• Title/Summary/Keyword: 열미로

Search Result 5, Processing Time 0.02 seconds

Case Study on Application of Ground Heat Source in Thermal Labyrinth by CFD Model (CFD 모델을 이용한 열미로의 지중열원 활용에 관한 사례 연구)

  • Min, Joon-Ki;Nam, Sun-Young
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • In order to evaluate the performance of ground heat source in thermal labyrinth on pre-heating in winter season and pre-cooling in summer season, the followings are made as a conclusion through case study of H project by using the weather data from Korea meteorological administration and CFD model. By making outdoor air inlet via ground heat source in thermal labyrinth for conduction, convection and etc., the temperature rise is $13.4^{\circ}C$as the effect of pre-heating in winter season. On the other hand, as the effect of pre-cooling in summer season, the temperature decrease is $7.2^{\circ}C$. The energy saving rate by the application of ground heat source in thermal labyrinth is 9.1%.

Adaptive Intrusion Detection Algorithm based on Aritificial Immune System (인공 면역계를 기반으로 하는 적응형 침입탐지 알고리즘)

  • 양재원;이동욱;심재윤;심귀보;이세열;김용수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.254-257
    • /
    • 2002
  • 인터넷 보급의 확산과 전자상거래의 활성화와 유.무선 인터넷의 보급에 따른 악의적인 사이버 공격의 시도의 성공사례가 증가하고 있다. 미로 인해 점차 더 많은 문제가 야기될 것으로 예상된다. 현재 일반적인 인터넷상의 시스템은 악의적인 공격에 적절하게 대응해오지 못하고 있으며, 다른 범용의 시스템들도 기존의 백신 프로그램에 의존하며 그 공격에 대응해오고 있다. 따라서 새로운 침입에 대하여는 대처하기 힘든 단점을 가지고 있다. 본 논문에서는 생체 자율분산시스템의 일부분인 T세포의 positive selection과 negative selection을 이용한 자기/비자기 인식 알고리즘을 제안한다. 제안한 알고리즘은 네트워크 환경에서 침입탐지 시스템에 적용하여 기존에 알려진 침입뿐만 아니라 새로운 침입에 대해서도 대처할 수 있다

Development of New Device to Improve Sucess Rate of Maze Procedure with Radiofrequency Energy (고주파에너지를 이용한 미로술식의 성적향상을 위한 새로운 기구의 개발)

  • 박남희;유양기;이재원
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.467-473
    • /
    • 2004
  • Background: The sinus conversion rate after the maze procedure in chronic atrial fibrillation using radiofrequency energy is lower than with either conventional 'cut and saw' technique or cryothermia. The creation of incomplete transmural lesions due to poor tissue-catheter contact is thought to be the main cause. To address this problem, the current study was aimed to evaluate the effectiveness of a specially constructed compression device designed to enhance tissue catheter contact during unipolar radiofrequency catheter ablation. Material and Method: Circum-ferential right auricular epicardial lesions were created with a linear radiofrequency catheter in 10 anesthetized pigs. A device specially designed to increase contact by compression of the catheter to the atrial wall was used in 5 pigs (study group). This device was not used in the control group (5 pigs). Conduction block across the right auricular lesion was assessed by pacing, and the transmurality of the lesions were confirmed by microscopic examination. Result: Conduction block was observed in a total of 8 pigs; 5 in study group and 3 in control group. Transmural injury was confirmed microscopically by the accumulation of acute inflammatory cells and loss of elastic fibers in the endocardium. In two pigs with failed conduction block, microscopic examination of the endocardium appeared normal. Conclusion: Failed radiofrequency ablation is strongly related to non-transmural energy delivery. The specially constructed compression device in the current study was successful in creating firm tissue-catheter contact and thereby generating transmural lesions during unipolar radiofrequency ablation.

Biocompatibility and Histopathologic Change of the Acellular Xenogenic Pulmonary Valved Conduit Grafted in the Right Ventricular Outflow Tract (우심실 유출로에 이식한 무세포화 이종 폐동맥 판막도관의 생체 적합성 및 조직병리학적 변화양상에 대한 연구)

  • 허재학;김용진;박현정;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.482-491
    • /
    • 2004
  • Background: The xenogenic or allogenic valves after in Vitro repopulation with autologous cells or in vivo repo-pulation after acellularization treatment to remove the antigenicity could used as an alternative to synthetic polymer scaffold. In the present study, we evaluated the process of repopulation by recipient cell to the acellu-larized xenograft treated with NaCl-SDS solution and grafted in the right ventricular outflow tract. Material and Method: Porcine pulmonary valved conduit were treated with. NaCl-SDS solution to make the grafts acellularized and implanted in the right ventricular outflow tract of the goats under cardiopulmonary bypass. After evaluating the functions of pulmonary valves by echocardiography, goats were sacrificed at 1 week, 1 month, 3 months, 6 months, and 12 months after implantation, respectively. After retrieving the implanted valved conduits, histopathologic examination with Hematoxylin-Eosin, Masson' trichrome staining and immunohistochemical staining was performed. Result: Among the six goats, which had been implanted with acellularized pulmonary valved conduits, five survived the expected time period. Echocardiographic examinations for pulmonary valves revealed good function except mild regurgitation and stenosis. Microscopic analysis of the leaflets showed progressive cellular in-growth, composed of fibroblasts, myofibroblasts, and endothelial cells, into the acellularized leaflets over time. Severe inflammatory respon-se was detected in early phase, though it gradually decreased afterwards. The extracellular matrices were regenerated by repopulated cells on the recellularized portion of the acellularized leaflet. Conclusion: The acellularized xenogenic pulmonary valved conuits were repopulated with fibroblasts, myofibroblasts, and endothelial cells of the recipient and extracellullar matrices were regenerated by repopulted cells 12 months after the implantation. The functional integrity of pulmonary valves was well preserved. This study showed that the acellularized porcine xenogenic valved conduits could be used as an ideal valve prosthesis with long term durability.

An Anatomical Study of the Posterior Tympanum (한국인 중이강후벽에 관한 형태해부학적 고찰)

  • 양오규;윤강묵;심상열;김영명
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.2-19
    • /
    • 1982
  • The sinus tympani is subject to great variability in the size, shape and posterior extent. A heavy compact bony zone, especially in the posterior portion and the narrow space between the facial nerve and posterior semicircular canal are the limitation of surgical approach. The facial recess should be opened, creating a wide connection between the mesotympanum and mastoid in the Intact canal wall tympanoplasty with mastoidectomy. The surgically created limits of the facial recess are the facial nerve medially, the chorda tympani laterally and the bone adjacent to the incus superiorly. Using adult Korean's thirty-five temporal bones, the authors measured the osteologic reslationship in the posterior tympanum, especially sinus tympani and facial recess. The result was as followed. 1. The average distance from the anterior end of the pyramidal eminence. 1) to the edge of the sinus tympani directly posterior was 2.54(1.05-5.40)mm. 2) to the maximum posterior extent was 3.22(1.25-7.45)mm. 3) to the maximum cephaled extent was 0.67 (0.40-1.75)mm. 2. The boundary of the sinus tympani was 82.9% from the lower margin oval window to the upper margin round window niche. 3. The deepest part of the sinus tympani was 62.9% in the mid portion, between the ponticulus and subiculum. 4. The oblique dimension from the fossa incudis above to the hypotympanum below was 8.13(7.90-9.55)mm. 5. The transverse dimensions midway between the oval window above and round window below was 3.00(2.85-3.45)mm. 6. The transverse dimension at the level of the fossa incudis was 1.81(1.40-2.15)mm. 7. The facial nerve dehiscence was 14.3%. 8. Anterior-posterior diameter of the footplate was 2.98(2.85-3.05) mm. 9. The average distance from the footplate. 1) to the cochleariform process was 1.42(1.35-1.55) mm. 2) to the round window niche was 1.85(1.45-2.10) mm.

  • PDF