design of the water chiller focused on minimizing the water pressure drop of both condenser and evaporator for given cooling capacity and requirements. Commercial enhanced tubes were employed to simulate real-life conditions. The results of the present analysis were compared with those obtained by HTRI software for verifying them. The results indicated that a reduction in the water pressure drop, which is associated with the short length of a tube, can be effected by decreasing the number of tube passes and increasing the number of tubes and the tube diameter. However, using a large number of tubes with smaller diameters can reduce the capital cost because the tubes are short. The reduction of the capital cost is due to the fact that a small-diameter tube has low internal thermal resistance and hence contributes to a decrease in the overall thermal resistance per unit length.

Study on Evaporating Heat Transfer of HCs Refrigerants by Changing of Tube Diameter (관경별 탄화수소계 냉매의 증발 열전달에 관한 특성평가)

  • Lee, Kwang-Bae;Lee, Ho-Saeng;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.41-42
    • /
    • 2005
  • The experimental apparatus has been set-up as a conventional vapor compression type heat pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70 mm, 9.52 mm, 6.35 mm with 1.78 mm,1.52 mm,1.4 mm wall thickness each is used for this investigation. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were superior to that of R-22. and the maximum increasing rate of heat transfer coefficient was found in R-1270. The average evaporating heat transfer coefficient increased with the increase of the mass velocity and it showed the higher values in hydrocarbon refrigerants than R-22. The highest evaporating heat transfer coefficient of all refrigerants was shown in a tube diameter of 6.35 mm with same mass flux.

  • PDF

Characteristics of Condensing Heat Transfer and Pressure Drop of HCs Refrigerants (탄화수소계 냉매의 응축 열전달 및 압력강하 특성)

  • Lee, Ho-Saeng;Lee, Kwang-Bae;Moon, Choon-Geun;Kim, Jae-Dol;Yoon, Jung-In
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1143-1148
    • /
    • 2005
  • Experimental results for heat transfer characteristic and pressure gradient of HCs refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness are used for this investigation. The local condensing heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average condensing heat transfer coefficient increased with the increase of the mass flux. It showed the higher values in hydrocarbon refrigerants than R-22. Hydrocarbon refrigerants have higher pressure drop than those of R-22 in 12.7 mm and 9.52 mm. This results from the investigation can be used in the design of heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.

  • PDF