• Title/Summary/Keyword: 열적 현상

Search Result 384, Processing Time 0.024 seconds

Dynamic Changes of Urban Spatial Structure in Seoul: Focusing on a Relative Office Price Gradient (오피스 가격경사계수를 이용한 서울시 도시공간구조 변화 분석)

  • Ryu, Kang Min;Song, Ki Wook
    • Land and Housing Review
    • /
    • v.12 no.3
    • /
    • pp.11-26
    • /
    • 2021
  • With the increasing demand for office space, there have been questions on how office rent distribution produces a change in the urban spatial structure in Seoul. The purpose of this paper is to investigate a relative price gradient and to present a time-series model that can quantitatively explain the dynamic changes in the urban spatial structure. The analysis was dealt with office rent above 3,306 m2 for the past 10 years from 1Q 2010 to 4Q 2019 within Seoul. A modified repeat sales model was employed. The main findings are briefly summarized as follows. First, according to the estimates of the office price gradient in the three major urban centers of Seoul, the CBD remained at a certain level with little change, while those in the GBD and the YBD continued to increase. This result reveals that the urban form of Seoul has shifted from monocentric to polycentric. This shows that the spatial distribution of companies has gradually accelerated decentralized concentration implying that the business networks have become significant. Second, contrary to small and medium-sized office buildings that have undertaken no change in the gradient, large office buildings have seen an increase in the gradient. The relative price gradients in small and medium-sized buildings were inversely proportional among the CBD, the GBD, and the YBD, implying their heterogeneous submarkets by office rent movements. Presumably, those differences in the submarkets were attributed to investment attraction, industrial competition, and the credit and preference of tenants. The findings are consistent with the hierarchical system identified in the Seoul 2030 Plan as well as the literature about Seoul's urban form. This research claims that the proposed method, based on the modified repeat sales model, is useful in understanding temporal dynamic changes. Moreover, the findings can provide implications for urban growth strategies under rapidly changing market conditions.

Analysis of Thermal Environment Characteristics by Spatial Type using UAV and ENVI-met (UAV와 ENVI-met을 활용한 공간 유형별 열환경 특성 분석)

  • KIM, Seoung-Hyeon;PARK, Kyung-Hun;LEE, Su-Ah;SONG, Bong-Geun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.1
    • /
    • pp.28-43
    • /
    • 2022
  • This study classified UAV image-based physical spatial types for parks in urban areas of Changwon City and analyzed thermal comfort characteristics according to physical spatial types by comparing them with ENVI-met thermal comfort results. Physical spatial types were classified into four types according to UAV-based NDVI and SVF characteristics. As a result of ENVI-met thermal comfort, the TMRT difference between the tree-dense area and other areas was up to 30℃ or more, and it was 19. 6℃ at 16:00, which was the largest during the afternoon. As a result of analyzing UAV-based physical spatial types and thermal comfort characteristics by time period, it was confirmed that the physical spatial types with high NDVI and high SVF showed a similar to thermal comfort change patterns by time when using UAV, and the physical spatial types with dense trees and artificial structures showed a low correlation to thermal comfort change patterns by time when using UAV. In conclusion, the possibility of identifying the distribution of thermal comfort based on UAV images was confirmed for the spatial type consisting of open and vegetation, and the area adjacent to the trees was found to be more thermally pleasant than the open area. Therefore, in the urban planning stage, it is necessary to create an open space in consideration of natural covering materials such as grass and trees, and when using artificial covering materials, it is judged that spatial planning should be done considering the proximity to trees and buildings. In the future, it is judged that it will be possible to quickly and accurately identify urban climate phenomena and establish urban planning considering thermal comfort through ground LIDAR and In-situ measurement-based UAV image correction.

Association of osteoarthritis and bone mineral density in women -The health and nutritional examination survey in Kuri- (여성의 골관절염과 골밀도간의 관련성 분석 -구리시민 건강.영양진단 조사결과를 바탕으로-)

  • Sheen, Seung-Soo;Lee, Soon-Young;Min, Byung-Hyun;Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.4 s.59
    • /
    • pp.669-685
    • /
    • 1997
  • Previous studies, reporting the inverse relationship between osteoarthritis and osteoporosis suggest the existence of possible pathophysiologic mechanisms between them. To examinine the hypothesis that 'bone mineral densities of women with osteoarthritis are significantly higher than that of women without osteoarthritis in Korea', subjects from the health and nutritional examination survey in Kuri city were sampled. Samples were selected through multi-stage sampling frame using established clusters in Kuri city. From August 18 to September 10,1997, the survey was conducted. Among the. total number of selected sample population (1,656 people), response .ate was 52.4 percent (348 men and 519 women). 420 women who took BMD measurement, radiologic exam, and anthropometric exam were selected for the analysis. The analytic results are as follows. 1. General characteristics: Mean BMD was $0.493g/cm^2$, mean age was 43.0, mean BMI was $23.9kg/m^2$. The number of women who experienced menopause was 106, hysterectomy was 19. There were 0 case of osteoarthritis of hip, 64 cases of osteoarthritis of knee, and 2 cases of osteoarthritis of hand. 2. Univariate analysis results: Mean BMD of women with the osteoarthritis of knee was significantly lower than that of women without the osteoarthritis of knee(0.4269 vs. $0.5057g/cm^2$). But, there were too few cases of osteoarthritis of hip and hand, so comparative studies of BMD in osteoarthritis of hip and hand could not be conducted. There were significant differences of BMD among pre-menopause group(0.5204), post-menopause group(0.4206), and hysterectomy group(0.4881). Additionally, there were significant differences of BMD among diabetes group(0.4297), impaired glucose tolerance group(0.4874), and normal group(0.5057). Furthermore, age, parity, BMI, bioimpedance were significantly related with BMD. 3. Multivariate analysis results: To examinine the relationship between osteoarthritis and BMD while controlling the other variables' effects which were significant in the univariate analyses, multiple linear regression analysis was done. But, it was found that osteoarthritis of knee was not a significant variable to BMD anymore. While age and menopause had significant negative relationship with BMD. Diabetes, parity, BMI, and bioimpedance did not have significant relationships with BMD. After stratification of subjects according to menopause, multiple linear regression analyses were done to each strata. Consequently, age in post-menopause group, age and osteoarthritis of knee in hysterectomy group showed significant negative relationship with BMD. The results did not support the many results of other previous studies done with white men and women. further studies of biological plausibility to Korean women are recommended. Also it is suggested that longitudinal study to verify the relationship between osteoarthritis and BMD will be valuable.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF