• Title/Summary/Keyword: 열교환기 설계

Search Result 375, Processing Time 0.025 seconds

A Study on Condensation Heat Transfer in Air Pre-heating Heat Exchanger using Hydrophilic Surface (친수성 표면 처리를 통한 공기 예열 열교환기의 응축 열전달 성능 연구)

  • Park, Jae Won;Hwang, Sueng Sik;Seok, Sung Chul;Shin, Dong Hoon;Chung, Tae Yong;Son, Sueng Gil
    • Journal of Energy Engineering
    • /
    • v.23 no.3
    • /
    • pp.191-197
    • /
    • 2014
  • To increase the heat transfer rate of the air pre-heating heat exchanger used for the condensing boiler, We investigated condensation heat transfer coefficients through plasma surface treatment. The hydrophilic surface showed about 10% increase in heat transfer rate than original plate. It shows that Shah correlation can be used to predict the condensation heat transfer coefficient on the original surface within 10% error range after the compatison between Shah correlation and the condensation heat transfer coefficients measured on the hydrophilic surface and original surface. Therefore, we have shown that Shah correlation is available when designing the air pre-heating heat exchanger using the original surface in this study.

An Experimental Study on Frosting of Humid Air-flow on a Surface with Local Cooling for Heat Exchanger Design (열교환기 설계를 위한 국소 냉각 표면위에서의 습공기 유동의 착상실험)

  • Kwon, Jeong-Tae;Lim, Hyo-Jae;Park, Kyoung-Woo;Kim, Chang-Eob;Kim, Kyung-Min;Kwon, Young-Chul
    • Journal of Energy Engineering
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2008
  • The present study has been conducted to understand the heat and mass transfer characteristics of humid airflow in frosting conditions. A flat plate of aluminum was used for the simulation of flat surface part of the fin of the heat exchanger. The aluminum surface temperatures were measured and analyzed to clarify the heat and mass transfer characteristics under frosting conditions. Also, the pressure drops were measured to clarify the air-blocking effect of frost in the mini channel of the air-side hoot exchangers. A data reduction method was developed far the analysis of local characteristics of humid air under frosting conditions.

Investigation of Flow and Heat Transfer Characteristics of Plate Heat Exchanger Taking into Account Entrance Effects and Variation in Corrugation Height (입구영향 및 주름높이의 변화를 고려한 판형열교환기의 유동 및 열전달 특성)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.965-973
    • /
    • 2010
  • Numerical analysis has been carried out to investigate the heat transfer characteristics of a plate heat exchanger. The multi-cell models with inlet part and outlet part are used for performing numerical simulation. The plate heat exchanger is characterized by chevron angle of $15^{\circ}$, corrugation pitch of 24mm and corrugation height 6~12mm. The length of the inlet-part considered in the analysis ranges from 24.8 to 124mm and Reynolds numbers range from 1,000 to 10,000. The correlations such as friction factor and Colburn factor are compared with previous experimental data. The results can be utilized for designing the plate heat exchanger.

Convective Heat Transfer Correlations for the Compact Heat Exchanger with Circular Tubes and Flat Tubes-Plate Fins (원형관 및 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 상관관계식)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.291-299
    • /
    • 2010
  • Aspect-ratio-based numerical analysis is carried out to investigate the air-side convective heat transfer characteristics in compact heat exchangers with circular tubes and flat tubes-plate fins. The RNG $k-{\varepsilon}$ model is adopted for turbulence analysis. The numerical analysis is carried out for aspect ratios ranging from 3.06 to 5.44 and for Reynolds numbers ranging from 1,000 to 10,000. The calculated results indicate a correlation between the friction factor and Colburn j factor in the compact heat exchanger system for the range of aspect ratios under consideration. The results obtained for circular tubes and flat tubes-plate fins in this study can be utilized to realize the optimal design of an air conditioning system.

Structural Design for Key Dimensions of Printed Circuit Heat Exchanger (인쇄기판형열교환기 핵심치수 구조설계)

  • Kim, Yong Wan;Kang, Ji Ho;Sah, In Jin;Kim, Eung Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.14 no.1
    • /
    • pp.24-31
    • /
    • 2018
  • The mechanical design procedure is studied for the PCHE(printed circuit heat exchanger) with electrochemical etched flow channels. The effective heat transfer plates of PCHE are assembled by diffusion bonding to make a module. PCHE is widely used for industrial applications due to its compactness, cost efficiency, and serviceability at high pressure and/or temperature conditions. The limitations and technical barriers of PCHE are investigated for application to nuclear components. Rules for design and fabrication of PCHE are specified in ASME Section VIII but not in ASME Section III of nuclear components. Therefore, the calculation procedure of key dimensions of PCHE is defined based on ASME section VIII. The effective heat transfer region of PCHE is defined by several key dimensions such as the flow channel radius, edge width, wall thickness, and ridge width. The mechanical design procedure of key dimensions was incorporated into a program for easy use in the PCHE design. The effect of assumptions used in the key dimension calculation on stress values is numerically investigated. A comparative analysis is done by comparing finite element analysis results for the semi-circular flow channels with the formula based sizing calculation assuming rectangular cross sections.

Preliminary Analysis on Design Parameters and Application Effects of Surface Water Heat Exchanger (SWHE) (지표수 열교환기 설계 변수와 적용 효과에 대한 선행 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.3
    • /
    • pp.24-32
    • /
    • 2016
  • Commercial buildings and institutions are generally cooling-dominated and therefore reject more heat to a borehole ground heat exchanger (BHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of BHE. This paper presents the analysis results of the impact of design parameters on the length of SWHE pipe and its application effect on geothermal heat pump (GHP) system using BHE. In order to analysis, we applied ${\varepsilon}-NTU$ method on designing the length of SWHE pipe. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of BHE was more stable than that of standalone BHE system.

전북대학교 플라즈마 풍동용 0.4 MW 분절형 아크 플라즈마 발생 장치 구축

  • Lee, Mi-Yeon;Seo, Jun-Ho;Kim, Jeong-Su;Choe, Chae-Hong;Kim, Min-Ho;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.539-539
    • /
    • 2012
  • 전북대학교 고온플라즈마 응용연구센터는 교육과학기술부 기초연구사업 중 고가연구장비 구축사업의 일환으로, 고 엔탈피, 초음속 유동 환경을 모사하여, 항공우주, 군사기기, 핵융합 분야 등의 고온 재료 개발을 위한 기초 연구 장치로써, 0.4MW급 플라즈마 풍동 장치를 구축하고 있다. 0.4MW 플라즈마 풍동 장치의 플라즈마 발생부는 DC 전원 공급장치와 디스크 형태의 양극과 음극 사이에 동일 형태의 간극을 삽입한 0.4MW급 분절형 아크 플라즈마 토치로 구성되었으며, 토치에서 발생된 아크 플라즈마는 노즐을 통과하며 마하 2~4의 초음속을 나타내도록 설계 제작되었다. 시험 챔버는 노즐에서 나온 초음속 플라즈마의 특성 및 재료 시험을 위한 3차원 이송식 기판이 장착되어 있으며, 고 엔탈피 유동을 관측하기 위한 광학창을 구비하였다. 시험 챔버 하류에는 유동 안정을 위한 디퓨저(diffuser)가 설치되어 있으며, 디퓨저(diffuser)로부터 배출되는 고온가스는 열교환기를 통해 냉각된 후 진공펌프를 통해 대기로 배출되게 된다. 장치의 압력조절을 위하여 $1,000m^3/min$의 용량의 진공펌프 시스템이 설치될 예정이며 가스공급장치, 냉각수 공급장치, 디퓨져, 열교환기는 1MW급 용량으로 설계 제작되었다. 본 장치는 400kW의 전원 공급, 15 g/s의 공기유량 주입 시 약 13 MJ/kg의 고엔탈피를 가진, mach 2~4의 초음속 유동을 나타내는 것을 특징으로 한다.

  • PDF

Heat Exchanger Design For The Individually Allocated Fuel Cell For 1kw Power generation (분산형 소형 연료전지용 1KW급 열교환기 설계)

  • Lee, Taeck Hong;Park, Tae Seong;Kim, Tae Wan;Noh, Jae Hyun;Kang, Young Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.39-46
    • /
    • 2014
  • Our lab designs a heat exchangers for hydrogen gas. Coolant is water, thus it is very difficult to determine heat transfer parameters in this gas-liquid system. Repeated experiments gives overdesign value 6.06%, overall heat transfer coefficient 36.32 ($kcal/m^2-hr-^{\circ}C$) for Hydrogen. Theoretically determined overall heat transfer coefficient is 38.44 ($kcal/m^2-hr-^{\circ}C$). Our lab simulated this system and overdesign 30.4% shows good match with this experiment by HTRI. These parameters are in same range with literature.

A Temperature Control of Thermal Power Plant Superheater System using Iterative Method (반복적 방법을 이용한 화력발전소 과열기 시스템의 온도제어)

  • Sang-Hyuk Lee;Ju-Sik Kim
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.47-55
    • /
    • 1999
  • In this paper, we construct the controller for the heat exchanger system using iterative method. For awlying the linear quadratic control theory to the heat exchanger system which is represented by the bilinear system, we fomrulate the bilinear system to execute iteration We also propose Extended Kalman Filter to estimate bilinear system state for the purpose of state feedback controller design. We also awly the iterative controller to the thennal power plant superheater system temperature control, and computer simulation show that the estimated value follows the superheater steam temperature under the variation of the external inputs, and that the output steam temperature is properly maintained.tained.

  • PDF

Regenerative Cooling Channel Design of a Supersonic Combustor Considering High-Temperature Property of Fuel (연료 고온물성을 고려한 초음속 연소기 재생냉각 유로 설계)

  • Yang, Inyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.6
    • /
    • pp.37-46
    • /
    • 2018
  • A design study on the cooling channel configuration in a regeneratively cooled supersonic combustor was performed. The flow parameters on the hot- and cold-side channels were calculated using a quasi-one-dimensional model. The heat transfer between these two sides was estimated as a part of the flow calculation. For the reference configuration, the total amount of heat exchanged was 10.7 kW, the heat flux was $566kW/m^2$, and the fuel temperature increase between the inlet and outlet was 153 K. Seven designs of the heat exchanger channel were compared for their heat transfer performance.