• 제목/요약/키워드: 열관

Search Result 8, Processing Time 0.026 seconds

Study on the Satellite Thermal Control Hardware Composed of Two Parallel Channels Working for Heat Pipe and Phase Change Material (열관과 상변화물질을 일체형으로 병렬 배열한 위성용 열제어 부품 연구)

  • Kim, Taig-Young;Hyun, Bum-Seok;Lee, Jang-Joon;Rhee, Ju-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.11
    • /
    • pp.1087-1093
    • /
    • 2010
  • The satellite thermal control H/W composed of two parallel channels working for heat pipe (HP) and phase change material (PCM) is suggested for the high heat dissipating component which works intermittently with short duty. In a limited point of view, the HP-PCM device is a kind of off-the-shelf component that requires no dedicated configuration and thermal designs to PCM. Therefore, it can be used with less impact on the program cost and schedule different from most of the PCM applications. In present study the typical honeycomb structure radiator applying the HP-PCM device is designed and the detail thermal math model is developed for numerical analyses. The result comparison between without and with PCM shows that the HP-PCM device redistributes the peak heat around the whole mission period through the alternate melting and freezing of PCM, and, as a result, the maximum and minimum temperatures are effectively alleviated. The drawback of PCM application due to low thermal conductivity can be successfully resolved by means of parallel arrangement of HP channel.

Satellite Thermal Control Device Enhanced by Latent Heat of the Phase Change Material (응고/융해 잠열을 이용한 위성용 열제어장치의 실험적 연구)

  • Kim, Tae Su;Shin, Yoon Sub;Kim, Taig Young;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.10
    • /
    • pp.887-894
    • /
    • 2016
  • The thermal control device using solid-liquid phase change material (PCM) is designed, manufactured, and experimented in thermal environment chamber. The n-Hexadecane is selected as a PCM and its melting point is placed within the component working temperature range. The PCM container is made of Al6061 and has the thermal spreading fins inside. To simulate the working condition for on-orbit satellite the heat pipes are used to connect the heater and radiator and the PCM thermal control device (PCMTD) is installed at the middle portion of heat pipes. The thermal buffer mass (TBM), which is same configuration and volume with PCMTD, is also manufactured to compare the thermal control performance. As a result, the PCMTD is not only more efficient than TBM in their temperature control features but both mass and power of compensation heater are reduced.

Numerical Study on the Thermal Control Device for Satellite Components Using the Phase Change Material Combined with Heat Pipe in Parallel (상변화물질과 열관을 병렬 조합한 위성부품 열제어장치의 수치해석적 연구)

  • Shin, Yoon Sub;Kim, Tae Su;Kim, Taig Young;Seo, Young Bae;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.4
    • /
    • pp.373-379
    • /
    • 2016
  • The thermal control device for the periodic working component combined solid-liquid phase change material (PCM) with heat pipes is designed and numerically studied. Due to high latent heat and retaining constant temperature during melting process the component peak temperature, not withstanding small radiator size, is reduced. The warm-up heater power consumption to keep the minimum allowed temperature is also cut down since the accumulated thermal energy is released through the solidification. The thermal buffer mass (TBM) made of Al can give the similar effect but the mass and power consumption of warm-up heater should increase compared to PCM. The amount of PCM can be optimized depending on the component heat dissipation and on/off duty time.

Stress Analysis of Steam Generator Row-1 Tubes (증기발생기 제1열 전열관의 응력 해석)

  • Kim, Woo-Gon;Ryu, Woo-Seog;Lee, Ho-Jin;Kim, Sung-Chung
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.25-30
    • /
    • 2000
  • Residual stresses induced in U-bending and tube-to-tubesheet joining processes of PWR's steam generator row-1 tube were measured by X-ray method and Hole-Drilling Method(HDM). The stresses resulting from the Internal pressure and the temperature gradient in the steam generator were also estimated theoretically. In U-bent lesions, the residual stresses at extrados were induced with compressive stress(-), and its maximum value reached -319 MPa in axial direction at ${\psi}=0^{\circ}$ in position. Maximum tensile residual stress of 170MPa was found to be at the flank side at Position of${\psi}=90^{\circ}$, i.e., at apex region. In tube-to-tubesheet fouling methods, the residual stresses induced by the explosive joint method were found to be lower than that by the mechanical roll method. The gradient of residual stress along the expanded tube was highest at the. transition region, and the residual stress in circumferential direction was found to be higher than the residual stress in axial direction. Hoop stress due to an internal pressure between primary and secondary side was analyzed to be 76 MPa and thermal stress was 45 MPa.

  • PDF

A development of a general purposed control system of robot end-effector for inspection and maintenance of steam generator heat pipe (증기발생기전열관의 검사정비로봇용 엔드이펙터의 범용 제어시스템 개발)

  • Park, Ki-Tae;Kim, Seon-Jin;Lho, Tae-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • The general purposed control system for driving a motion of many different typed robot end-effector, which consists of a controller based on ARM Cotex M3-11017 MCU and an application software for generating a motion of end-effector, was developed. Experimental results show that a positioning error is nearly negligible and a repeatability error is 0.04%. Accordingly the developed control system can be applied practically to actuate a robot end-effector for inspection and maintenance of steam generator heat pipe in nuclear power plant.

A Study of Storage Type Cooling and Heating System by Heat Pipe (히트파이프를 이용한 축열식 냉.난방 시스템에 관한 연구)

  • Kim, Seong-Sil;Harm, Seong-Chol;Lee, Yang-Ho;Choi, Byoung-Youn
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.3-8
    • /
    • 2006
  • The heat pump system is attractive alternatives to conventional heating and cooling systems owing to their higher energy utilization efficiency. The thermal loads of commercial and institutional buildings are generally cooling-dominated. In this study have been developed ice storage type heat pump system for cooling and heating by heat pipe. This system was practiced performance test on evaluation criteria for heat storage systems. Accomplished the actual proof examination and looked into the performance of the system. In this study, measurement and analysis of ice storage type heat pump system for cooling and heating by heat pipe. The heat pump unit COP appears 3.05 for cooling and 4.20 for heating. As a result, the method to energy saving and to using a substitute energy actively that is heat pump cooling & heating system is expected by heat pipe. Thermal storage capacity appears $19.5RTH/m^3$ for cooling.

  • PDF

Bonding Mechanism of Direct Copper to Glass Seal in an Evacuated Tube Solar Collector (태양열 집열기에 사용되는 구리-유리관 접합기구)

  • 김철영;남명식;곽희열
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.11
    • /
    • pp.1000-1007
    • /
    • 2001
  • In an evacuated tube solar collector, the stable sealing of the heat pipe to the glass tube is important for the collector to use for a long period of time. The sealing of copper tube to the glass is quite difficult because of the large differences in the physical and chemical properties of the two materials. In this study, therefore, a proper copper oxide layer was induced to improve the chemical bonding of the two materials, and the oxidation state of copper and the interface between copper and glass were examined by XRD, SEM and EDS. Its bonding strength was also measured. Cu$_2$O was formed when the bare copper was heat-treated under 600$^{\circ}C$, while CuO oxide layer was formed above that temperature. The bonding state of CuO to the copper was very poor. The borate treatment of the copper, however, extend the stable forming of Cu$_2$O layer to 800$^{\circ}C$. Borosilicate glass tube was sealed to a copper tube by Housekeeper method only when the sealing part was covered with Cu$_2$O layer. The bonding strength at the interface was measured 354.4N, its thermal shock resistance was acceptable.

  • PDF