• Title/Summary/Keyword: 열교환기 모사

Search Result 63, Processing Time 0.025 seconds

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.

A Development of the Correlation for Predicting the Frost Height in Applying Photoelectric Sensors (광센서를 이용한 서리높이 예측 상관식 개발)

  • Jeon, Chang-Duk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.7138-7145
    • /
    • 2015
  • In this study, experiments were conducted to investigate the correspondence between the output voltage of the photoelectric sensor and the frost height under heating and defrosting capacity test condition (dry bulb temperature $2^{\circ}C$, wet bulb temperature $1^{\circ}C$) described at KS C 9306, where a real heat exchanger was used as a test rig instead of a large-scale model. A digital microscope and a photoelectric sensor unit consisting of an emitter and a transistor (receiver) were installed in the front of it. A linear correlation is proposed to predict the frost height based on 150 experimental data, approximately 54% of the measured data are consistent with the predicted frost heights within a relative deviation of ${\pm}10%$, it yields good agreement with 90% of the measured data when the frost height larger than 0.3mm with in a relative deviation of ${\pm}10%$. Compared with Xiao's correlation, the slope namely, the change of frost height in accordance with the change of output voltage is consistent within the error of 2.3%. But vertical intercept shows big difference with Xiao's correlation, because it was developed with a large scale model instead of a real heat exchanger.

Heat Flow Characteristics on Type of Heat Transfer Plate for White Smoke Reduction under Uniform Flow Condition (균일유동에서 백연저감용 전열판 형태에 대한 열유동 특성)

  • Son, Jun;Cha, Jae Min;Wang, Zhen Huan;Kwon, Young Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.591-596
    • /
    • 2016
  • Numerical analyses were performed on the heat flow characteristics of a heat transfer plate with six different shapes (basic, rectangle, triangle, wave type) to reduce the level of white smoke at a stack. In this study, to examine the heat transfer performance (heat transfer capacity, pressure drop, turbulence kinetic energy, heat transfer coefficient) on the heat transfer plates, simulations were conducted using the commercial computational fluid dynamics software, ANSYS CFX Ver.14 under uniform flow conditions. The thermal flow phenomenon in a channel with six heat transfer plates could be predicted adequately under uniform flow conditions. The heat transfer capacity, pressure drop, turbulence kinetic energy, and heat transfer coefficient were affected by the flow rate, aspect ratio and plate shape. These results provide guidelines to design an effective heat exchanger with the wave type to reduce white smoke.

A Study on the Condensation Modeling Method for Fast Pyrolysis Gas of Biomass (바이오 매스 급속 열분해 가스의 응축 모델링 기법에 관한 연구)

  • Park, Hun Chae;Choi, Hang Seok;Choi, Yeon Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.107.1-107.1
    • /
    • 2011
  • 최근 석유, 가스, 석탄을 비롯한 화석연료의 다량 사용으로 기후변화, 대기오염 등의 환경문제 및 자원 고갈의 우려 때문에 바이오매스는 중요한 화석연료 대체 에너지 자원으로써 큰 관심을 받고 있다. 바이오매스 자원을 에너지로 전환하는 방법 중 하나인 급속 열분해 공정은 산소가 없는 상태에서 바이오매스를 열적으로 분해하여 액상 상태의 생성물을 회수하는 공정으로, 증기상의 열분해 가스를 응축하여 회수하게 된다. 바이오매스의 급속 열분해에 관한 연구는 주로 바이오매스의 종류와 열분해 조건에 따라 회수되는 바이오 원유의 수율 및 물리 화학적 특성에 관한 연구가 수행되고 있으나, 열분해 가스의 응축에 관한 연구는 응축에 수반되는 복잡한 물리적 현상 때문에 미진하다. 따라서 본 연구에서는 바이오매스의 급속 열분해를 통해 생성되는 증기상의 열분해 가스의 응축 현상을 모사 할 수 있는 모델링 기법에 대해 연구하였다. 급속 열분해 공정을 통해 생성되는 바이오 원유는 수백개의 화합물로 구성되어 있으며, 동일한 바이오매스를 사용한 경우라도 공정조건에 따라 바이오 원유에 포함된 화합물은 달라진다. 따라서 본 연구에서는 바이오 원유의 주요 화합물인 water, propanal, butanal, pentanal, phenol, guaiacol, coniferyl alcohol, formic acid, acetic acid, propanoic acid, butanoid acid를 대상으로 열분해 가스의 응축을 모사하였다. 본 연구에서는 응축 모델링 기법의 검증을 위해 실험결과와 비교하여 정확성을 검증하였으며, 본 연구의 결과를 활용하여 응축 조건 변화에 따른 급속 열분해 가스의 응축률을 예측하고, 이를 이용한 응축 열교환기 설계에 유용하게 사용될 수 있을 것으로 판단된다.

  • PDF

Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop (파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가)

  • Gil, Hu-Jeong;Lee, Chul-Ho;Lee, Kang-Ja;Choi, Hang-Seok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

Steady-state Modelling of Centrigugal Chiller through On-Site Test (현장성능시험에 의한 터보냉동기의 정상상태모델 개발)

  • Chang, Young-Soo;Shin, Young-Gy;Baik, Young-Jin;Kim, Young-Il
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.83-88
    • /
    • 2001
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field data of chiller installed in the clean-room building of KIST have been collected, Simple models were developed for predicting the heat exchangers and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flow rates of secondary fluids. The models are consistent with real performance data from June to September within ${\pm}5%$ error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rate of chilled and cooling water.

  • PDF

Simulation for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수 열원 및 폐열 이용 고성능 열펌프 시스템 모사)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.1
    • /
    • pp.59-66
    • /
    • 2003
  • The purpose of this study is to analyze the characteristics (COP) of the heat pump system for various operating conditions with the use of seawater heat source and exhaust energy. To accomplish the goal, first of all, the computer simulation for heat pump system is carried out. The heat pump system model is made of a waste heat recovery system and a vapor compression refrigeration system, and the working fluid is R-22. The model calculated the change of COP with the variation of temperature and flow rate. The COP and the plate heat exchanger (PHE) area of the heat pump system are considered moderately high in the condensation temperature of $25^{\circ}^C$ and the evaporation temperature of $2^{\circ}^C$ in indoor culture system. The simulation results will be used effectively for the design and the performance prediction of heat pump system using unused energy in a land base aquaculture system.

Transient Computer Simulation of Evaporation and Condenser in an Automotive Air-Conditioning System (비정상과정에서 자동차 에어컨의 증발기 및 응축기의 컴퓨터 시뮬레이션)

  • Oh, Sang-Han;Shin, Dong-Woo;Won, Sung-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.19-24
    • /
    • 2000
  • The objective of this study is to develope a computer simulation model and estimate theoretically the transient performance characteristics of heat exchangers in an automotive air-conditioning system. To do that, the mathematical modelling of heat exchangers, such as evaporator and condenser, is presented first of all. For detail calculation, evaporator and condenser are divided into many sub-sections. Each sub-section is an elemental volume for transient modelling. The elemental volume is assumed to consist of three components, refrigerant, tube with fin, and air, and various properties including temperatures of three components are determined step along sub-sections. The properties of refrigerant R134a and air are calculated directly in the program. The heat transfer coefficients and pressure drop in single or two phase are also calculated by suitable empirical correlations. The overall tendencies of the simulation results were agreed well with those of actual situation.

  • PDF

Effort of C and N on corrosion resistance of 6Mo grade super stainless steel (6Mo급 슈퍼 스테인리스강의 부식 특성에 미치는 탄소 및 질소의 영향)

  • 김수한;박용수;류우석;국일현;김영식
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.05a
    • /
    • pp.102-102
    • /
    • 1999
  • 6Mo급 슈퍼 스테인리스강의 내식성은 여러 환경에서 여러 가지의 부식 시험 방법을 통해서 확띤되어 왔다. 이 합금이 보이는 탁월한 내식성 때문에 해수 설비 계통,정유 설비,원자력 발전소의 열교환기 등의 중요 재료로서 그 사용 용도가 급격히 증가하고 있다. 그런데 방사선의 영향을 받게 되는 설비에 금속 재료가 사용되는 경우,특히 경수로의 노내 구조물, 액체 금속로의 열교환기, 핵융합로의 제1벽 재료 등 에서는 합금 원소가 방사성 환경에 의하여 제거되는 현상이 나타난다. 따라서 본 연구에서는 이러한 상황을 미리 재료 제조 차원에서 모사하여 탄소량과 질소량의 함량 을 달리 한 6Mo급 슈퍼 스테인리스강을 제조하여 미세 조직, 기계적 성질 및 부식 특성의 변화에 대하여 연구하였다. 진공 고주파 유도 용해로를 이용하여 탄소량과 질소량이 각기 변화된 슈퍼 스테인리스강을 용해 한 뒤 아르곤 가스 분위기에서 $1180^{\circ}C$로 soaking하고 열간 압연을 행하였다. 열간 압연으로 표변에 생성된 산화 스케일을 불산과 질산의 혼합 용액으로 제거한 뒤 냉간 압연을 행하였다. 이 냉연 판재에 대하여 $1150^{\circ}C$로 소둔하여 각 실험에 사용하였다. 광학 현미경을 이용하여 미세 조직의 변화를 관찰하였으며, 상온과 고온($520^{\circ}C$)에서 인장 시험을 행하였으며, 경도 측정을 행하였다. 또한 양극 분극 시험과 비등 질산 침지 시험 및 비등 40% NaOH 용액에서의 일정 연신율 시험을 행하 였다. 탄소 함량이 증가할수록 항복 강도 및 인장 강도는 증가하고 있으며 연신율은 감 소하는 일반적인 경향을 보였으며 비등 질산 시험에서는 탄소량에 관계없이 매우 우수한 내식성을 쁘였다. 또한 비등 상태의 40% NaOH 용액에서의 응력 부식 균열 시험 결과, 탄소량이 증가할수록 부식 저항성이 증가하고 있는 것으로 평가되었다. 한 편 질소량이 증까할수록 결정립이 미세화되었으며 경도값이 상승하였다. 이들 합금 에 대한 양극 분극 시험 결과, 질소량의 변화가 탄소량의 변화보다 내식성에 큰 영향 을 미치고 있음을 알 수 있었다.

  • PDF

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.