• 제목/요약/키워드: 열별

검색결과 6건 처리시간 0.03초

휜-관 열교환기의 열별 열전달 계수 측정 (Heat Transfer Coefficients of Individual Rows for Fin-and-Tube Heat Exchangers)

  • 신태룡;이응렬;김내현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1034-1039
    • /
    • 2004
  • The row-by-row heat transfer characteristics of fin-and-tube heat exchangers having wavy fins were experimentally investigated. Three samples having different rows (one, two and three) were tested. Results show that the heat transfer coefficient is strongly dependent on the tube row. The heat transfer coefficient of the first row is larger than those of second or third rows. However, the difference decreases as the Reynolds number increases. The heat transfer coefficients of the second and the third row are approximately the same, probably due to increased mixing of bulk flow by wavy channels. Although samples have different tube row, the heat transfer coefficients of same row are approximately the same.

  • PDF

핀-관 열교환기의 열별 열전달 특성 (Heat Transfer Characteristics of Individual Rows for Fin-and-Tube Heat Exchangers)

  • 김내현;신태룡;한성필
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.149-155
    • /
    • 2007
  • The row-by-row heat transfer characteristics of fin-and-tube heat exchangers were experimentally investigated. Three wavy fin samples having different rows (one, two and three) and one plain fin sample (three row) were tested for $600{\leq}Re_{D}{\leq}4,000$. The heat transfer data were obtained for individual rows, and the corresponding heat transfer coefficients were reduced from the data. Results showed that the heat transfer coefficients were strongly dependent on the tube row. The heat transfer coefficient decreased as the tube row increased. However, the row effect was different depending on the fin shape. For the wavy fin, the row effect significantly decreased as the Reynolds number increased, yielding approximately the same heat transfer coefficients at $Re_{D}{\approx}2,500$. For the plain fin, however, the row effect lasted for the whole Reynolds number range. The increased mixing of bulk flow by wavy channels appears to induce high heat transfer coefficient (accordingly diminishing row effect) at downstream rows. The heat transfer coefficients of individual rows were higher for heat exchangers having larger tube rows.

단체법에서 기저역행렬과 입력자료의 보관방법과 자료구조

  • 김우제;안재근;성명기;박순달
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 1995년도 춘계공동학술대회논문집; 전남대학교; 28-29 Apr. 1995
    • /
    • pp.646-655
    • /
    • 1995
  • 본 연구에서는 기저역행렬의 계산방법에 따른 효율적인 자료구조를 실험적으로 검토하고, 입력자료방식과 효율화 방법을 제안하여 구현하였다. 기저역행렬의 계산방법에 따른 효율적인 자료구조는 명시형에서는 연결리스트 방식이 유리하였으며, 상하분해형에서는 연결 리스트 방법과 Gustavson 방법이 비슷한 효율을 보였다. 새로운 비영요소의 도입이 많은 경우일수록 연결 리스트가 효율적인 자료구조인 것으로 분석된다. 그리고 MPS자료의 입력방식과 효율화 방안에서는 각 열별로 행 정렬을 실시하고 해싱(hashing)함수를 도입하여 효율화를 기하였다.

  • PDF

2열 핀-관 열 교환기의 열별 전열성능 측정 (Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers)

  • 권영철;정지환;장근선;홍기수;진심원
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

중국(中國) 닝샤회족(寧夏回族)자치구 옌츠현(池縣)의 인공 닝티아오 수림대의 방풍(防風) 및 방사효과(防砂效果) (Windbreak Effect on Wind Speed Reduction and Sandbreak of Artificial Forest Belt of Caragana Korshinskili Kom in Yanchi county, Ningxia Province, China)

  • 박기형;정국동;왕휘휘;왕상우;전근우
    • 한국산림과학회지
    • /
    • 제97권1호
    • /
    • pp.95-101
    • /
    • 2008
  • 중국 닝샤(寧夏)회족(回族)자치구 옌츠현(池縣) 샤췐완(沙泉灣)의 북경임업대학 사막화 방지연구기지 닝티아오 수림대(樹林帶)에서 실시한 방풍실험 결과는 다음과 같다. 1. 0.5m 높이의 각 열별(列別) 방풍효과(防風效果)를 분석한 결과, 1H(H = Tree Height) ~ 5H 까지의 방풍효과는 3열(30.22%) > 2열(26.53%) > 1열(16.28%)의 순으로, 7H 이후의 방풍효과는 2열(16.11%) > 3열(12.79%) > 1열(9.82%)의 순으로 나타났다. 2열과 3열의 회귀분석 결과, 2열 수림대의 방풍효과는 44H에 이르렀으며, 3열 수림대의 방풍효과는 27H에 이르렀다. 이 결과를 통해 단거리에는 3열 수림대의 방풍효과가 높고, 장거리는 2열 수림대의 방풍효과가 높다는 것을 알 수 있었다. 2. 1.0m 높이의 각 열별 방풍효과를 분석한 결과, 평균 방풍효과는 1열 8.04%, 2열 8.23%, 3열 7.43%로 큰 변화 없이 비교적 안정적인 풍속을 나타냈다. 3. 평균 방사효과(防砂效果)는 2열(55.28%) > 3열(37.13%) > 1열(20.87%)의 순으로 나타났으며, 특히 2열 수림대의 경우, 1H 지점에서 방사율이 86.06%로 가장 높은 방사효과를 나타냈다.

광절열두조충감염 5예 (Five Cases of Diphyllobothrium latum Infection)

  • 이순형;서병양
    • Parasites, Hosts and Diseases
    • /
    • 제21권2호
    • /
    • pp.150-156
    • /
    • 1983
  • 1975년부터 1983년까지 치료를 위해 서울의대 기생충학교실로 의뢰된 광절열두조충 충란양성자 5명에 대하여 bithionol, niclosamide 또는 praziquantel을 투여 하고 하제를 사용하여 충체를 얻은바 Diphyllobothrium latum으로 동정되었다. 충자는 서울 및 전남 완도군에 거주하고 있는 10~64세 남(4명) 여(1명)로 그중 2례는 농어를 생식한 경험이 있으며 나머지 3례는 바다생선회를 생식하였으나 그 종류를 기억할 수 없다고 한다. 또 그중 3례는 심한 복통과 소화기증상을 경험하였고, 2례는 편절이 자연배출된 일이 있다고 하나 빈혈소견은 전례에서 관찰되지 않았다. 대편검사에서 발견된 충란은 명 열별로 크기 평균 $59~67{\times} 41~48{\mu}m$이고 황갈색 유란원형 또는 타원형이 있으며 operculum과 abopercular protuberance가 뚜렷하였다. 충체는 4례에서 두절을 포함한 걸이 320~680cm의 완전한 것이 배출되었고 l례에서는 투약후 충체 배출여부를 확인하지 못하고 자연배출된 길이 30cm정도의 체절을 동정에 이용하였다. 특징적인 편절의 형태인 rosette형 자궁, vaginal pore가 cirrus sac에 포함되어 개구된 점, 재정과 cirrus sac의 분리 등으로 보아 Diphyllobothrium latum으로 동정되었다. 본 5례는 우리나라에서 1971년 이후 충체가 확인된 6례에 이어 제 7례-제11례의 인체기생례가 된다.