• 제목/요약/키워드: 열등가회로

검색결과 5건 처리시간 0.011초

간접냉각이 이용된 지중송전케이블의 적정냉각조건에 관한 연구 (A Study on the Optimum Cooling Condition of the Underground Power Transmission Cable Equipped with a Separate Pipe Cooling System)

  • 박만흥;최규식;서정윤;김재근;이재헌
    • 설비공학논문집
    • /
    • 제4권4호
    • /
    • pp.263-276
    • /
    • 1992
  • The transmission current in a power cable is determined under the condition of separate pipe cooling. To this end, the thermal analysis is conducted with the standard condition of separate pipe cooling system, which constitutes one of the underground power transmission system. The changes of transmission current in a power cable with respect to the variation of temperatures and flow rates of inlet cooling water as well as the cooling spans are also determined. As a consequnce, the corresponding transmission current is shown to vary within allowable limit, resulting in the linear variation of the current for most of the cable routes. The abrupt changes of current, however, for the given flow rate of inlet cooling water in some cooling span lead to the adverse effects on the smooth current transmission within the underground power transmission system. In practice, it is expected that the desinging of the separate pipe cooling system in conjunction with the evaluation of system capacity should take into account the effects of design condition on the inlet cooling flow rate.

  • PDF

열등가회로를 이용한 5 kW 급 영구자석 동기전동기의 정상상태 열 특성 해석 (Steady-state Thermal Analysis of 5 kW IPMSM Using Thermal Equivalent Circuit)

  • 김태현;유영범;나종승;유경태;문윤재;이재헌;이주;박찬배;문승재
    • 대한기계학회논문집B
    • /
    • 제38권11호
    • /
    • pp.951-956
    • /
    • 2014
  • 본 논문에서는 영구자석 동기전동기의 특정 운행조건 중 발생하는 열 발생량에 대해, 열등가회로를 이용하여 정상상태 열 해석을 수행하였다. 최근 전동기는 소형, 경량화되며 극한 운행조건에서도 고출력 밀도를 견뎌야 한다. 특히, IPMSM 의 코일과 영구자석에서 발생하는 과도한 열은 전동기의 출력을 감소시키고, 전동기의 수명에 악영향을 끼치기 때문에 설계단계에서 IPMSM 의 열 해석이 중요하다. 그러므로, 본 연구에서는 열등가회로를 이용하여 IPMSM 의 설계변수 변화에 따라 정상상태 열 해석을 진행하였다. 변화된 설계변수는 하우징의 축방향 길이 그리고 하우징 두께이다. 마지막으로 열등가회로를 이용한 열 해석 결과와 유한요소법을 이용한 열 해석 결과를 비교하고, 열 해석 결과에 정확성과 신뢰성을 확인하고자 한다.

철도차량용 영구자석 동기전동기의 열해석 기법 연구 (Investigation of a Thermal Analysis Method for IPMSM in Railway Vehicles)

  • 박찬배;이형우;이병송
    • 한국철도학회논문집
    • /
    • 제16권2호
    • /
    • pp.99-103
    • /
    • 2013
  • 본 논문에서는 철도차량 추진용 매입형 영구자석 동기전동기(Interior Permanent Magnet Synchronous Motor, IPMSM)의 운전 중 열 발생 특성 분석을 위한 열해석 기법 연구를 수행하였다. IPMSM의 구동 중에 권선, 코어, 영구자석에서 발생되는 과도한 열은 IPMSM의 장시간 연속운전을 어렵게 만들기 때문에, IPMSM에서 발생된 열의 효율적인 냉각이 중요하다. 따라서 본 연구에서는 IPMSM의 냉각장치 적용을 위한 선행 연구로써 IPMSM 의 열 발생 특성 분석을 위하여 IPMSM의 각 구성품에 대한 열전달 계수를 도출하고, 열 등가회로를 구성하여 열해석을 수행하는 열해석 기법 연구를 수행하였다. 또한 IPMSM 실 모델의 열 실험 데이터와의 비교를 통한 열해석 기법의 유효성 검증을 수행하였다.

철손밀도 분포에 의한 열원이 고려된 3차원 열등가회로망을 이용한 경량전철 구동용 110kW급 IPMSM의 열 특성 연구 (A Study on the Thermal Characteristics of 110kW-class IPMSM for Light Railway Transit using the 3-Dimensional Thermal Equivalent Network considering Heat Source by Iron Loss Density Distributions)

  • 박찬배
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1038-1044
    • /
    • 2013
  • A research on thermal analysis method is conducted for the characterization of heat generation during operation of Interior Permanent Magnet Synchronous Motor(IPMSM) for Light Railway Transits(LRT) in this paper. Efficient cooling of the heat generated in the IPMSM is important because the excessive heat generated from the winding, core and permanent magnet makes it harder for a long time continuous operation of IPMSM. Therefore, in order to analyze the heat generation characteristics of the 110kW-class IPMSM as advanced research for application the IPMSM to the cooling device, the heat transfer coefficients for each component of the 110 kW-class IPMSM were derived and the thermal equivalent network was configured to perform the thermal analysis in this study. Finally, the 110kW-class IPMSM prototype is made and a comparative verification between the test data and the thermal analysis results through its various performance tests are carried out.

여러가지 열적 변수가 전폐형 유도전동기의 코일온도상승에 미치는 영향에 관한 연구 (The effects of various thermal parameters on coil temperature rise in TEFC induction motor)

  • 윤명근;하경표;이양수;고상근;한송엽
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.570-578
    • /
    • 1997
  • At design stage of new motor or when taking remedial action of old motor, a lot of information can be obtained from thermal parameters analysis. This study focused on the temperature rise of TEFC induction motor with respect to various thermal parameters. Frame heat transfer had the most important effect on coil temperature rise. But those of air gap and rotor fan had no effect. This fact shows fan action is more important than fin action in the case of rotor fan. Coil temperature can be more decreased by cooling near the heat sources than any other parts from the results of thermal conductivity and loss tests. Variation of cooling air flow rate and motor volume effects on coil temperature were also tested. These tests suggest that improvement of cooling fan performance is important in reducing the coil temperature rise. Thermal equivalent program was verified by comparison of some experimental results.