자동차 공조용 핀형 열교환기의 성능특성에 관한 연구 (A Study on the Performance Characteristics of Fin-type Heat Exchanger for the Automobile Air-Conditioners)

  • 홍경한;전상신;이승재;박찬수;권일욱;김재열;김병철;하옥남
    • 한국공작기계학회논문집
    • /
    • 제13권4호
    • /
    • pp.100-105
    • /
    • 2004
  • Fin-tube type(Fin-type) heat exchanger has been tested in order to replace the heat exchanger of parallel flow type(P.F -type) which is now widly used in automobile air conditioning system The following conclusions are drawn by the comparison of the characteristics of the heat exchangers. Evaporator and condenser capacities and COP(Coefficience of performance) were varied as with the compressor speed, outdoor air temperature and air flow rate changed, which much influenced on the characteristics of the air conditioning system Evaporator and condenser capacities were increased with increasing compressor speed and outdoor air temperature. Evaporator and condenser pressures of Fin-type were decreased by 7% and 5% respectively compared with those of P.F-type. The COP of Fin-type was decreased with increasing outdoor air temperature and compressor speed. The COP of P.F-type was decreased by 14% compared with that of Fin-type.

건조기용 타원관 대구경 핀-관 열교환기의 성능특성 (Performance Characteristic of Large Diameter Oval Finned-Tube Heat Exchanger for Dryer)

  • 배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.22-27
    • /
    • 2014
  • The objectives of this paper are to obtain an empirical equations regarding the correlations between heat transfer and pressure drop of oval fin-tube heat exchanger having large diameter using wilson plot method. It was difficult to find any recommendable heat transfer and friction factor correlation available for our large diameter experimental cases. Overall heat transfer coefficients are composed of the heat transfer coefficients both inside and outside tubes. The resulting empirical correlations for the Nui and f-factor are given as $Nu_i=0.0146Re^{0.809}Pr^{0.3}$ and $f=4.366Re^{-0.64}$, respectively. The empirical correlations of the Nui and f-factors were developed for the large diameter oval finned-tube heat exchanger as a function of the Reynolds number. As the EG(Ethylene glycol) and air flow rate increases, the heat transfer rate and pressure drop is increased largely.

다양한 형태의 단속표면을 갖는 공조기용 핀-관 열교환기의 열전달 특성 (Heat transfer characteristics of fin and tube heat exchangers with various interrupted surface for air conditioning application)

  • 윤점열;이관수
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.3938-3948
    • /
    • 1996
  • This study is related with the experimental investigation on the heat transfer and pressure drop characteristics of the fin-and-tube heat exchangers with three different interrupted fins and a plane fin for air-conditioning application. Experiments were conducted accordingly following the appropriate development process. Geometry similitude experiment was introduced to predict the performance of fins, and prototype experiment was also performed to confirm the validity of geometry similitude experimental results. However, these experimental results were limited to the sensible heat transfer characteristics of the heat exchangers. Hence, additional experiment was performed using refrigerant to investigate the latent heat transfer characteristics. This paper presents an appropriate process for the development of a new type heat exchanger. Sensible and latent heat transfer characteristics for each fin configuration is also provided along with the optimal fin configuration.

수직 평행평판에서의 혼합대류 열전달 (Combined Convective Heat Transfer from Vertical Parallel Plates)

  • 양성환;권순석
    • 대한기계학회논문집
    • /
    • 제13권2호
    • /
    • pp.299-306
    • /
    • 1989
  • 본 연구에서는 밀집형 열교환기에 사용되고 있는 루우버 핀에 해당되는 간단한 형상인 등온, 수직, 평행평판에서의 혼합대류 열전달에 관하여 Pr=0.7, Gr=$10^{4}$ 및 50<Re$_{L}$<500인 경유 평판간격과 평판길이를 변수로 하여 유한차분법으로 수치해석하였다. 속도분포, 온도분포 및 Nusselt수를 구하여 평판의 간격과 길이가 열전달에 미치는 영향에 관하여 연구하였다.

PTC 전열시트를 사용한 핀-관 열교환기의 제상 특성에 관한 실험적 연구 (An experimental study of defrosting behaviors on the fin-tube heat exchanger with PTC heating sheet)

  • 지성;이관수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.147-155
    • /
    • 1999
  • In this work, the defrosting characteristics of PTC heating sheet used as a defrosting heat source of fin-tube heat exchanger in a refrigerator have been experimentally compared with those of conventional electric heater. It is found that the characteristics of water draining rate with defrosting time show smoothly oscillating pattern when PTC heating sheet is used, and the drained water is completely melted. The defrosting efficiency of the PTC heating sheet is about 75%, which represents about 25% higher than that of the electric heater. A reduction of defrosting time and an increase of defrosting efficiency may be obtained by improving the arrangement of heating elements of the heating sheet. It is shown that the defrosting time of PTC heating sheet increases linearly with the amount of frost, however the defrosting efficiency is nearly constant. In the application to the refrigerating system, one should notice the fact that the defrosting performance of PTC heating sheet may be defraded due to the repeated operations.

  • PDF

루우버핀 열교환기의 핀피치가 공기측 열전달에 미치는 영향 (Effect of Fin Pitch on Air Side Heat Transfer in Louvered-Fin Heat Exchanger)

  • 장봉주;김선정
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.31-38
    • /
    • 2000
  • In order to study on influence of fin pitch and shape of heat exchanger on the elevation of heat transfer efficiency, we make models of louvered fin type heat exchanger which was given a transformation of fin pitch in louvered fin type heat exchanger which are of en used now. And the influence of fin pitch on pressure drop and characteristics of heat transfer was experimented and analysed when air velocity and fin pitch was a variable. The results of experiment shows below. Pressure drop shows larger in louvered fin type heat exchanger than in plate fin type heat exchanger, size of pressure drop shows like this order that fin space is 4mm, 5mm, 6mm. Mean heat transfer coefficient shows higher in louvered fin type heat exchanger than in plate fin type heat exchanger, size of mean heat transfer coefficient by fin space shows same in both case in louvered fin type heat exchanger and plate fin type like this order that fin space is 4mm, 5mm, 6mm.

  • PDF

원자력발전소 습분분리재열기 튜브 원격장검사 기술 개발 (Development of Remote Reld Testing Technique for Moisture Separator & Reheater Tubes in Nuclear Power Plants)

  • 남민우;이희종;김철기
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.339-345
    • /
    • 2008
  • 원자력발전소 열교환기 튜브의 대부분은 구리, 티타늄, 인코넬합금 등의 비자성체로 제작되어 있으나 2차 터빈계통의 습분분리재열기(moisture separator & reheater), 급수가열기 등의 튜브는 고압, 고온 등의 열악한 운전조건에서 상대적으로 고온 강도가 우수한 탄소강 또는 페라이트계열 스테인레스강 등의 자성체로 제작되어 있다. 특히 습분분리재열기 튜브와 같은 열교환 매체가 증기인 경우 열전달 능력을 증가시키기 위해서 핀 튜브를 사용한다. 탄소강 또는 페라이트계열 스테인레스강 등의 자성체 튜브는 고온, 고압에서 강도가 우수하지만 운전 중에 증기 커팅, 침식, 기계적 진동 마모, 응력부식균열 등의 사용 중 결함이 발생하여 발전소 정상운전에 지장을 초래할 수 있기 때문에 전열관의 건전성 평가를 위한 주기적인 비파괴검사의 수행이 필요하다. 하지만 자성체 열교환기 튜브는 투자율이 높은 전기적 특성으로 인하여 기존의 와전류검사기술로는 비파괴검사가 어렵기 때문에 원격장검사기술을 적용해야 한다. 따라서 본 연구에서는 원자력발전소 습분분리재열기세관의 현장적용에 필요한 검사기술을 개발하기 위해서 원격장탐촉자, 인공결함 시험편 및 탐촉자 구동장치를 설계하였으며, 이를 활용하여 발전소 현장 검사에 적용하였다.

열교환기 형상에 따른 분리형 히트파이프 성능 비교 (Separate type heat pipe performance comparison by the heat exchanger shapes)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.723-729
    • /
    • 2016
  • 본 연구에서는 핀-관형 히트파이프와 평행류형 히트파이프 제작하여 시험하였으며 분리형 히트파이프의 작동유체의 충진량은 40~60(% vol.), 풍량은 300~1,400 사이에서 변화시켜가며 온도교환 효율, 열회수량, 공기측 압력강하를 비교하였다. 온도교환 효율은 두 종류의 히트파이프 모든 경우에서 저 풍량에서는 작동유체 충진량이 40(%vol.)일 때가 가장 높았으며 풍량이 증가함에 따라 최대 효율을 가지는 작동유체 충진량이 다름을 알 수 있었고, 환기량이 작을수록 온도교환 효율이 높게 나타났다. 평행류형 히트파이프 60(%vol.)의 실험결과에서 보는 것과 같이 작동 유체를 너무 많이 충진하게 되면 오히려 낮은 온도교환 효율을 보이는데 이는 관벽의 액막이 두터워지면서 열전달 효과를 악화시킨 결과로 최적 충진량이 40~50(%vol.) 사이에 있음을 알 수 있다. 풍량 변화에 따른 공기측 압력강하 비교에서는 증발부 히트파이프가 응축부 히트파이프 보다 크게 계측 되었는데 증발부 표면에 생긴 결로수의 영향으로 생각된다. 평행류형 히트파이프는 핀-관형 히트파이프와 비교하여 냉매 충진량은 48%, 체적은 41%에서 동등이상의 성능을 보였으며, 공기측 압력강하도 37% 정도로 좋은 성능을 나타내었다.

FAPO 제올라이트 흡착제 코팅을 통한 핀-관 열교환기 운전조건별 열전달 성능특성 (Heat Transfer Characteristics of Fin-Tube Heat Exchanger Coated with FAPO Zeolite Adsorbent at Different Operating Conditions)

  • 정철기;김용찬;배경진;차동안;권오경
    • 동력기계공학회지
    • /
    • 제21권3호
    • /
    • pp.93-101
    • /
    • 2017
  • In conventional adsorption chamber, adsorbent is embedded in between heat exchanger fins by wire mesh. This method impedes heat and mass transfer efficiency. So in this study, to improve the heat transfer performance of heat exchanger, a fin-tube exchanger was coated with FAPO (Ferroaluminophosphate) zeolite adsorbent. The fin-tube heat exchanger has a fin pitch of 1.8 mm with a variation of adsorbent coating thickness of about 0.1 mm, 0.15 mm and 0.2 mm. By varying cooling water temperature and chilled water temperature respecively, heat transfer rate and overall heat transfer coefficient were investigated. As a result, the heat transfer rate and overall heat transfer coefficient increase with decreasing cooling water temperature and increasing chilled water temperature. Under the basic conditions, the heat transfer rate of heat exchanger with 0.2 mm coating thickness is 11% and 43% higher than that of 0.1 mm and 0.15 mm, respectively. The overall heat transfer coefficient is $189.1W/m^2{\cdot}^{\circ}C$, it is two times lager than that of 0.1 mm.

냉기 강제순환형 공랭식 쇼케이스 성능 해석 (Performance analysis of a cold-air forced circulation type showcase)

  • 김정식;김내현
    • 한국산학기술학회논문지
    • /
    • 제14권3호
    • /
    • pp.1003-1010
    • /
    • 2013
  • 본 연구에서는 식료품의 진열과 보관에 사용되며 전시효과가 우수한 냉기 강제순환식 쇼케이스의 성능을 예측하는 프로그램을 개발하였다. 압축기의 성능해석에는 제조사에서 제공한 성능선도를 사용하였고 모세관 내 압력손실은 균질유동 모델을 사용하여 계산하였다. 증발기와 응축기는 미소체적으로 구분하여 에너지 균형을 고려하였고 관내측과 공기측 열전달계수는 적절한 상관식으로부터 구하였다. 압축기로 3/4 마력급 왕복동식 2개를 사용하고, 팽창장치로는 내경 1.6 mm의 모세관을, 응축기와 증발기로는 상호 공유형태의 핀-튜브 열교환기를 적용한 쇼케이스 시제품에 대해 성능시험을 수행하고 시험결과와 비교했을 때, 본 프로그램은 시제품의 증발 온도와 응축 온도를 적절히 예측함을 확인하였다.