• Title/Summary/Keyword: 열원 모델

Search Result 89, Processing Time 0.025 seconds

A Study of the Effect of Grouting Region on the Solution of Line Source Analysis (그라우팅 영역이 선형열원 해석에 미치는 영향에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.143-150
    • /
    • 2010
  • Line source method of borehole system assumes the entire surrounding medium is uniform. However, thermal properties of grouting region are considerably different from those of surrounding soil. In this study we investigate the effect of grouting materials on the solution of line source method with the aid of numerical analysis. This numerical model generates the temperature of borehole fluid with which line source solution can be obtained. Then this solution can be compared with input condition of numerical model. The results of this comparison show that thermal conductivity and borehole thermal resistance of line source solution are approximately 86% and 91% of the input condition of numerical model. Chart method is developed in this study to find the numerical input conditions (thermal conductivity and borehole thermal resistance) from the line source solution. Thermal response test of test borehole is conducted, the results of which are approximately consistent with the Chart method. Thermal property changes of grouting materials on the line source solution are also examined.

Thermal Conductivity Estimation of Soils Using Coil Shaped Ground Heat Exchanger (코일형 지중열교환기를 이용한 지반의 열전도도 산정)

  • Yoon, Seok;Lee, Seung-Rae;Park, Hyunku;Park, Skhan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5C
    • /
    • pp.177-183
    • /
    • 2012
  • The use of energy pile foundation has been increased for economic utilization of geothermal energy. In particular, a coil-shaped ground heat exchanger (GHE) is preferred than conventional U-shaped heat exchanger to ensure better efficiency of heat exchange rate. This paper presents experimental results by changing different pitch spaces of spiral coils. Joomunjin sand was filled in a steel box of which the size was $5m{\times}1m{\times}1m$. Thermal response tests (TRTs) were conducted to measure the ground thermal conductivity with temperatures of circulating water using line source model and ring coil model. Experimental results and analytical solutions were compared to validate the applicability of these models. Ring coil model showed more accurate similar results with experimental data rather than line source model and cylindrical source model.

A Study of Determining Initial Ignoring Time of Line Source Model used in Estimating the Effective Soil Formation Thermal Conductivities (지중유효열전도율 해석에 사용되는 선형열원 모델의 초기제외시간 결정에 관한 연구)

  • Lee, Se-Kyoun;Woo, Joung-Son;Kim, Dae-Ki
    • Journal of Energy Engineering
    • /
    • v.17 no.3
    • /
    • pp.167-174
    • /
    • 2008
  • Line source model is commonly used in analyzing the data obtained from thermal response test to estimate the effective soil formation thermal conductivity. In the application of line source model some part of initial data must be ignored in order to achieve more accurate result. The period of time for this initial data is called initial ignoring time(IIT) in this paper. However there has been no definite rule in determining this initial ignoring time. Therefore line source model requires experienced analyzer to select the useful data, which is somewhat subjective. One method often suggested is the calculation of IIT with non dimensional time $\tau=5$. However, this is a very theoretical result derived from a system of perfect line source model, which is somewhat different from the real system. A new method to determine IIT is presented in this study. This method requires error estimation first and IIT can be decided from the results of error estimation. This method is applied in the analysis of field test data and shows better result than the one obtained from the method using non dimensional time mentioned above as shown in Table 2.

생활폐열회수를 위한 열교환기 개발 중심 폐열회수 고효율 난방 시스템

  • 신현준;이태원
    • 월간 기계설비
    • /
    • s.46
    • /
    • pp.65-73
    • /
    • 1994
  • 도시생활폐수에 포함되어 배출되는 폐열을 열펌프의 열원으로 하는 폐수열원 열펌프 시스템에 대한 관심이 오래전부터 집중되어 있었지만 폐수 열교환기 전열면의 오염문제 때문에 실용화에 커다란 진전을 보지 못하고 있다. 한편, 생활페수는 비교적 저온이기 때문에 열펌프시스템의 설계에 특별한 주의를 기울여야 한다. 즉, 이러한 폐열을 회수하여 유효에너지 자원화 하기 위한 신기술이 이루어 져야한다. 본 연구에서는 이러한 점을 감안하여 도시생활 폐수열의 이용가능성을 검토하고 이를 열원으로 하는 열펌프의 개발을 위한 폐수 열교환기의 모델을 개발하였다.

  • PDF

Non-Fourier 열전달에 대한 소고

  • 김우승
    • Journal of the KSME
    • /
    • v.31 no.8
    • /
    • pp.735-744
    • /
    • 1991
  • 확산모델과 파모델의 결과에 있어 큰 차이가 일어나는 경우를 요약하면 다음과 같다. 1) 과도기 간이 짧다. 2) 작동온도가 아주 낮다. 3) 온도구배가 상당히 크다. 이때3)의 경우는 서로 다른 물질들이 접촉된 경우 또는 높은 열유속이 있는 경우 또는 얇은 표면층 등을 갖는 문제들의 공 통적인 특징이다. Non-Fourier 열전도 문제를 이용해 온도 분포를 예측해야 하는 실제적인 몇 가지 예를 살펴 보면 레이저 기술 또는 절대온도 영(zero)에 접근하는 온도에서의 액체 헬륨을 다루는 저온공학연구 또는 1/$10^{6}$Inch 정도의 표면조도가 관심사인 정밀공학 등을 들 수 있다. 또한 상당히 높은 강도의 열원이 작용될 때 고체에서의 크랙이나 보이드(void) 같은 국소 결함은 확산거동이 나타나기에 요구되는 시간보다 짧은 시간 구간에서 발생되어질 수 있으며, 크랙발생의 방향과 같은 것들은 hyperbolic 모델에의해 예측되어져야만 한다. 특히 움직이는 열원 또는 propagating crack tip을 갖는 경우에 그들 주위에서의 온도장을 규정짓는 가장 중요한 변 수는 열마하수 M이며, 아음속에서 초음속 영역으로 천이될 때 물리적 양들의 변화에 있어서 일어나는 현상들은 열충격의 형성에 기인하는데 이러한 현상들은 확산 모델로서는 예측될 수 없는 특징들이다. 이상에서 살펴볼 때 non-Fourier 모델에 대해 관심을 기울일 필요가 있다고 사료된다.

  • PDF

An Estimation of Equivalent Heat Source for Thermal Analysis of Steel Deck Bridge under Pavement Procedure (강바닥판 교량의 포장시 열영향 해석을 위한 등가열원 산정기법)

  • Chung, Heung-Jin;Yoo, Byoung-Chan;Lee, Wan-Hoon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.653-660
    • /
    • 2007
  • Since the temperature of asphalt for deck plate of steel bridge during paying procedure is relatively high as $240^{\circ}C\;to\;260^{\circ}C$, the temperature of deck plate of bridge rises mere than $100^{\circ}C$ and excessive displacement and stress could occur. In order to avoid undesirable failure of base plate and determine the optimal pavement pattern, a thorough thermal analysis is needed. General structural model which is made of beam and plate element should be modified for transient heat transfer analysis; asphalt pavement material and convection effect on surface of structure need to be added. A new technique with the Equivalent Heat Source (EHS) for numerical thermal analysis for steel bridge under thermal load of Guss asphalt pavement is proposed. Since plate/beam elements which were generally used for structural analysis for bridge cannot explain convection effect easily on plate/beam surface, EHS which is determined based on calculated temperature with convection effect is used. To verify the EHS proposed in this study, numerical analyses with plate elements are performed and the results are compared with estimated temperatures. EHS might be used for other thermal analyses of steel bridge such as welding residual stress analysis and bridge fire analysis.

집단에너지사업 수도권 네트워크 경제성 분석

  • 박용순;송은영
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.29 no.1
    • /
    • pp.48-56
    • /
    • 2000
  • 한국지역난방공사는 '87년 여의도에 최초 연공급을 시작한 이래 수도권 신도시 및 서울 강남 지역을 중심으로 지역난방 열공급을 지속적으로 확대하여 왔다. 안정적이고 경제적인 역공급을 위하여 분당, 고양 및 중앙의 CHP를 중심으로 연계배관망을 구성하였으며 '98년 기준 수도권 연계 공급량이 총 공급량의 61%를 차지하게 되었다. 또한 장기적으로 본 공사는 열공급의 신뢰성 및 경제성 향상을 위하여 급열센타 설치를 비롯하여 종합적인 네트워크를 구성하여 운영할 계획이며 분당과 고양의 CHP를 기저부하로 삼아 피크수요를 감당할 소규모 분산형 열원을 설치하여 수도권 열공급을 확대하여 전 수도권을 지역난방 배관으로 네트워크화할 계획을 가지고 있다. 따라서, 구체적인 세부계획을 수립하기 위하여는 수도권 네트워크 사업의 장기적인 경제성 분석이 필수적이며 이러한 분석은 기존의 열원 및 열배관시설은 물론 향후 건설될 열원 및 배관, 수요개발전망 등 제반요소를 고려하여 종합적으로 이루어져야 하다. 본 연구는 이에 앞서 분당과 일산CHP를 독립된 수용범위를 갖는 열원으로 간주하여 각각의 CHP를 중심으로 열공급량의 증가에 따라 피크용 열원인 HOB 건설을 증가시킬때의 경제성을 그 대상으로 하여 기본적인 모델을 제시하고 대략적인 추세를 파악하고자 하였다. 데이터는 본 공사 고양지사와 분당지사의 '98 운영실적으로 기준으로 하였으며, 수도권 전체 네트워크를 대상으로 하는 실제 경제성 분석은 다음 과제로 계속 추진될 것이다.

  • PDF

The Optimal Operation Pattern and Heat Pricing Scheme for District Heating CHP System (지역난방용 열병합발전시스템의 최적운전패턴과 적정 열요금구조)

  • 권영한;김창수;진병문;김진오
    • Journal of Energy Engineering
    • /
    • v.5 no.2
    • /
    • pp.183-192
    • /
    • 1996
  • This paper presents a numerical model of the optimal operation pattern of the CHP system built for duel-purpose of power generation and district heat production. The model can be differently formulated in accordance with the view of planner: society, electric utility or district-heating company. Here, the operation pattern of the system components and the effect of heat price are of major interest in the study. From the case study, it was found that the optimal use of auxiliary heating equipment is very important to achieve the minimum societal cost. And, the multi-step heat pricing scheme is desirable to induce the voluntary behavior of both companies towards the societal optimal pattern.

  • PDF

A Study on Heat Source Model to Creep Feed Grinding (크?피드 연삭에서 열원 모델에 관한 연구)

  • Jeong, Jong-Dal;Jeong, Hae-Do;Choe, Heon-Jong;Kim, Nam-Gyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.171-176
    • /
    • 2001
  • This study focuses on the energy partition and heat flux distribution in creep-feed grinding. From the measurements of transient grinding temperature in the workpiece which the thermocouple was embedded, the overall energy partition to the workpiece was estimated with moving heat source theory using the developed scalene triangle heat model. The energy partition was calculated as 3.75% in down grinding smaller than 5.3% in up grinding. Also, the scalene triangle heat model was confirmed as the most optional heat model in correspond to the experimental data. Then, the heat flux distribution was calculated from temperature responses. The heat flux is negative behind the grinding zone where fluid was applied. In this experimental result, the total heat flow to the workpiece per unit width obtained by integrating the positive heat flux was 0,7W/mm for down grinding.

  • PDF

Numerical Prediction of Smoke Concentration in a Compartment Fire by Using the Modified Volumetric Heat Source Model (수정된 체적열원모델을 이용한 실내 화재의 연기농도 예측)

  • Kim Sung-Chan;Lee Seong-Hyuk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.4
    • /
    • pp.344-350
    • /
    • 2006
  • The present study investigates the characteristics of fire-driven heat flows and gas concentration in a compartment fire by using the modified VHS model (MVHS). The main idea of this model is to add some source terms for combustion products and oxygen consumption to the original VHS model for providing more accurate and useful information on gas concentration distributions as well as thermal fields. It is found that the present MVHS model shows fairly good agreement with the experimental data and the eddy breakup combustion model. The tilting angle of fire plume calculated by MVHS is larger than that of EBU model because the fire source of VHS is affected by ventilating flow less than EBU. However, this discrepancy is apparently reduced in the downstream region of fire source.